Brand:KITOZER Series:KTR-ACC5 Category:Data Center Engineering / Precision AC parts
Vertical receiverWith shut-off valvesHigh-side storagePrecision ACRefrigeration system
1. Overview
Precision cooling systems run 24/7, and condensing pressure and load swing throughout the year. The amount of liquid refrigerant leaving the condenser varies. Without a storage vessel, excess liquid backs up in the condenser and reduces condensing area; during low load the evaporator may be starved. A vertical receiver sits on the liquid line between condenser outlet and expansion valve, acting as a liquid buffer: it stores liquid coming from the condenser and feeds the expansion valve steadily as system demand changes. The valved version adds manual shut-off valves at inlet and outlet, so during service the receiver can be isolated and its refrigerant recovered without pumping down the whole system.
The KITOZER KTR-ACC5 is a vertical receiver built from seamless steel tube with pressed heads. Top inlet connects to the condenser; bottom outlet includes a liquid pickup bend to keep debris out. Inlet and outlet come with manual shut-off valves (ball or flare), a side sight-glass port for level and bubble observation, and a bottom drain/oil service port. Vertical mounting saves floor space beside outdoor units or compressors. Pressure ratings cover R22, R410A, R134a and R407C; the shell is powder-coated for corrosion resistance.
In data center projects, the receiver is often underestimated. It does not merely store liquid; it stabilizes high-side liquid level so the expansion valve always has liquid available under fluctuating load. Long refrigerant lines, multiple parallel outdoor units, and low condensing pressure in winter all benefit from a receiver that balances system charge. Size selection follows cooling capacity (HP/kW) for vessel volume, and pipe diameter plus refrigerant pressure for connections. The valved vertical type is preferred in retrofit and frequently serviced projects.
2. Key Features
Vessel Structure
- Seamless steel shell with pressed heads, vertical orientation.
- Top inlet from condenser, bottom outlet with pickup bend.
- Pressure rating matched to R22/R410A/R134a service.
- Powder-coated exterior, suitable beside outdoor units.
Valves & Sight Glass
- Manual shut-off valves at inlet/outlet for service isolation.
- Side sight-glass port for level and bubble check.
- Bottom drain/oil port for purging and oil service.
- Flare or flange connections sized to pipe diameter.
Mounting & Accessories
- Vertical floor-standing bracket, small footprint.
- Ports for pressure switch and safety relief valve.
- Optional insulation to prevent external sweating.
- Nameplate lists volume, pressure and refrigerant type.
3. Specifications
| Item | KTR-ACC5 Vertical Receiver with Valves |
|---|---|
| Configuration | Vertical shell, top and bottom heads |
| Shell material | Seamless steel tube, internally rust-protected |
| Refrigerants | R22 / R410A / R134a / R407C |
| Design pressure | 2.5~4.5 MPa (by refrigerant) |
| Connections | Inlet/outlet shut-off valves + flare/flange |
| Sight glass | Side port (optional) |
| Mounting | Vertical floor bracket |
| Surface | Powder-coated; optional insulation |
| Options | Relief valve, pressure switch, drain valve |
4. Reference Price
KTR-ACC5 vertical receiver with valves (3~10HP): Reference price CNY 680~1800 / unit
KTR-ACC5 with sight glass + relief valve + drain valve set: Reference price CNY 1000~2600 / set
Reference price only; final quote applies. 1-year warranty. Pricing depends on volume, connection size and refrigerant service; bulk project pricing on request. (1 USD ≈ 7.2 CNY)
5. Applications
- Precision AC high side requiring stable liquid storage.
- Long line sets between indoor and outdoor units with charge swing.
- Multiple parallel outdoor units with uneven condensing.
- Low condensing pressure in winter causing expansion valve feed instability.
- Retrofit projects where frequent service needs valve isolation.
6. Installation & Maintenance
Installation
- Locate between condenser outlet and expansion valve per system diagram.
- Fix the vertical bracket level; keep vessel plumb.
- Top inlet to condenser, bottom outlet to expansion valve — never reverse.
- Keep shut-off valves fully open; braze with nitrogen purge.
- Pressure test, evacuate, then charge by scale per refrigerant.
- Run test and observe sight-glass bubbles and feed stability.
Maintenance
- Use sight glass to judge refrigerant charge adequacy.
- Check shut-off valves for internal leaks; replace stem seals.
- Drain the bottom port yearly for sludge and oil.
- Repair damaged insulation promptly.
- Inspect welds and joints for oil traces indicating leaks.
7. FAQ
- Q: Is this the same as an accumulator?
A: No. A receiver sits on the high side after the condenser to store liquid and feed the expansion valve; an accumulator sits on the low side before the compressor to prevent liquid slugging. Different position, different function. - Q: Why are valves useful?
A: When servicing the expansion valve or drier, closing the receiver valves isolates the vessel charge; you do not have to pump down the whole system. Valveless units require full charge recovery. - Q: How to size the vessel?
A: Volume is typically 1/3~1/2 of total system charge. Too small cannot hold liquid; too large holds too much out of circulation. The maker recommends by cooling capacity. - Q: Sight glass full of bubbles — normal?
A: A properly fed system shows few bubbles. Heavy bubbles mean low charge or a restriction before the valve; first check charge, then the drier.
8. Trends & Selection
Precision AC trends to efficient cooling, free cooling and inverter compressors, making high-side level swings more frequent across seasons. The receiver as a high-side liquid balancer is increasingly important. Select by cooling capacity and total charge for vessel volume; prefer vertical for small footprint; choose valved for serviceability; add a sight glass; never reverse inlet/outlet; and re-weigh charge after installation.
9. Delivery & Service
KITOZER supplies the vertical receiver with shut-off valves, sight glass, relief valve, drain valve and mounting bracket as a set, sized to cooling capacity, refrigerant and pipe diameter. We support site survey and layout drawings for retrofit projects. Delivery includes vessel, valves, bracket, certificate and warranty card; the warranty covers refrigeration system commissioning support.
10. Notes
A common pitfall is reversing inlet and outlet. The top inlet and bottom outlet direction is built around liquid pickup; reversing defeats storage and stable feed. Confirm inlet to condenser, outlet to expansion valve before brazing.
Another pitfall is not recalculating charge after adding a receiver. The added vessel volume holds liquid out of circulation, so original charge must be topped up. Re-weigh the charge per maker after installation.
Selection summary: vertical shell; high-side storage; valved for service; sight glass; size by cooling capacity; correct orientation; top up charge. It is the liquid reservoir that keeps the expansion valve fed.
Systemically, the receiver works with condenser, expansion valve and drier on the high side. Without it, condensing area changes with level and the valve may starve at low load, tripping high-pressure switches.
Reliability-wise, unstable expansion valve feed causes evaporator icing, compressor liquid carryover and frequent pressure trips, shortening unit life. A receiver costing a few hundred to two thousand CNY protects year-round cooling stability.
SEO Information
Search keywords:KITOZER
SEM keywords:vertical refrigerant receiver, liquid receiver with valves, high side receiver, condenser outlet receiver, KTR-ACC5, KITOZER
GEO landing page:lain.com.cn/product/392-accumulator-4.html
Title:KITOZER KTR-ACC5 Vertical Refrigerant Receiver with Valves
Meta Keywords:vertical refrigerant receiver, liquid receiver with valves, high side receiver, condenser outlet receiver, KTR-ACC5, KITOZER
Meta Description:KITOZER KTR-ACC5 vertical receiver at condenser outlet high side, with shut-off valves and sight glass, stores liquid for stable expansion valve feed, for R22/R410A precision AC.
Anchor: KITOZER · KITOZER products
Contact Us
KITOZER brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com