ToggleKITOZER KTR-FL12 Rack Plinth (Heavy-Duty Steel)
Brand: KITOZER Series: KTR-FL12 Category: Modular Cold Aisle 2 / Rack Support
rack plinthheavy duty steelcabinet baseload-bearingadjustable base
1. Overview
KITOZER KTR-FL12 is a heavy-duty steel plinth installed under a rack to lift it off the raised floor. Why does a data hall need a plinth? Three reasons: first, under the raised floor run power/network trays and the CRAH plenum — the rack cannot sit directly on floor tiles and must be supported by the plinth; second, the plinth lifts the rack 100~300 mm so cables and air ducts can enter the rack’s bottom cable gland; third, a fully loaded rack weighs 800~1200 kg and cannot press on a 600×600 anti-static floor tile rated only 300~500 kg/tile — the plinth must transfer the load to the structural slab or dedicated beams.
KTR-FL12 uses a welded/bolted structural-steel frame: channels or square tubes 2.0~3.0 mm thick, powder-coated for corrosion resistance. Static load capacity is 1000~1500 kg per rack, with seismic design for intensity-8 zones. Common heights are 100/150/200 mm, customizable to 300 mm. Adjustable leveling feet at the bottom fine-tune ±10 mm for uneven slabs. Removable side panels open for cable entry and close after to preserve cold-aisle containment.
Vs integrated rack bases: some racks ship with a folded bottom frame, but it is weak and fixed-height; KTR-FL12 is an independent heavy plinth engineered for the actual rack weight and slab load, compatible with any 19-inch rack brand. In modular cold-aisle systems, a row of racks shares one continuous plinth that also acts as the cold-aisle bottom sill, sealing hot and cold air at floor level.
2. Key Features
Heavy-duty steel frame
- Channel/square-tube welded frame, 2.0~3.0 mm wall.
- 1000~1500 kg static load per rack, for high-density racks.
- Intensity-8 seismic design with seismic bolts.
Height & adjustability
- Standard 100/150/200 mm, customizable to 300 mm.
- Bottom adjustable feet ±10 mm leveling.
- Fits 600×1000, 600×1200, 800×1000 rack widths/depths.
Cable entry & containment
- Removable side panels for top/bottom cable entry.
- Brush grommet plate optional, prevents cold-air leakage.
- Mates with cold-aisle door/roof bottom edge.
Surface finish
- Phosphated + electrostatic powder coat, grey-white or black.
- ≥10-year indoor corrosion protection.
- Welds ground smooth, no burrs.
3. Specifications
| Item | KTR-FL12-100 | KTR-FL12-150 | KTR-FL12-200 |
|---|---|---|---|
| Plinth height | 100 mm | 150 mm | 200 mm |
| Rack W×D | 600×1000 mm | 600×1000/1200 mm | 800×1000/1200 mm |
| Static load | 1000 kg | 1200 kg | 1500 kg |
| Structure | Bolted | Bolted | Welded + bolted |
| Steel wall | 2.0 mm | 2.5 mm | 3.0 mm |
| Adjust range | ±10 mm | ±10 mm | ±15 mm |
| Side panels | Removable | Removable + brush | Removable + brush |
| Finish | Grey-white coat | Grey-white/black | Grey-white/black |
| Seismic | Intensity 7 | Intensity 8 | Intensity 8 |
4. Reference Prices
KTR-FL12-100 standard plinth (100 mm, 600×1000, bolted, coated): Reference USD 49~111 / pc (ref. CNY 350~800 at ~7.2)
KTR-FL12-150/200 tall/heavy (150/200 mm, 800 depth, brush plate, intensity-8 seismic): Reference USD 125~306 / pc (ref. CNY 900~2,200 at ~7.2)
Reference only; final quote depends on height, rack depth/width, load class, side panels and color. Continuous row plinths priced per linear meter; rack and floor excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center raised-floor rack load support.
- Modular cold-aisle bottom sill.
- UPS, power distribution and battery cabinet bases.
- Slab areas with insufficient load rating.
- Rooms needing bottom cable entry (power/network).
6. Installation & Maintenance
Installation
- Locate plinth positions on slab per rack layout.
- Set adjustable feet, level with spirit level.
- Bolt row plinths together in line.
- Crane rack onto plinth, fix with M12 bolts.
- Cut floor tiles, tile edge rests on plinth side panel.
- Install brush grommet plate and close side panels.
- Verify: no plinth deformation under full load.
Maintenance
- Check rack-to-plinth bolts periodically.
- Watch for settlement or deformation.
- Reattach loose brush plates.
- Touch up scratched powder coat.
- Recheck load after adding/removing equipment.
7. FAQ
- Q: Can’t the rack sit directly on anti-static tiles?
A: No. Tiles are rated 300~500 kg; a loaded rack at 800~1200 kg will crush them. Under-floor trays and ducts also need the rack lifted. Load must transfer to the slab via the plinth. - Q: How to choose plinth height?
A: By under-floor tray and duct height. Raised floor finish is typically 300 mm above slab; plinth height = under-floor cable clearance (commonly 100~200 mm). Bottom entry uses tall plinth, top entry uses short. - Q: Should a row’s plinths be joined?
A: Cold-aisle containment requires them bolted together and sealed to the cold-aisle door and roof bottom, otherwise cold air leaks at the base. Non-containment rooms can use independent plinths. - Q: What if the slab can’t carry the load?
A: Add steel beams under the slab or spread load with a steel plate on top; the plinth only transfers rack load to the slab — the slab itself must be reinforced first.
8. Trend & Selection
Rack plinths evolve from “simple spacer” to “load + containment + seismic integrated”: rack power density rises from 5 kW to 15~30 kW per rack, weight follows, and modular cold aisles fold the plinth into the containment envelope requiring airtight mating at the bottom. The trend is pre-installed brush plates, adjustable leveling feet and matching cold-aisle finish. Select load class by fully loaded rack weight with 1.5× margin; height by under-floor tray; depth/width by actual rack (600 vs 1200 is a big difference); use continuous brush-plinth for cold aisles; seismic per local intensity (usually 8); match powder-coat color to racks for visual uniformity.
9. Delivery & Service
KITOZER provides plinth selection: based on rack layout, rack weight, slab load and cold-aisle containment requirements, we design plinth size, height, load and side-panel configuration. We produce the plinth layout drawing (positioning, joints, floor cutouts, cable-entry direction). Bundled with racks, cold-aisle containment and raised floors. Delivery includes plinth frame, adjustable feet, connecting bolts, removable side panels and brush grommet plates. Warranty covers leveling guidance.
10. Additional Notes
The most common pitfall is “sizing the plinth by the empty rack weight”. The rack arrives empty at 200 kg, so the plinth is rated for 500 kg; once loaded with servers it hits 1000 kg, the plinth bends and the rack tilts. Always size by fully loaded weight (servers + switches + cable managers all full) with 1.5× margin.
Another pitfall: “gaps between plinth and cold-aisle bottom”. Cold-aisle containment is about airtightness; every gap — plinth-to-floor, plinth-to-rack, end-to-end in a row — leaks cold air. Individually small, but across a row they add up and overheat the cold aisle. Side panels must seal tightly and brush plates must be compressed.
Selection summary: size by fully loaded weight with margin; height by under-floor trays; depth/width matched to rack; use continuous brush plinth for cold aisles; seismic per local intensity; bolt the row airtight. The plinth is the rack’s foundation — a weak foundation means even expensive racks stand crooked, and even a sealed cold aisle leaks.
SEO Information
Search keywords:rack plinthheavy duty steelcabinet baseload bearingadjustable plinthKTR-FL12KITOZER
SEM keywords:rack plinth price,heavy duty steel base supplier,data center rack plinth,cold aisle cabinet base,KTR-FL12,KITOZER
GEO landing page:lain.com.cn/product/ktr-fl12-heavy-duty-steel-rack-plinth.html
Title:KITOZER KTR-FL12 Rack Plinth (Heavy-Duty Steel)
Meta Keywords:rack plinth,heavy duty steel,cabinet base,load bearing,adjustable base,KTR-FL12,KITOZER
Meta Description:KITOZER KTR-FL12 heavy-duty steel rack plinth, 1000~1500kg load, 100/150/200mm adjustable height, brush cable entry, intensity-8 seismic, for cold aisle containment.