KITOZER RS485 large display temp humidity sensor

KITOZER KTR-TH7 Data-Center Temp/Humidity Sensor with RS485 Display

Brand: KITOZER Series: KTR-TH7 Category: Environmental Monitoring / Temp & humidity

RS485 ModbusLED display+/-0.3CWall mountDCIM integration

[Product image: ktr-th7-rs485-temperature-humidity-sensor.jpg]

1. Overview

Data centers target 23 +/-1 C and 40 to 60% RH. Out-of-range conditions cause server throttling, condensation shorts or ESD damage. Temp/humidity sensors sample the room continuously and upload readings over RS485 to the DCIM platform; on alarm they trigger the AC or annunciate. A sensor with a large LED display lets staff see values at a glance in corridors or in front of racks.

The KITOZER KTR-TH7 is a data-center temp/humidity sensor using an imported Sensirion digital probe. Temperature accuracy +/-0.3 C (-10 to +60 C), humidity accuracy +/-2% RH. Large LED display shows temp and humidity. RS485 Modbus RTU at 9600/19200, address 1 to 247. Powered by DC12V/24V. Wall-mount ABS housing; probe is internal or on a 1.5 m extension. Alarm thresholds are set via keys; over-threshold triggers a relay output. Operating temp -20 to +60 C.

Selection confirms: accuracy (industrial grade +/-0.3 C / +/-2% RH), whether a display is needed, communication (RS485/Ethernet), remote probe, and power (DC12V/24V). Generally one sensor per 200 to 400 m2, placed in both hot and cold aisles. RS485 daisy-chain reaches 1200 m.

2. Key Features

Sensing accuracy

  • Sensirion digital probe.
  • Temp accuracy +/-0.3 C.
  • Humidity accuracy +/-2% RH.
  • Response time <=8 s.

Display and communication

  • Large LED numeric display.
  • RS485 Modbus RTU.
  • Baud 9600 / 19200.
  • Address 1 to 247.

Structure and alarm

  • Wall-mount ABS housing.
  • Internal probe or 1.5 m remote.
  • Threshold set via keys.
  • Over-threshold relay output.

3. Specifications

Item KTR-TH7 Temp/Humidity Sensor
Parameters Temperature + humidity
Temp accuracy +/-0.3 C (-10 to +60 C)
Humidity accuracy +/-2% RH
Temp range -20 to +60 C
Humidity range 0 to 100% RH
Display Large LED numeric
Communication RS485 Modbus RTU
Baud rate 9600 / 19200
Address 1 to 247
Power DC12V/24V
Probe Internal or 1.5 m remote
Alarm output Dry relay contact

4. Reference Prices

KTR-TH7 temp/humidity sensor (LED display): Reference USD 42~83 (ref. CNY 300~600 at ~7.2)

KTR-TH7 temp/humidity sensor (basic no display): Reference USD 21~42 (ref. CNY 150~300 at ~7.2)

KTR-TH7 remote probe extension (per meter): Reference USD 1.4~2.8 (ref. CNY 10~20 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. RS485 to DCIM integration. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Cold/hot aisle monitoring in data centers.
  • Power rooms and battery rooms.
  • Archive and storage room monitoring.
  • Lab and workshop logging.
  • Base stations and outdoor cabinets.

6. Installation & Maintenance

Installation

  • Wall-mount at 1.5 m height.
  • Avoid AC outlets and direct sun.
  • Daisy-chain RS485 to DCIM.
  • Power DC12V/24V.
  • Set address, baud, alarm thresholds.
  • Calibrate readings on the platform.

Maintenance

  • Calibrate annually against a standard source.
  • Clean probe filter.
  • Re-tighten RS485 terminals.
  • Check LED brightness.
  • Simulate alarm test.

7. FAQ

  • Q: How many sensors per room?
    A: Generally one per 200 to 400 m2, with points in both hot and cold aisles. Large rooms are zoned.
  • Q: Can the probe go inside a rack?
    A: Use a remote probe extension; place the probe at rack inlet and hang the display on the wall. This measures rack inlet conditions.
  • Q: How many sensors on one RS485 bus?
    A: Without repeater, 32 units; with 485 repeater, up to 128. Data centers typically use 10 to 20.
  • Q: What happens on out-of-range?
    A: Link to precision AC for temp/humidity control; relay output to alarm. The platform logs over-threshold curves for AC capacity analysis.

8. Trend & Selection

Environment monitoring trends toward networked, visual panels integrated with DCIM; LED displays aid walkthroughs. Choose industrial-grade +/-0.3 C; RS485 Modbus; LED display; place in hot and cold aisles; calibrate annually. It is the thermometer of the data center.

9. Delivery & Service

KITOZER supplies KTR-TH7 sensors including unit, power adapter, mounting bracket and certificate. Remote probes are supplied per meter. DCIM integration and commissioning are provided.

10. Notes

A common pitfall is mounting at an AC outlet. Outlet temperature is biased low and does not represent the room. Mount mid-aisle or in the return path.

Another pitfall is skipping calibration. After 1 to 2 years the probe drifts. Calibrate annually against a standard source.

Selection summary: +/-0.3 C / +/-2% RH; LED display; RS485 Modbus; DC12V/24V; relay alarm. It monitors the room in real time and alarms on over-range.

Systemically, one over-temperature event can throttle or crash a row of servers. The sensor costs a few hundred CNY and is the foundation of environment monitoring.

Cost-wise, a 2000 m2 room with 10 sensors totals about 5000 CNY — the smallest line item in the DCIM system.

SEO Information

Search keywords: KITOZER

SEM keywords: temperature humidity sensor, RS485 sensor, LED display, data-center environment monitoring, DCIM sensor, KTR-TH7, KITOZER

GEO landing page: lain.com.cn/product/431_temp_hum_7.html

Title: KITOZER KTR-TH7 Data-Center Temp/Humidity Sensor with RS485 Display

Meta Keywords: temperature humidity sensor, RS485 sensor, LED display, data-center environment monitoring, KTR-TH7, KITOZER

Meta Description: KITOZER KTR-TH7 data-center temp/humidity sensor, RS485 Modbus, large LED display, accuracy +/-0.3C / +/-2%RH, for environment monitoring.