ToggleKITOZER KTR-THERM Dual-Spectrum Thermal Camera for Data Center
Brand: KITOZER Series: KTR-THERM Category: Environmental Monitoring / Video Surveillance
Visible + thermal384×288 IR+/-2 CONVIF/RTSPKTR-THERM

1. Overview
The most dangerous data center failure is not water, but overheating from a bad electrical contact. A loose terminal in a PDU, an UPS output breaker with rising contact resistance, a server PSU heatsink clogged with dust – all heat up locally. Temperature climbs slowly: normal at 30 C, after months reaches 60 C, then 80 C, insulation ages, finally arcs and short-circuits into a fire. Traditional T/H sensors only measure room air, not a terminal inside a rack. To measure surface temperature you need thermal imaging: every object at temperature radiates infrared; a thermal lens picks it up and converts it to a temperature map – hot spots light up in red. A dual-spectrum camera packs a visible-light lens (daily surveillance) and a thermal lens (temperature mapping) in one housing, outputting two video streams at once.
KITOZER KTR-THERM is a dual-spectrum bullet/dome camera. Visible channel: 4 MP (2560×1440), H.265, 2.8/4 mm lens, IR-cut day/night, for ordinary monitoring. Thermal channel: uncooled VOx microbolometer, 384×288 (economy) or 640×512 (high-precision), NETD ≤50 mK, 9 mm lens (~45 deg FOV for a row of racks) or 19 mm (narrow FOV inside a PDU). Temperature range -20 to +150 C (enough for rooms; industrial version to 550 C), accuracy +/-2 C or +/-2% of reading. Measurement: full-frame temperature (every pixel), hottest-spot marker (auto find the hottest point), rule boxes (draw multiple zones on a PDU breaker array, each with its own threshold). Alarms: on threshold breach, the camera uploads via ONVIF/RTSP/GB28181 to the VMS, pops a red box on screen and beeps.
Selection: resolution (384×288 for overview of a rack row; 640×512 for small terminals inside a PDU – more pixels resolve smaller hot spots); lens (9 mm wide for rack rows, 19 mm telephoto for PDU interiors; longer lens sees farther and narrower); accuracy (+/-2 C industrial, +/-0.5 C lab, +/-2 C is enough for rooms); output (Hikvision/Dahua NVR use ONVIF or GB28181; custom platform uses RTSP/SDK); power (PoE over Ethernet is convenient; DC12 V needs a separate supply); mounting (bullet fixed to one wall; dome PTZ rotates; rooms usually use bullet, mounted above the aisle looking down at a rack row). Note: thermal cannot see through glass (glass blocks IR), keep the lens exposed; do not point at AC outlets (cold air distorts); at long range, a pixel covers a larger ground area and small hot spots average out.
2. Key Features
Thermal
- VOx uncooled detector
- 384×288/640×512
- NETD ≤50 mK
- -20 to +150 C
Visible
- 4 MP
- H.265
- IR-Cut day/night
- 2.8/4 mm lens
Connectivity
- ONVIF/RTSP
- GB28181
- PoE
- Hot-spot marker
3. Specifications
| Item | KTR-THERM-336 | KTR-THERM-636 | KTR-THERM-BALL | KTR-THERM-PRO |
|---|---|---|---|---|
| Thermal res. | 384×288 | 640×512 | 384×288 | 640×512 |
| Visible res. | 4 MP | 4 MP | 4 MP | 8 MP |
| Range | -20 to +150 C | -20 to +150 C | -20 to +150 C | -20 to +550 C |
| Accuracy | +/-2 C | +/-2 C | +/-2 C | +/-0.5 C |
| Thermal lens | 9 mm | 19 mm | 9 mm + PTZ | 19 mm |
| Power | PoE/DC12 V | PoE/DC12 V | PoE/AC24 V | PoE/DC24 V |
| Form factor | Bullet fixed | Bullet fixed | Dome PTZ | Premium bullet |
4. Reference Prices
KTR-THERM-336 bullet (384 thermal, rack row): Reference USD 900-1250 / pc (ref. CNY 6500-9000)
KTR-THERM-636 bullet (640 thermal, PDU): Reference USD 1670-2220 / pc (ref. CNY 12000-16000)
KTR-THERM-BALL dome (PTZ): Reference USD 2500-3470 / pc (ref. CNY 18000-25000)
KTR-THERM-PRO high precision (+/-0.5 C): Reference USD 3470-4860 / pc (ref. CNY 25000-35000)
KTR-THERM-SDK VMS software (32 ch license): Reference USD 420-700 / set (ref. CNY 3000-5000)
Reference only. 2-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- PDU/row cabinet hot spots
- Rack row overhead view
- UPS battery terminals
- Busbar joints
- Archive room fire warning
6. Deployment & Installation
Position
- Over aisle, overhead
- 3 m from PDU
- No glass in between
- Avoid AC outlets
Calibration
- Emissivity 0.95
- Test a known target
- Adjust reading
- Draw alarm zones
Integration
- ONVIF to NVR
- Threshold 55 C
- High-temp popup
- VMS logs events
7. FAQ
- Q: Thermal vs ordinary surveillance camera?
A: A visible camera shoots reflected visible light – it sees people, faces and gear by day, needs IR illuminator at night, but cannot measure temperature. A thermal camera shoots the infrared radiation objects emit by themselves – it works in total darkness and every pixel carries a temperature value. Dual-spectrum packs both lenses: one stream looks like normal CCTV, one reads temperature, both output simultaneously. Rooms need both (people for security, temperature for fire prevention), hence dual-spectrum. - Q: Why open a PDU panel to measure inside?
A: Infrared does not pass through ordinary glass or metal (glass lets visible through but blocks IR; metal reflects completely). With the PDU metal door closed, the thermal lens only sees the door surface, not the breakers inside. To measure internal terminals, either remove the panel (unsafe), install an IR-transparent window (germanium or zinc sulfide glass – visible opaque but IR transparent, expensive), or insert a borescope thermal probe. Typical practice: point thermal at the closed PDU front to monitor internal air and cable entries; for breaker terminals, use a handheld thermal camera during patrols. - Q: Is +/-2 C accuracy enough?
A: Electrical gear normally runs 40-60 C; alarm threshold 55 C, trip threshold 70 C. At +/-2 C, a true 55 C reads 53-57 C. With threshold margin (alarm at 55, danger at 60), +/-2 C is enough. For precision bearings (normal 40, warning 45), +/-2 C is too coarse – choose the +/-0.5 C PRO. Room electrical monitoring at +/-2 C is the industry mainstream. - Q: How many thermal cameras per room?
A: By FOV coverage. A 384-resolution, 9 mm bullet at 3 m height covers ~45 deg wide and 3 m high – roughly a row of 8 racks. A 100 m² room with two rack rows needs 2 bullets (one per row) overhead. PDU and UPS battery rooms each get a close-up unit. A PTZ dome can rotate to see many directions, but only one direction at a time – good for patrol, not for simultaneous monitoring.
8. Trend & Selection
Thermal imaging is moving from fixed overview to AI and edge computing. Trends: AI fire detection (on-camera algorithm auto-spots arcs and smoldering points, no need to watch temperature curves); multi-sensor fusion (visible + thermal + laser rangefinder, auto-locks hot spots and measures distance); 5G/wireless (outdoor cabinets without Ethernet use 5G backhaul); temperature big data (upload all thermal data, build equipment temperature baselines, warn on deviation rather than absolute thresholds); detector chips (384×288 evolving to 640×512 and 1024×768, cost falling, thermal moving from defense to civilian rooms). Select by: 384 for rack rows, 640 for PDUs, +/-2 C, ONVIF to NVR, emissivity 0.95, no glass, 55 C warning.
9. Delivery & Service
KITOZER KTR-THERM ships per camera in a box, each with camera body, mount bracket, PoE splitter, power adapter and quick guide. 2-year warranty; bulk projects can bundle VMS software, NVR storage, wall/ceiling brackets and emissivity calibration targets.
10. Additional Notes
Confirm target (rack row / PDU / UPS battery), distance (9 mm within 3 m, 19 mm beyond 5 m), resolution (384 overview / 640 detail), and platform protocol (NVR/VMS). For batch orders, commission one unit on site to verify temperature calibration before rollout.
Common mistake: measuring a PDU through a glass door. Glass blocks IR completely – the screen shows glass surface temperature, not the cabinet interior. To measure inside, remove the door or fit an IR window.
Second pitfall: no emissivity setting. Default emissivity is 1.0 (blackbody); shiny metal terminals reflect strongly. At a true 80 C with emissivity 0.6, the camera computes 50 C – badly under-reading. Set emissivity to 0.6-0.95 (painted black 0.95, bare copper 0.6).
Third blunder: pointing at AC outlets. Cold air at 15 C makes the lens read air temperature, not rack temperature. Mount away from outlets, aimed at rack fronts.
Selection summary: 384 overview / 640 detail, +/-2 C, no glass, emissivity 0.95, avoid cold air, ONVIF upload, 55 C warning.
SEO Information
Search keywords:KTR-THERMKITOZER
SEM keywords:thermal camera,dual spectrum monitoring,data center thermal camera,thermal imaging,KTR-THERM,KITOZER,environmental monitoring
GEO landing page:lain.com.cn/product/ktr-thermal-dual-spectrum-camera.html
Title:KITOZER KTR-THERM Dual-Spectrum Thermal Camera for Data Center
Meta Keywords:thermal camera,dual spectrum monitoring,data center thermal camera,thermal imaging,KTR-THERM,KITOZER,environmental monitoring
Meta Description:KITOZER KTR-THERM dual-spectrum thermal camera, 4 MP visible + 384×288 thermal, +/-2 C accuracy, for data center equipment temperature early warning and PDU hot-spot monitoring.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com