KITOZER
KITOZER

KITOZER 8 zone leak controller

KITOZER KTR-WC5 8-zone Locating Water Leak Controller

Brand: KITOZER Series: KTR-WC5 Category: Environmental Monitoring / Leak detection

8-zone locatingSensing cable1 m precisionRS485Dry contacts

[Product image: ktr-wc5-8-zone-locating-water-leak-controller.jpg]

1. Overview

Water leaks are the second most common data-center outage after power. A broken AC drain pipe, sweating chilled-water insulation, leaking fire-protection piping or failed bathroom waterproofing can flood under-floor cabling and equipment within minutes. Standing water under raised floor tiles is invisible, and by the time servers alarm, a short circuit may already have happened. A leak detection system runs sensing cable around AC units and water pipes; the moment water touches the cable, the controller alarms and shows the exact location so staff can act fast.

The KITOZER KTR-WC5 is an 8-zone locating water leak controller. The wall-mounted metal chassis carries an LCD screen and buttons showing the status of 8 zones and the exact distance of the leak. It accepts up to 8 sensing cables, each up to 100 m long, with locating accuracy of +/-1 m. The four-conductor cable uses two sense wires and two reference wires to compensate for humidity drift, ideal under precision AC units and around condensate pans. Outputs include an 85 dB buzzer, two dry contacts (leak / fault), and RS485 Modbus-RTU to the DCIM. Power is DC12 V, 5 W. The cable is orange PVC, 6 mm OD, routed under the floor with sealed end caps at both ends.

Selection confirms zone count (8), total cable length (estimate around each AC), whether locating is needed, and the upload path (RS485 / dry contact). A small room fits on 8 zones; large modular rooms cascade multiple units on one RS485 bus. Run a loop around each precision AC base (5 to 8 m), and route the cable along chilled-water lines.

2. Key Features

8-zone locating

  • 8 cable inputs, up to 100 m each.
  • Location accuracy +/-1 m.
  • LCD shows zone and distance.
  • Continuity monitoring on every loop.

Sensing cable

  • Four-conductor design with reference compensation.
  • Orange PVC jacket, 6 mm OD.
  • Corrosion resistant, reusable.
  • Sealed end caps and clips included.

Alarm and upload

  • 85 dB buzzer.
  • Two dry contacts (leak / fault).
  • RS485 Modbus-RTU.
  • DC12 V, 5 W.

3. Specifications

Item Specification
Zones 8
Cable length per zone up to 100 m
Location accuracy +/-1 m
Cable 4-conductor, 6 mm, orange PVC
Display LCD + buttons
Alarm output 2 dry contacts (leak / fault)
Comm RS485 Modbus-RTU
Power DC12V / 1A
Power consumption <=5 W
Mounting Wall-mount metal chassis

4. Reference Prices

KTR-WC5 8-zone locating controller: USD 122~178 (ref. CNY 880~1280 at ~7.2)

Locating sensing cable: USD 1.7~2.8 per meter (ref. CNY 12~20 at ~7.2)

Sealed end-cap + clip kit per zone: USD 8.5~14 (ref. CNY 60~100 at ~7.2)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Condensate pan leak detection under precision AC.
  • Chilled-water and cooling-water piping routes.
  • Under-floor cable pathways.
  • Battery room and battery cabinet sumps.
  • Rooms next to pantries and bathrooms.

6. Installation & Maintenance

Installation

  • Wall-mount the controller at 1.5 m near the room entrance.
  • Route cable around each AC base with 3 cm slack.
  • Clip the cable every 0.5 m under the floor.
  • Wire both sealed ends to the controller terminals.
  • Daisy-chain RS485 to the DCIM.
  • Wire dry contacts to the room siren.
  • Test with a damp cloth to verify location readout.

Maintenance

  • Test monthly with a damp cloth.
  • Inspect cable quarterly for rodent or foot damage.
  • Wipe cable surfaces with alcohol every six months.
  • Calibrate locating accuracy yearly.
  • Replace cable if the jacket is cracked.

7. FAQ

  • Q: Does the cable sense oil?
    A: No. Resistive cables sense water-based liquids (conductivity >50 uS/cm); oil and glycol do not trigger. Use a separate oil cable for oil spills.
  • Q: What if 8 zones are not enough?
    A: Daisy-chain multiple KTR-WC5 units on RS485, each with a different Modbus address. Up to 32 units share one DCIM.
  • Q: Are there many false alarms?
    A: Rare in dry rooms. High humidity (>90%) or condensation on the cable can trigger; do not route the cable directly under AC outlets.
  • Q: Can a cut cable be spliced?
    A: Not on site. Replace the whole section; field joints add resistance and distort the location reading.

8. Trend & Selection

Leak detection has moved from simple switching alarms to multi-zone locating systems, with accuracy improving from 5 m to 1 m. As modular cold aisles seal under-floor space, late leak discovery is more expensive, and locating detection is becoming standard in new rooms. Estimate cable length by AC count with 20% spare; 1 m accuracy suffices for fast response; wire RS485 to DCIM; test quarterly; keep cable away from strong EMI.

9. Delivery & Service

KITOZER ships KTR-WC5 with controller, DC12 V adapter, mounting bracket, terminals, certificate and manual. Sensing cable is cut to order. We provide Modbus integration and on-site testing guidance.

10. Notes

A common mistake is running cable only under AC units and ignoring water pipes. Internal condensate pans rarely leak compared with external pipe joints; the piping routes are where leaks actually happen.

Another pitfall is laying the cable flat on the floor. Under-floor condensation keeps the cable perpetually damp. Lift it 3 to 5 cm so it only touches water when pooling reaches a meaningful depth.

Selection summary: 8-zone locating; 100 m per zone; 1 m accuracy; 4-conductor sensing cable; RS485 + dry contacts; buzzer. It is the best-value early-warning device in room environmental monitoring.

Systemically, an average leak event costs tens of thousands in cable replacement and downtime, while a full detection system is around 3000 CNY; the payback is obvious.

Cost-wise, an 8-zone controller plus 20 m of cable around 1200 CNY covers a whole floor and is nearly mandatory insurance.

SEO Information

Search keywords: KITOZER

SEM keywords: water leak controller, 8-zone locating, leak detection cable, data center monitoring, KTR-WC5, KITOZER

GEO landing page: lain.com.cn/product/455_leak_ctrl3.html

Title: KITOZER KTR-WC5 8-zone Locating Water Leak Controller

Meta Keywords: water leak controller, 8-zone locating, leak detection cable, data center monitoring, KTR-WC5, KITOZER

Meta Description: KITOZER KTR-WC5 8-zone locating water leak controller with sensing cable, RS485 Modbus and dry contacts, for precision AC leak detection.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com