KITOZER cable tray rack base

KITOZER KTR-FL7 Rack Plinth with Cable Tray

Brand: KITOZER Series: KTR-FL7 Category: Data Center Engineering / Rack plinth

Folded steelHeight adjustableDual cable tray1000 kg loadCold aisle

[Product image: ktr-fl7-rack-plinth-cable-tray.jpg]

1. Overview

The rack plinth (also called base frame or plinth channel) is the first accessory on the floor before a row of cabinets is landed. It lifts the rack above the raised floor, solves the problem of weak floor-tile load capacity, frees the underfloor cable space, and closes the bottom of the cold aisle. In a modular cold-aisle system, the plinth combines rack support, bottom cable routing, and hot/cold-aisle segregation; it is the lower boundary of the roof-panel, side-panel, base-plinth enclosure.

The KITOZER KTR-FL7 is a rack plinth with integrated cable tray. The frame is welded from 2.0 mm cold-rolled steel and powder-coated RAL7035. Standard height is 150 mm; adjustable feet allow 100 to 300 mm tuning to match raised-floor elevations. Inside the frame are two tray tiers: upper for power cables, lower for network and fiber, separated by a metal divider to avoid EMI. Side panels are removable. M8 bolt holes on the side face let adjacent plinths bolt into a row. Load rating is >=1000 kg per cabinet, and the bolted row resists tipping.

Selection confirms cabinet depth (600/800/900/1100 mm), width (600 mm standard), raised-floor finish height (typically 300/350 mm), and whether cables run below or above. The dual-tray plinth is recommended for underfloor routing or mixed power/data at the bottom; if all cables run overhead, a simplified open plinth is enough. Buy plinths, cabinets, roof panels and side panels together so hole patterns match.

2. Key Features

Steel frame

  • 2.0 mm cold-rolled, welded frame.
  • Powder-coated RAL7035.
  • Load rating >=1000 kg per cabinet.
  • M8 side bolts tie the row together.

Dual cable tray

  • Upper power tray, lower data tray.
  • Metal divider isolates power from data.
  • Removable side panels for cable entry.
  • 100 mm tray width, fits 24 power cables.

Height and sealing

  • 150 mm standard height.
  • Adjustable feet, 100 to 300 mm.
  • Brush strips around the perimeter reduce bypass leakage.
  • Firestop mortar fills gaps to the floor.

3. Specifications

Item Specification
Cabinet W x D 600×600 / 600×800 / 600×900 / 600×1100 mm
Height 150 mm std.; adjustable 100 to 300 mm
Steel gauge 2.0 mm cold-rolled
Finish Powder coat RAL7035
Load rating >=1000 kg per cabinet
Cable tray Dual tier (power upper / data lower)
Tray width 100 mm
Row joining M8 bolts through side
Bottom sealing Brush strip + firestop mortar
Leveling feet 4 pcs M12, 50 mm travel

4. Reference Prices

KTR-FL7 plinth (600×800): USD 39~58 (ref. CNY 280~420 at ~7.2)

KTR-FL7 plinth (600×1100): USD 50~72 (ref. CNY 360~520 at ~7.2)

Brush + firestop kit: USD 5.5~11 (ref. CNY 40~80 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Row-base support in modular cold aisles.
  • Elevating cabinets in underfloor cable rooms.
  • Cabinets on weak raised-floor tiles.
  • Bottom air-sealing in aisle containment.
  • Bases for battery and UPS cabinets.

6. Installation & Maintenance

Installation

  • Mark the row layout on the floor.
  • Place plinths side by side and bolt them together.
  • Level with adjustable feet.
  • Route power and data into separate tiers.
  • Clip on removable side panels.
  • Set cabinet on plinth and bolt down.
  • Seal perimeter gaps with brush strips and firestop.

Maintenance

  • Check row bolts monthly.
  • Clean loose cable labels quarterly.
  • Inspect brush strips and firestop yearly.
  • Open side panels for new cable pulls.
  • Do not over-extend the 50 mm foot travel.

7. FAQ

  • Q: Do I need a plinth if floor tiles are strong?
    A: Yes. The plinth also routes underfloor cables and seals the cold aisle bottom. Sitting directly on tiles blocks cable access and leaks air at the bottom, raising PUE.
  • Q: What height should I pick?
    A: 150 mm suits most underfloor runs. For a 350 mm raised floor with heavy bottom cabling, choose 200 to 250 mm or use adjustable feet.
  • Q: Can power and data share one tray?
    A: Not recommended. KTR-FL7 has a two-tier tray with a metal divider; sharing drives up EMI and data errors.
  • Q: Will it hold a UPS battery cabinet?
    A: Yes under 1000 kg. Heavier 2 V battery banks need 3.0 mm steel or two plinths in parallel.

8. Trend & Selection

Modular cold aisles and micro-module rooms are the mainstream for new data centers, and the plinth has evolved from a pure support into an integrated cable, sealing, and row-tie platform. Match cabinet depth; choose dual-tray for underfloor runs; bolt the row together; never skip brush strips and firestop; derive height from the raised-floor finish.

9. Delivery & Service

KITOZER ships KTR-FL7 as knocked-down panels, field-assembled with bolts, including frame, feet, M8 row bolts, brush strips, certificate and manual, plus row layout guidance.

10. Notes

A common mistake is treating the plinth as a generic steel channel and buying it from any sheet-metal shop. Non-standard hole patterns misalign cabinets and side panels, and cold-aisle leakage points cannot be sealed.

Another pitfall is skipping brush strips and firestop. In a contained aisle, plinth gaps are one of the biggest bypass paths; unsealed gaps short-circuit cold air and raise rack inlet temp by 2 to 3 C.

Selection summary: 2.0 mm steel; 150 mm adjustable height; dual power/data trays; 1000 kg load; M8 row tie; brush + firestop seal. It is the lower boundary of a modular cold aisle.

Systemically, each 10% extra bottom leakage raises PUE by about 0.02 to 0.03, worth tens of thousands in extra power per year in a 500 kW room.

Cost-wise, a plinth around 350 CNY is under 2% of the row cost, but the leakage it prevents is worth far more. The qualified plinth is the best-value energy-savings item.

SEO Information

Search keywords: KITOZER

SEM keywords: rack plinth, cable tray base, rack floor stand, cold aisle containment, KTR-FL7, KITOZER

GEO landing page: lain.com.cn/product/450_rack_floor_6.html

Title: KITOZER KTR-FL7 Rack Plinth with Cable Tray

Meta Keywords: rack plinth, cable tray base, rack floor stand, cold aisle containment, KTR-FL7, KITOZER

Meta Description: KITOZER KTR-FL7 rack plinth with dual cable tray, folded steel frame, adjustable height 100-300mm, for modular cold aisle containment.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart