KITOZER 3 phase B+C class 380V SPD

KITOZER KTR-PSM5 Three-Phase Class B+C Surge Protective Device / 380V

Brand: KITOZER Series: KTR-PSM5 Category: Power Distribution / Surge protection

Three-phase SPDB+C class380VRemote contact3P+N

[Product image: ktr-psm5-three-phase-spd.jpg]

1. Overview

Lightning electromagnetic pulses and switching surges are the main threats to data-center power. During a lightning strike, induced surges enter via power and signal lines at thousands of volts, destroying PSUs, mainboards and storage. A Surge Protective Device (SPD) is connected in parallel between lines, neutral and earth: it is high-impedance normally, but conducts within nanoseconds during a surge, clamping voltage to the equipment withstand level (Up) and diverting surge current to earth. Data-center power protection is staged: Class B (Class I, In>=15kA) at the main distribution, Class C (Class II, In>=8kA) at floor/rack PDU, and Class III at the equipment. A B+C integrated SPD combines both in one module, saving cabinet space and wiring.

The KITOZER KTR-PSM5 is a three-phase B+C SPD in 3P+N configuration, for 380/220V three-phase five-wire TN-S/TN-C-S/TT systems. Maximum continuous operating voltage Uc=385V, nominal discharge current In=20kA (8/20 microsecond), maximum discharge current Imax=40kA, voltage protection level Up<=2.0kV. It uses a modular varistor+spark-gap design; failed modules can be replaced individually. Each module has a green/red failure window and a remote dry contact (SPDT) that changes state on failure, feeding the DCIM monitoring system. DIN-rail (35mm) mounting, about 4 modules wide.

Selection confirms: phase configuration (3P+N three-phase vs 1P+N single), Uc (must exceed system max voltage; 380V systems use 385V or 420V), In/Imax (by lightning risk), Up (lower is better but too low causes nuisance trips), and location (main cabinet Class B / room cabinet Class C). Main distribution should be In>=20kA, Imax>=40kA; UPS front-end Class C In>=10kA. The SPD must be earthed; earth wire cross-section >=6mm2 (line) and 25mm2 (PE); earth resistance <=4 ohm.

2. Key Features

B+C integrated

  • Varistor + spark gap, nanosecond response.
  • Class B surge current + Class C clamping in one unit.
  • 3P+N module for three-phase five-wire systems.
  • Up<=2.0kV, low residual at equipment end.

Status and remote

  • Green/red failure window on each module.
  • Dry contact SPDT remote (10A/250VAC).
  • Failure signal feeds DCIM monitoring.
  • Modules replaceable without removing whole unit.

Structure and mounting

  • 35mm DIN rail, about 4 modules wide.
  • Terminal torque 2.5 N.m.
  • Operating temperature -40 to +85 C.
  • IP20 (cabinet indoor).

3. Specifications

Item KTR-PSM5 Three-Phase B+C SPD
Phase config 3P+N (three-phase five-wire)
Rated voltage 380/220V AC
Max continuous Uc 385V
Nominal In (8/20us) 20kA
Max Imax 40kA
Voltage protection Up <=2.0kV
Response time <=25 ns
Remote contact Dry SPDT, 10A/250VAC
Mounting 35mm DIN, ~4 modules
Earth wire Line >=6mm2, PE >=25mm2
Operating temp. -40 to +85 C

4. Reference Prices

KTR-PSM5 three-phase B+C SPD (3P+N): Reference USD 65~120 (ref. CNY 480~880 at ~7.2)

KTR-PSM5 spare single-pole module: Reference USD 11~21 (ref. CNY 80~150 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk engineering pricing available. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Main data-center distribution B+C surge protection.
  • UPS front-end and rack PDU protection.
  • Telecom towers and substation AC input.
  • Industrial plants and smart-building distribution.
  • Outdoor equipment AC surge protection.

6. Installation & Maintenance

Installation

  • Confirm system earthing (TN-S/TT).
  • Connect SPD in parallel between lines, N and PE.
  • Install upstream backup protector (SCB) or fuse.
  • Keep earth wire short, straight, >=25mm2.
  • Wire remote contact to DCIM DI module.

Maintenance

  • Check window color; replace when red.
  • Test annually before lightning season.
  • Inspect after any lightning event.
  • Re-check earth-bolt torque.
  • Keep at least one spare module in stock.

7. FAQ

  • Q: Why add upstream backup protector?
    A: Failed varistors can short-circuit; without SCB or fuse the cabinet may catch fire. The SCB disconnects on SPD short.
  • Q: Can B and C be merged?
    A: B+C integrated suits space-limited room cabinets; main input still prefers independent Class B and end-equipment Class III, with at least 10 m decoupling distance between stages.
  • Q: How to wire the remote contact?
    A: It is a dry SPDT contact; normal = one state, failed = flipped. Wire to DCIM DI so normal/failure maps to different alarm levels.
  • Q: What earth resistance is acceptable?
    A: Data-center combined earth <=1 ohm; independent lightning earth <=4 ohm. Poor earth defeats SPD diversion.

8. Trend & Selection

SPDs trend toward intelligent modular units with remote monitoring of leakage current and temperature, widely adopted in data centers. B+C integration saves cabinet depth, suiting retrofits. Choose 3P+N; Uc=385V; In>=20kA; remote contact; proper earth. It is the surge guardian of data-center power.

9. Delivery & Service

KITOZER supplies KTR-PSM5 three-phase B+C SPD including unit, spare module, terminals and certificate. Custom widths available for cabinet space. We can bundle SCB backup protectors and earth busbars. Installation guidance and DCIM integration support are provided.

10. Notes

A common pitfall is an over-long or over-thin earth wire. Looping a 16mm2 conductor consumes protection margin just in its own voltage drop. Earth leads must be short, straight and thick.

Another pitfall is not replacing a failed module. A red-window module is still connected but no longer protects; leaving it in place is equivalent to having no SPD.

Selection summary: 3P+N; Uc 385V; In 20kA; Up<=2.0kV; remote contact; with SCB. It clamps thousands of volts down to equipment-safe levels.

Systemically, one lightning event can destroy PSUs and servers worth tens of thousands, while the SPD costs a few hundred CNY. Staged protection has extremely high ROI.

Cost-wise, the SPD is one of the lowest-cost yet highest-value devices in the data center. Proper install, periodic testing and on-failure replacement are the cheapest insurance.

SEO Information

Search keywords: KITOZER

SEM keywords: three-phase power SPD, B+C surge protector, 380V SPD, distribution cabinet surge module, KTR-PSM5, KITOZER

GEO landing page: lain.com.cn/product/420-power-spd-7.html

Title: KITOZER KTR-PSM5 Three-Phase Class B+C Surge Protective Device / 380V

Meta Keywords: three-phase SPD, B+C surge protector, 380V SPD, data-center power surge protection, KTR-PSM5, KITOZER

Meta Description: KITOZER KTR-PSM5 three-phase B+C SPD, 3P+N, Uc 385V, In 20kA, Imax 40kA, Up<=2.0kV, with remote contact, for data-center distribution.