KITOZER KTR-SC12R 1U Rack 12-Port SC Single-Mode Fiber Patch Panel

Brand: KITOZER Series: KTR-SC12R Category: Weak Current System 2 / Fiber Cabling

12-port SC1U racksingle-modesplice trayODF

[Product image: ktr-sc12r-rack-12port-sc-single-mode-patch-panel.jpg]

1. Overview

An ODF (Optical Distribution Frame) is the core management device for fiber cabling in a data hall. Outdoor cable enters the hall but cannot plug directly into a switch — it is a round, stiff jacket holding bare fiber, while the switch optical module accepts a flexible cord with a connector. The ODF “terminates” bare fibers into standard ports: cable enters the rear of the ODF, each fiber is fusion-spliced to an SC/LC pigtail, the pigtail runs through the ODF, and the connector plugs into a front-panel adapter. The front panel becomes a neat “fiber outlet wall”; cords patch from panel to switch, and future changes move cords only, never touching the backbone cable.

KITOZER KTR-SC12R is a 1U rack 12-port SC single-mode patch panel. Front has 12 SC simplex adapters (blue UPC or green APC options); rear includes a splice tray (12-fiber capacity). 1U height mounts on a 19-inch rack — the most common size for small-to-medium fiber termination. A cabinet typically holds 2~4 × 12-port ODFs for 24~48-fiber backbone termination. Cold-rolled steel, powder-coated; splice tray pulls out or flips up for easy fusion; internal fiber storage loops excess pigtails with bend radius ≥30 mm; panel has label slots for port numbers.

ODFs are sized by density: 12-port (1U), 24-port (1U high-density or 2U), 48-port (2U/3U), 96-port (3U/4U). By connector: SC (square), LC (small square), FC (round). SC was the early mainstream; LC dominates new data centers due to smaller size. The ODF itself is passive; quality hinges on: adapter IL consistency, splice tray convenience, storage area and bend radius, and shield grounding. Select ports by backbone fiber count with 30% spare; connector type by switch optical module; single/multi-mode by cable type; choose whether to include a splice tray (blank panels only hold adapters, splicing done elsewhere).

2. Key Features

12-port SC 1U rack

  • 1U standard 19-inch rack mount.
  • Front 12 SC adapters.
  • Single-mode UPC (blue) or APC (green) options.
  • Cold-rolled steel, powder coat.

Integrated splice tray

  • Rear 12-fiber splice tray.
  • Hinged flip-up design for easy work.
  • Heat-shrink protection tube slots.
  • Storage loop area ≥30 mm bend radius.

Management & labels

  • Panel label slots for port numbers.
  • Front and rear patch management.
  • Dust caps for unused ports.
  • Stack multiple ODFs.

Compatibility & ground

  • Fits 19-inch standard rack.
  • SC adapters single-mode universal.
  • Chassis ground lug (to rack ground).
  • Lightweight, easy install.

3. Specifications

Item KTR-SC12R
Ports 12 SC simplex
U height 1U (44.45 mm)
Connector SC (single-mode UPC blue / APC green)
Splice capacity 12 fibers
Adapter IL ≤0.2 dB
Fiber mode Single-mode OS2 (multi-mode optional)
Chassis 1.2 mm cold-rolled steel, powder coat
Mounting 19-inch rack 1U
Ground lug M4 bolt to rack ground
Dimensions (W×D×H) 483×150×44 mm

4. Reference Prices

KTR-SC12R 12-port SC single-mode ODF (1U, incl. 12 SC adapters, splice tray): Reference USD 17~35 / unit (ref. CNY 120~250 at ~7.2)

Including 12 SC/UPC single-mode pigtails + heat-shrink sleeves: Reference USD 25~44 / unit (ref. CNY 180~320 at ~7.2)

Reference only; priced by adapter type and quantity. Patch cords not included. Volume discount above 10 units. LC/FC connectors same price on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center rack fiber backbone termination.
  • Telecom room / wiring closet ODF.
  • Enterprise core switch fiber access.
  • Security surveillance fiber transmission termination.
  • Industrial control fiber ring node.

6. Installation & Maintenance

Installation

  • Mount ODF in 1U rack position; tighten front and rear posts.
  • Cable enters from rear; strip outer jacket.
  • Fusion-splice each fiber to SC pigtail (fusion splicer).
  • Cover splice point with heat-shrink; clip into tray slot.
  • Coil excess pigtail in storage area; bend radius ≥30 mm.
  • Plug pigtail connector into front adapter.
  • Label front panel to match cable fiber number.

Maintenance

  • Periodically clean adapter end faces (fiber cleaning pen).
  • Check cords for tight bends (<30 mm).
  • Cap unused ports with dust plugs.
  • Re-apply fallen labels.
  • Connect ODF chassis ground to rack ground.

7. FAQ

  • Q: Is 12-port ODF enough?
    A: Depends on backbone fiber count. 12-fiber cable → one 12-port; 24-fiber → two 12-port or one 24-port. Leave 30% spare; plan 12-fiber entry as 18-fiber capacity.
  • Q: ODF vs fiber terminal box?
    A: Terminal box is wall-mounted, small (4~24 fibers), not rack-standard; ODF is 19-inch rack 1U/2U for centralized rack patching.
  • Q: Fusion splicing vs field termination?
    A: Fusion has lower loss (≤0.05 dB) and long-term stability — the data center standard. Field termination is fast but higher loss, for emergency repair.
  • Q: Does ODF need grounding?
    A: Chassis ground to rack ground suffices; outdoor cable metal strength-member grounding is done at the cable entrance box. ODF chassis ground is shield ground, not lightning ground.

8. Trend & Selection

As data centers densify, ODFs evolve from 12-port SC to 24-port high-density LC and MPO trunk + LC breakout. MPO/MTP trunk cable (12/24 fibers in one cable) runs between buildings to the hall, then breaks out via MPO-LC fanout cords to the ODF, saving rack space. Trends: high-density LC adapters (24 ports per 1U), modular ODF (swappable adapter cassettes), cable management arms. New builds choose LC (small, high density); retrofit SC is fine; size ports by fiber count ×1.3 spare; single-mode OS2; splice tray included (not blank); bend radius ≥30 mm; ceramic-sleeve adapters; unified labeling; ODF coordinated with cable managers.

9. Delivery & Service

KITOZER provides ODF selection: based on backbone fiber count, connector type (SC/LC) and single/multi-mode, we match the right capacity panel. Bundled with cable, pigtails, patch cords and fusion splicing service. Delivery includes ODF body, adapters, splice tray, heat-shrink sleeves and manual. Warranty covers fusion termination guidance.

10. Additional Notes

The most common install issue is “pigtail bend radius too small.” To stuff excess pigtails, installers fold them at right angles or coil them tight — bend radius under 10 mm causes macrobend loss, attenuating light inside the ODF itself. Power budget may pass at test, but aging worsens it. Pigtail bend radius must be ≥30 mm (about a fist); coil loosely in the storage tray, don’t pull tight.

Another pitfall: “labels don’t match.” Fiber #1 spliced to SC port #3 but labeled as port #1 — when a fault occurs, tracing by label leads to the wrong fiber, and repairs make it worse. Label as you splice: one fiber, one label, on the spot. Don’t backfill labels from memory.

Selection summary: 12-port 1U for small/medium; SC single-mode mainstream; splice tray included; bend radius ≥30 mm; labels match fiber numbers; cap unused ports. The ODF is the fiber outlet wall — neat termination and clear labels make future patching quick; messy termination makes every future visit a blind box.

SEO Information

Search keywords:fiber patch panel12-port SCrack ODFsingle-mode panel1U fiber boxSC terminationKTR-SC12RKITOZER

SEM keywords:12-port SC patch panel price,rack ODF supplier,single-mode fiber panel,1U fiber box,KTR-SC12R,KITOZER

GEO landing page:lain.com.cn/product/ktr-sc12r-rack-12port-sc-single-mode-patch-panel.html

Title:KITOZER KTR-SC12R 1U Rack 12-Port SC Single-Mode Fiber Patch Panel

Meta Keywords:fiber patch panel,12-port SC,rack ODF,single-mode,1U fiber box,SC termination,KTR-SC12R,KITOZER

Meta Description:KITOZER KTR-SC12R 1U rack 12-port SC single-mode fiber patch panel with splice tray and adapters, for rack fiber backbone termination and patch management.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart