1. Overview

KITOZER KTR-FB12R is a 1U rack-mount fiber distribution box (ODF unit), the core termination and patch-management device for data hall low-voltage cabling. Backbone cable enters the cabinet and must be terminated, spliced and patched inside the box: backbone fibers splice to pigtails, pigtail SC connectors plug into front-panel adapters, and equipment patch cords run from adapters to switch optical ports. KTR-FB12R is a 1U, 19-inch rack, 12-SC fully loaded unit: internal slide-out splice tray, front panel pre-loaded with 12 SC duplex adapters (24 fibers), and 12 SC pigtails included. On arrival, simply splice the cable to the pigtails.

SC is the traditional square fiber connector; while new builds prefer high-density LC, installed SC links remain widespread. KTR-FB12R targets retrofits and existing halls, providing standard 12-SC termination. The slide-out tray pulls out for splicing and slack storage with a bend radius ≥30 mm to avoid added loss. Cable enters from the rear, patch cords exit the front for neat routing.

“Fully loaded” means the box ships with adapters and pigtails pre-installed (12 SC single-mode UPC pigtails, 1.5 m) versus an empty chassis. This eliminates on-site procurement and assembly; factory consistency is better. OM3 multimode or APC polish available on request.

2. Key Features

1U 12 SC loaded

  • 1U, 19-inch rack mount.
  • 12 SC duplex adapters (24 fibers).
  • 12 SC pigtails pre-installed.

Slide-out splice tray

  • Pulls out for working space.
  • Bend radius ≥30 mm.
  • Splice-protection sleeve slots.

Chassis & finish

  • 1.2 mm cold-rolled steel, powder coat.
  • Rear/front cable entries with rubber grommets.
  • Front label strip for port numbering.

Fiber compatibility

  • Single-mode 9/125 µm (standard).
  • OM3 multimode, APC optional.
  • Ceramic-sleeve adapters and pigtails.

3. Specifications

Item KTR-FB12R
Form factor 1U 19-inch rack
Ports 12 SC duplex (24 fibers)
Adapters SC single-mode UPC (standard)
Pigtails SC-UPC SM 1.5 m × 12
Splice tray Slide-out, bend ≥30 mm
Chassis 1.2 mm steel, powder coat
Mount 19-inch rack screws
Cable type Indoor/outdoor into cabinet
Operating temp -10~60℃
Color Black (RAL9005)

4. Reference Prices

KTR-FB12R 1U 12 SC SM loaded (adapters + pigtails + tray): Reference USD 25~44 / unit (ref. CNY 180~320 at ~7.2)

KTR-FB12R OM3 / APC version: Reference USD 31~53 / unit (ref. CNY 220~380 at ~7.2)

Reference only; priced by fiber type, polish and quantity. Backbone cable and patch cords excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Cabinet fiber termination and patching.
  • LV room backbone-to-horizontal cross-connect.
  • Retrofit projects on existing SC links.
  • Small enterprise self-built fiber aggregation.
  • Industrial fiber termination.

6. Installation & Maintenance

Installation

  • Bolt box to rack square-hole rails.
  • Feed cable through rear entry; anchor strength member.
  • Pull out tray; strip cable jacket.
  • Splice each fiber to SC pigtail; seat sleeves in tray.
  • Coil slack neatly in tray.
  • Plug pigtail SC into front adapter.
  • Label front ports.

Maintenance

  • Dust-cap unused ports.
  • Clean end faces before mating.
  • Sample-test link loss annually.
  • Pull/push tray gently.
  • Reapply faded labels.

7. FAQ

  • Q: Can SC and LC boxes interchange?
    A: No — panel cutouts and adapter types differ. Standardize LC for new builds, SC for existing SC links.
  • Q: Price difference between loaded and empty?
    A: Loaded is tens of yuan more (12 adapters + 12 pigtails), but saves on-site procurement and labor — worth it.
  • Q: 24 vs 48 fibers in 1U?
    A: 1U holds 12 SC duplexes (24 fibers); choose 2U or LC duplex 1U (48 fibers) for higher density.
  • Q: Bend radius requirement?
    A: Minimum 30 mm (~10× cable diameter); tighter creates macrobend loss. The tray is designed for ≥30 mm.

8. Trend & Selection

New builds trend toward high-density LC and MPO pre-termination, but SC remains in retrofits and SMB projects. KTR-FB12R targets these with an economical SC termination. Select: SC SM/OM3 by link type; loaded for on-site labor savings; 1U 12-port for small capacity; slide-out tray for serviceability; labels and dust caps mandatory; batch-order adapters and pigtails from the same lot.

9. Delivery & Service

KITOZER supplies boxes in volume: based on fiber count and port density, we configure 12-SC loaded units, bundled with backbone cable, SC patch cords and splicing service. Delivery includes chassis, adapters, pigtails and tray. Warranty covers splice-loss testing and defect replacement.

10. Additional Notes

The most common install error: “failing to anchor the cable strength member.” If only the fibers are spliced while the metal strength member hangs free, tugs at the cable pull the splices apart. Anchor the strength member to the chassis ground lug and strain-relief the outer jacket.

Another pitfall: “messy slack coiling.” Contractors stuff excess fiber into the tray with tight kinks below 30 mm bend radius, causing excess loss on testing. Coil slack in neat figure-8 or loops ≥60 mm diameter.

Selection summary: 1U 12 SC loaded; slide-out tray; SM UPC standard; anchor strength member; coil slack ≥30 mm; label and dust-cap. The fiber box is the optical junction box — neat termination makes future service painless.

SEO Information

Search keywords:fiber box12 SCrack ODF1U loadedsplice trayKTR-FB12RKITOZER

SEM keywords:12 SC fiber box price,rack ODF supplier,1U fiber termination box,loaded fiber patch panel,KTR-FB12R,KITOZER

GEO landing page:lain.com.cn/product/ktr-fb12r-1u-12sc-fiber-box.html

Title:KITOZER KTR-FB12R 1U Rack Fiber Box (12 SC Loaded)

Meta Keywords:fiber box,12 SC,rack ODF,1U loaded,splice tray,KTR-FB12R,KITOZER

Meta Description:KITOZER KTR-FB12R 1U rack fiber box, 12 SC fully loaded with adapters and pigtails, slide-out splice tray.

Anchor: KITOZER by Guangzhou Laian · Low-voltage systems

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart