Table of Contents
ToggleKITOZER KTR-BAT24 12V24Ah VRLA Battery / Access-control UPS
Brand: KITOZER Series: KTR-BAT24 Category: Power Distribution / Battery
12V24AhVRLA AGMMaintenance-freeAccess UPSEmergency light
1. Overview
Batteries are the last line of defense for UPS, access controllers, emergency lighting and fire-alarm systems. When mains fails, the battery converts chemical DC energy to keep loads running for minutes to hours, protecting data, door locks and emergency lights. Valve-Regulated Lead-Acid (VRLA) batteries, with maintenance-free operation, no leakage and flexible mounting (except inverted), are widely used for data-center and building backup power. The AGM (Absorbent Glass Mat) starved-electrolyte design absorbs acid in fiberglass mats; oxygen recombines internally so no water topping-up is needed under normal use.
The KITOZER KTR-BAT24 is a 12V 24Ah VRLA battery in AGM starved design. Six 2V cells are series-connected to 12V; rated capacity is 24Ah (20-hour rate, 10.5V cut-off). Float voltage is 13.5~13.8V/cell (25 C); equalize charge 14.4~14.7V/cell. Design float life is 5~8 years at 25 C; cycle life >=500 cycles at 100% depth of discharge. Self-discharge is <=3%/month at 25 C, so it can sit for 3 months before recharge. A built-in safety valve vents overcharge while remaining sealed normally. Terminals are M5/M6 bolts for lugs. Operating temperature -15 to +50 C; recommended 20~25 C.
Selection confirms: rated voltage (12V), capacity (Ah, by backup time and load), terminal type and mounting space. A single access controller typically needs one 12V24Ah for 4~8 hours backup; a small 1kVA UPS usually uses four 12V batteries in series for a 48V string, giving 10~30 minutes backup. Capacity formula: Ah = load W x backup hours / (inverter efficiency x battery cut-off V x inverter factor). Strings must use same brand, model and batch; never mix old and new batteries.
2. Key Features
AGM starved electrolyte
- Acid absorbed in fiberglass mat.
- Oxygen recombination, no water loss in use.
- Valve-regulated sealed, no leakage, mountable any way.
- Built-in safety valve vents on overcharge.
Long life
- 5~8 year float design life at 25 C.
- Cycle life >=500 at 100% DOD.
- Self-discharge <=3%/month at 25 C.
- Calcium-alloy grid, corrosion-resistant.
Electrical performance
- Rated 12V, 24Ah (20hr).
- Float 13.5~13.8V/cell at 25 C.
- Equalize 14.4~14.7V/cell.
- M5/M6 bolt terminals.
3. Specifications
| Item | KTR-BAT24 12V24Ah VRLA |
|---|---|
| Rated voltage | 12V (6x2V cells) |
| Rated capacity | 24Ah (20hr, 10.5V cut-off) |
| Design life | 5~8 yr float at 25 C |
| Cycle life | >=500 cycles at 100% DOD |
| Float voltage | 13.5~13.8V/cell at 25 C |
| Equalize voltage | 14.4~14.7V/cell |
| Self-discharge | <=3%/month at 25 C |
| Grid alloy | Pb-Ca |
| Terminal | M5/M6 bolt |
| Operating temp. | -15 to +50 C (rec. 20~25 C) |
| Weight | ~7.5 kg |
4. Reference Prices
KTR-BAT24 12V24Ah VRLA battery: Reference USD 25~45 (ref. CNY 180~320 at ~7.2)
KTR-BAT24 with cables and lugs: Reference USD 28~48 (ref. CNY 200~350 at ~7.2)
Reference only; final quote applies. 1-year warranty. Bulk engineering pricing available. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Access controllers and intercom backup power.
- Small UPS (1~3kVA) battery strings.
- Emergency lighting and fire-alarm backup.
- Security cameras and outdoor towers.
- Electric shutters and fire-linked power.
6. Installation & Maintenance
Installation
- Inspect for swelling or leakage on unpacking.
- Series same brand/model/batch batteries.
- Coat terminals with petroleum jelly; torque properly.
- Fix on rack; keep >=10 mm spacing for cooling.
- Measure open-circuit voltage before connecting; spread <=0.05V.
Maintenance
- Check float voltage monthly; equalize if spread >0.05V.
- Do a capacity verification discharge yearly.
- Keep room at 25 C; life halves per 10 C rise.
- Keep terminals clean and dry.
- Recharge stored batteries every 3 months.
7. FAQ
- Q: Can old and new batteries be mixed?
A: No. Internal resistance differs; series strings charge/discharge unevenly, over-charging/discharging the old ones and shortening whole-string life. - Q: Can a swollen battery still be used?
A: Swelling means internal gas buildup and failed valve; risk of cracking and leakage. Replace immediately. - Q: What float voltage is right?
A: 13.5~13.8V per 12V battery at 25 C. Too high over-dries; too low sulfates. Compensate ~3mV/cell per degree drop. - Q: How long do batteries last?
A: 5~8 years float at 25 C. Real-world life depends on temperature, DOD and charging; data centers typically replace at 3~5 years.
8. Trend & Selection
Backup power trends toward LiFePO4, but VRLA remains dominant in small-capacity access control and emergency lighting thanks to low cost, maturity and recycling. Data-center strings move toward smart cabinets with per-cell voltage and internal-resistance monitoring. Choose 12V24Ah sized by backup time; same batch in string; float at 25 C; verify discharge periodically. It is the energy reserve when mains fails.
9. Delivery & Service
KITOZER supplies KTR-BAT24 12V24Ah batteries including unit, certificate, warranty card and manual. We can configure series count per UPS string. Battery racks, cables and lugs are available as a set. Installation guidance and capacity-verification discharge service are provided.
10. Notes
A common pitfall is mixing batteries. Stringing a retired UPS battery with new ones drags down the whole set; new cells fail quickly too.
Another pitfall is high ambient temperature. Uncooled battery rooms at 40 C+ halve life. Battery rooms must be temperature-controlled.
Selection summary: 12V24Ah; AGM starved; 5~8 year float; same batch in string; anti-corrosion terminals; periodic verification. It keeps access control and UPS alive.
Systemically, the battery is the fastest-decaying part of a UPS. The UPS unit lasts 10 years but batteries need replacement at 3~5 years; verification discharge cannot be skipped.
Cost-wise, a 24Ah cell costs a few hundred CNY, a full string a few thousand. Compared with data loss from one mains outage, battery investment is negligible.
SEO Information
Search keywords: KITOZER
SEM keywords: 12V24Ah battery, VRLA sealed lead-acid, access-control UPS backup, AGM maintenance-free, KTR-BAT24, KITOZER
GEO landing page: lain.com.cn/product/421-battery-12v24.html
Title: KITOZER KTR-BAT24 12V24Ah VRLA Battery / Access-control UPS
Meta Keywords: 12V24Ah battery, VRLA AGM battery, access-control UPS battery, maintenance-free battery, KTR-BAT24, KITOZER
Meta Description: KITOZER KTR-BAT24 12V24Ah valve-regulated lead-acid battery, AGM starved-electrolyte, 5~8 year float design life, self-discharge <=3%/month, for access control and UPS.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com