Micro-Modular Cold Aisle
I. Overview of Micro-Modular Data Centers
Micro-modular data centers are designed to address changes in servers due to cloud computing, virtualization, centralization, and high density, improving data center operational efficiency, reducing energy consumption, and enabling rapid expansion without mutual interference. A micro-modular data center consists of multiple micro-modules with independent functions and unified input/output interfaces. Micro-modules in different areas can back each other up, and a complete data center is formed through the arrangement and combination of related micro-modules. A micro-modular data center is an integrated, standardized, intelligent, highly adaptable infrastructure environment and a highly available computing environment.

II. Composition of a Micro-Modular Data Center
A modular data center mainly consists of server racks, enclosed aisles, power supply and distribution systems, cooling systems, intelligent monitoring systems, structured cabling, and fire protection systems. A single modular data center is configured with N server racks (including server racks, network racks, and structured cabling cabinets). This module (excluding UPS) occupies an area of ​​35m². Including the external maintenance aisle and the PDF cabinet supplying power to the internal air conditioning, the total footprint does not exceed 55m², and the total module height does not exceed 2.65m. The number of racks can be reduced or increased in pairs according to customer needs.

1. Cabinets and Enclosed Aisles
(I) Cabinets
Cabinets can be divided into three categories according to function: IT equipment cabinets, electrical equipment cabinets, and structured cabling cabinets. All three types of cabinets adopt the same structural design, with unified cabinet architecture, appearance, and dimensions. They employ an airflow organization design with a front enclosed cold aisle and a rear enclosed hot aisle. The enclosed cold/hot aisle scheme uses a 200mm+1000mm+200mm deep cabinet design, integrating equipment installation space and enclosed aisles. The enclosed cold aisle cabinet is equipped with a front tempered glass door and a rear sheet metal sealed door.
(1) Cabinet System Principle
Two fan units are configured at the top of one end of the cold compartment, and one air-entry enclosed panel is configured on each side. These movable end enclosed panels are quick-release and easy to maintain, and are equipped with movable inner panels. They use an electromagnetic detachment method; under normal conditions, they are electromagnetically engaged, and the entire module is in a sealed state. The top of the cabinet’s hot compartment is equipped with two emergency exhaust hot air blower units, and a set of micro-module emergency electromagnetic opening unit flaps is installed in conjunction with the blower units to enable the entry of extinguishing gas. The magnetic lock voltage is DC12V.
(2) Cabinet Features
1) Modular closed cold/hot compartment integrated design
2) Single tempered glass door at the front and sheet metal sealed door at the rear
3) The sealed compartment provides emergency status display and emergency ventilation functions, immediately handling accidents and issuing alarms
4) The cabinet is compatible with both top and bottom cabling schemes
5) The installation square hole strip has adjustable front and rear positions
6) Includes a 15.5-inch monitoring touch screen
7) The micro-module cold compartment is extended and installed at the front of the GMA cabinet, expanding the integrated cold and hot aisle cabinet. It is installed by connecting with the cabinet mounting holes. The front door of this product is a tempered glass panel, fully sealed design, and equipped with a handle lock.
8) The top of the cabinet’s hot compartment is equipped with an emergency exhaust hot air blower unit to handle different emergencies. 9) The extended cold compartment (front end of the rack) is equipped with two fan units, and each side has an air intake sealing panel. These are movable end sealing panels that can be quickly installed and removed for easy maintenance. They have a movable inner layer panel; under normal conditions, they are electromagnetically engaged, and under abnormal conditions, they disengage electromagnetically.
10) LED lighting is installed inside the top of the rack door. The lights illuminate when the door is opened and close when the door is closed. The illuminance is 200 lumens, providing internal lighting. The voltage is 12V, and the system is powered by the control box.
11) An LED (blue and red) dual-color ambient lighting system is installed inside the rack door frame, providing 200 lumens of illuminance. It features dual-color LED strips installed around the door, pre-installed at the factory, and operates on 12V. The normal operating light is blue, and the alarm light is red.
12) Each rack’s hot compartment end is equipped with a micro-module emergency electromagnetic opening unit flap, linked to the fire suppression system, allowing fire extinguishing gas to enter. The magnetic lock operates on DC 12V.
(II) Sealed Passageway The sealed passageway mainly consists of end doors, skylights, sealing plates, and other installation accessories.
(1) Material Requirements All components of the sealed passageway system (except for the skylight) are made of high-quality cold-rolled steel plates. The thickness of all materials used in load-bearing components (keel, support frame, etc.) is 1.2–1.5 mm. The door frame assembly has cable concealment and routing functions. The lintel is equipped with a high-definition LED screen and status lights, welcome lights, and alarm display functions. The skylight uses 5 mm thick tempered glass with high light transmittance, increasing glass strength and reducing the impact of glass fragmentation on the data center and maintenance personnel.
1) The signal cables and power cables used are insulated with flame-retardant and fire-resistant materials. The color of the cable and busbar insulation layer or outer sheath meets relevant requirements. 2) All materials used in all parts are compatible, and the non-metallic structural components are flame-retardant. Their combustion performance meets the following requirements: flame height 20mm ± 2mm, two flame applications, each lasting 30 seconds with a 10-minute interval, and a flaming time of no more than 10 seconds after each application.
(2) Functional Requirements of the Sealed Passage System
If the system is equipped with temperature and humidity monitoring, it can display the real-time passage status. When the internal environment of the passage exceeds the preset threshold, the movable skylight of the sealed system automatically opens, simultaneously activating the audible and visual alarm and notifying on-site personnel. In case of fire or other emergencies inside the passage, it can be controlled by the fire control center and automatically open, ensuring a sufficiently large area for rapid injection of fire-fighting gas. Simultaneously, the audible and visual alarm is activated, and on-site personnel are notified through the central control unit.
The sealed system meets the requirements for airflow containment, completely isolating hot and cold air. The first and last doors are normally sealed, and the skylight frame and other sealed components have no obvious gaps. The frame has cable management capabilities, and all cables laid in the sealed system are not exposed. The passageway control system is used to control the monitoring, linkage, and power supply of all monitoring equipment within the passageway, enabling free switching of various alarm logics and processing mechanisms.
All skylights should be designed for tool-free quick installation or removal, facilitating daily maintenance and replacement.
The enclosed passageway system is designed with both hot and cold light source illumination, with each source providing 300 lumens or more, facilitating equipment mounting and routine maintenance. Status displays are installed at both ends of the passageway, including operating status, fire alarm, maintenance status, and other function displays.
2. Power Supply and Distribution System The modular data center features two power distribution schemes: 380V/50Hz and 480V/60Hz industrial voltage. The power supply and distribution system includes UPS, PDF, and PDU. The power supply and distribution system includes a rack-mounted integrated management unit (responsible for high-voltage, low-voltage, and comprehensive management systems), UPS input/output power distribution, providing maintenance bypass and extended output interfaces, air conditioning power distribution, and comprehensive management power distribution. The UPS system consists of a rectifier PFC, inverter, battery charger, DC/DC converter, battery, transfer switch, etc., and has three operating modes: mains mode, battery mode, and bypass mode. When the mains power is abnormal or interrupted and cannot supply power normally, the battery, as a backup energy storage system, provides a continuous and stable AC power supply to the load through the UPS after inversion.
3. Cooling System
The modular data center uses row-level horizontal air conditioning for cooling.
(1) In the modular data center, the air conditioner and the equipment cabinet together form a closed cold (hot) aisle to achieve isolation between hot and cold air. The air conditioner used in the modular data center is a horizontal air supply system with a back-in, front-out airflow path. It draws in the hot air exhausted from the server, cools it, and then blows it out; the cold air is then drawn in and exhausted by the server, and so on. (2) Horizontal air conditioning units are located close to the heat source, significantly shortening the air supply distance and reducing pressure loss and cold air leakage, thus improving the efficiency of cooling capacity utilization.
(3) Standard modular data center modules are used in spaces smaller than 300m², with both cold and hot aisles having a width of 1.2m.
(4) The indoor units of the air conditioner have interfaces for refrigerant piping, power and signal lines, and condensate drain pipes at the top or bottom.
4. Intelligent Monitoring System
The monitoring system primarily targets the various components of the modular data center infrastructure layer, such as power distribution, cooling, security, and environmental systems, providing real-time monitoring of the operating status of each component and equipment within these systems.

5. Structured Cabling
Modular data centers install cable trays at the top for organized cable management. These trays are divided into signal cable trays and power cable trays, used for signal and power cables respectively. Each server rack has a cable routing hole in the center of the top for easy cable connection. The cable trays can be expanded in length and, where they intersect, separate into upper and lower channels for hierarchical management of power and signal cables. Cable bundling holes are located at the junction of the ceiling openings for easy cable bundling.

Power cables are routed using metal conduits. Indoor lighting circuits are separated from power circuits; indoor lighting power lines run within the suspended ceiling, while equipment power lines run under the raised floor. Metal conduits are used, with the conduit walls grounded. Junction boxes should be installed at conduit intersections, branches, and connections between conduits of different diameters, and these junction boxes should be waterproofed and moisture-proofed. Exposed portions of equipment power lines above the raised floor are secured with flame-retardant materials to ensure wiring safety. Ceiling lighting power lines are laid in metal cable trays or conduits in the ceiling.
Control cables are routed indoors either within the suspended ceiling or under the floor, depending on specific needs, and appropriate protective measures are implemented. Exposed portions above the floor are secured with flame-retardant materials to ensure wiring safety.
Data and signal cables are routed indoors under the raised floor. All cabling points are clearly labeled, and network cable management and installation testing are performed. Patch cord organizers are installed in server racks, and network equipment is registered. All cabling within the server room and between server racks should consider current and future network connectivity, avoiding redundant patching and temporary wiring between equipment and racks.
Each data equipment rack in the computer room is equipped with a 24-port Category 6 patch panel, and each rack has Category 6 unshielded cables connected to the Category 6 patch panels in the network racks.
All cable trays are grounded. Enclosed galvanized metal cable trays are used for high-voltage power cables and are laid under the raised floor. All cable trays should be rust-proof and corrosion-resistant.
6. Fire Protection System
The fire protection system includes an automatic fire alarm system and a gas extinguishing system. A pollution-free gas extinguishing system is used throughout the computer room; the extinguishing medium is heptafluoropropane. All equipment and materials used in the fire protection project are high-quality products manufactured by reputable companies, certified as qualified by nationally designated testing centers, and approved for use by fire authorities. This project uses a heptafluoropropane pipeline gas extinguishing system.
(1) Fire Protection System Principle
When a fire occurs, after the smoke detector alarms, the fire controller issues a fire alarm warning sound and light alarm signal. However, the extinguishing procedure is not initiated at this time. When the heat detector and smoke detector in the same protected area alarm simultaneously, the controller issues an audible and visual alarm signal. Before manually or automatically activating the fire suppression system, the main control console issues an instruction to notify personnel to evacuate and sends a linkage control signal to automatically cut off the power supply to the computer room distribution cabinet, i.e., cutting off the power supply to non-fire-fighting equipment, such as air conditioners, fresh air units, and lighting equipment. The linkage process between the power supply to these devices and the fire suppression system is achieved by using the shunt trip of the main circuit breaker in the power distribution cabinet as a remote terminal. The main switches in the distribution cabinet are equipped with shunt trip devices and auxiliary contacts. Additionally, the emergency trip button can manually cut off the incoming power supply when necessary. The power supply for the fire suppression facilities in the computer room is provided by a UPS.
(2) Requirements for the Fire Suppression System
1) The selected extinguishing medium is heptafluoropropane clean gas.
2) The system’s fire suppression method is total flooding.
3) The gas extinguishing system is equipped with pressure relief and smoke extraction functions.
4) The fire suppression system has linkage functions with power supply and distribution, access control, site monitoring, and cold aisle systems. III. Enclosed Cold Aisle Section
(I) Server Rack Section
1. Server Racks
The modular data center can be configured with N server racks, including server racks, network racks, and structured cabling racks.
2. Server Rack Appearance
The server racks in the modular data center are of uniform size and use front and rear airflow. The appearance of the server racks is shown in the figure.

3. Rack Features
(1) High ventilation rate at the front and rear doors.
(2) Two vertically mounted PDUs can be installed at the rear of the rack.
(3) The exact position of each “U” is marked on the vertical mounting columns of the rack. The front door, rear door, and side panels of the rack are all lockable and can only be opened with the provided key.
4. Rack List
â‘ Vertical Cable Management System
â‘¡ Double Doors
â‘¢ Lockable Side Panels
â‘£ Frame Columns
⑤ Adjustable Leveling Feet
â‘¥ Accessories
⑦ Casters
â‘§ Reversible Curved Doors
⑨ Keys
â‘© Vertical Mounting Flanges

(II) Enclosed Corridor The enclosed corridor of a modular data center mainly consists of end doors and skylights.
End Doors
(1) End doors for enclosed corridors are available in two options: sliding doors and double doors, which can be selected according to customer needs.
(2) Sliding door dimensions: Height × Width × Depth = 2050mm × 1200mm × 42mm.
The sliding door adopts a sliding structure, using the server rack as a carrier, with upper and lower tracks installed, ensuring the independence of the enclosed corridor system. The door panel is made of 1.5mm cold-rolled steel plate bent into shape, with tempered glass installed in the middle to ensure visibility within the corridor area.
Sliding door appearance diagram

(3) Double door dimensions: Height × Width × Depth = 2050mm × 1200mm × 42mm.
The double door is connected to the cabinet with screws, ensuring system independence. Tempered glass is inlaid in the middle of the door panel, and the tempered glass effectively meets fire emergency requirements. Sealing brushes are installed at the bottom of the door panel to improve module airtightness. The appearance of the double door is shown in the figure.
(4) Schematic diagram of the double door appearance.

2. Skylight
(1) The enclosed passage adopts a flat-top structure.
(2) Flat-top skylight dimensions: Height × Width × Depth = 350mm × 1200mm × 600mm.
(3) The flat-top skylight consists of side panels, a top panel, and a rotating skylight, with each cabinet serving as an expansion module unit. The rotating skylight is connected to the top panel by pins. In operation, the skylight is horizontal; in fire-fighting mode, it melts and automatically opens under gravity, allowing fire extinguishing gas to enter the passage. The appearance of the flat-top skylight is shown in the figure.
(4) Schematic diagram of the flat-top skylight

3. Power Supply and Distribution System
The modular data center has two power distribution schemes: 380V/50Hz and 480V/60Hz industrial voltage. The power supply and distribution system includes UPS (Uninterrupted Power Supply), PDF (Power Distribution Frame), and PDU (Power Distribution Unit).
(1) Overview
External power to the modular data center is output to the PDF via the UPS. The PDF outputs three-phase power to the PDUs in each rack, and the PDUs output power to the equipment inside the racks.
(2) UPS
1) The UPS provides uninterrupted power supply to the modular data center. In the event of an emergency power outage from the mains/generator, power is supplied by batteries, which can meet the application scenario of a single server rack power of 9kW.
2) 380V Voltage: The modular data center is equipped with a 360kVA modular UPS, consisting of three 120kVA UPS units. It can be flexibly configured within the capacity range of 20kVA to 360kVA to meet the needs of a single server rack of 3kW, 6kW, and 9kW.
3) 480V voltage standard: The modular data center is equipped with a 400kVA modular UPS, which consists of two 200kVA UPS units. It can be flexibly configured within the capacity range of 125kVA to 400kVA to meet the needs of a single server rack of 3kW, 6kW, and 9kW.

4. PDF Distribution Cabinet Each circuit in the PDF cabinet is equipped with a power tester to measure parameters of the input three-phase AC power (voltage, current, frequency, power, power factor, etc.), and uploads the data to the monitoring system via an RS485 interface. The PDF’s output circuit breakers are configured for 14 server racks per row, supporting a smooth increase in server power up to 9kW.
5. Row-to-Row Precision Air Conditioning
Modular data centers employ row-level horizontal air conditioning for cooling.
(1) Within a modular data center, the air conditioner, along with the equipment cabinets, forms a sealed cold (hot) aisle, achieving isolation between hot and cold air. The air conditioner used in the modular data center employs a horizontal airflow method, with the airflow path being rear-in, front-out. It draws in the hot air exhausted from the servers, cools it, and then blows it out; the cold air is then drawn in and exhausted by the servers, repeating this process.
(2) The horizontal air conditioning system is located close to the heat source, significantly shortening the airflow distance, thereby reducing pressure loss along the airflow path and the leakage of cold air, improving the utilization efficiency of cooling capacity.
(3) Standard modular data center modules are used in spaces under 300m², supporting a power density of up to 9kW per cabinet, with both cold and hot aisle widths of 1.2m.
(4) The indoor unit of the air conditioner has interfaces for refrigerant piping, power and signal lines, and condensate drain pipes at the top or bottom. The appearance of the indoor unit is shown in the figure (the actual appearance depends on the configuration). IV. Classification of Micro-Modular Data Centers Micro-modular data centers are mainly divided into partially prefabricated data centers and fully prefabricated data centers.
1. Partially Prefabricated Data Centers A partially prefabricated data center is a data center composed of prefabricated micro-modules (rack systems, cooling systems, cabling systems, monitoring systems, etc.) and traditional “on-site construction” systems.
2. Fully Prefabricated Data Centers A fully prefabricated data center consists of prefabricated micro-modules (power supply systems, rack systems, cooling systems, cabling systems, monitoring systems, etc.) forming a single, independent, enclosed space. The modules are delivered to the site in several parts and then reassembled. External supporting infrastructure is required, such as generators or chillers, and high and low voltage power distribution.
V. Functional Characteristics of Micro-Modular Data Centers
(1) Comprehensive Functions A micro-modular data center integrates a load-bearing and channel enclosure system, an uninterruptible power supply system, a power distribution system, an environmental management system, a security management system, a monitoring management system, and lighting within a single rack or micro-module. With a visualization system, a single rack or micro-module constitutes a fully functional data center.
(2) Easy to build: Adopting a fully enclosed design, the entire process of procurement, installation, construction, and commissioning can be completed within days without the need for a separate server room. This changes the traditional data center construction method, which requires design, decoration, equipment selection, and coordination of equipment delivery and installation. Building a data center with BR saves time, effort, and money.
(3) Convenient expansion: When your business grows and the existing racks are insufficient, simply add more racks to complete the expansion. If two or more racks are placed side-by-side, a dedicated rack assembly component can be selected to connect the cold aisles and hot aisles of multiple racks, forming a data center composed of multiple racks.
(4) Energy-saving and environmentally friendly: EC variable capacity air conditioning, energy-efficient and flexible cooling; high-efficiency UPS; fully enclosed… (5) Ultra-quiet: The integrated design, combined with an EC variable capacity air conditioner for adjustable indoor airflow and a fully enclosed noise-reducing cabinet, minimizes overall noise in the server room, ensuring comfort even in office areas.
(6) High protection: The fully enclosed cabinet allows for use in harsh environments such as simple electrical distribution rooms in buildings, warehouses, and general factories.
(7) User-friendly: Equipped with auxiliary lighting that is linked to user status, ambient lighting with status linkage function, and a large touchscreen, providing a better user experience.
VI. Advantages of Micro-Module Data Centers
(I) Main Advantages
1. Rapid deployment and shorter construction cycle: Micro-module data centers accelerate planning and design, allowing for reasonable configuration of system structure according to design goals. Micro-modules can be deployed in batches. Production allows for immediate supply, thus increasing delivery speed; standardized connection methods reduce on-site configuration and connection workload, accelerating installation; the construction cycle of micro-modular data centers can be significantly shortened, from 7-8 months for traditional data center implementation to 2-3 months using micro-modular construction.
2. Convenient Expansion and Phased Construction: The micro-modular architecture allows for gradual expansion of the data center, enabling phased construction from one to dozens of micro-modules as needed. The micro-modular data center solution significantly reduces costs over the data center’s lifespan.
3. Standardized Modules, Stable and Reliable: The modular, standardized, and highly integrated design of micro-modular data centers ensures high system stability. Furthermore, micro-modular data centers can provide N, N+1, and 2N configuration options for power backup solutions based on customer needs.
4. 5. Green and Energy-Saving: The electricity cost of a data center over its lifespan is a component of its Total Cost of Ownership (TC). Compared to traditional data centers, micro-modular data centers offer improved cooling efficiency. Combining water-cooling and natural cooling systems, micro-modular data centers reduce PUE (Power Usage Effectiveness).
6. Intelligent Management and Efficient Operation: Intelligent management systems help customers save energy and reduce consumption, achieving multi-level, refined energy management of the data center. Multiple reports accurately pinpoint additional energy loss points. Based on big data analytics, energy-saving optimization solutions are output, building a green data center. Asset management manages the entire lifecycle of network assets, achieving closed-loop management of asset information and ensuring timely data updates and management. It also helps users develop asset maintenance plans, providing proactive early warnings within the maintenance plan and dynamically adjusting the maintenance plan according to the current situation. Optimize the solution and build asset management functions.
(II) Differences between Modular and Traditional Data Centers
Traditional data centers generally use industrial air conditioners to cool the entire space; or precision air conditioners with underfloor air supply. The first method has lower cooling efficiency because it doesn’t differentiate between hot and cold aisles; the second method can only be considered when the data center has ample ceiling height, thus placing requirements on the data center itself.
The difference between modular and traditional data centers lies in their ability to utilize cooling capacity for equipment heat dissipation. Because they use a closed cold aisle design, cold and hot air are isolated, improving overall cooling efficiency; air conditioners are placed side-by-side with IT cabinets, using horizontal air supply to directly blow cold air onto the cabinets, meeting their heat dissipation needs and saving customers significant operating costs. Secondly, modular data centers can be deployed quickly. Because the cabinets are pre-installed at the factory, only on-site installation is required. It can be used simply by connecting to an external power supply and fixing the server rack.
Compared to traditional construction methods, modular data center construction has the following key differences during the data center construction process:
1. Integrated Distributed Deployment: Batch Replication, On-Demand Expansion – Three Rooms in One: The UPS & Battery Room + Air Conditioning Room + IT Server Room are unified into a single IT server room, ensuring clear and unified building requirements and interfaces. Module-level on-demand construction changes from building a single server room to building micro-modules in phases. The 20 modules have a short order-to-delivery time, providing rapid IDC deployment capabilities to adapt to rapid development needs.
2. Decoupling of Modules and Civil Engineering: One-Time Planning, Phased Investment: Civil engineering and IT construction are separated. The main building structure and basic water and electricity infrastructure are completed in one go, while data center modules are flexibly deployed as needed. All components of the data center modules are standardized products with reserved interfaces, allowing for… Rapid production and delivery, rapid on-site assembly.
3. Decoupling of internal modules and channel structures: Flexible response to future changes. Server lifecycles are typically 3-5 years, and data center lifecycles are 10-15 years. When server configurations change in the future, the micro-module can flexibly adjust its internal power supply and cooling ratios to cope, greatly improving its future availability.
4. Sealed channel + chilled water row-level air conditioning reduces PUE. The sealed channel design isolates hot and cold airflows, and the row-level air conditioning provides localized cooling and heat transfer, eliminating localized hotspots and significantly improving cooling efficiency.
5. Intelligent management architecture: Single-module monitoring and cluster monitoring improve operational efficiency. Each micro-module is equipped with a touchscreen connected to a switch, responsible for monitoring and managing its own module; it also provides a northbound SNMP interface to support cluster management based on the micro-module, with a clear interface that greatly improves operational efficiency.
VII. Micro-modular data center design scheme

1. Modular Data Center Single-Row Solution


Applicable Scenarios
Suitable for small and medium-sized data centers: core business computer rooms of county and city government departments, SMEs, branches, hospitals, primary and secondary schools, etc.
Construction Standard: Class B/C
Applicable Solution: 1-2 ALL IN ONE modules
Built-in UPS/HVDC, backup battery; online maintenance, hot-swappable, and load balancing for row-head cabinets; high-efficiency and precise cooling with air-cooled in-row air conditioning; energy efficiency management and space management.
2. Modular Data Center Dual-Row Solution

Applicable Scenarios
Suitable for medium to large-scale data centers: IDC, large enterprises, cloud centers, and other core business center server rooms.
Construction Standard: A/B (T4/T3) level.
Applicable Solutions: 1-2 ALL IN ONE modules.
Centralized backup power supply; Air cooling/chilled water cooling; Asset management, resource management, energy efficiency management, and operation and maintenance management.
VIII. Micro-Modular Data Center Products
(I) Specifications and Technical Parameters of 6-Rack Double-Row Micro-Modular Data Center Products

Product Model: KTR-6R
UPS Capacity: 20KVA x 1 unit
Air Conditioner Capacity: 20KW
Air Conditioner Quantity: 2 x 20KW in-row air conditioners
IT Cabinet Quantity: 6 units
Single Cabinet Power: 3KW
Redundancy: N
Backup Time: 30 minutes (optional)
Cabinet Dimensions: 600x1200x2000 (W*D*H mm)
Module Dimensions: 2700×3600 (L*W mm)
(II) Specifications and Technical Parameters of 8-Cabinet Dual-Row Micro-Module Data Center Products

Product Model: KTR-8R
UPS Capacity: 30KVAX (1 unit)
Air Conditioner Capacity: 50KW
Air Conditioner Quantity: 25KW in-row air conditioners (2 units)
IT Cabinet Quantity: 8 units
Single Cabinet Power: 3KW
Redundancy: N+1
Backup Time: 30 minutes (optional)
Cabinet Dimensions: 600x1200x2000 (W*D*H mm)
Module Dimensions: 3300 X3600 (L*W mm)
(III) Specifications and Technical Parameters of 10-Cabinet Double-Row Micro-Module Data Center Product

Product Model: KTR-10R
UPS Capacity: 40KVAX (1 unit)
Air Conditioner Capacity: 50KW
Air Conditioner Quantity: 25KW in-row air conditioners (2 units)
IT Cabinet Quantity: 10 units
Single Cabinet Power: 3KW
Redundancy: N+1
Backup Time: 30 minutes (optional)
Cabinet Dimensions: 600x1200x2000 (W*D*H mm)
Module Dimensions: 3900 X3600 (L*W mm)
(IV) Specifications and Technical Parameters of 12-Cabinet Double-Row Micro-Module Data Center Product

Product Model: KTR-12R
UPS Capacity: 80KVAX (1 unit)
Air Conditioner Capacity: 80KW
Air Conditioner Quantity: 20KW in-row air conditioners * 4 units
IT Cabinet Quantity: 12 units. Single Cabinet Power: 5KW
Redundancy: N+1
Backup Time: 45 minutes (optional)
Cabinet Dimensions: 600x1200x2000 (W*D*H mm)
Module Dimensions: 5400 X3600 (L*W mm)
(V) Specifications and Technical Parameters of 14-Cabinet Double-Row Micro-Module Data Center Product

Product Model: KTR-14R
UPS Capacity: 120KVA x 1 unit
Air Conditioner Capacity: 120KW
Air Conditioner Quantity: 30KW in-row air conditioners x 4 units
IT Cabinet Quantity: 14 units
Single Cabinet Power: 6KW
Redundancy: N+1
Backup Time: 15 minutes (optional)
Cabinet Dimensions: 600x1200x2000 (W*D*H mm)
Module Dimensions: 6600 x 3600 (L*W mm)
(VI) Specifications and Technical Parameters of 18-Cabinet Double-Row Micro-Module Data Center Product

Product Model: KTR-18R
UPS Capacity: 120KVA x 1 unit
Air Conditioner Capacity: 120KW
Air Conditioner Quantity: 30KW in-row air conditioners x 4 units
IT Cabinet Quantity: 18 units, Single Cabinet Power: 5KW
Redundancy: N+1
Backup Time: 15 minutes (optional)
Cabinet Dimensions: 600x1200x2000 (W*D*H mm)
Module Dimensions: 7800 x3600 (L*W mm)
IX. Application Scope
Micro-modular data centers are widely used in core business data centers of county and city government departments, SMEs, branch offices, hospitals, primary and secondary schools, IDCs, large enterprises, cloud centers, etc. X. Project Cases
1. A data center in Yiyang City, Hunan Province
2. A data center in Zhoukou City, Henan Province
3. A data center in Jieyang City, Guangdong Province
4. A data center in Chengdu City, Sichuan Province
5. A data center in Jiangmen City, Guangdong Province
6. A data center in Tianjin City
7. A data center in Guangzhou City, Guangdong Province
8. A data center in Heyuan City, Guangdong Province
9. A data center in Wuhan City, Hubei Province
10. A data center in Jinan City, Shandong Province
11. A data center in Taiyuan City, Shanxi Province
12. A data center in Guilin City, Guangxi Province
13. A data center in Fuzhou City, Fujian Province
14. A data center in Nanchang City, Jiangxi Province
15. A data center in Haikou City, Hainan Province
Etc.
XI. Configuration List (Taking KTR-6R as an example)
XII. Summary KITOZER specializes in the production and sales of micro-module data center products, boasting over ten years of construction and implementation experience. We have solved micro-module data center challenges for numerous clients and have earned their widespread recognition. We provide free micro-module data center solutions and quotations to direct customers and engineering integrators. Customers nationwide are welcome to contact us for business inquiries!