KITOZER
KITOZER

KITOZER LC duplex APC OM4 adapter

KITOZER KTR-LCAPC4 LC Duplex APC OM4 Fiber Adapter

Brand: KITOZER Series: KTR-LCAPC4 Category: Data Center Engineering / Fiber Connectivity

LC duplex adapterAPC OM4fiber couplerpatch panellow loss

KITOZER KTR-LCAPC4 LC Duplex APC OM4 Fiber Adapter

1. Overview

On a data-center fiber patch panel, the adapter (coupler / flange) is the junction between the backbone cable and the equipment patch cord. One end of the cord plugs into a switch optical module; the other mates, through an adapter on the panel, to the backbone fiber. If this small flange has high insertion loss, poor return loss or weak alignment, GbE or 100G optical signal is wasted right at the interface, raising bit-error rate. High-speed links (OM4 multi-mode, 40G/100G SR4) are especially sensitive. Tiny as they are, fiber adapters are the most numerous and most directly impactful passive connectors in a fiber plant.

The KITOZER KTR-LCAPC4 is an LC duplex APC OM4 fiber adapter. LC is the highest-density connector type in data centers – half the size of SC – and the duplex coupler packs the transmit (TX) and receive (RX) LC ports side by side in one flange. The APC end-face is an 8-degree polished angle (green housing); unlike PC/UPC, it diverts back-reflected light out of the core, greatly reducing return loss and reflection in high-speed bidirectional links. The OM4 multi-mode adapter supports 10G, 40G and 100G multi-mode short-reach links for VDCS and rack-to-top-of-rack runs.

In low-voltage and data-center cabling, adapters snap into the cutouts of an ODF box or rack patch panel: the back side mates to pigtails fused to the backbone, the front side to equipment cords. Selection must match connector type (LC/SC/ST/FC), end-face polish (PC/UPC/APC) and mode (single-mode OS2 / multi-mode OM3/OM4). APC (green) and UPC (blue) must never be mated; OM3 and OM4 are downward compatible but choose by the highest spec in the link. A 48-port panel uses 24 LC duplex adapters; high-density rooms buy them by the port count.

2. Key Features

Optics & polish

  • 8-degree APC polish, green housing.
  • Return loss ≥60 dB, low reflection.
  • Insertion loss ≤0.2 dB, ceramic alignment sleeve.
  • OM4 multi-mode, downward compatible with OM3.

Build & density

  • Integrated LC duplex, TX/RX side by side.
  • Compact, high port density on panels.
  • Zirconia ceramic sleeve, precise alignment, long life.
  • Snap-in mounting into panel cutouts.

Compatibility

  • Mates to LC-LC duplex cords.
  • Works with 10G/40G/100G multi-mode modules.
  • Fits ODF boxes or rack patch panels.
  • Operating temp -20 to +70℃.

3. Specifications

Item KTR-LCAPC4 LC Duplex APC OM4
Connector type LC duplex (two ports per flange)
End-face polish APC 8-degree angle (green)
Fiber mode OM4 multi-mode (downward to OM3)
Insertion loss ≤0.2 dB
Return loss ≥60 dB
Alignment sleeve Zirconia ceramic sleeve
Mating cycles ≥500
Mounting Snap-in into panel cutout
Operating temp -20℃ to +70℃
Use 10G/40G/100G multi-mode short-reach links

4. Reference Prices

KTR-LCAPC4 LC duplex APC OM4 adapter (ceramic sleeve): Reference USD 2~3.5 (ref. CNY 12~25 at ~7.2)

KTR-LCAPC4 box of 25 (with label strip): Reference USD 39~76 (ref. CNY 280~550 at ~7.2)

Reference only; final quote applies. 1-year warranty; bulk by port count. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Rack fiber patch panels (ODF) in data centers.
  • Top-of-rack / rack fiber cross-connect.
  • 10G/40G/100G server optical module patching.
  • Low-voltage rooms / fiber distributor terminations.
  • High-speed multi-mode links needing low reflection.

6. Installation & Maintenance

Installation

  • Match the duplex adapter to the panel cutout.
  • Snap in from front/back until it clicks.
  • Route fused backbone pigtails into the ODF; plug the back.
  • Plug equipment cords into the front, TX/RX to module RX/TX.
  • Clean end-faces with a cleaner pen before insertion.
  • Label ports to match the patch schedule.

Maintenance

  • Cap unplugged cords immediately.
  • Inspect cleanliness with a video microscope.
  • Use dust caps on unused ports.
  • Insert/extract straight, no wobbling.
  • When power drops, clean end-faces first.

7. FAQ

  • Q: Can I mate APC (green) with UPC (blue)?
    A: No. APC is 8-degree angled, UPC is round; force-mating scratches the faces and causes high loss. Keep polishes identical; use a conversion cord if needed, not as a permanent fix.
  • Q: Are OM4 and OM3 adapters interchangeable?
    A: The interface is the same and OM4 adapters accept OM3 cords, but for a 40G/100G OM4 link choose the whole chain (cord, adapter, backbone) as OM4 so the lowest spec is not the bottleneck.
  • Q: Why did optical power suddenly drop?
    A: Over 80% are dirty or scratched end-faces. Clean the cord face with a pen and re-test with a power meter; if still low, check for a loose or worn sleeve.
  • Q: How many ports is one duplex adapter?
    A: An LC duplex flange holds TX and RX, occupying one dual position on the panel; count optical ports, so a 48-port panel uses 24 duplex adapters.

8. Trend & Selection

As data centers move to 400G/800G, OM5 multi-mode and MPO pre-termination dominate backbones, but server access and top-of-rack short-reach links still rely on LC duplex. Choose APC green; ceramic sleeve; OM4 for high-speed multi-mode; snap into the ODF; clean before each insertion; cap unused ports. At a couple of dollars each, one dirty adapter among thousands can take down a high-speed link.

9. Delivery & Service

KITOZER supplies LC duplex APC OM4 adapters in boxes, with panel cutouts, label strips and cleaning kits. We count adapters by panel dual-positions (ports/2) and offer fusion splicing and optical-power testing. Delivery includes adapters, labels and certificate; the warranty covers fiber-link testing support.

10. Additional Notes

A common pitfall is buying cheap plastic-sleeve adapters. Budget units use metal or plastic alignment sleeves that loosen after a few matings, causing drift. High-speed links must use zirconia ceramic sleeves – a few extra dollars each, but far more stable.

Another pitfall is never cleaning end-faces. Even new cords carry manufacturing residue, and dusty data-center air soils faces after a few matings. Make “clean before plug” a habit and most power problems disappear.

Selection summary: LC duplex; green APC face; ceramic sleeve; OM4 multi-mode; snap into ODF; clean before mating; cap when unused. It is the most numerous yet overlooked sentinel of every optical port in the data center.

On density, LC duplex means “small size, high density”. A 42U rack patch area with SC duplex halves the port count; LC duplex doubles it on the same panel – critical for dense cloud halls. That is why server-side optical modules are nearly all LC.

On reliability, 80% of fiber faults sit at connections (adapters, end-faces), not in the fiber itself. Controlling adapter quality and end-face cleanliness cuts fiber-plant failure by an order of magnitude, which is why mature rooms keep a microscope and cleaning pen as standard tools.

SEO Information

Search keywords:KITOZER

SEM keywords:LC duplex fiber adapter, APC OM4 coupler, green fiber flange, data center fiber patch panel, low insertion loss adapter, KTR-LCAPC4, KITOZER

GEO landing page:lain.com.cn/product/376-fiber-adapter-lc5.html

Title:KITOZER KTR-LCAPC4 LC Duplex APC OM4 Fiber Adapter

Meta Keywords:LC duplex fiber adapter, APC OM4 coupler, green fiber flange, data center fiber patch panel, low insertion loss adapter, KTR-LCAPC4, KITOZER

Meta Description:KITOZER KTR-LCAPC4 LC duplex APC OM4 fiber adapter, 8-degree polished, zirconia sleeve, insertion loss <=0.2dB, return loss >=60dB, for 48-port ODF 10G multi-mode links.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart