KITOZER
KITOZER

KITOZER vertical sight glass oil separator

KITOZER KTR-OS17 Vertical Oil Separator with Sight Glass for Precision AC

Brand: KITOZER Series: KTR-OS17 Category: Data Center Engineering 2 / Refrigeration Auxiliary

oil separatorvertical typesight glasscompressor oil returnprecision AC

[Product image: ktr-os17-vertical-oil-separator-sight-glass.jpg]

1. Overview

Data center precision air conditioners use a vapor-compression refrigeration cycle, where the compressor is the core moving part. Its crankcase is filled with refrigeration oil for lubrication, sealing and cooling. During compression, high-temperature high-pressure refrigerant vapor carries entrained oil mist out of the compressor and into the condenser and evaporator. An oil film on heat exchanger tubes increases thermal resistance and reduces efficiency; excessive oil accumulation on the low-pressure side can cause poor oil return and even compressor seizure. The oil separator is installed between the compressor discharge line and the condenser. It slows the gas flow, uses centrifugal force and a filter mesh to separate entrained oil droplets, collects them in a bottom sump, and returns the oil to the compressor crankcase through a capillary tube or float valve.

KITOZER KTR-OS17 is a vertical oil separator. Inlet gas enters tangentially at the top, creating a swirling flow that flings oil droplets to the cylinder wall; droplets then slide down to the bottom sump. Clean refrigerant vapor exits from the top or side outlet. A sight glass at the bottom allows direct visual inspection of oil level in the sump, so maintenance staff can verify whether oil return is flowing and whether makeup oil is needed. Compared with horizontal separators, the vertical design saves floor space, offers higher separation efficiency, and provides a clear oil-level view — well suited to the cramped outdoor units of data center precision air conditioners.

Oil separators are classified by principle: inertia, filter, and centrifugal. KTR-OS17 uses a combined centrifugal-plus-filter design: tangential inlet creates centrifugal force to throw out most oil droplets first, then a stainless-steel wire mesh captures residual oil mist. Overall separation efficiency reaches 98% or above. The cylinder is rated for 3.0 MPa and compatible with R22, R410A and R134a refrigerants. Connections are welded or flanged; the bottom oil return port connects via capillary to the compressor crankcase. The bottom sight glass shows oil level, and some models also include a refrigerant moisture indicator that changes color when moisture content rises.

2. Key Features

Combined centrifugal + filtration

  • Tangential inlet creates centrifugal swirl; oil droplets hit wall and slide down.
  • Stainless-steel mesh filters residual oil mist.
  • Overall separation efficiency ≥98%.
  • Vertical cylinder saves space; oil level easy to observe.

Sight glass oil-level view

  • Transparent window at bottom for direct oil-level check.
  • Diagnoses whether oil return is flowing.
  • Indicates when refrigeration oil makeup is needed.
  • Select models include refrigerant moisture indicator.

Oil return mechanism

  • Bottom sump collects separated oil.
  • Returns oil via capillary tube or float valve.
  • Float-type automatic return, no shutdown needed.
  • Capillary type is simple and reliable.

Pressure rating & compatibility

  • Design pressure 3.0 MPa.
  • Compatible with R22 / R410A / R134a.
  • Welded steel cylinder with anti-corrosion coating.
  • Welded or flanged connections available.

3. Specifications

Item KTR-OS17-05 KTR-OS17-10 KTR-OS17-20
Refrigeration capacity 5~15 kW 15~45 kW 45~90 kW
Cylinder diameter Ø100 mm Ø150 mm Ø200 mm
Inlet/outlet Ø12 mm Ø16 mm Ø22 mm
Oil return port Ø6 mm capillary Ø8 mm capillary Ø10 mm float valve
Separation efficiency ≥95% ≥98% ≥98%
Design pressure 3.0 MPa 3.0 MPa 3.0 MPa
Sight glass Oil-level glass Oil-level + moisture Oil-level + moisture
Mounting Vertical welded Welded / flanged Vertical flanged
Refrigerant R22 / R410A R22 / R410A / R134a R410A / R134a

4. Reference Prices

KTR-OS17-05 small oil separator (Ø100 cylinder, capillary return, oil-level glass): Reference USD 49~90 / unit (ref. CNY 350~650 at ~7.2)

KTR-OS17-10/20 medium/large separator (Ø150~200 cylinder, float return, oil-level + moisture glass): Reference USD 111~250 / unit (ref. CNY 800~1,800 at ~7.2)

Reference only; final quote depends on capacity, connection type and refrigerant. Refrigeration oil charge and welding installation excluded. Volume discounts available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center precision AC compressor discharge lines (air-cooled / water-cooled).
  • Room dedicated constant-temperature/humidity outdoor units.
  • Industrial chillers and heat pump units oil return lines.
  • VRV/VRF multi-split main line oil separation.
  • Cold storage and process cooling oil separator replacement.

6. Installation & Maintenance

Installation

  • Install vertically; inlet to compressor discharge, outlet to condenser.
  • Cylinder must not tilt, to preserve centrifugal separation.
  • Return capillary to compressor crankcase return port; keep line short, no oil traps.
  • Bottom drain valve (if equipped) to oil collection bottle.
  • Weld with nitrogen purge to prevent oxide scale entering system.
  • Evacuate, charge refrigerant per spec; check oil level through sight glass after start.

Maintenance

  • Periodically inspect oil level via sight glass; top up same-grade oil if low.
  • Check return capillary for blockage (line should feel slightly cool).
  • If moisture glass changes color (green to yellow/pink), system contains water; dry it.
  • Annually inspect cylinder welds and joints for oil leaks.
  • During major refrigerant overhaul, clean or replace internal mesh.

7. FAQ

  • Q: No oil visible in sight glass — is that normal?
    A: Not necessarily. Too low means poor oil return or system oil shortage; too high means return capillary blocked and oil pooling in separator. Normal level is 1/2~2/3 of glass.
  • Q: What happens if inlet and outlet are reversed?
    A: Reversed inlet/outlet destroys centrifugal flow direction; separation efficiency drops sharply and oil floods the condenser. Follow cylinder arrow markings.
  • Q: Does the oil separator need periodic oil changes?
    A: The separator itself does not store oil permanently — it separates and returns it. What needs checking is the compressor crankcase oil level; sump oil is transient and should return to the compressor.
  • Q: Why does precision AC frequently trip on low pressure?
    A: Possibly blocked oil return: oil pools on the evaporator low side, compressor runs low on oil, discharge temperature rises, and low-pressure protection triggers. Check return capillary and separator sight glass.

8. Trend & Selection

Data center refrigeration is moving from fixed-speed to inverter, from CAV to VAV. Compressors now run over a wider speed range; at low speed, discharge carries proportionally more oil, demanding better low-speed separation. Modern separators trend toward: high-efficiency centrifugal-plus-mesh design, combined oil-level and moisture sight glass, float automatic return replacing capillary (to avoid blockage), and compatibility with new refrigerants like R32. Select by compressor displacement (not just cooling capacity) to keep internal gas velocity in range; vertical mounting saves outdoor-unit space; sight glass is essential for maintenance; prefer float return for large units or filtered capillary for small units; match connections to site piping; for R410A choose ≥3.0 MPa rating.

9. Delivery & Service

KITOZER provides oil separator selection: based on compressor model, displacement, refrigerant type and connection size, we match the correct vertical separator. We supply installation drawings (inlet, outlet, return, drain port positions). Bundled supply available with precision AC units and chillers. Delivery includes separator body, mounting bracket, capillary fittings and manual. Warranty includes installation guidance and oil-return commissioning support.

10. Additional Notes

The most common problem is “separator installed but return line blocked.” The separator does its job removing oil from discharge, but if the return capillary is clogged, oil pools in the separator and never reaches the compressor. The sight glass shows a high oil level, yet the compressor crankcase is starved — after a while it seizes. So during installation, blow through the return line with nitrogen before evacuation, and ensure no kinks or flattened sections.

Another pitfall: “separator mounted at an angle.” Vertical separators rely on centrifugal force; tilt destroys the swirling flow and oil droplets ride straight into the condenser. When outdoor space is tight, some installers tilt or lay the separator horizontally — separation efficiency collapses. It must be vertical, within 5 degrees.

Selection summary: size by displacement; mount vertical and upright; sight glass is mandatory; blow through return line and avoid kinks; prefer float return; choose 3.0 MPa for R410A. The oil separator is the liver of the refrigeration system — it separates oil mist and ensures return; when it works, the compressor lives long.

SEO Information

Search keywords:oil separatorvertical oil separatorsight glasscompressor oil returnrefrigeration oil separationprecision AC oil separatorKTR-OS17KITOZER

SEM keywords:oil separator price,vertical oil separator manufacturer,compressor oil return,sight glass oil separator,KTR-OS17,KITOZER

GEO landing page:lain.com.cn/product/ktr-os17-vertical-oil-separator-sight-glass.html

Title:KITOZER KTR-OS17 Vertical Oil Separator with Sight Glass for Precision AC

Meta Keywords:oil separator,vertical oil separator,sight glass,compressor oil return,refrigeration oil separation,precision AC,KTR-OS17,KITOZER

Meta Description:KITOZER KTR-OS17 vertical oil separator with sight glass for data center precision air conditioning, separates refrigerant-oil mixture and returns oil to compressor crankcase.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart