KITOZER 12V 24Ah gel deep cycle

KITOZER KTR-BAT24F Battery / 12V24Ah Gel Deep-Cycle

Brand: KITOZER Series: KTR-BAT24F Category: Power Distribution / Backup Battery

12V24AhGel deep-cycleMaintenance-freeUPS backupLong life

[Product image: ktr-bat24f-12v24ah-gel-deep-cycle-battery.jpg]

1. Overview

UPS and DC panels rely on battery strings to carry the load during mains loss; the string is the heart of backup power. Rooms commonly use 12V VRLA batteries in series to reach the DC bus (e.g. 32 x 12V for a 384V system). Gel batteries suspend electrolyte in a gel, so it does not stratify or leak and they can be mounted in any orientation; deep-cycle performance outlasts ordinary AGM when discharges are deeper and cycles more frequent.

The KITOZER KTR-BAT24F is a 12V24Ah VRLA gel deep-cycle battery. Nominal 12V, 24Ah (20-hour rate), with gel electrolyte and pasted plates. The sealed valve-regulated design emits no acid mist and needs no water under normal use. Self-discharge is about 3% per month at 25C. Design float life is 10-12 years at 25C; about 600 deep cycles at 100% DOD. Carrying handle and valve-regulated terminals suit rack stacking in series strings.

Selection: system voltage sets series count; backup runtime sets total Ah (N x single-cell capacity); correct for discharge rate and temperature. 24Ah suits small UPS, DC panels and monitoring backup; large rooms use bigger cells or parallel strings. Limit parallel groups to four, and never mix old and new cells. Keep 20-25C; every 10C above halves life. Float at 13.5-13.8V/cell, equalize at 14.4-15.0V/cell.

A battery string is a chain: its runtime is limited by the weakest cell, not the average. That is why periodic conductance or internal-resistance readings matter – they reveal the laggard before the whole string fails a load test. Cells should be replaced as a matched set, not individually, because mixing a new 12V cell into an aged string causes mismatched charge acceptance and circulating currents. Temperature is the other silent killer: every 10 C above 25 C roughly halves service life, so a 30 C battery room already trades years off a 10-year design life. Charge voltage must be temperature-compensated; floating too high dries out the gel, floating too low causes sulfation. When decommissioning exhausted cells, follow local lead-acid recycling rules rather than discarding them with general waste.

2. Key Features

Gel deep-cycle

  • Gel electrolyte, no stratify or leak.
  • About 600 cycles at 100% DOD.
  • Tolerates deep discharge better than AGM.
  • Mount in any orientation.

Sealed maintenance-free

  • Valve-regulated, no topping up.
  • No acid mist in normal use.
  • ~3% per month self-discharge at 25C.
  • 10-12 year float design life.

Form and accessories

  • Standard 12V24Ah footprint.
  • Handle and valve terminals.
  • Rack stacking in series/parallel.
  • Flame-retardant ABS case.

String health

  • Track internal resistance per cell.
  • Replace cells as a matched set.
  • Compensate charge voltage for temp.
  • Recycle exhausted cells properly.

3. Specifications

Item Specification
Nominal voltage 12 V
Nominal capacity 24 Ah (20h, 1.75V/cell cutoff)
Type VRLA gel lead-acid
Float voltage 13.5 ~ 13.8 V/cell (25C)
Equalize voltage 14.4 ~ 15.0 V/cell
Deep-cycle life about 600 cycles at 100% DOD
Self-discharge about 3%/month at 25C
Operating temp -15 to +50 C (recommended 25C)
Terminals M5/M6 valve-regulated
Case Flame-retardant ABS

4. Reference Prices

KTR-BAT24F 12V24Ah gel battery: USD 39~78 (ref. CNY 280~560)

Inter-cell connector (per string): USD 2~4 (ref. CNY 15~30)

Battery capacity test service: USD 42~83 (ref. CNY 300~600)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Small UPS backup strings.
  • DC panels and switchgear power.
  • Monitoring and access backup.
  • PV / solar auxiliary storage.
  • Emergency lighting and fire backup.

6. Installation & Maintenance

Installation

  • Series to the required bus voltage.
  • Never mix old/new or brands.
  • Tighten connectors diagonally.
  • Rack-stack with ventilation.
  • Hold 20-25 C ambient.
  • Series first, parallel <=4 groups.
  • Do commissioning capacity test.

Maintenance

  • Measure float voltage quarterly.
  • Run capacity discharge yearly.
  • Check connectors for heat/oxidation.
  • Keep the room ventilated and cool.
  • Log internal-resistance trends.

7. FAQ

  • Q: Gel or AGM?
    A: Gel tolerates deep cycles and heat; AGM handles high current better. For float UPS both work; choose gel for frequent deep discharge.
  • Q: How long do they last?
    A: 10-12 years at 25C float; heat and deep discharge shorten real life.
  • Q: How many parallel strings?
    A: Usually <=4 of identical batch; more causes circulating current and imbalance.
  • Q: Can I use a swollen battery?
    A: No. Swelling means gas generation or dry-out; replace the whole string to avoid leakage and thermal runaway.

8. Trend & Selection

Backup batteries evolve from plain VRLA toward gel and Li-ion, but 12V lead-acid stays mainstream due to maturity and cost. String monitoring (internal-resistance trending) becomes standard to predict weak cells. Size runtime properly, use same batch, and treat temperature control as the key life-extender.

9. Delivery & Service

KITOZER ships KTR-BAT24F with the cell, connectors, certificate and manual. Strings include connectors and rack layout, with runtime and capacity sizing calculations.

10. Notes

A common mistake is reading Ah without temperature correction; heat cuts both real capacity and life, so room cooling matters.

Another pitfall is mixing old cells in series: the weak cell drags the whole string, dies first under discharge, and gets reverse-charged.

In short: 12V24Ah, gel deep-cycle, 10-12 year float, maintenance-free, series-stringed. The heart of UPS backup.

System-wise, one weak cell cuts the whole string’s runtime; periodic capacity tests are not skippable.

Cost-wise, a cell costs a few hundred CNY; an outage caused by failed batteries costs far more.

Operationally, runtime equals the weakest cell’s capacity, so trending internal resistance finds the laggard years before an outage exposes it.

SEO Information

Search keywords: KITOZER

SEM keywords: 12V24Ah battery, gel battery, deep cycle battery, UPS backup battery, VRLA battery, KTR-BAT24F, KITOZER

GEO landing page: lain.com.cn/product/477_battery_12v24f.html

Title: KITOZER KTR-BAT24F Battery / 12V24Ah Gel Deep-Cycle

Meta Keywords: 12V24Ah battery, gel battery, deep cycle battery, UPS backup battery, VRLA battery, KTR-BAT24F, KITOZER

Meta Description: KITOZER KTR-BAT24F 12V24Ah VRLA gel deep-cycle battery, sealed maintenance-free, 10-12 year float design life, for UPS and DC bus backup.

Anchor: KITOZER · KITOZER Products

Contact Us

KITOZER Brand
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP:+86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart