KITOZER
KITOZER

KITOZER sliding pull out shelf

KITOZER KTR-SH11 Sliding Pull-out Rack Shelf for 19″ Server Racks

Brand: KITOZER Series: KTR-SH11 Category: Modular Cold Aisle / Rack Accessory

Sliding pull-outCold-rolled steel50kg load19″ standardKTR-SH11

KITOZER KTR-SH11 Sliding Pull-out Rack Shelf

1. Overview

KITOZER KTR-SH11 is a sliding pull-out rack shelf (tray / shelf) installed inside 19″ server and network racks to support equipment without rack ears: desktop switches, routers, fiber terminal boxes, KVM switches, monitors, laptop benches and battery boxes. Some rack devices have ears and bolt directly; others sit on a shelf. The shelf is the rack’s shelf board, and the pull-out design lets you slide the whole device out for service instead of reaching into the rack.

KTR-SH11 is bent from cold-rolled steel sheet with a gray electrostatic powder coat. Ball-bearing rails on both sides let the tray slide out of the rack while still supporting 50kg. Depths are 600mm or 800mm to match rack depth; width is 19″ standard, fixed by M6 cage nuts on square-hole rails. Choose vented (for airflow) or solid (for dust sealing). Pull-out travel is about 350mm, with a stop to prevent falling out, and a latch for full removal.

Used in datacenter server racks, network racks and enclosed cold-aisle racks. Typical layout top-down: 1U cable manager, 2U switch shelf, 3U router tray, 4U fiber box shelf, then rack-mounted servers. Pull-out shelves suit service-heavy spots like KVM consoles and laptop temporary access. In a closed cold aisle, vented shelves let cold air pass; solid shelves isolate dust.

2. Key Features

Sliding pull-out

  • Ball-bearing rails, smooth travel.
  • ~350mm pull-out.
  • Stop prevents falling.
  • Latch for full removal.

Cold-rolled steel

  • Cold-rolled steel bend.
  • Electrostatic powder coat.
  • 50kg load (extended).
  • Static-load tested.

19″ standard

  • 19″ standard width.
  • M6 cage-nut fixing.
  • 600/800mm depth options.
  • Fits mainstream racks.

Vented/solid options

  • Vented supports airflow.
  • Solid seals dust.
  • Safe rounded edges.
  • Device fixing holes.

3. Specifications

Item KTR-SH11-600 KTR-SH11-800
Rack depth 600mm 800mm
Shelf depth 550mm 750mm
Usable width 450mm 450mm
Load (extended) 50kg 50kg
Pull-out travel 350mm 350mm
Sheet thickness 1.5mm steel 1.5mm steel
Finish Powder coat gray Powder coat gray
Vented Optional Optional
U height 1U 1U

4. Reference Prices

KTR-SH11-600 sliding shelf (600 rack, vented, 50kg): Reference USD 42~83 / pc (ref. CNY 300~600 at ~7.2)

KTR-SH11-800 deep shelf (800 rack, solid/vented): Reference USD 53~104 / pc (ref. CNY 380~750 at ~7.2)

Reference only; price varies by depth, vented/solid and quantity. Rack, cage nuts and screw kits billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Desktop switch/router support.
  • Fiber terminal box / ODF tray.
  • KVM switch / console pull-out.
  • Laptop temporary bench.
  • Cold-aisle rack equipment shelf.

6. Installation & Maintenance

Installation

  • Pick the U position; front ears on square-hole rails.
  • Fix front ears with M6 cage nuts.
  • Push in; rear ears contact rear posts.
  • Level and tighten all screws.
  • Slide out to test rails.
  • Secure equipment with screws through shelf holes.

Maintenance

  • Tighten screws quarterly.
  • Lubricate rails semi-annually.
  • Do not exceed 50kg.
  • Do not step on extended shelf.
  • Touch up chipped paint.

7. FAQ

  • Q: Fixed or sliding shelf?
    A: Fixed is cheap and rigid — use for devices that never move (fiber box, patch panel). Sliding is for service-heavy gear (KVM, laptop, router).
  • Q: How to choose depth?
    A: Match rack depth: 600 rack → 550 shelf; 800 rack → 750 shelf. A shallow shelf in a deep rack leaves a gap; a deep shelf won’t fit a shallow rack.
  • Q: Vented or solid?
    A: In cold-aisle racks where supply air passes through, choose vented; choose solid for dust isolation or sealing. Don’t cover a vented shelf with a full cloth.
  • Q: How much load?
    A: Rated 50kg extended; higher when pushed in. Don’t overload long-term — rails and ears will deform.

8. Trend & Selection

Rack accessories are going modular and tool-less: shelves, managers and PDUs snap in without screws. Trends are larger vented areas for cold-aisle airflow, damped soft-close rails, and shelves with integrated cable holes and PDU hooks. Choose SH11-600 for 600 racks and SH11-800 for 800; sliding for service positions, fixed for stationary gear; vented inside cold aisles; leave load margin; buy same-brand same-batch to match square rails.

9. Delivery & Service

KITOZER supplies rack accessories: based on rack depth, equipment list and load, we recommend shelf count and type. Bundled with server racks, network racks and cold-aisle enclosures. Delivery includes shelf, rails, M6 cage nuts/screws and manual. Warranty covers rail replacement.

10. Additional Notes

The most common shelf problem is fixing only the front ears while rear ears hang free. Eager installers bolt only the front, leaving a cantilever that sags under load. Fix both front and rear ears; rear ears must sit flush on rear square rails.

Another pitfall: forcing dusty rails. Site dust makes rails stiff, and yanking them grinds the ball bearings. Wipe rails before install, oil semi-annually, and don’t pile loose tools on the shelf.

Selection summary: SH11-600 for 600 racks, SH11-800 for 800; sliding for service, fixed for stationary; vented in cold aisles; fix both ears; keep ≤50kg. The shelf is small but it is the rack’s shelf board — a steady shelf keeps equipment safe.

SEO Information

Search keywords:rack shelfsliding trayserver rack shelfpull-out shelfrack trayKTR-SH11KITOZER

SEM keywords:rack shelf price,sliding rack shelf supplier,server rack tray,19″ pull-out shelf,cold aisle accessory,KTR-SH11,KITOZER

GEO landing page:lain.com.cn/product/ktr-sh11-sliding-rack-shelf-ventilated.html

Title:KITOZER KTR-SH11 Sliding Pull-out Rack Shelf for 19″ Server Racks

Meta Keywords:sliding rack shelf,pull-out shelf,server rack tray,sliding rack tray,cold aisle shelf,datacenter rack accessory,KTR-SH11,KITOZER

Meta Description:KITOZER KTR-SH11 sliding pull-out rack shelf, cold-steel 50kg load, 19″ standard mount, for server/network rack equipment support.

Anchor: KITOZER by Guangzhou Laian · Data center engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart