KITOZER
KITOZER

KITOZER 3 phase power SPD box

KITOZER KTR-PSB3 Three-Phase Power Surge Protection Box

Brand: KITOZER Series: KTR-PSB3 Category: Power Distribution / Surge Protection

3-phase 380VClass I Iimp4P moduleKTR-PSB3

KITOZER KTR-PSB3 Three-Phase Power Surge Protection Box

1. Overview

Lightning or grid switching surges travel along power lines into a data center: a nearby direct strike creates an electromagnetic pulse, or switching of large loads produces a spike of several kV to tens of kV that punches through server power supplies, motherboards and disks. A surge protective device (SPD) is paralleled between line and ground – high impedance in normal service, conducting in nanoseconds during a surge to clamp voltage to a safe value (below about 2.5 kV) and divert surge current to earth. Power SPDs are staged in three levels: class I (B) at the mains intake cabinet diverts direct-strike high current (Iimp 12.5-25 kA, 10/350 us waveform); class II (C) at the floor distribution diverts residual energy (In 20-40 kA, 8/20 us); class III (D) at the rack PDU front gives fine protection (In 10-20 kA). A three-phase power SPD box houses four modules (3P+N) in a steel enclosure with remote alarm, mounted in the room intake cabinet or wall-mounted.

KITOZER KTR-PSB3 is a class I three-phase power SPD box. Steel wall box (300x400x120 mm) with four modular cartridges (L1-L2-L3-N, PE earth bar), class I B rating: Iimp (10/350 us) 12.5 kA per pole (upgradable to 25 kA), In (8/20 us) 20 kA per pole, Imax 40 kA, voltage protection level Up <=2.5 kV, rated voltage Un 385 V (for 380/400 V systems), response time <=25 ns, remote contact (dry contact - module failure or overcurrent outputs to the EM platform), visual window per module (green OK / red failed). Key ratings: 4P (3P+N), terminals 25-50 mm2, wall or DIN-rail mount, -40 to +80 C.

Selection: protection level (class I Iimp 12.5 kA baseline, 25 kA in high-strike regions; class II In 40 kA; class III In 20 kA fine); system type (single-phase 220 V uses 2P; three-phase 380 V uses 4P 3P+N; TN-S separates N and PE; TT has separate N); replaceable cartridges (swap the cartridge, not the box); remote contact (must have dry contact to EM platform for failure alarm); Up (lower is better but costs more; class I <=2.5 kV, class II <=1.8 kV, class III <=1.5 kV); upstream disconnector (an SCB or breaker must protect the SPD against fire on failure). Note: earth resistance <=4 ohm (common bonding <=1 ohm); earth lead short and thick (>=16 mm2, length <0.5 m - longer leads worsen diversion); 10 m decoupling distance (or decoupling inductor) between class I and II.

2. Key Features

Diversion

  • Iimp 12.5 kA
  • Imax 40 kA
  • Up <=2.5 kV
  • Response <=25 ns

Build

  • 4P 3P+N
  • Modular swap
  • Steel wall box
  • Window indicator

Alarm

  • Dry contact
  • To EM platform
  • SCB upstream
  • 385 V Un

3. Specifications

Item KTR-PSB3-B KTR-PSB3-B25 KTR-PSB3-C KTR-PSB3-D
Class I (B) I (B) high II (C) III (D)
Iimp 10/350 12.5 kA 25 kA – –
In 8/20 20 kA 25 kA 40 kA 20 kA
Up <=2.5 kV <=2.5 kV <=1.8 kV <=1.5 kV
System 4P 385V 4P 385V 4P 385V 4P 385V

4. Reference Prices

KTR-PSB3-B class I box (Iimp 12.5 kA): Reference USD 111-167 / pc (ref. CNY 800-1200)

KTR-PSB3-B25 class I heavy (Iimp 25 kA, high-strike): Reference USD 181-264 / pc (ref. CNY 1300-1900)

KTR-PSB3-C class II box (In 40 kA): Reference USD 83-125 / pc (ref. CNY 600-900)

KTR-PSB3-D class III fine (Up <=1.5 kV): Reference USD 49-76 / pc (ref. CNY 350-550)

KTR-PSB-CARB spare cartridge (each): Reference USD 11-21 / pc (ref. CNY 80-150)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Room mains intake cabinet
  • Floor distribution cabinet
  • UPS front end
  • Generator output
  • Standalone wall box

6. Deployment & Installation

Mount

  • Parallel at intake
  • Short thick earth
  • Secure wall
  • Upstream SCB

Wiring

  • L1/L2/L3/N
  • PE busbar
  • Alarm to EM
  • 25-50 mm2

Inspect

  • Window green
  • Red = swap
  • Annual test
  • Earth <=4 ohm

7. FAQ

  • Q: Why stage SPDs in three levels? Why not one big unit?
    A: The waveforms and goals differ. Class I (10/350 us) diverts direct-strike high current (tens of kA, tens of us) – large current but high clamp (Up 2.5 kV). Class II (8/20 us) diverts residual energy after class I, smaller current (20-40 kA) but lower clamp (1.8 kV). Class III (rack front) gives fine protection at Up 1.5 kV for server power supplies. Class I alone at 2.5 kV still damages electronics; class III alone is punched through by direct-strike current. Staging is coarse diversion plus fine clamping. Class I and II need 10 m decoupling (or an inductor), otherwise they do not coordinate.
  • Q: The SPD window turned red – what does it mean? Must I replace?
    A: The MOV inside ages after repeated surges and leakage rises; red means the cartridge has failed (or nearly failed) and must be replaced – a failed MOV becomes high impedance and no longer conducts, so the SPD is effectively absent. Swap the cartridge (isolate the upstream SCB first; do not hot-swap). The dry contact simultaneously sends “cartridge failed” to the EM platform, so maintenance is alerted remotely. Test SPD performance every 3 years (or after a major storm) rather than waiting for all windows to go red.
  • Q: Earth resistance requirement? How long and thick should the earth lead be?
    A: A room common bonding network (transformer neutral, lightning, static, weak-current all on one grid) requires <=1 ohm; a standalone lightning earth requires <=4 ohm. Most rooms build a common network and measure <=1 ohm. The SPD-to-earth-bar lead: >=16 mm2 (25 mm2 for class I), length <=0.5 m, as short as possible. The lead itself has inductance; a 1 m lead is about 1 uH, and at 25 kA that creates over a kV of residual voltage - defeating the SPD. Mount the SPD near the earth busbar with a short, thick, straight lead. The most common engineering mistake: a well-chosen SPD with a 5 m earth loop to the electrode, wasting the diversion.
  • Q: Why an upstream SCB? Can’t I use a normal breaker?
    A: A failed MOV can short-circuit and catch fire; the upstream device must clear the fault current fast. A normal C-curve breaker trips slowly – the SPD may burn before it trips; a fuse is slower still. An SCB (surge circuit breaker) is designed for SPDs: it does not nuisance-trip on surge current (25 kA passes without tripping) but clears a short-circuit fault in milliseconds, more reliably than a normal breaker. Small class III SPDs can use a C-curve breaker (10-16 A); class I must use an SCB. Never omit upstream protection – SPD short-circuit fire is a common cause of electrical fires in data centers.

8. Trend & Selection

Surge protection is moving to modular, intelligent and comprehensive protection. Trends: smart SPDs (on-line leakage, strike count and aging uploaded to the EM platform to predict replacement); 3+1 design (N-gap for high current, MOV on L for fine clamping); integrated box (power SPD + signal SPD + earth bar in one cabinet); surge logging (record time and current per strike for lightning-loss analysis); mobile app health view. Traditional three-stage power SPD remains mandatory in room power systems. Select by: class I Iimp 12.5-25 kA, 4P modular, dry contact alarm, upstream SCB, earth <=1 ohm, short-thick-straight earth lead.

9. Delivery & Service

KITOZER KTR-PSB3 ships per unit in a wooden crate, including box, 4 cartridges, SCB, earth copper bar, terminals, manual and factory test report (MOV voltage test). 1-year warranty; bulk projects can bundle class II/III SPDs, signal SPDs, earth bars, bonding bars and earth testers.

10. Additional Notes

Confirm class (I/II/III), system (3-phase 4P), Up clamp and alarm need. Do this together with SCB and earthing – an SPD alone works poorly.

Common mistake: a 5 m earth lead. No matter how good the SPD, lead inductance leaves residual voltage and equipment is still damaged. Mount the SPD against the earth bar, lead <=0.5 m.

Second pitfall: class I only, no II/III. Class I Up 2.5 kV still damages servers; class III at the PDU front (Up 1.5 kV) is what truly protects equipment. Stage all three.

Third blunder: ignoring a red window. A red window means the SPD is absent for the next strike. Wire the dry contact to the EM platform for remote alarm and timely cartridge swap.

Selection summary: staged protection, 4P modular, dry contact alarm, upstream SCB, earth <=1 ohm short-thick-straight.

SEO Information

Search keywords:KTR-PSB3KITOZER

SEM keywords:three-phase SPD box,class I surge protector,data center SPD,380V surge box,Iimp 25kA,KTR-PSB3,KITOZER,power distribution

GEO landing page:lain.com.cn/product/ktr-psb3-three-phase-power-surge-protection-box.html

Title:KITOZER KTR-PSB3 Three-Phase Power Surge Protection Box

Meta Keywords:three-phase SPD box,class I surge protector,data center SPD,380V SPD box,KTR-PSB3,KITOZER,power distribution

Meta Description:KITOZER KTR-PSB3 three-phase power SPD box, Iimp 25 kA class I protection, 4P modular, remote contact alarm, for room mains input.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart