KITOZER EMC Shielded Chamber 7x4m — 100dB Welded Steel Room Price

How to Build an EMC Shielded Chamber? Complete Technical Guide

EMC testing requires an electromagnetically quiet environment. KITOZER EMC shielded chamber is a welded steel enclosure, 7m×4m×3m, shielding effectiveness ≥100dB from 10kHz to 1GHz, covering radiated emissions, radiated immunity, and conducted disturbance testing. This article breaks down every subsystem: shell, filters, waveguide, shielded door, HVAC, fire suppression, monitoring, and acceptance.

KITOZER EMC shielded chamber welded steel room 100dB shielding effectiveness radiated emission test
KITOZER 7m×4m×3m EMC shielded chamber interior

1. Why EMC Testing Needs a Shielded Chamber?

Every electronic device radiates electromagnetic noise while operating, and is also susceptible to external interference. EMC testing measures whether a device’s emissions exceed limits and whether it can function under external interference. But if the test environment itself is full of noise (mobile, WiFi, broadcast, industrial interference), the data is meaningless.

A shielded chamber blocks external interference and contains internal test signals, creating an “electromagnetically quiet” space. GB/T 17626 and CISPR 16 require shielding effectiveness ≥100dB from 10kHz to 1GHz — attenuating external signals by over 100,000×.

2. Shielding Principle

A continuous conductive metal enclosure reflects, absorbs, and multi-reflects electromagnetic energy. To achieve 100dB, every detail matters — even a 1mm gap can drop SE by 20dB. SE = 20log(E₀/E₁); 100dB means only 1/100,000 of external field penetrates.

3. Shielded Shell Structure

KITOZER uses welded steel construction (not bolted gasketed). Welded chambers offer higher SE, long-term stability, and no gasket aging issues — ideal for precision EMC labs.

3.1 Dimensions

Internal clear size: 7m(L)×4m(W)×3m(H), floor area 28㎡, volume 84m³. Fits: 3m/10m antenna mast, EUT test table, 8 equipment racks, precision AC, operator walkway.

3.2 Floor Shielding

  • Insulation mat (ID-10): 10mm rubber, prevents accidental bonding to building rebar. 28㎡, $933.
  • Floor steel frame (LG-80-60): 80×60mm square tube grid at 600mm spacing. 28㎡, $933.
  • Floor steel plate (SP-5): 5mm galvanized steel, fully welded. 28㎡, $2,956.

3.3 Wall Shielding

Wall area = perimeter×height = (7+4)×2×3 = 66㎡:

  • Wall frame (LG-40-60): 40×60mm vertical at 600mm. 66㎡, $1,833.
  • Wall plate (SP-2): 2mm galvanized steel. 66㎡, $5,133.

3.4 Ceiling Shielding

  • Ceiling frame: 40×60mm. 28㎡, $778.
  • Ceiling plate (SP-2): 2mm steel. 28㎡, $933.

3.5 Welding & Rust Protection

All joints CO₂ gas-shielded full penetration weld, weld height ≥0.7× plate thickness. Total area 122㎡. Rust paint $2,304. Welding labor & consumables $8,472.

4. Power & Signal Penetration: Filters & Waveguide

Every cable passing through the shell becomes an antenna. All penetrations must use filters or waveguide tubes.

4.1 Mains Power Filter (PF-380-100)

380V/100A 3-phase, suppresses both common-mode and differential-mode. Insertion loss: ≥100dB @10kHz, ≥60dB @1GHz. $833.

4.2 Fiber Waveguide Tubes (WG-01)

4 pcs, lets fiber pass but blocks EM waves. $889.

4.3 Network Filter (NF-01)

Gigabit Ethernet filter. $417.

4.4 Signal Filter (SF-01)

For monitoring sensor signals. $278.

4.5 AC Power/Signal Filter (ACF-01)

For precision air conditioner. $556.

4.6 AC Drainage Waveguide (AWG-01)

Condensate pipe penetration. $139.

4.7 Supply/Exhaust Waveguide Vent (WG-300)

HoneycombCutoff Waveguide, 300×300 or 600×600mm. Supply and exhaust each $278.

4.8 Other Filters

  • Logic ground filter (GEF-16-35): $417
  • Access control signal filter (ACSF-01): $278
  • Fire alarm signal filter (FSF-485): $278

5. Shielded Door System

The door is the weakest point. KITOZER manual/motorized shielded door (SD-900), 900×2000mm:

  • Welded steel door with spring-loaded beryllium-copper finger gaskets
  • Double-layer finger gaskets, contact pressure ≥3N/cm
  • Multi-point rotary locking for uniform compression
  • Electromagnetic lock + exit button, auto-unlock on fire alarm
  • EXW price: $7,778

6. Power Distribution & Lighting

  • Mains distribution box (PDB-01) with SPD: $417
  • 600×600mm LED panel lights ×4: $333
  • Rack/wall sockets ×8: $333

7. Interior Finishing

  • Aluminum ceiling tiles (AK-600) ×78: $867
  • Wall color steel panels (CGB-12) ×37: $1,542
  • ESL raised floor (ESD-600) ×78: $1,733
  • Equipment force brackets ×11: $611

8. FK-5-1-12 Gas Fire Suppression

  • FK-5-1-12 cylinders (FM-40L) ×3: $2,483
  • Agent 58.8kg: $3,267
  • Smoke/heat detectors: $56
  • Release indicator/alarm bell/sounder: $83
  • Fire control panel: $278

9. Precision Air Conditioning

2 units (AC-PREC), 12kW each, $13,889 total:

  • Down-supply/up-return, matches raised floor
  • Temp 23±1°C, humidity 45~55%
  • AC power must pass through filter

10. Equipment Racks

8 server racks (RACK-01) for test receivers, signal generators, spectrum analyzers. $3,333.

11. Environment Monitoring System

  • Temp/humidity sensor: $56
  • IP camera: $83

  • Smoke/leak detection: $167
  • Power meter/UPS/AC monitoring: $583
  • Access control/IR detector: $333
  • Monitoring host + touchscreen: $833
  • Platform software: $1,389
  • 12. Network Cabling

    • Open cable tray 15m: $208
    • 12-core fiber ×8 sets: $1,111
    • Cat6 12 cables/set ×8: $667

    13. Fresh Air & Smoke Exhaust

    • Heat recovery ventilator (HRV-01): $833
    • Supply/return vents + louvers: $83
    • Duct 20m + control box: $417
    • Relief valve: $56
    • Smoke exhaust fan: $278

    14. Floor Load Reinforcement

    • Rack force brackets ×8: $444
    • AC force brackets ×2: $111
    • PDU force bracket ×1: $56

    15. Price Summary (EXW, reference, doubled)

    System Main Contents EXW Price (USD)
    Shielded shell Floor/wall/ceiling plates + frames + welding $24,320
    Filters & waveguide Power/network/signal filters + vents $4,611
    Shielded door 900×2000mm manual/motorized + access control $15,556
    Power & lighting Distribution box + lights + sockets $2,233
    Interior finishing Al ceiling + color steel + ESD floor $10,117
    Gas fire suppression FK-5-1-12 ×3 + alarm control $12,511
    Precision AC 2 units 12kW $28,333
    Racks 8×42U $6,667
    Monitoring Sensors + host + software $5,667
    Cabling Tray + fiber + Cat6 $3,972
    Fresh air & exhaust HRV + smoke exhaust $3,889
    Floor reinforcement Force brackets $1,222
    Project EXW total (reference, doubled) $296,284

    16. Construction Sequence

    1. Site survey: dimensions, floor load, cable routing
    2. Base prep: insulation mat, steel frame
    3. Shell welding: floor → walls → ceiling, segment by segment
    4. Filter/waveguide installation
    5. Shielded door installation, finger gasket pressure test
    6. Rust protection on all welds
    7. Interior: ESD floor, aluminum ceiling, color steel walls
    8. Equipment: AC, racks, fire suppression, monitoring, PDU
    9. Cabling: tray, fiber, Cat6
    10. System commissioning: AC temp/humidity, fire linkage, monitoring alarms
    11. SE testing: signal source + receive antenna, 10kHz~1GHz point by point

    17. Acceptance Criteria

    • Shielding effectiveness: ≥100dB 10kHz~1GHz per GB/T 12190
    • Temperature: 23±1°C
    • Humidity: 45~55%
    • Fire: simulated alarm, gas release, door auto-unlock
    • Monitoring: temp/humidity, smoke, leak, door alerts all pushed

    18. FAQ

    Q: Welded vs bolted chamber?
    A: Welded gives ≥100dB for EMC testing. Bolted gasketed gives 60~80dB, suitable for server room radiation shielding but not EMC testing.

    Q: Can I use WiFi inside?
    A: No. WiFi and mobile signals are blocked. Data must go through fiber waveguide.

    Q: Why waveguide vents for AC?
    A: A plain duct is an EM leakage path. Honeycomb waveguide vents let air through but block RF.


    SEO keywords: EMC shielded chamber, electromagnetic compatibility, shielded room construction, welded steel shielded room, 100dB shielding effectiveness, radiated emission test, KITOZER

    SEM keywords: EMC test chamber, EMC laboratory, shielded room cost, shielded door, power filter, waveguide vent

    GEO keywords: KITOZER shielded chamber factory Guangzhou, EMC lab construction, shielded room installation, welded steel chamber

    Tags: primary=EMC shielded chamber; long-tail=7m×4m EMC chamber price; industry=EMC testing; brand=KITOZER; source=Guangzhou Lian technical documentation