Table of Contents
ToggleKITOZER KTR-LCOM6 Fiber Adapter / LC Duplex OM5 Multimode
Brand: KITOZER Series: KTR-LCOM6 Category: Data Center Engineering / Fiber connectivity
LC duplexOM5 MMF10/40GCeramic sleevePanel mount
1. Overview
As data centers upgrade to 40G/100G, OM5 wideband multimode fiber (WBMMF) is widely adopted because it supports SWDM wavelength division multiplexing over a single pair. A fiber adapter (coupler / flange) is the passive component in ODF patches and termination boxes that precisely aligns two ferrules, keeping insertion and return loss minimal.
The KITOZER KTR-LCOM6 is an LC duplex OM5 multimode adapter. It uses a flame-retardant plastic body with a zirconia ceramic sleeve for high alignment precision. The duplex housing integrates a pair of LC connectors for transmit/receive. Polished to PC/UPC, it works with OM1/OM2/OM3/OM4/OM5 multimode fibers and is interchangeable with LC-LC and LC-SC hybrid jumpers. Typical insertion loss is <=0.2 dB, return loss >=20 dB, and mating life >=1000 cycles.
Selection confirms: adapter type (LC duplex), mode (OM5 MMF), mounting (panel / rack), count (simplex / duplex / quad), color code (aqua for OM5), and whether dust caps are included. The KTR-LCOM6 is used in high-density ODF frames, wall-mount termination boxes, and rack fiber entry points. Pair it with OM5 LC-LC duplex jumpers to preserve mode bandwidth and loss budget.
2. Key Features
Precise alignment
- Zirconia ceramic sleeve, wear-resistant.
- Ferrule centering within 0.5 um.
- Typical insertion loss <=0.2 dB.
- Return loss >=20 dB.
OM5 compatibility
- Supports 850/953/1300 nm multi-wavelength.
- SWDM-ready.
- Backward compatible with OM3/OM4.
- Aqua housing for visual identification.
Structure and install
- Integrated LC duplex latch.
- Tool-less snap-in panel mount.
- Dust caps included.
- Flame-retardant PC, UL94 V-0.
3. Specifications
| Item | Specification |
|---|---|
| Adapter type | LC duplex |
| Fiber mode | OM1/OM2/OM3/OM4/OM5 MMF |
| Polish | PC/UPC |
| Sleeve | Zirconia ceramic |
| Insertion loss | Typ. <=0.2 dB |
| Return loss | >=20 dB |
| Mating life | >=1000 cycles |
| Body | Flame-retardant PC, UL94 V-0 |
| Color | Aqua |
| Operating temp | -20 to 70 C |
4. Reference Prices
KTR-LCOM6 LC duplex OM5 adapter (each): USD 1.1~2.1 (ref. CNY 8~15 at ~7.2)
KTR-LCOM6 12-port adapter panel: USD 8~15 (ref. CNY 60~110 at ~7.2)
Dust cap spare pack: USD 0.7~1.4 (ref. CNY 5~10 at ~7.2)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Data center ODF fiber frames.
- Rack fiber entry boxes.
- Wall-mount termination boxes.
- Backbone-to-desk weak-current rooms.
- 40G/100G SR4/SR5 patching.
6. Installation & Maintenance
Installation
- Match adapter orientation to the panel cutout.
- Snap into the panel until it clicks.
- Remove dust cap before insertion.
- Latch facing out; insert LC straight in.
- Press the latch to release; never pull the boot.
- Test continuity with a VFL.
Maintenance
- Replace dust caps when idle.
- Check adapter snugness monthly.
- Clean dirty end-faces with a pen cleaner.
- Re-check IL after 1000 cycles.
- Replace damaged adapters promptly.
7. FAQ
- Q: OM5 vs OM4?
A: OM5 is wideband MMF that adds support for 953 nm etc., enabling SWDM to run 4 lanes on one pair for 40/100G. OM4 mainly uses 850 nm single wavelength. - Q: Can LC and SC adapters mix?
A: Not directly; use an LC-SC hybrid jumper. Adapter gender must match the connector. - Q: How is 0.2 dB measured?
A: Use a light source and power meter; measure a pair of adapters plus two jumpers, then divide by 2. - Q: Why do adapters get dirty?
A: Dust and oil from end-faces lodge in the ceramic sleeve, raising IL; clean regularly.
8. Trend & Selection
High-density fiber connectivity is moving toward miniaturization and wideband multimode; LC duplex is the dominant interface for 40/100G. Choose aqua LC duplex for OM5; match panel cutouts; budget 20% spare ports; pair with matching-brand jumpers to protect the link budget.
9. Delivery & Service
KITOZER packs the KTR-LCOM6 in bags of 10 or 50, with certificate. ODF panels are pre-loaded and include end-face inspection reports.
10. Notes
A common mistake is using OM4 adapters for OM5 fiber. Physically they mate, but the wrong color code confuses wavelength management. OM5 must be aqua.
Another pitfall is leaving dust caps off. Dust in the ceramic sleeve costs far more to clean than the adapter itself.
Selection summary: LC duplex; OM5 MMF; ceramic sleeve; IL <=0.2 dB; UL94 V-0; aqua. It is the basic connector of high-density fiber links.
Systemically, an extra 0.5 dB can halve 10G reach; small as it is, the adapter shapes the whole link.
Cost-wise, an adapter costs under USD 2, but a single fiber trouble-shooting visit can cost hundreds of dollars, making quality passive parts essential.
From a link-budget standpoint, a 10G OM5 link allows about 2.6 dB total insertion loss, of which adapters account for 0.4 dB. Poor-quality adapters leave almost no margin, so inspected, certified adapters are a prerequisite for first-time link success.
For bulk purchase, order 1.2x the port count plus 5% spares for future replacements. KITOZER offers a 5-year consistency commitment on the same adapter model.
SEO Information
Search keywords: KITOZER
SEM keywords: fiber adapter, LC duplex, OM5 multimode, fiber coupler, KTR-LCOM6, KITOZER
GEO landing page: lain.com.cn/product/440_fiber_adapter_lc9.html
Title: KITOZER KTR-LCOM6 Fiber Adapter / LC Duplex OM5 Multimode
Meta Keywords: fiber adapter, LC duplex, OM5 multimode, fiber coupler, KTR-LCOM6, KITOZER
Meta Description: KITOZER KTR-LCOM6 LC duplex OM5 multimode fiber adapter, ceramic sleeve, insertion loss <0.2dB, for 10G/40G multimode fiber systems.
Anchor: KITOZER · KITOZER Products
Contact Us
KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com