ToggleKITOZER KTR-ACC6 Horizontal Refrigerant Accumulator with Sight Glass
Brand:KITOZER Series:KTR-ACC6 Category:Data Center Engineering / Precision AC parts
Horizontal receiverSight glassRefrigeration loopPrecision AC
1. Overview
Data center precision air conditioners run non-stop year-round, and the refrigerant flow they need changes with heat load. At full load in summer the evaporator needs more liquid refrigerant; at low load in winter, excess refrigerant has nowhere to go, causing high condenser level and liquid slugging of the compressor. Installed between the condenser outlet and the expansion valve, the accumulator acts as a liquid buffer tank, storing excess refrigerant as liquid and feeding it back to the expansion valve when needed, keeping the cycle at optimum charge. It is an unnoticed but essential component in the loop.
The KTR-ACC6 series is a horizontal accumulator made from welded seamless steel pipe with corrosion-resistant coating, compatible with R22, R410A, R134a and other common refrigerants. One end has a vapor return port and a liquid outlet; the bottom has a service port and drain; the side integrates a sight glass. Staff can judge refrigerant charge by observing bubbles in the glass. The horizontal form takes little floor space and fits under or beside the AC unit, piped in series with condenser, drier and expansion valve on the high-pressure liquid line.
Selection considers volume (matched to cooling capacity), port size and connection (weld/flange), refrigerant type, working pressure and sight-glass inclusion. Bigger is not better: too large traps refrigerant and harms oil return; too small lacks buffering. General sizing is 20-30% of total charge. Install so the outlet liquid line stays submerged to prevent vapor reaching the expansion valve.
2. Key Features
Structure & material
- Seamless steel shell, pressure-rated design.
- Horizontal form, small footprint.
- Corrosion-resistant painted finish.
- Bottom service and drain ports.
Sight-glass viewing
- Integrated sight glass shows liquid level.
- No bubbles = correct charge.
- Heavy bubbles = low charge, needs topping up.
- Some models include moisture indicator.
Ports & connection
- Vapor return from condenser outlet.
- Liquid outlet to drier/filter.
- Port sizes matched to piping.
- Brazed connection, reliable seal.
3. Specifications
| Item | KTR-ACC6 Horizontal Accumulator |
|---|---|
| Form | Horizontal pressure vessel |
| Nominal volume | 6L / 10L / 14L (by capacity) |
| Refrigerant | R22 / R410A / R134a / R407C |
| Design pressure | Low 3.0 MPa / High 4.5 MPa |
| Sight glass | With moisture indicator |
| Port size | OD 12-22 mm (matched) |
| Connection | Brazed |
| Operating temp. | -20 to +65 C |
| Mounting | Horizontal bracket |
4. Reference Prices
KTR-ACC6 6L horizontal accumulator (sight glass): Reference USD 49~94 (ref. CNY 350~680 at ~7.2)
KTR-ACC6 10L horizontal accumulator (sight glass): Reference USD 67~122 (ref. CNY 480~880 at ~7.2)
KTR-ACC6 14L horizontal accumulator (sight glass): Reference USD 86~153 (ref. CNY 620~1100 at ~7.2)
Reference only; final quote applies. 1-year warranty. Ports matched to unit. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- High-pressure loops of precision AC outdoor units.
- Constant-temperature/humidity AC refrigerant cycles.
- Commercial VRF and chiller systems.
- Cold storage and refrigeration loops.
- Equipment needing stable liquid feed.
6. Installation & Maintenance
Installation
- Match volume to cooling capacity.
- Mount horizontally on bracket under/beside unit.
- Inlet to condenser outlet; outlet to drier.
- Nitrogen-purge during brazing to prevent oxide.
- Evacuate then charge by weight.
Maintenance
- Check sight glass regularly for charge level.
- Heavy bubbles = low charge; find leak and top up.
- Discoloring indicator = system wet; change drier.
- Inspect shell for rust or oil (oil = leak).
- Drain oil/moisture from bottom port periodically.
7. FAQ
- Q: Accumulator vs suction-line accumulator?
A: The liquid receiver is on the high side, storing liquid to buffer feed. The suction accumulator is on the low side, separating liquid at compressor inlet to prevent slugging. Different positions and roles. - Q: Is constant bubbling normal?
A: A few bubbles at startup or load swing is normal; steady heavy bubbles means low charge and a leak to find. - Q: Why not choose a bigger tank?
A: Oversize traps refrigerant and harms oil return, causing compressor oil starvation. Size to 20-30% of charge. - Q: What does the indicator color mean?
A: Green = dry; yellow = wet. Yellow means drier saturated and needs replacement.
8. Trend & Selection
Precision AC trends toward efficiency, inverter drives and refrigerant transition; receivers evolve toward smaller volume and higher integration (sight glass + drier combined). Size to capacity; confirm refrigerant; choose sight-glass model for inspection; match port size; keep outlet liquid seal. Though small, it is the liquid reservoir that stabilizes the loop.
9. Delivery & Service
KITOZER supplies the KTR-ACC6 series with optional sight glass, drier and shut-off valves. Delivery includes accumulator, mounting bracket, certificate and warranty card. Port size and volume matched to unit model.
10. Notes
A common pitfall is reversing inlet and outlet. The vapor inlet goes to the condenser; the liquid outlet goes to the expansion valve. Reversed, liquid returns to the condenser and cooling stops.
Another pitfall is charging without evacuation. Air and moisture cause ice blockage and corrosion. Always evacuate to -0.1 MPa before charging by weight.
Selection summary: horizontal with sight glass; 20-30% of charge; refrigerant matched; nitrogen-purge brazing; outlet liquid seal; inspect sight glass regularly. It is the stabilizer of the cooling loop.
Systemically, the receiver answers “where does the refrigerant go”. Under load swings, excess charge needs a safe home, and the compressor must not eat liquid. The receiver is that safe home.
Reliability-wise, room AC runs 24/7; a small loop part failing can trigger a high-temp alarm. The receiver costs little, yet without enough buffering, unstable feed causes frequent cycling and higher energy use.
SEO Information
Search keywords:KITOZER
SEM keywords:refrigerant accumulator, horizontal receiver, sight glass receiver, precision AC parts, KTR-ACC6, KITOZER
GEO landing page:lain.com.cn/product/408-accumulator-5.html
Title:KITOZER KTR-ACC6 Horizontal Refrigerant Accumulator with Sight Glass
Meta Keywords:refrigerant accumulator, horizontal receiver, sight glass, precision AC, KTR-ACC6, KITOZER
Meta Description:KITOZER KTR-ACC6 horizontal refrigerant accumulator with sight glass, stores excess refrigerant in precision AC loops, stabilizes flow, integrates liquid indicator, various port sizes.
Anchor: KITOZER by Guangzhou Laian · KITOZER products
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com