KITOZER SC duplex OM4 multimode adapter

KITOZER KTR-SCOM6 SC Duplex OM4 Multimode Fiber Adapter

Brand: KITOZER Series: KTR-SCOM6 Category: Data Center Engineering / Fiber Cabling

fiber adapterSC duplexOM4 multimodefiber couplerstructured cablingKTR-SCOM6

[Product image: KITOZER KTR-SCOM6 SC duplex OM4 multimode adapter, blue coupling flange]

1. Overview

KITOZER KTR-SCOM6 is an SC duplex OM4 multimode fiber adapter, commonly called a fiber flange or coupler — a passive component that precisely aligns two SC fiber connectors in the structured cabling system. In the data hall, a server NIC or switch optical module has an SC patch cord running to the fiber patch panel; on the back, pigtails are fusion-spliced to the cable and terminate at one end of the adapter. The other end accepts a second patch cord to horizontal or backbone cabling. The adapter keeps the two SC ferrules perfectly coaxial so optical signals couple from one fiber to the other with minimal loss.

OM4 is the latest multimode standard (IEC 60793-20 A1a.3), 50/125μm core, laser-optimized, supporting 10 Gb/s up to 100 m and 40/100 Gb/s parallel up to 100 m at 850 nm. OM4 adapters are identified by color — aqua (light blue-green) flange. KTR-SCOM6 uses a duplex SC housing: two SC adapters side-by-side in one body, RX and TX fixed together to prevent cross-connect. The zirconia ceramic ferrule is precision-bored to φ2.498±0.0001 mm, with ≥1000 mating cycles.

The PC-polished end face delivers insertion loss ≤0.2 dB and return loss ≥50 dB. Metal or plastic housing options with snap-in clips mount directly into patch-panel cutouts. KTR-SCOM6 also offers hybrid adapters (SC-LC, SC-FC) for connecting different optical-module connector types.

2. Key Features

OM4 multimode dedicated

  • Aqua flange identifies OM4.
  • Supports 10G/40G/100G multimode.
  • 50/125μm backward-compatible with OM3.

SC duplex integrated

  • RX/TX paired, prevents misplug.
  • Top-bottom layout matches SC cords.
  • Snap-in to patch panel.

Precision ceramic ferrule

  • Zirconia ceramic ferrule.
  • Insertion loss ≤0.2 dB.
  • Return loss ≥50 dB.
  • ≥1000 mating cycles.

Multiple hybrid options

  • SC-SC straight.
  • SC-LC / SC-FC hybrid optional.
  • Metal or plastic housing.

3. Specifications

Item KTR-SCOM6
Connector type SC duplex (top-bottom)
Fiber type OM4 multimode 50/125μm
Flange color Aqua
Ferrule Zirconia ceramic φ2.498mm
End face PC polish
Insertion loss ≤0.2 dB
Return loss ≥50 dB
Mating cycles ≥1000
Wavelength 850nm / 1300nm
Operating temp -20~70℃
Housing Plastic / zinc alloy

4. Reference Prices

KTR-SCOM6 SC duplex OM4 adapter (plastic housing, SC-SC): Reference USD 1.1~2.1 / pc (ref. CNY 8~15 at ~7.2)

KTR-SCOM6 SC duplex OM4 adapter (zinc housing, SC-LC hybrid): Reference USD 2.5~4.9 / pc (ref. CNY 18~35 at ~7.2)

Reference only; priced by housing and hybrid type. Bulk (50/pack) pricing on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Fiber patch panel adapter slots in data centers.
  • Fiber splicing boxes and termination boxes.
  • Switch optical modules to horizontal cable.
  • OM4 10G/40G links.
  • Enterprise and campus MDF/IDF rooms.

6. Installation & Maintenance

Installation

  • Confirm adapter matches patch cords (SC-SC).
  • Press adapter into panel cutout until clip snaps.
  • Back: insert spliced pigtail into inner ferrule.
  • Front: plug SC cord, observe RX/TX polarity.
  • Test insertion loss with light source/power meter.
  • Cap unused ports with dust plugs.

Maintenance

  • Clean ferrules with alcohol swab before every mating.
  • Keep unused ports capped.
  • Periodically test link loss with power meter.
  • Reseat loose adapters.
  • Replace scratched or blackened adapters.

7. FAQ

  • Q: Can OM3 and OM4 adapters mix?
    A: Physically compatible but no benefit on OM3 links; OM3 adapters cap OM4 bandwidth. Use OM4 end-to-end.
  • Q: Blue vs aqua flange?
    A: Pure blue = OS2 single-mode UPC; aqua = OM4 multimode; orange = OM1/OM2. Check the flange before plugging.
  • Q: Can I split the duplex adapter?
    A: It is one-piece; do not split. Splitting loses RX/TX pairing and causes polarity errors.
  • Q: What insertion loss is acceptable?
    A: ≤0.2 dB per adapter. Total link loss budget is calculated per OM4 10Gbps/100 m.

8. Trend & Selection

Data centers scale to 40G/100G/400G; OM4 multimode is the mainstream short-reach, cost-effective in-campus cabling. The adapter — the most numerous passive component — should be: consistent aqua OM4; integrated duplex to prevent polarity errors; zirconia PC-polished ferrule; snap-in mounting; paired with end-face cleaning tools. Half of a link’s performance depends on adapter termination quality.

9. Delivery & Service

KITOZER supplies SC duplex OM4 adapters in packs, matched to the patch panel/box port count and OM4 link design. We provide the termination drawing labeling each port and its route. Warranty covers insertion-loss spot checks and defect replacement.

10. Additional Notes

The most common mistake: mating without cleaning the end face. Pulling a patch cord straight from the bag and plugging it in, dust on the ferrule gets burned into the end face by high-power laser, causing permanent loss. Clean every ferrule with an alcohol pen before every mating — this is the golden rule of fiber work.

Another pitfall: single-mode/multimode cross-plugging. A yellow SM cord physically fits an OM4 adapter, but mode-field mismatch causes huge loss and a dead link. Check jacket and flange color before plugging.

Selection summary: SC duplex OM4; aqua flange; ceramic ferrule; ≤0.2 dB; snap-in; clean end face. Tiny as it is, the adapter is where link loss begins — one dirty adapter can take down an entire 10G link.

SEO Information

Search keywords:SC fiber adapterOM4 multimodeSC duplex couplerblue flangepatch panelKTR-SCOM6KITOZER

SEM keywords:SC duplex OM4 adapter price,blue fiber coupler supplier,multimode SC flange,patch panel adapter,KTR-SCOM6,KITOZER

GEO landing page:lain.com.cn/product/ktr-scom6-sc-duplex-om4-adapter.html

Title:KITOZER KTR-SCOM6 SC Duplex OM4 Multimode Fiber Adapter

Meta Keywords:SC fiber adapter,OM4 multimode,SC duplex coupler,blue flange,patch panel,KTR-SCOM6,KITOZER

Meta Description:KITOZER KTR-SCOM6 SC duplex OM4 multimode fiber adapter with blue flange for fiber patch panels and boxes.

Anchor: KITOZER by Guangzhou Laian · Structured cabling

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart