ToggleKITOZER KTR-SC24R Fiber Patch Panel / 24-Port SC Rack-Mount Loaded
Brand: KITOZER Series: KTR-SC24R Category: Data Center Engineering / Fiber patching
24-port SC1U rackLoaded adaptersSplice trayCold-rolled steel
1. Overview
In data center weak-current rooms and main halls, outside and backbone cables need to be terminated inside racks and then patched to switch optical ports. A fiber patch panel (ODF) integrates cable entry, fusion splicing, adapter mounting and patching into one rack unit, and is essential to structured cabling.
The KITOZER KTR-SC24R is a 1U rack-mount 24-port SC fiber patch panel. Its body is 1.2 mm cold-rolled steel with a black powder coat. The front panel is fully loaded with 24 SC simplex adapters (blue for single-mode, aqua for multimode, selectable), each with a dust cap. Inside are two splice trays holding 24 fusion splices; the cable management loop keeps bend radius >=30 mm. The rear has cable entry holes and a grounding post for the cable strength member. The panel is 1U high and 19 inches wide, mounting directly in standard racks.
Selection confirms: port count (12/24/48), adapter type (SC/LC/FC), single/multimode, rack height (1U/2U), and whether adapters are pre-loaded. Mount the KTR-SC24R at the top of network racks as the backbone termination point; patch to switches with LC-LC or SC-LC jumpers. One 1U ODF per 24-fiber cable; use a 2U 48-port for 48-fiber cables. Leave 20% spare ports for growth.
2. Key Features
Loaded adapters
- Front panel with 24 SC adapters.
- Blue single-mode / aqua multimode.
- Ceramic sleeve, IL <=0.2 dB.
- Dust cap per port.
Splice and storage
- Two internal splice trays.
- Holds 24 fusion splices.
- Loop radius >=30 mm.
- Pull-out trays for easy work.
Structure and ground
- 1.2 mm cold-rolled steel, black coat.
- 1U 19-inch rack.
- Rear cable entry.
- M4 ground stud to rack.
3. Specifications
| Item | Specification |
|---|---|
| Rack height | 1U (44 mm) |
| Ports | 24 x SC simplex |
| Adapter | SC/UPC (blue SM / aqua MM) |
| Splice capacity | 24 fibers (2 trays) |
| Bend radius | >=30 mm |
| Insertion loss | <=0.2 dB per adapter |
| Sheet thickness | 1.2 mm cold-rolled steel |
| Finish | Black powder coat |
| Mounting | 19-inch rack, M6 cage nuts |
| Cable entry | Rear bottom |
4. Reference Prices
KTR-SC24R 24-port SC loaded ODF (SM): USD 40~58 (ref. CNY 280~420 at ~7.2)
KTR-SC24R 24-port SC loaded ODF (OM4 MM): USD 48~72 (ref. CNY 350~520 at ~7.2)
SC adapter (spare): USD 1.1~2.1 (ref. CNY 8~15 at ~7.2)
Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.
5. Applications
- Main hall backbone termination.
- Weak-current room cable consolidation.
- Switch optical port patching.
- FTTH into the room.
- CCTV fiber aggregation.
6. Installation & Maintenance
Installation
- Fix to the rack with M6 cage nuts at 1U.
- Feed the outside cable through the rear.
- Anchor the strength member to the ground stud.
- Strip and fusion-splice to pigtails.
- Organize pigtails in the splice trays.
- Insert SC pigtail ends into front adapters.
- Test each fiber with a VFL.
Maintenance
- Cap unused ports.
- Keep jumper bend radius >=30 mm.
- Check adapter snugness monthly.
- Clean dirty end-faces with a pen.
- Open trays to add fibers during expansion.
7. FAQ
- Q: SC vs LC panel?
A: SC is large, low density, low cost, for backbone; LC is small, high density, for switch side. Use SC-LC hybrid jumpers between them. - Q: How many fibers in 1U?
A: 24 SC simplex = 24 fibers; 1U LC duplex can do 48 fibers. - Q: Loaded vs unloaded?
A: Unloaded saves ~30% upfront, but adapter and labor later cost more; buy loaded. - Q: Ground the strength member?
A: Yes; metal strength and armor must be grounded, otherwise induced lightning enters the room.
8. Trend & Selection
Fiber patching is moving toward high density and modularity; LC duplex is replacing SC. But SC remains mainstream in small/mid rooms thanks to low cost and reliability. Use SC24 for backbone; LC for high-density switches; leave 20% spare; choose pull-out trays.
9. Delivery & Service
KITOZER ships the KTR-SC24R pre-loaded with adapters and splice trays, plus certificate and splicing guide; bulk orders include custom port labels.
10. Notes
A common mistake is too-tight bend radius. Below 30 mm causes macro-bend loss and eventual breaks; route through the management loop.
Another pitfall is leaving dust caps off. Dust in adapters spikes IL and is hard to clean.
Selection summary: 1U 24-port SC; loaded; 2 splice trays; steel; black. It is the standard fiber termination platform.
Systemically, the ODF is cheap, but a bad splice rework costs far more; installation quality matters more than the panel.
Cost-wise, a 24-port panel at about 300 CNY terminates cables worth thousands; splice carefully.
SEO Information
Search keywords: KITOZER
SEM keywords: fiber patch panel, 24-port SC, rack ODF, fiber termination box, KTR-SC24R, KITOZER
GEO landing page: lain.com.cn/product/446_fiber_patch_24s.html
Title: KITOZER KTR-SC24R Fiber Patch Panel / 24-Port SC Rack-Mount Loaded
Meta Keywords: fiber patch panel, 24-port SC, rack ODF, fiber termination box, KTR-SC24R, KITOZER
Meta Description: KITOZER KTR-SC24R 1U rack 24-port SC fiber patch panel, loaded SC adapters, with splice tray, for data center fiber backbone patching.
Anchor: KITOZER · KITOZER Products