ToggleKITOZER KTR-FL10 Adjustable Rack Floor Base with Extended Range
Brand: KITOZER Series: KTR-FL10 Category: Data Center Engineering / Rack Foundations
Rack baseAdjustable rangeFloor raisingCold-rolled steelLoad extensionCold aisle
1. Overview
Data center racks sit on anti-static raised floors, and below the floor is the plenum. A rack base (plinth) raises the rack off the floor so cold air from below can enter the rack inlet. The base does three jobs: it raises the rack to form a bottom-air supply path; it carries load, transferring rack and equipment weight evenly to the structural slab; and it seals, preventing cold air from leaking into the hot aisle — especially important in cold-aisle containment. Traditional bases are fixed height (commonly 100 mm), but hall floor heights vary (150~400 mm), so fixed bases often do not line up. Battery cabinets and power distribution cabinets are also much heavier than server racks, exceeding a standard base’s rating. An adjustable, extended-range plinth solves both height mismatch and load capacity.
KITOZER KTR-FL10 is an adjustable extended-range rack base. The frame is bent and welded from 2.0 mm cold-rolled steel, powder-coated (gray-white or black). Height adjusts from 100~300 mm via threaded leveling feet and multiple mounting-hole positions, fitting different floor heights. Internal sizes suit standard 600/800 mm-wide racks; depth 600~1200 mm selectable. Static load reaches 1500 kg per rack (a standard base is about 800 kg), suitable for battery cabinets, PDU cabinets, and UPS racks. Blind panels with sealing strips around the base complete the bottom-supply seal when paired with cold-aisle containment. Leveling feet are adjustable, so no floor cutting is needed.
Selection points: rack width (600/800/900 mm), depth, total equipment weight (ordinary server racks: 800~1000 kg is enough; battery/UPS cabinets choose the 1500 kg class), floor height (sets the base’s lower and upper adjustment limits), whether sealed blind panels are needed (mandatory for containment), and cable pass-throughs. Note: heavier is not always better — coordinate with floor load capacity; if the slab is limited, spread the base footprint.
2. Key Features
Height adjustable
- 100~300 mm continuous range.
- Threaded feet + multi-position holes.
- Fits different floor heights.
- No floor cutting.
Extended load
- 2.0 mm cold-rolled steel frame.
- 1500 kg per rack.
- For battery/UPS/PDU cabinets.
- Reinforced welds.
Sealed panels
- Sealing strips on all sides.
- Cold-aisle containment ready.
- Prevents cold-air bypass.
- Removable blind panels.
Leveling feet
- Threaded leveling feet.
- Compensates uneven floor.
- Locks after leveling.
- Easy installation.
3. Specifications
| Item | KTR-FL10 |
|---|---|
| Model | KTR-FL10 |
| Frame material | 2.0 mm cold-rolled steel |
| Finish | Powder-coated |
| Adjustment range | 100~300 mm |
| Inner width | 600/800/900 mm selectable |
| Depth | 600~1200 mm selectable |
| Static load | 1500 kg/rack |
| Sealed panels | Standard |
| Foot adjustment | ±15 mm |
| Cable pass-through | Optional |
| Color | Gray-white / black |
| Mounting | Anchor / non-anchor option |
4. Reference Prices
KTR-FL10 adjustable rack base (600×1000 mm, 1500 kg, sealed panels): Reference USD 39~76 / pc (ref. CNY 280~550 at ~7.2)
KTR-FL10H heavy extended (800×1200 mm, 2000 kg, cable pass-through): Reference USD 63~111 / pc (ref. CNY 450~800 at ~7.2)
Reference only; tiered by size and load class. Racks not included. Volume discount above 10 pcs. Custom sizes available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Modular cold aisle server rack bases.
- Heavy bases for battery/UPS/PDU cabinets.
- Halls with mismatched raised-floor heights.
- Bottom-supply plenum sealing retrofit.
- Legacy hall rack raising projects.
6. Installation & Maintenance
Installation
- Set base height to match floor level; pre-adjust feet.
- Place base, level with a spirit level, lock feet.
- Bolt rack to base mounting holes.
- Fit side blind panels; seal tight to floor.
- Verify bottom-supply path is unobstructed and panels gap-free.
Maintenance
- Quarterly check foot tightness (vibration loosens).
- Check blind panels stay seated (bypass kills efficiency).
- For heavy cabinets, inspect welds for deformation.
- Clean dust inside base (prevents blowing into rack).
- Re-level after moving a rack.
7. FAQ
- Q: What’s the relation between base load and slab load?
A: Base load is the plinth’s own strength; slab load is per-square-meter limit. For heavy cabinets verify both and spread the footprint if needed. - Q: Do feet need expansion bolts?
A: Ordinary halls: no anchor (self-weight + rack bolts); seismic zones require anchor bolts. - Q: How to set base height?
A: Base top must be flush with raised-floor top, aligning the rack inlet with under-floor supply. - Q: Are sealed panels mandatory?
A: Yes for cold-aisle containment — otherwise cold air bypasses through base gaps, crashing cooling efficiency.
8. Trend & Selection
Bases evolve from “fixed iron frame” to “adjustable + sealed + integrated cabling.” Trends: bases designed as one system with cold-aisle containment (blind/end panels as a set), quick height adjustment (snap-in replacing threads), built-in cable trays and PDU mounts, and reinforced bases for heavy cabinets. Selection: measure floor height first, then pick adjustment range; heavy cabinets (battery/UPS) choose 1500 kg+; containment requires sealed panels; level and lock feet; verify slab load. The base is unobtrusive, yet it underwrites cold-aisle efficiency and rack stability — wrong height bypasses supply, insufficient load risks heavy cabinets.
9. Delivery & Service
KITOZER provides base selection: by rack size, equipment weight, floor height, and containment layout, we configure base dimensions, load class, and sealed panels. Bundled with cold aisle racks, end doors, roof, and blind panels. Delivery includes base frame, feet, sealed panels, and bolt pack. Warranty covers height calculation and leveling guidance.
10. Additional Notes
The most common fault: “base top not flush with floor.” Some just set the rack on the floor, so under-floor cold air never reaches the inlet, and servers pull hot-aisle return through the front — PUE climbs. Base top must be flush with the floor so the inlet aligns with bottom supply.
Another pitfall: “light base under a heavy cabinet.” A charged battery bank alone is hundreds of kg; with cabinet self-weight, a light base’s welds deform and the rack tilts — a safety hazard. Battery and UPS cabinets must use reinforced 1500 kg+ bases, and slab load must be checked — not just the base rating.
Selection summary: set height by floor level; heavy cabinets get reinforced load; containment needs sealed panels; level and lock feet; verify slab. The base is the cold aisle’s foundation — right height, enough load, tight seal, and bottom air actually reaches the rack; otherwise containment is decorative.
SEO Information
Search keywords:rack baseadjustable rack plinthfloor raising basecold-rolled steel plinthload extension basecold aisle rackKTR-FL10KITOZER
SEM keywords:rack base price,adjustable rack plinth,floor raising base,cold aisle base,KTR-FL10,KITOZER
GEO landing page:lain.com.cn/product/ktr-fl10-adjustable-rack-floor-base-extended-range.html
Title:KITOZER KTR-FL10 Adjustable Rack Floor Base with Extended Range
Meta Keywords:rack base,adjustable range,floor raising,cold-rolled steel,cold aisle plinth,KTR-FL10,KITOZER
Meta Description:KITOZER KTR-FL10 adjustable rack floor base, cold-rolled steel, raising range 100~300 mm adjustable, load extension, for modular cold aisle racks.
Anchor: KITOZER by Guangzhou Laian · Modular cold aisle components