Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER
, , ,

Data Center Load-bearing Reinforcement Equipment | KITOZER

By adding steel beams and laying load-bearing plates, the load-bearing capacity of the computer room floor is enhanced to meet the needs of high-density equipment deployment.

Computer Room Load-Bearing System

The load-bearing support frame in a computer room is typically reinforced with steel beams, depending on the equipment location. For example, channel steel or angle steel is used, supported by load-bearing structural beams (walls) at both ends. For instance, adding angle steel or channel steel beams close to the ground at the machine row location. Required load-bearing capacity is confirmed after a site structural survey.

KITOZER data center load-bearing reinforcement equipment

No. Equipment/Measure Function Deployment Location Mandatory Remarks
1 Electronic Access Control Secures major entrances (including server rooms and critical zones)

1. Server room entrance


2. Critical server area entrance

Yes
2 Intrusion Alarm & Video Surveillance Anti-theft and intrusion alerting Server room windows, entrances, etc. Yes Can be supplemented by monitoring
3 Surge Protective Device (SPD) Induction lightning protection Distribution box Yes
4 Automatic Fire Suppression System Automated fire detection, alarm, and extinguishing Can consist of manual extinguishers + alarms
5 Fresh Air Ventilation Waterproofing and moisture control
6 Environmental Monitoring (Water Sensors) Water leak/sensitivity detection Can be performed by manual inspection
7 Precision Air Conditioning (CRAC) Temp/Humidity control; moisture prevention Yes Compatible CRAC models are confirmed per project.
8 Grounding System Lightning protection grounding Yes
9 UPS System Uninterruptible Power Supply (UPS) Yes Compatible UPS models are confirmed per project.
Brand

KITOZER

Product Type

Load-bearing reinforcement

Application

Data centers

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shopping Cart