Table of Contents
ToggleKITOZER KTR-FL14 Adjustable Cabinet Plinth (Front-Rear, Heavy Duty)
Brand: KITOZER Series: KTR-FL14 Category: Data Center Engineering / Cabinet Infrastructure
cabinet plinthfront-rear adjustableload basemodular cold aisleadjustable plinthKTR-FL14
1. Overview
KITOZER KTR-FL14 is an adjustable steel plinth installed under 19-inch server racks to lift the cabinet, align rows, and absorb uneven-floor tolerance. In modular cold-aisle containment, a row of racks must butt together to form a sealed aisle; every cabinet’s front-to-back position must line up so roof panels and end doors seal tightly. But data-center floors — especially the concrete under raised flooring — are never perfectly flat. Racks set directly on the floor end up misaligned, with uneven gaps and leaking containment. KTR-FL14 uses front-rear telescoping feet so installers can fine-tune each cabinet’s position after it is in place, lining the whole row into a straight line.
The plinth is a frame of front/rear main beams, left/right stringers, and four adjustable feet. The main beams have slotted holes; rack uprights bolt to the slots with M12 bolts — loosen them and slide the cabinet ±25 mm front-to-back, then re-tighten. Height is typically 100 or 150 mm, leaving under-floor cable space and matching the containment floor. Four feet with rubber anti-vibration pads sit on the concrete or pedestal, spreading the load.
KTR-FL14 main beams are bent from 2.0 mm cold-rolled steel, welded and powder-coated; rated load ≥1000 kg per plinth, enough for a fully loaded server rack (~800 kg). The front-rear adjustment is especially useful for cold-aisle retrofit projects — when existing racks are misaligned, you do not need to move the cabinet; just loosen the slot bolts and slide it into line. Side cable openings let power and network cables pass under the plinth into the rack.
2. Key Features
±25 mm front-rear adjust
- Slotted holes allow post-install fine-tuning.
- Loosen M12 bolts, slide front-rear.
- Whole row can be aligned.
Heavy-duty load
- 2.0 mm cold-rolled main beams.
- ≥1000 kg per plinth.
- Handles full server racks.
Anti-vibration feet
- Four rubber pads.
- Spreads load, protects floor.
- Compensates minor unevenness.
Cold-aisle ready
- 100/150 mm height.
- Side cable openings.
- Aligns with roof panels and end doors.
3. Specifications
| Item | KTR-FL14 |
|---|---|
| Type | Framed adjustable rack plinth |
| Adjustment | Front-rear ±25 mm |
| Method | Slotted hole + M12 bolt |
| Height | 100 / 150 mm |
| Load rating | ≥1000 kg |
| Beam thickness | 2.0 mm cold-rolled steel |
| Finish | Powder coat |
| Rack fit | 19-inch standard rack |
| Feet | 4 rubber anti-vibration pads |
| Cable opening | Side cutout |
| Color | Black / gray (optional) |
4. Reference Prices
KTR-FL14 adjustable plinth (100 mm, 800×1000 rack, single): Reference USD 39~63 / unit (ref. CNY 280~450 at ~7.2)
KTR-FL14 adjustable plinth (150 mm, 800×1200 rack, heavy duty): Reference USD 67~108 / unit (ref. CNY 480~780 at ~7.2)
Reference only; priced by size, height, load rating. Bulk (10+) on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Cold-aisle containment rack plinths.
- New data hall rack rows.
- Retrofit containment on existing racks.
- Raised-floor cable routing.
- Heavy server rack load reinforcement.
6. Installation & Maintenance
Installation
- Mark floor positions per row drawing.
- Set plinth frame on the marks.
- Level the four feet.
- Lower the rack onto the plinth.
- Align rack uprights with slots, insert M12 bolts.
- Loosen bolts, slide rack front-rear to align row.
- Tighten bolts diagonally.
- Route power cables through side opening.
Maintenance
- Check plinth bolts annually.
- Inspect feet for aging/cracking.
- Re-tighten slot bolts after rack moves.
- Clear dust and cables under plinth.
- Touch up chipped powder coat.
7. FAQ
- Q: Is ±25 mm enough adjustment?
A: Enough for floor unevenness and install tolerance. If existing racks are off by more, reposition the cabinet itself; the plinth is for row alignment only. - Q: Can the plinth sit directly on raised floor tiles?
A: No. Floor tiles cannot carry the load. The plinth must rest on concrete below or dedicated struts, passing through a floor cutout. - Q: 100 mm vs 150 mm?
A: 100 mm for standard cold aisle; 150 mm if under-floor cable space is tight. Match roof-panel height. - Q: Is 1000 kg enough?
A: A loaded rack is ~800 kg, so 25% margin. Battery cabinets and heavy UPS need reinforced plinths.
8. Trend & Selection
Modular cold-aisle containment moves toward fast deployment and scalability; plinths evolve from fixed to adjustable, prefabricated units. Select: ±25 mm front-rear adjust for row alignment; ≥1000 kg load; height matched to floor and roof panels; side cable openings; anti-vibration feet. Unseen as it is, the plinth decides containment sealing — a straight row means roof panels and end doors do not leak cold air.
9. Delivery & Service
KITOZER supplies adjustable plinths sized to the rack layout and raised-floor height, with four rubber feet and M12 bolts. We provide the plinth layout drawing and install guide. Warranty covers bolt and foot replacement.
10. Additional Notes
A common mistake: setting the rack on an unleveled plinth. Dropping the frame on the floor and hoisting the cabinet on, one foot hangs in the air; the rack is overloaded on one corner, doors warp and gear vibrates. Level the four feet with a spirit level before loading.
Another pitfall: leaving the slot bolts loose. After alignment, forgetting to tighten diagonally lets vibration drift the rack, opening gaps in the containment. Tighten in diagonal order after alignment.
Selection summary: ±25 mm adjust; ≥1000 kg; 100/150 mm; on concrete not floor tiles; level and diagonally tighten. The plinth is the containment’s foundation — a straight foundation means the whole row lines up.
SEO Information
Search keywords:cabinet plinthfront-rear adjustable plinthheavy duty rack basecold aisle plinthadjustable baseKTR-FL14KITOZER
SEM keywords:adjustable rack plinth price,front-rear telescoping base,heavy duty cabinet base,cold aisle plinth,KTR-FL14,KITOZER
GEO landing page:lain.com.cn/product/ktr-fl14-adjustable-cabinet-plinth.html
Title:KITOZER KTR-FL14 Adjustable Cabinet Plinth (Front-Rear, Heavy Duty)
Meta Keywords:cabinet plinth,front-rear adjustable plinth,heavy duty rack base,cold aisle plinth,adjustable base,KTR-FL14,KITOZER
Meta Description:KITOZER KTR-FL14 front-rear adjustable rack plinth with telescoping feet, heavy-duty, for 19-inch racks and cold-aisle containment.
Anchor: KITOZER by Guangzhou Laian · Modular cold aisle
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com