KITOZER Ethernet TH sensor

KITOZER KTR-TH10 Ethernet Temperature & Humidity Sensor

Brand: KITOZER Series: KTR-TH10 Category: Environmental Monitoring 2 / Temperature & Humidity

EthernetPoEModbus TCP±0.3℃DCIM integration

[Product image: ktr-th10-ethernet-temperature-humidity-sensor.jpg]

1. Overview

Temperature and humidity are the core of data hall environmental monitoring. Too hot and servers throttle down or overheat-shutdown; too dry and static discharge damages chips; too humid and condensation shorts circuit boards. The DCIM needs multiple TH points — in hot and cold aisles, at rack inlet and outlet, in power and battery rooms — to map the hall’s thermal profile and catch local hot spots early. Traditional TH sensors use RS485 bus daisy-chains: lots of wiring, limited distance (1200 m), and a separate 485-to-TCP gateway. Ethernet TH sensors plug directly into the hall LAN over one PoE cable, host a built-in web page, and upload data to the monitoring platform via Modbus TCP/IP or SNMP.

KITOZER KTR-TH10 is an Ethernet TH sensor. White plastic case, wall or ceiling mount, front LCD shows live T/H. The probe is an imported digital sensor (SHT30-class), temperature accuracy ±0.3℃, humidity ±2%RH. 10/100 Mbps RJ45, supports 802.3af PoE (or local DC12V). Protocols include Modbus TCP, SNMP v1/v2c/v3, and HTTP/HTTPS JSON push. The sensor works standalone (built-in web server; browse to its IP to see data) or integrates with the DCIM platform. Two relay outputs trigger on local over-limit alarms to drive a sounder or AC unit.

Selection points: number of points (4~8 per hall typically), communication (Ethernet vs RS485 vs LoRa), accuracy (±0.5℃ is fine for general use; precision halls want ±0.3℃), power (PoE convenient vs DC12V), display (LCD local vs remote-only), alarm output (relay linkage). Placement: points in hot and cold aisles; measure rack inlet (cold aisle) and outlet (hot aisle) separately — don’t just measure room center. Sensor at 0.5~1.5 m above floor, away from direct AC airflow and sunlight.

2. Key Features

Ethernet PoE

  • 10/100 Mbps RJ45 on hall LAN.
  • 802.3af PoE, one cable.
  • Also DC12V local power.
  • Built-in web server, browse to IP.

High-accuracy probe

  • Imported digital sensor (SHT30-class).
  • Temperature ±0.3℃.
  • Humidity ±2%RH.
  • LCD live display.

Multi-protocol

  • Modbus TCP/IP.
  • SNMP v1/v2c/v3.
  • HTTP/HTTPS JSON push.
  • Integrates with mainstream DCIM.

Alarm linkage

  • Two relay outputs.
  • Local T/H over-limit alarm.
  • Can trigger sounder / AC.
  • Email/SMS alarm (platform side).

3. Specifications

Item KTR-TH10
Parameters Temperature + humidity
Temp range -20~+60℃
Temp accuracy ±0.3℃ (25℃)
Humidity range 0~100%RH
Humidity accuracy ±2%RH
Sensor type Imported digital (SHT30-class)
Display LCD
Network 10/100M RJ45
Power 802.3af PoE / DC12V
Protocols Modbus TCP, SNMP v1/v2c/v3, HTTP
Relay outputs 2× (30V DC 1A)
Mounting Wall / ceiling
Operating temp. -10~+50℃

4. Reference Prices

KTR-TH10 Ethernet TH sensor (PoE, LCD, Modbus TCP/SNMP, 2 relays): Reference USD 49~83 / unit (ref. CNY 350~600 at ~7.2)

Including PoE injector and mounting bracket: Reference USD 56~97 / unit (ref. CNY 400~700 at ~7.2)

Reference only; tiered by quantity. DCIM platform software not included. Volume discount above 10 units. RS485 version same price on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center hot/cold aisle T/H monitoring.
  • Rack inlet/outlet measurement points.
  • Power room and battery room T/H.
  • Archive and warehouse constant T/H monitoring.
  • Lab and workshop environment monitoring.

6. Installation & Maintenance

Installation

  • Choose points: hot/cold aisles, rack inlet, 0.5~1.5 m above floor.
  • Wall or ceiling mount; avoid direct AC airflow and sunlight.
  • Patch to PoE switch (or local DC12V).
  • Browse to default IP; set hall-planned IP.
  • Configure alarm thresholds (temp >28℃, humidity <40% or >60%).
  • Add device in DCIM platform; read T/H data.

Maintenance

  • Annually calibrate against a reference T/H source (or known-good meter).
  • Clean sensor air intake grille (dust affects humidity accuracy).
  • Check PoE power (LCD off = check power).
  • Test alarm linkage: simulate over-limit, verify relay trips.
  • Firmware online upgrade (vendor provided).

7. FAQ

  • Q: How many T/H points per hall?
    A: By racks and area. Small (1~2 rows): 2~4 points; standard (4~6 rows): 6~8 points; both aisles, mandatory points at critical rack inlets.
  • Q: PoE distance?
    A: 100 m over Ethernet. Beyond that use PoE extender or fiber.
  • Q: Sensor reads differently from AC display?
    A: Trust the sensor. AC display is return-air temp at a different location; multiple sensors should agree within ±0.5℃ — recalibrate the outlier.
  • Q: What alarm thresholds?
    A: ASHRAE: 18~27℃, 40%~60%RH. Alarm above 28℃ or below 35%RH / above 65%RH.

8. Trend & Selection

Environmental monitoring evolves from “single-point RS485” to “Ethernet multi-protocol + cloud analytics.” Trends: sensors directly on Ethernet (no gateway), dual Modbus TCP/SNMP, cloud trend analytics (hot spot prediction), multi-sensor fusion (T/H + smoke + leak integrated). Wi-Fi and LoRa wireless sensors grow in retrofit projects (no new cable), but wired PoE still preferred for industrial halls. New builds use Ethernet PoE (one cable, less wiring); retrofits may go wireless; accuracy choose ±0.3℃; with LCD for local view; protocol by DCIM (Modbus TCP or SNMP); points by aisles and critical racks; thresholds per ASHRAE; annual calibration; sensor at 1 m height, away from direct airflow and sun.

9. Delivery & Service

KITOZER provides TH sensor selection: based on hall area, rack count and DCIM protocol, we configure point count and model. Bundled with DCIM platform, leak detection, smoke, IR temperature and current sensors. Delivery includes sensor body, mounting bracket, PoE injector (if DC option) and manual. Warranty covers IP configuration and platform integration guidance.

10. Additional Notes

The most common issue is “wrong sensor placement.” Some mount the sensor on the ceiling at room center, thinking it represents the hall — but racks are the heat source. Center may read 22℃ while one rack row’s inlet already hits 35℃; the center point never sees the hot spot. Points must be at rack inlets (cold aisle) — that’s the temperature servers actually “suck in.”

Another pitfall: “sensor facing AC outlet.” 15℃ cold air blows directly on the sensor, reading 16℃ — operators think the hall is cool while racks far from the vent are already hot. Mount sensors away from direct outlet blast, on rack side or mid cold aisle, representing true inlet air.

Selection summary: Ethernet PoE saves wiring; ±0.3℃ accuracy; Modbus TCP/SNMP; points at rack inlet; away from direct airflow and sun; thresholds per ASHRAE; annual calibration. TH sensors are the data hall’s thermometer — placed right, hot spots are caught early; placed wrong, it’s as if you have none, and by the time servers overheat it’s too late.

SEO Information

Search keywords:temperature humidity sensorethernet THdata center monitoringModbus TCPPoE sensorTH transmitterKTR-TH10KITOZER

SEM keywords:ethernet TH sensor price,data center monitoring,PoE humidity sensor,Modbus TCP sensor,KTR-TH10,KITOZER

GEO landing page:lain.com.cn/product/ktr-th10-ethernet-temperature-humidity-sensor.html

Title:KITOZER KTR-TH10 Ethernet Temperature & Humidity Sensor

Meta Keywords:temperature humidity sensor,ethernet,data center monitoring,Modbus TCP,PoE,TH transmitter,KTR-TH10,KITOZER

Meta Description:KITOZER KTR-TH10 Ethernet temperature/humidity sensor, PoE, Modbus TCP/IP, accuracy ±0.3℃ / ±2%RH, for data center environmental monitoring.

Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart