ToggleKITOZER KTR-FL6 Rack Plinth / Suspended Ceiling Top Panel
Brand: KITOZER Series: KTR-FL6 Category: Data Center Engineering / Rack containment
Cold-rolled steelCold aisle containmentRaised plinthSuspended top panelModular
1. Overview
Micro-module data centers arrange racks into cold and hot aisles. Closing the cold aisle forces supply air in through rack fronts only, preventing hot/cold mixing and cutting AC energy. The rack plinth raises the whole row to create a bottom air-supply or cable space; the suspended top panel seals the aisle roof, stopping cold air from escaping upward. Plinth and top panel are the structural parts of containment, and although they neither light nor heat, they directly decide sealing quality and airflow efficiency.
The KITOZER KTR-FL6 includes rack plinths and suspended top panels in 1.5 mm cold-rolled steel with RAL7035 electrostatic powder coating. Plinth heights are 50/100/200 mm, chosen by under-floor cabling or raised supply-air requirements. The top panel hangs above the rack row and opens upward for top cabling and service. It pairs with a tempered-glass end door and a roof vent (fusible-link auto-open) for full containment. Plinth load >=1000 kg per row, suiting dense racks.
Selection confirms: row length (600/800 mm per bay), plinth height (50/100/200), whether the panel opens, end-door direction (left/right/sliding), fire vent requirement (70 C fusible link), and color (RAL7035). Design the whole row uniformly so plinth and panel match rack width and color for tight sealing.
2. Key Features
Structure and material
- 1.5 mm cold-rolled steel.
- Powder-coated, corrosion-resistant.
- Plinth load >=1000 kg/row.
- Bolted joints, field-adjustable.
Containment and airflow
- Raised base creates supply/cable space.
- Suspended panel seals the aisle roof.
- Tempered-glass end doors.
- No hot/cold mixing, energy saving.
Fire and service
- Roof vent opens at 70 C fusible link.
- Panel flips up for top cabling.
- Door locks for walk-through access.
- B1 flame-retardant.
3. Specifications
| Item | KTR-FL6 Plinth / Top Panel |
|---|---|
| 材质 | 冷轧钢板 1.5mm |
| 表面处理 | 静电喷塑 RAL7035 |
| 底座高度 | 50 / 100 / 200 mm |
| 顶板形式 | 吊装式可开启 |
| 封闭方式 | 冷通道天窗+端门 |
| 承载 | 底座≥1000kg/列 |
| 颜色 | 灰白色 RAL7035 |
| 适用机柜 | 600/800mm宽 标准19英寸 |
| 防火等级 | B1级阻燃 |
| 安装方式 | 螺栓拼接,现场可调 |
4. Reference Prices
KTR-FL6 rack plinth (100mm / 600 wide): USD 39~63 (ref. CNY 280~450 at ~7.2)
KTR-FL6 suspended top panel (per m2): USD 49~76 (ref. CNY 350~550 at ~7.2)
Cold aisle end door (glass): USD 250~445 (ref. CNY 1800~3200 at ~7.2)
Reference only; final quote applies. 1-year warranty. Row packages quoted separately. Bolt kit included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Micro-module cold aisle containment.
- Retrofit containment for existing rooms.
- High-density server rack rows.
- Raised-floor under-floor supply.
- Modular and containerized data centers.
6. Installation & Maintenance
Installation
- Mark the row baseline first.
- Bolt plinths bay by bay; level and align.
- Fix racks to the plinth.
- Hang the top panel on rack tops with hooks.
- Install end doors at both ends.
- Fit fusible-link roof vents.
Maintenance
- Check plinth bolts quarterly.
- Lubricate the flip-up hinges.
- Inspect door seals.
- Never remove the fusible link.
- Touch up powder-coat scratches.
7. FAQ
- Q: Which plinth height?
A: 50 mm for under-floor cabling; 100 to 200 mm for a plenum; 100 mm is the general default. - Q: Can the panel just rest on rack tops?
A: Not recommended. Uneven rack tops leak air and leave no cabling layer. Hanging seals the gap and reserves a cable space. - Q: How to reset the roof vent?
A: After fire actuation the link breaks and the vent opens. Reset by installing a new link; never substitute wire. - Q: Does containment raise noise?
A: Fans reflect inside the aisle. Add acoustic liner on the panel or use quieter fans.
8. Trend & Selection
Micro-modules trend toward prefabricated, quick-install packages; plinth and panel are factory-made structural parts bolted on site. Choose 1.5 mm steel; height by supply need; flip-up panel; glass end doors; 70 C fusible vents. It makes the cold aisle truly sealed and durable.
9. Delivery & Service
KITOZER ships KTR-FL6 plinths and panels row-packed, including bolts, seals and fusible links. On-site installation guidance is provided.
10. Notes
A common pitfall is not leveling the plinth. An uneven row leaves gaps in panel and door, letting cold air leak and weakening containment. Level every bay with a laser or level.
Another pitfall is owners removing fusible links “for convenience”. During a fire the vent will not open, smoke and heat accumulate, and fire code is violated. The link is a safety part and must never be removed.
Selection summary: cold-rolled steel; 100 mm plinth; flip-up suspended panel; glass end doors; 70 C fusible vents; RAL7035. It is the skeleton of the cold aisle.
Systemically, a well-sealed aisle reduces supply/return mixing losses and saves 10% to 20% on AC; the plinth/panel cost pays back in a year of electricity.
Cost-wise, a ten-bay row with plinth and panel runs 15 to 20 k CNY, but the efficiency gain and stable rack inlet temperature pay off for years.
SEO Information
Search keywords: KITOZER
SEM keywords: rack plinth, suspended ceiling panel, cold aisle containment, rack raised base, KTR-FL6, KITOZER
GEO landing page: lain.com.cn/product/434_rack_floor_5.html
Title: KITOZER KTR-FL6 Rack Plinth / Suspended Ceiling Top Panel
Meta Keywords: rack plinth, suspended ceiling panel, cold aisle containment, rack raised base, KTR-FL6, KITOZER
Meta Description: KITOZER KTR-FL6 rack plinth and suspended ceiling top panel, cold-rolled steel, cold-aisle containment kit for micro-module data centers.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com