KITOZER KTR-FL8 Rack Plinth / Fan-Assisted Base

Brand: KITOZER Series: KTR-FL8 Category: Data Center Engineering / Rack Plinth

Fan-assisted plinthBottom air supplyAdjustable heightHigh load ratingCold-rolled steel

[Product image: ktr-fl8-rack-plinth-with-fans.jpg]

1. Overview

When a rack sits directly on the floor there is no inlet plinth. With hot/cold-aisle containment, rack intake relies on the raised-floor plenum. But if floor height is low, under-floor cabling blocks airflow, or rack density is high, bottom intake falls short and inlet temperature rises. A fan-assisted plinth under the rack actively draws cold air up from below, supplementing intake for dense racks.

The KITOZER KTR-FL8 is a fan-assisted rack plinth. It is welded and folded from cold-rolled steel with a powder-coated finish, rated for >=800 kg, fitting 42U/47U racks and their equipment. Height is adjustable, typically 100-200 mm, with leveling feet. Two to four DC axial fans are built in, drawing air from below and blowing it up into the rack bottom inlet, with speed tied to rack inlet temperature. Cable slots and baffles manage both cabling and airflow.

Selection confirms rack size and weight, raised-floor height, required supplemental airflow, fan power (DC48V or AC220V), and whether temperature-linked control is needed. Low-density racks use a plain plinth; fan-assisted supply suits dense racks (>=5 kW per rack). The fans supplement supply, they do not replace room AC; airflow must match cooling capacity to avoid short-circuiting.

2. Key Features

High load structure

  • Welded folded cold-rolled steel.
  • Load >=800 kg.
  • Powder-coated finish.
  • Fits 42U/47U racks.

Fan-assisted supply

  • 2-4 built-in DC axial fans.
  • Draws from below, blows up.
  • Speed linked to temperature.
  • Supplements dense-rack intake.

Adjustment and cabling

  • Height adjustable 100-200 mm.
  • Leveling feet.
  • Cable slots and baffles.
  • Pairs with aisle containment.

3. Specifications

Item Specification
Type Fan-assisted rack plinth
Load rating >= 800 kg
Material Cold-rolled steel, powder-coated
Rack fit 42U / 47U standard
Plinth height 100-200 mm adjustable
Fans 2-4 DC axial fans
Fan power DC 48V / AC 220V optional
Control Temperature-linked speed
Feet Adjustable leveling feet
Finish Electrostatic powder coat

4. Reference Prices

KTR-FL8 fan-assisted plinth: USD 125~250 (ref. CNY 900~1800)

Plain load plinth (no fans): USD 40~85 (ref. CNY 300~600)

DC fan spare: USD 11~21 (ref. CNY 80~150)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Supplemental bottom supply for dense racks.
  • Contained hot/cold aisle rows.
  • Low raised-floor height scenarios.
  • >=5 kW per rack deployments.
  • Modular data-center rack bases.

6. Installation & Maintenance

Installation

  • Position to the rack footprint.
  • Level with adjustable feet.
  • Set the rack and bolt it down.
  • Wire fans to the correct voltage.
  • Link fan control to the DCIM.
  • Align with the under-floor plenum.
  • Seal baffles to stop leakage.

Maintenance

  • Clean fan intake filters quarterly.
  • Check fan noise and speed.
  • Tighten feet and rack bolts.
  • Measure rack inlet temperature.
  • Replace noisy or stopped fans.

7. FAQ

  • Q: Can the plinth replace AC?
    A: No. It moves existing cold air into the rack; cooling still comes from room AC. Match airflow to cooling capacity.
  • Q: Do all racks need it?
    A: No. Low-density racks get enough natural intake; add fans only where inlet temperature runs high.
  • Q: Is the load rating enough?
    A: >=800 kg suits a typical 42U rack with gear; over-weight battery cabinets need separate calculation.
  • Q: What if a fan fails?
    A: Fans are plug-in modules; swap a spare with power off, without taking the rack down.

8. Trend & Selection

Per-rack density keeps rising from 3-5 kW to 8-15 kW, making bottom supply, rear-door heat exchangers and liquid cooling complementary. Fan plinths trend toward DC48V, DCIM-linked speed control and modular fan units. Add fans by rack density and match airflow to cooling.

9. Delivery & Service

KITOZER ships KTR-FL8 knocked down with the frame, fan modules, leveling feet, bolts, certificate and manual. Fan power is supplied to order, along with containment interface drawings.

10. Notes

A common mistake is fitting fan plinths to every rack. Low-density racks already have enough intake; extra fans add noise and power. Deploy on demand.

Another pitfall is leaving gaps around the plinth. Cold air short-circuits through the gaps instead of entering the rack; fit baffles and seals.

In short: fan-assisted, >=800 kg, adjustable height, DC temperature-linked fans, pairs with containment. It supplements dense-rack bottom supply.

System-wise, the plinth fans are part of airflow design alongside raised floor, AC and containment.

Cost-wise, a plinth costs about a thousand CNY, while throttling from poor intake costs far more.

SEO Information

Search keywords: KITOZER

SEM keywords: rack plinth, rack base with fans, rack bottom air supply, rack plinth load rating, cold aisle rack base, KTR-FL8, KITOZER

GEO landing page: lain.com.cn/product/466_rack_floor_7.html

Title: KITOZER KTR-FL8 Rack Plinth / Fan-Assisted Base

Meta Keywords: rack plinth, rack base with fans, rack bottom air supply, rack plinth load rating, cold aisle rack base, KTR-FL8, KITOZER

Meta Description: KITOZER KTR-FL8 fan-assisted rack plinth, cold-rolled steel, load >=800 kg, adjustable height, bottom fans push air upward into the rack.