Table of Contents
ToggleKITOZER KTR-THL4 Wall-Mount LCD Temp & Humidity Sensor
Brand: KITOZER Series: KTR-THL4 Category: Environmental Monitoring / Temp & Humidity
temp humidity sensorwall LCDRS485Modbusroom monitor

1. Overview
Temp/humidity sensors are the basic sensing nodes of data-center environmental monitoring. Too hot and servers throttle; too humid and condensation shorts; too dry and static builds up. A wall-mount LCD sensor integrates measurement, display and comms in a single 86-box panel — an LCD shows live values on site while RS485 uploads data to the DCIM platform. It mounts on the room wall: inspectors read it at a glance; the platform reads it remotely.
The KITOZER KTR-THL4 is a wall-mount LCD temp/humidity sensor with a digital probe: temp -20℃~+60℃, ±0.5℃; humidity 0~100%RH, ±3%RH. LCD shows temp and RH together, backlight configurable. RS485 with standard Modbus-RTU; baud 9600/19200; address 1~247. Power DC 12V/24V. ABS flame-retardant white case, 86-box mount.
In room environmental monitoring, KTR-THL4 wall-mounts at 1.5 m, away from outlets and corners; multiple sensors distribute by rack zone on a hand-in-hand RS485 bus to the host. The LCD is softer than LED and can show temp, RH, time and alarm status. It is the eye of the environmental network — temp/RH drives precision-AC control, alarm thresholds and PUE analysis.
2. Key Features
Measurement
- Temp -20℃~+60℃, ±0.5℃.
- RH 0~100%RH, ±3%RH.
- Resolution 0.1℃/0.1%RH.
- Response ≤15 s.
Display & comms
- LCD, temp+RH together, backlight configurable.
- RS485 Modbus-RTU.
- Baud 9600/19200.
- Address 1~247 (DIP/software).
Construction
- 86-box wall mount.
- Power DC 12V/24V.
- ABS flame-retardant white.
- Internal probe (external option).
3. Specifications
| Item | KTR-THL4 |
|---|---|
| Temp range | -20℃~+60℃ (±0.5℃) |
| RH range | 0~100%RH (±3%RH) |
| Comm | RS485 Modbus-RTU |
| Display | LCD (temp+RH together) |
| Power | DC 12V/24V |
| Mount | 86-box wall |
| Address | 1~247 |
| Case | ABS flame-retardant |
4. Reference Prices
KTR-THL4 wall LCD temp/RH sensor (RS485 Modbus): Reference USD 13~25 (ref. CNY 90~180 at ~7.2)
Reference only; final quote applies. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Server room temp/RH monitoring.
- Electrical/UPS room environment.
- Warehouse, archive rooms.
- Lab, cleanroom monitoring.
- Museum HVAC.
6. Installation & Maintenance
Installation
- 86-box at 1.5 m; away from outlets/corners.
- Hand-in-hand RS485: DATA+/DATA- matched.
- Power DC 12V/24V; no reverse polarity.
- Set unique address.
- Fit 120Ω terminator at bus end.
- Add device in host; read registers.
- Set upper/lower alarm thresholds.
Maintenance
- Clean probe; no dust.
- Calibrate RH with saturated salt.
- Check A/B not reversed.
- Verify LCD backlight.
- Add signal SPD at line entry.
7. FAQ
- Q: How many sensors per bus?
A: Theoretically 32 (128 with repeaters); practically ≤20. Unique address each. - Q: Where to mount?
A: At a representative 1.5 m position, away from AC outlets (direct airflow reads low), corners (stagnant air) and doors (swing). - Q: LCD vs LED display?
A: LCD is soft, shows characters/time/status; LED is bright and far-readable but digits only. Choose LCD for duty rooms/inspection, LED for long-distance viewing. - Q: How to read Modbus?
A: Standard Modbus-RTU: temp and RH each hold a register (e.g. 40001 temp, 40002 RH); see manual.
8. Trend & Selection
Room DCIM moves toward multi-parameter fusion (temp/RH + leak + smoke + current); RS485 remains mainstream, with LoRa/NB-IoT emerging for dispersed sites. LCD on-site display improves inspection. Choose RS485 Modbus; ±0.5℃; LCD wall display; representative position; unique address; bus terminator.
9. Delivery & Service
KITOZER provides sensor sizing: based on point count, mounting positions and comm distance, we configure KTR-THL4 quantity and bus topology. Bundled with DCIM hosts, precision AC and leak detection. Delivery includes sensor, box and manual. Warranty covers calibration and comms commissioning.
10. Additional Notes
A common pitfall is mounting next to an AC outlet. Direct cold air reads 2~3℃ low, tricking the AC into stopping while other racks overheat. Mount away from outlets.
Another pitfall is reversed RS485 A/B. Reversed, the whole bus dies. Match DATA+(A)/DATA-(B) by label.
Selection summary: RS485 Modbus; LCD wall display; ±0.5℃; representative position; away from outlets; unique address; terminator. It is the room’s thermometer — accurate measurement makes AC and alarms reliable. Place one in each hot and cold aisle.
Keep the probe at least 5 cm off the wall for air circulation.
SEO Information
Search keywords:KTR-THL4KITOZER
SEM关键词:temperature humidity sensor, wall LCD temp humidity, data center temp humidity, RS485 transmitter, LCD humidity display, KTR-THL4, KITOZER
GEO landing page:lain.com.cn/product/367-temp-hum-lcd-ktr-thl4.html
Title:KITOZER KTR-THL4 Wall-Mount LCD Temp & Humidity Sensor
Meta Keywords:temperature humidity sensor, wall LCD temp humidity, data center temp humidity, RS485 transmitter, LCD humidity display, KTR-THL4, KITOZER
Meta Description:KITOZER KTR-THL4 wall-mount LCD temp/humidity sensor, RS485 Modbus, LCD shows temp and RH together, ±0.5℃, 86-box mount, for server room, electrical room and warehouse monitoring.
Anchor: KITOZER by Guangzhou Laian · KITOZER products