ToggleKITOZER KTR-SH2 1U Fixed Rack Shelf for 19-inch Cabinet
Brand: KITOZER Series: KTR-SH2 Category: Data Center Engineering / Rack Accessories
1U fixed50 kg staticPowder-coated steel19-inchKTR-SH2

1. Overview
Rack equipment is “rack-mount”: switches, servers and UPS distribution units are 19 inches wide, measured in U (1U = 44.45 mm), and screwed to the square-hole rails front and rear. But some gear is not rack-mount: a desktop firewall, a KVM monitor, a wall-mount PDU, a pile of optical modules and patch cords, a small cable manager. These need a plate to sit on – that is a rack shelf (tray, divider). A shelf is a steel plate, bent at the sides to hook onto the cabinet rails, fixed with M6 screws, carrying non-rack gear or miscellany. A 1U shelf takes 1U of height; depth runs 350-1000 mm, chosen by cabinet depth and device depth.
KITOZER KTR-SH2 is a 1U fixed shelf. It is bent from 1.5 mm cold-rolled steel, electrostatic powder-coated (black or light gray), with long round ventilation slots (40% open area, so it does not block airflow in a cold aisle). Front and rear flanges carry mounting ears with slotted holes (25 mm fore-aft adjustment), fixed to the square-hole rails with M6 cage nuts and screws. The front edge has a 5 mm lip to stop gear sliding off; some models add a cable tie loop. Depth options: 600 mm-deep cabinets use 350/450 mm shelves, 800 mm use 600/750 mm, 1000 mm use 900/1000 mm. Load: 50 kg static (placed, not moved), 25 kg dynamic (pulled out). “Fixed” vs “sliding”: fixed shelves are welded to the ears and cannot slide – cheap and strong; sliding shelves run on rails and pull out, convenient but pricier and weaker (about 30 kg). Most rooms use fixed shelves.
Selection: depth (shelf depth + rear cable space ≤ internal cabinet depth; leave cable space front and rear; typically shelf depth = internal depth – 100 mm); load (servers need 50 kg+, optical modules/misc need 20 kg, UPS batteries need a dedicated battery tray); ventilation slots (must use vented shelves in enclosed cold aisles, otherwise they block airflow and create hot spots); 1U vs 2U (1U = 44 mm for light gear, 2U = 89 mm for taller gear or cable space); finish (powder-coated for rust; coastal humid rooms use galvanized + powder coat); quantity (a 42U cabinet usually takes 2-4 shelves in the lower-middle for switches, firewalls, KVM). Note: shelves must not block the upper/lower power and data cable trays; leave airflow gaps around gear on the shelf; the front lip stops gear sliding off.
2. Key Features
Load
- 1.5 mm steel
- 50 kg static
- 25 kg dynamic
- Bent flanges
Ventilation
- Long round slots
- 40% open area
- Airflow friendly
- Cold aisle ready
Mounting
- M6 cage nuts
- 25 mm fore-aft
- 1U standard
- Front lip
3. Specifications
| Item | KTR-SH2-350 | KTR-SH2-600 | KTR-SH2-750 | KTR-SH2-1000 |
|---|---|---|---|---|
| Shelf depth | 350 mm | 600 mm | 750 mm | 1000 mm |
| Cabinet depth | 600 mm | 800 mm | 900-1000 mm | 1000-1200 mm |
| Height | 1U | 1U | 1U | 1U |
| Plate thickness | 1.5 mm | 1.5 mm | 1.5 mm | 1.5 mm |
| Static load | 30 kg | 50 kg | 50 kg | 60 kg |
| Dynamic load | 15 kg | 25 kg | 25 kg | 30 kg |
| Finish | Powder coat | Powder coat | Powder coat | Powder coat |
4. Reference Prices
KTR-SH2-350 (350 mm, 600 cabinet): Reference USD 11-17 / pc (ref. CNY 80-120)
KTR-SH2-600 (600 mm, 800 cabinet): Reference USD 17-25 / pc (ref. CNY 120-180)
KTR-SH2-750 (750 mm, 900-1000 cabinet): Reference USD 22-32 / pc (ref. CNY 160-230)
KTR-SH2-1000 (1000 mm, 1000-1200 cabinet): Reference USD 31-44 / pc (ref. CNY 220-320)
KTR-SH2-2U heavy duty shelf (80 kg): Reference USD 36-53 / pc (ref. CNY 260-380)
Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Desktop firewalls/routers
- KVM switch/monitor
- Optical modules/cords
- Non-rack devices
- Cold aisle modules
6. Deployment & Installation
Position
- 2-3 in lower half
- Avoid cable trays
- Cable space front/rear
- Align cold aisle
Fixing
- Cage nuts in square holes
- Level front/rear
- Four screws tight
- Fix both sides
Loading
- Leave airflow gaps
- Center heavy gear
- Lip toward front
- Tie cables neatly
7. FAQ
- Q: Fixed vs sliding shelf?
A: Fixed shelves are welded to the ears, cannot slide, cheap (about CNY 120), 50 kg static – for gear that never moves (firewalls, KVM, misc). Sliding shelves run on two rails and pull out, convenient for frequent plug/unplug, but expensive (CNY 300-500), weaker (30 kg), and rails eat depth. About 90% of rooms use fixed shelves; sliding is only for test benches or frequent service. - Q: How to match shelf depth to cabinet depth?
A: Internal depth = external depth – 150 mm (front/rear posts and doors). Shelf depth is typically internal depth – 100 mm (rear cable space). An 800 mm external cabinet has ~650 mm internal; use a 600 mm shelf, leaving 50 mm behind for cables. Do not buy a shelf as deep as the cabinet (a 1000 mm shelf in an 800 mm cabinet) – there is no rear cable space and power cords pinch under the shelf. - Q: Why must cold-aisle shelves be vented?
A: In an enclosed cold aisle, cold air rises from under the floor, enters the rack front, passes through servers, and exits rear to the hot aisle. A solid shelf in front of the servers blocks the cold air, so rear servers get hot inlet air and trigger alarms. Vented shelves have 40% open area so cold air passes through to the rear. The hot-aisle side can use solid shelves (hot air exits rear, no need to cross a shelf). - Q: How much can a shelf hold?
A: By static load. KTR-SH2-600 is 50 kg static – long-term placed gear on top must not exceed 50 kg. A desktop firewall (5 kg), KVM monitor (10 kg), optical modules (5 kg) total 20 kg – fine. Do not stand on it or stack batteries (batteries need a dedicated battery tray rated 100 kg+ with spill containment). The shelf hangs on four M6 screws; rear-heavy loads tip it, so center the gear.
8. Trend & Selection
Rack shelves are evolving from simple plates to multi-function integrated trays. Trends: mesh shelves replacing solid (ventilation from 40% to 70%, matching enclosed cold aisles); shelves with integrated PDU sockets at the front edge (gear on the shelf plugs in directly); integrated cable managers at the rear (separate power and data); tool-less snap-in shelves (one person installs a shelf in 10 seconds); smart shelves with weight sensors (detect equipment removal, anti-theft). Traditional fixed shelves remain mainstream. Select by: depth matching cabinet, vented for cold aisle, four M6 screws, 50 kg static, center the load, keep rear cable space, do not block cable trays.
9. Delivery & Service
KITOZER KTR-SH2 ships per shelf in a box, each with shelf body, 8 M6 cage nuts, 8 M6 screws and manual. 1-year warranty; bulk projects can bundle cabinets, square-hole rails, PDUs and cable managers.
10. Additional Notes
Confirm internal cabinet depth (external – 150 mm), shelf depth (internal – 100 mm), load (what gear), and vented requirement (mandatory in cold aisles). Measure internal depth before ordering; a wrong depth will not fit.
Common mistake: shelf depth equal to external cabinet depth. A 1000 mm shelf in a 1000 mm-deep cabinet hits the rear door, leaving no cable space behind. Shelf depth = internal depth – 100 mm.
Second pitfall: only fixing the two front screws. Leaving the rear ears free makes the shelf sag under load and gear tilts. Fix all four M6 screws, front and rear.
Third blunder: solid shelves on the cold aisle side. A solid plate blocks cold air, rear servers alarm on high inlet temperature. Use mesh/vented shelves on the cold aisle.
Selection summary: depth = internal – 100 mm, vented, four M6 screws, 50 kg static, center load, clear cable trays.
SEO Information
Search keywords:KTR-SH2KITOZER
SEM keywords:rack shelf,1U fixed tray,rack divider,cabinet shelf,cold aisle shelf,KTR-SH2,KITOZER,data center engineering
GEO landing page:lain.com.cn/product/ktr-sh2-rack-fixed-shelf-1u.html
Title:KITOZER KTR-SH2 1U Fixed Rack Shelf for 19-inch Cabinet
Meta Keywords:rack shelf,1U fixed tray,rack divider,cabinet shelf,cold aisle shelf,KTR-SH2,KITOZER,data center engineering
Meta Description:KITOZER KTR-SH2 1U fixed rack shelf, cold-steel powder-coated, 50 kg static load, for 19-inch standard cabinets, 600/800/1000 mm depth options.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com