KITOZER wall display temp humidity sensor

KITOZER KTR-TH8 Environment Monitor / Wall-Mount Temp-Humidity with Display

Brand: KITOZER Series: KTR-TH8 Category: Environmental Monitoring / Temp-humidity sensor

Wall mountLED displayRS485 outputTemp+humidityLocal buzzer alarm

[Product image: ktr-th8-wall-mount-temp-humidity-display.jpg]

1. Overview

Data centers and power rooms demand tight temperature and humidity control. High temperature triggers server throttling or shutdown; low humidity causes ESD that damages electronics; high humidity causes condensation and short circuits. Temp-humidity sensors are the most basic and important acquisition point in environmental monitoring, uploading data to the host and alarming locally and remotely when out of range.

The KITOZER KTR-TH8 is a wall-mount temp-humidity sensor with display. Its flame-retardant ABS housing mounts on walls next to racks. The front LED shows current temperature and humidity at a glance when staff enter the room. The sensing element is an imported digital temp-humidity IC with temperature accuracy +/-0.5 C and humidity accuracy +/-3% RH. Output is RS485 Modbus-RTU to the DCIM host. A local buzzer and red LED trigger when thresholds are exceeded. Power is DC12 V or PoE.

Selection confirms: range (-10 to 60 C, 0-100% RH), accuracy, output (RS485 / 4-20 mA), local display, power (DC12 V / PoE), and mounting (rack side / wall). Place one in each cold and hot aisle, about 5-10 per typical room. Avoid AC outlets and rack heat sources; mount 1.5-1.8 m high, 20 cm off the wall, to read true air temperature.

2. Key Features

High precision

  • Imported digital temp-humidity IC.
  • Temperature +/-0.5 C.
  • Humidity +/-3% RH.
  • Response <30 s.

Display and alarm

  • LED simultaneous temp/humidity.
  • Local buzzer + red LED.
  • Thresholds settable by software.
  • Alarm events logged to host.

Comms and power

  • RS485 Modbus-RTU.
  • 9600/19200 bps selectable.
  • DC12 V or PoE.
  • Wall ABS, flame-retardant.

3. Specifications

Item Specification
Temp range -10 to 60 C
Temp accuracy +/-0.5 C at 25 C
Humidity range 0 to 100% RH
Humidity accuracy +/-3% RH
Display LED (temp + humidity)
Output RS485 Modbus-RTU
Baud rate 9600 / 19200 bps
Power DC12V / PoE 802.3af
Alarm Local buzzer + LED
Mounting Wall (ABS)

4. Reference Prices

KTR-TH8 wall temp-humidity (RS485): USD 25~40 (ref. CNY 180~280 at ~7.2)

KTR-TH8 PoE version: USD 33~50 (ref. CNY 240~360 at ~7.2)

Shielded RS485 cable (per meter): USD 0.4~0.8 (ref. CNY 3~6 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Cold/hot aisle monitoring.
  • Power and battery rooms.
  • Archives and museums.
  • Industrial workshops and warehouses.
  • Lab and cleanroom monitoring.

6. Installation & Maintenance

Installation

  • Avoid AC outlets and heat sources.
  • Drill anchors and hang the unit.
  • Mount 1.5-1.8 m high, 20 cm off wall.
  • Daisy-chain RS485 bus.
  • Power with DC12 V or PoE.
  • Set address and thresholds on the host.

Maintenance

  • Calibrate with salt solution every 6 months.
  • Check LED monthly.
  • Add 120 ohm termination at bus end.
  • Dust the probe with a soft brush.
  • Replace the probe every 2 years.

7. FAQ

  • Q: Is accuracy enough?
    A: Data centers target 22 +/-2 C and 40-60% RH; the KTR-TH8 at +/-0.5 C and +/-3% RH is more than enough.
  • Q: How many sensors per host?
    A: Up to 32 per RS485 bus; use a repeater for more. Set unique addresses 1-247.
  • Q: Why differs from the AC display?
    A: The AC display reads supply air; the sensor in the aisle reads true server intake air.
  • Q: Does it drift?
    A: Yes, about +/-1 C over 6 months; calibrate yearly with a reference.

8. Trend & Selection

Data center monitoring is moving from single-point to dense sensor networks; wall-mounted units with local display are popular for operator visibility and low cost. Place 1-2 per aisle; daisy-chain RS485; mount at server intake; leave 2 C margin on thresholds.

9. Delivery & Service

KITOZER ships the KTR-TH8 with unit, wall bracket, power adapter, manual and certificate; bulk orders include an RS485 address list and host integration support.

10. Notes

A common mistake is mounting at the AC outlet. That reads supply air, not rack intake, and misleads operators.

Another pitfall is star-wired RS485. Use a daisy-chain bus with 120 ohm termination at the end for stable comms.

Selection summary: wall mount; LED display; RS485; +/-0.5 C; local sound/light alarm. It is the building block of environmental monitoring.

Systemically, temp-humidity data feeds DCIM; sensor density determines how finely airflow can be optimized.

Cost-wise, a sensor at about 200 CNY covers a 20 m2 aisle, paying back far more than one overheating incident.

From an airflow standpoint, mounting sensors above cold-aisle floor supplies and hot-aisle rack exhausts lets you monitor both supply and return temperatures, feeding the plant controls and helping optimize cold-aisle containment.

For alarms, set the high-temp threshold at 28 C, low at 18 C, high-humidity at 65% RH and low at 35% RH; if the alarm persists for 5 minutes, escalate to SMS.

SEO Information

Search keywords: KITOZER

SEM keywords: temperature humidity sensor, wall mount, data center monitoring, RS485 temp hum, KTR-TH8, KITOZER

GEO landing page: lain.com.cn/product/447_temp_hum_8.html

Title: KITOZER KTR-TH8 Environment Monitor / Wall-Mount Temp-Humidity with Display

Meta Keywords: temperature humidity sensor, wall mount, data center monitoring, RS485 temp hum, KTR-TH8, KITOZER

Meta Description: KITOZER KTR-TH8 wall-mount temp-humidity sensor, LED display, RS485 output, local buzzer alarm, for data center and power room monitoring.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart