Brand: KITOZER Series: KTR-FL15 Category: Data Center Engineering / Rack Plinth
Rack plinthHeight adjustableLoad baseCold aisle baseKTR-FL15

1. Overview
KITOZER KTR-FL15 is a rack plinth — a base placed under a server cabinet to lift and support it. Setting a cabinet directly on a datacenter floor raises issues: raised floor tiles have limited load and can deform; the bottom needs space for cabling and airflow; uneven floors tilt the cabinet, impairing door closure and equipment. The plinth solves all three: transfers weight to the structure, lifts the base for cabling/airflow, and levels with adjustable feet.
KTR-FL15 is welded from bent cold-rolled steel with black powder coat. Frame sizes match cabinet width and depth (600/800/900/1100mm deep). Height adjusts 50~200mm via lift screws and levelling feet; on site you turn the feet to level the cabinet within ±20mm. Load rating 800~1500kg per unit, suiting fully loaded server racks. Side baffles (toe-kick panels) hide bottom cabling and align with cold-aisle containment doors.
Two uses: on raised floor, the plinth sits on floor-strengthening supports and transfers load to under-floor steel; on concrete, it lands directly and levels via feet. In modular cold aisles, a row of plinths must line up in a straight row — joined by brackets — keeping cabinets aligned and containment doors flush.
2. Key Features
Height adjustable
- 50~200mm adjustable.
- Feet level ±20mm.
- Lift screws for easy on-site work.
Heavy load
- 800~1500kg per unit.
- Bent/welded steel, reinforced.
- Suits fully loaded racks.
Cold aisle ready
- Plinths joined row by row.
- Side baffles align containment doors.
- Matches cabinet column hole pattern.
Floor types
- Raised floor: with support reinforcement.
- Concrete: direct landing and level.
- Anti-static coating, grounded.
3. Specifications
| Item | KTR-FL15-8 | KTR-FL15-11 | KTR-FL15-15 |
|---|---|---|---|
| Load (kg) | 800 | 1100 | 1500 |
| Height (mm) | 50~150 | 80~200 | 80~200 |
| Leveling (mm) | ±15 | ±20 | ±20 |
| Cab depth (mm) | 600~800 | 800~1000 | 1000~1200 |
| Steel (mm) | 2.0 | 2.5 | 3.0 |
| Finish | Black powder | Black powder | Black powder |
| Joining | Bracket bolts | Bracket bolts | Bracket bolts |
| Baffle | Optional | Optional | Included |
4. Reference Prices
KTR-FL15-8 standard plinth (800kg, 50~150mm, 600~800mm deep cab, no baffle): Reference USD 25~56 / unit (ref. CNY 180~400 at ~7.2)
KTR-FL15-15 heavy plinth (1500kg, 80~200mm, 1000~1200mm deep, with baffle): Reference USD 63~125 / unit (ref. CNY 450~900 at ~7.2)
Reference only; price varies by load, depth, height and baffle option. Row joining brackets billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Modular cold aisle row bases.
- Raised-floor datacenter load support.
- Concrete-floor room leveling/lifting.
- High-density fully loaded racks.
- Hot/cold aisle containment bottom join.
6. Installation & Maintenance
Installation
- Mark positions per cabinet layout.
- Raised floor: add under-floor reinforcement at each plinth to transfer load to steel.
- Concrete: land directly and rough-level feet.
- Lift cabinet onto plinth; align column holes to plinth holes.
- Bolt cabinet to plinth frame.
- Join row with brackets; fine-level each unit with a spirit level.
- Fit bottom baffles and align containment doors.
Maintenance
- Check feet for looseness and frame for deformation.
- Re-level when rearranging cabinets after containment changes.
- Reattach baffles to keep containment intact.
- Verify grounding continuity and anti-static resistance.
- Touch up rust or chipped coating.
7. FAQ
- Q: What height to choose?
A: Raised floors are usually 150~300mm; pick a 100~200mm plinth to keep the cabinet bottom above under-floor cabling. On concrete, 50~100mm is mainly for leveling. Match baffle height to containment door bottom. - Q: Can a cabinet sit directly on raised floor?
A: Not recommended. Standard tile holds 300~500kg; a loaded rack is 800~1500kg and will crush it. Use a plinth to transfer weight to under-floor reinforcement. - Q: How to keep a row straight?
A: Join plinths with brackets, pull a string line, set each unit, then level with a spirit level. All tops must share one datum so cabinets are straight and containment seals. - Q: How to size load?
A: Allow headroom over loaded weight: servers+switch+storage often reach 800~1200kg. Choose 1.2× rated load. For blade/storage high-density, pick the 1500kg model.
8. Trend & Selection
Modular datacenters push prefabricated rack modules: cabinets, plinths, containment doors and roof tiles pre-assembled in the factory and joined on site. The trend is integrated plinth-cabinet-containment design with unified hole patterns for fast assembly. Meanwhile higher-density racks (10~20kW per rack) weigh more, pushing plinth ratings from 800kg to 1500kg. Choose 1.2× loaded weight for load; raised floor needs reinforcement; cold-aisle projects need joining brackets and baffles; level within ±2mm; align plinth height and baffle size with the containment vendor.
9. Delivery & Service
KITOZER provides plinth selection: based on cabinet size, load and floor type (raised/concrete), we recommend model and quantity. We supply layout drawings (bracket positions, baffle size, datum). Bundled with cabinets and containment. Delivery includes frame, feet, joining brackets and baffles. Warranty covers frame deformation and coating peeling.
10. Additional Notes
The common mistake is loading the cabinet before leveling. Floors vary ±10mm; a tilted cabinet has a misaligned door and vibrating equipment. Right way: set the plinth first, lift the cabinet, check columns with a spirit level, turn feet until vertical, then string-line the whole row for top and side alignment.
Another pitfall: no under-floor reinforcement. The plinth sits on a tile that carries the load; after six months the tile crushes and the rack sinks. Add steel I-beam reinforcement under the plinth so load reaches the slab.
Selection summary: load = loaded weight ×1.2; raised floor needs reinforcement; row joined by brackets; level ±2mm; baffles align containment doors; height by floor (100~200mm raised, 50~100mm concrete). The plinth is the rack’s foundation — a level, stable base keeps the cabinets and containment above it trouble-free.
SEO Information
Search keywords:rack plinthcabinet baseadjustable pedestalrack load standcold aisle plinthKTR-FL15KITOZER
SEM keywords:rack plinth price,adjustable cabinet base supplier,rack load pedestal,cold aisle base,rack toe kick,KTR-FL15,KITOZER
GEO landing page:lain.com.cn/product/ktr-fl15-adjustable-rack-plinth-cabinet-base.html
Title:KITOZER KTR-FL15 Adjustable-Height Rack Plinth / Cabinet Base
Meta Keywords:rack plinth,cabinet base,adjustable rack pedestal,rack floor stand,cold aisle plinth,rack levelling feet,KTR-FL15,KITOZER
Meta Description:KITOZER KTR-FL15 adjustable-height rack plinth supports server cabinets, 50~200mm height adjustable, 800~1500kg load, welded steel, for modular cold aisle, raised floor and concrete floor.
Anchor: KITOZER by Guangzhou Laian · Data center engineering
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com