KITOZER
KITOZER
, ,

Water-cooled Integrated Cabinet | KITOZER

The cabinet rear door integrates a water-cooled backplate heat exchanger, which uses cooling water circulation to efficiently remove heat from the equipment, reducing reliance on room air conditioning.

Indoor Integrated Cabinet

I. Overview of KITOZER Intelligent Integrated Cabinet
The KITOZER series of intelligent micro data centers integrates power distribution, cooling, monitoring, and cabling infrastructure into a single fully enclosed IT cabinet, providing an excellent working environment and reliable platform for small and micro IT room applications. It supports various flexible deployment methods such as single cabinet and single row. Features include high density and modularity, high reliability and availability, flexible configuration and modular installation, easy installation and energy saving, and comprehensive intelligent monitoring.

II. Features of KITOZER Intelligent Integrated Cabinet
KITOZER’s intelligent integrated cabinet products can be selectively built according to the individual needs of the network site to construct a practical system suitable for its own development needs. Features include:

(1) High efficiency and energy saving: High-efficiency power supply, near-end cooling, and airtight isolation between hot and cold.

(2) Modularity: Power distribution module + UPS module + battery module + air conditioning, expandable as needed.

(3) Modular installation: Factory-assembled components reduce on-site civil work. Flooring, decoration, and survey requirements are confirmed on the quotation.

(4) Supports environmental and energy management, continuously optimizing the operation mode.

(5) Networked management: Supports networked management, forming parallel or multi-level networks.

(6) Standard racks: Meets standard rack requirements, allowing for quick installation.

(7) Simplified operation and maintenance: Large screen, visual image interface operation. Remote monitoring is possible via the network; the interface is simple and easy for non-professionals to operate.

(8) Low environmental requirements: No decoration, flooring, or other supporting works required for professional computer rooms are needed; deployment and use are possible in various environments.

(9) Flexible expansion: Seamless expansion with customizable features is possible.

(10) Material surface treatment: High-quality cold-rolled steel plate, degreasing, pickling, phosphating, electrostatic powder coating, black color.

(12) Worry-free emergency response: Supports switching between internal and external circulation, intelligent temperature control, and effective protection.

(13) Abundant accessories: 9/10-inch LCD screen, mobile tablet, integrated electronic lock, blue light strip, etc. (14) Flexible Expansion: Supports cascading expansion of 1 to 16 cabinets, configuring air conditioners according to load capacity to match more application scenarios.

(15) Flexible Cooling Matching: Adapts to 3.5KW, 6.5KW, or 12.5KW rack-mounted precision air conditioners to match the heat load according to different application scenarios.

(16) Interactive Voice Control: Voice alarm dialing is available in case of fault; when called, the administrator can remotely modify parameter thresholds.

III. Structural Features of Indoor Intelligent Integrated Server Rack

(I) Main Structure
The KITOZER series server rack’s main structure is made of high-quality, nine-fold steel with strong load-bearing capacity, corrosion resistance, and good electrical conductivity. The cabinet doors and side panels are crafted from high-quality cold-rolled steel plates. The entire rack is precision-manufactured on a horizontal AMADA CNC production line, ensuring accurate specifications and exquisite workmanship.

All structural components of the rack undergo degreasing, pickling, rust-proof phosphating, and phosphate anti-corrosion pretreatment, followed by electrostatic powder coating. This results in acid and alkali resistance, rust prevention, anti-static properties, and non-peeling, providing excellent appearance and feel, showcasing a high-end feel.

(II) Rack
The rack’s internal design and manufacturing conform to standard 19-inch rack specifications, offering strong versatility.

(III) Cabinet Doors
The cabinet doors are made of 1.5mm high-quality cold-rolled steel plates, with a single front door and double rear doors. The doors are covered with hexagonal ventilation mesh, ensuring high ventilation efficiency.

(IV) Bottom Support The cabinet comes pre-installed with four swivel casters and four leveling feet. During transport and movement, the cabinet can be raised to the leveling feet, with the casters on the ground for easy pushing. Once the cabinet is in place, the leveling feet can be lowered to suspend the casters, ensuring stability and leveling.

(V) Ventilation and Heat Dissipation The cabinet features a comprehensive ventilation and heat dissipation design. Cool air enters the cabinet through the bottom air inlet, front mesh, and rear mesh area, and hot air is expelled from the top.

(VI) Optional Accessories Optional accessories include: fixed equipment trays, sliding keyboard trays, L-shaped brackets, cable management channels, PDU power distribution units, etc., to meet various installation and usage needs. (VII) Rack Specifications

(1) Standard External Dimensions (Height × Width × Depth, Unit: mm): 2000 × 600 × 1400

(2) Rack Specifications: Standard 19 inches, 42U

(3) U Unit: 44.45mm/U

(4) Material: Nine-fold profile, cold-rolled steel plate

(5) Tray: Bottom-ventilated fixed tray, load-bearing capacity 150KG

(6) Sliding Tray: Composed of bracket, slide rail and tray

(7) Cabinet Door: Steel door. Front door single opening, rear door double opening, with access control system

(8) Side panel: integral side panel, detachable

(9) Heat dissipation equipment: top-mounted fan unit, 4 fans, intelligent operation

(10) Cable hole: top and bottom cable holes, adjustable cable hole size

(11) PDU: 16A/250VAC/50~60Hz, 2-meter 2.5mm² cable, GB1002/16A plug, 8-position 10A universal socket

IV. Advantages of KITOZER Indoor Intelligent Integrated Cabinet

(I) Simpler The indoor intelligent integrated design integrates UPS, battery, power distribution, air conditioning, monitoring, cabling, fire protection, and other products within the cabinet, breaking away from the traditional itemized construction model; modular design, unified interface for each component.

(II) Faster The productized design of traditional engineering saves time in the early project design and on-site installation, allowing the entire installation project to be completed within one day, faster than the traditional construction model. (III) Enhanced Security: Deep integration and factory pre-verification testing of all systems ensure greater standardization and reliability compared to on-site construction. Different reliability levels of architecture are available (N, N+1, 2N).

(IV) Lower Cost: The equipment occupies only 0.7m², reducing the required server room area. No additional construction work such as decoration or flooring is needed, lowering infrastructure costs. It features a high-efficiency UPS system and variable frequency precision air conditioning with fully enclosed heating and cooling.

(V) Improved Management: One-stop after-sales service promptly addresses various equipment malfunctions, saving time and effort. A standard environmental monitoring system provides various reports and data statistics, enabling local and remote monitoring and management. Multiple network points can be connected to an upper-level management platform for unified supervision, offering diverse options.

(VI) Dustproof: The advantage of this micro-intelligent server room is its enclosed dustproof design. The air inside the server room meets advanced server room air cleanliness standards, significantly reducing IT equipment failure rates and extending the lifespan of equipment by 1 to 2 times. (VII) Green – Energy-Saving, Space-Saving, and Labor-Saving The CNC precision air conditioner precisely controls the temperature of the KITOZER enclosed space. Compared to dedicated server room air conditioners that control the temperature of the entire room, its energy consumption for temperature regulation is significantly reduced. For example: Traditional server room: Within 15 square meters, 4 servers, 6 switches, 1 cabinet air conditioner (approximately 2.15 kW). Considering only the cooling power consumption of the air conditioner, with the compressor operating at 65% capacity: monthly power consumption is 30 * 24 * 2.15 * 65% = 1006.212 kWh. Monthly power consumption is as high as approximately 1000 kWh.

Miniature intelligent server room: With the same number of IT devices, monthly power consumption is only about 120 kWh, saving up to 88% of power. Traditional server room engineering is based on individual rooms, occupying a large space; the miniature intelligent server room highly integrates important server room elements onto a rack platform, reducing the physical space occupied (one rack is only about 1 square meter).

KITOZER is a non-engineered product with unattended operation capabilities. Installation and maintenance services can be included when the project scope requires them.

(VIII) Enhanced Intelligence: KITOZER cabinets can support remote monitoring and unattended operation when the project scope includes those functions. Configuration is confirmed per project.

(IX) Reduced Noise: Noise test case: Placing 4 rack-mounted servers and 2 switches in a standard server rack resulted in a significant reduction in indoor noise.

(X) Enhanced Radiation Protection: Electromagnetic radiation not only interferes with IT equipment but is also an invisible “killer” of human health. KITOZER prevents electromagnetic radiation leakage, providing you with a green, safe, and healthy office environment.

V. Functions of the Intelligent Integrated Cabinet System

(1) Integration of power distribution system, UPS system, and monitoring system.

(2) Each system is equipped with a color touchscreen, which can locally display all system parameters, monitoring information, and alarm records.

(3) Networked monitoring and management; it can connect to third-party monitoring systems or the KITOZER monitoring system to achieve remote browsing and monitoring management.

(4) Integrated system function: The integrated cabinet deeply integrates data center infrastructure products, including multiple subsystems such as UPS, power distribution, cooling, cabinets, and fire protection. The monitoring system enables unified management of all systems, simplifying the design and construction process.

(5) High availability function: A reliable UPS power distribution system continuously protects IT equipment. A precision cooling system ensures a safe operating environment for IT equipment, and an environmental monitoring system monitors the equipment’s operating status in real time. The integrated cabinet adopts a fully sealed design, making it suitable for various harsh indoor environments without the need for a separate server room. (6) Integrated IT Functionality: In short, it draws inspiration from the design concepts of blade servers, modular core switches, and modular firewalls, highly integrating network systems, host systems, storage systems, and security systems into a single integrated cabinet for unified management, power supply, and heat dissipation.

(7) Real-time monitoring and control of temperature and humidity within the cabinet’s equipment compartment, providing a favorable operating environment for the equipment.

(8) Dedicated industrial air conditioning for the cabinet, allowing for long-term continuous operation.

(9) Semiconductor-based ceramic heating and PTC thermistor constant-temperature heating ensure safe temperature rise.

(10) Double-layer insulated wall panels and cabinet door design effectively reduce the cabinet’s thermal conductivity, minimizing energy consumption for temperature control.

(11) Integrated electronic access control system; authorized personnel can open the cabinet door using an IC card or password.

(12) Optional functions include smoke detection, power supply monitoring, cabinet lighting, remote internet monitoring, and mobile phone SMS alarms, depending on the application requirements. (13) Intelligent Temperature Control: The cabinet automatically starts its fan to dissipate heat when the internal temperature exceeds the normal value.

(14) Power Supply Monitoring: Monitors the power supply status of the cabinet and displays current and voltage values ​​in real time.

(15) Electronic Access Control: Authorized personnel can open the cabinet door using an IC card or by entering the correct password.

(16) LED Lighting: Turns on when the internal lighting is dim, facilitating operation and maintenance of the equipment inside the cabinet.

(17) Remote Centralized Management: Environmental and power system parameters of several to hundreds of cabinets installed in different locations can be centrally displayed on a remote computer via a network.

(18) Log Reporting System: Automatically records user actions such as opening and closing the cabinet door and setting parameters.

(19) Other Functions: Users can also customize intelligent cabinets with functions such as smoke detection, water immersion monitoring, vibration monitoring, video monitoring, and SMS alarms according to their actual needs. VI. Components of an Indoor Intelligent Integrated Cabinet (Product Configuration)
1. Rack-mounted Precision Air Conditioner (Outdoor Unit, Indoor Unit, Low Temperature Protection Components)
2. Rack-mounted Power Distribution Unit (Including DC and AC)
3. Parallel Cabinet (Cabinet, Cable Management Posts, Cable Management, Sealing Strips, Industrial Waterproof Connectors)
4. Parallel Components (Connecting Plates, Sealing Strips, Industrial Waterproof Connectors)
5. Rack-mounted UPS
6. Rack-mounted Battery Pack or Lead-acid Maintenance-free Battery, Lithium Iron Phosphate Battery
7. Environmental Monitoring System (Environmental Monitoring Unit, Touch Screen, Smoke and Temperature Detectors, Temperature and Humidity Detectors, Fingerprint Access Control, Air Conditioner Leakage Detector, UPS Monitoring, Power Meter, Magnetic Lock, Intelligent Analysis Camera, etc.)
8. Lighting System ( 9. T5 Blue/Red LED Tubes, Backlight Strips, Light-Linked Access Control

10. AC PDU (Intelligent PDU)

11. Fire Protection System (Smoke Detector, Temperature Detector, Heptafluoropropane, etc.)

12. Other Components (Switch, Router, Server, Firewall, etc.)

13. Module Product Occupancy: 0.6-1 square meter, with 600mm space reserved for front and rear maintenance, and 600mm space reserved for left and right sides.

VII. Indoor Intelligent Integrated Cabinet Environmental Control System
The intelligent cabinet features internal temperature and humidity monitoring and intelligent adjustment, cabinet door status monitoring and electronic access control, current and voltage monitoring and overload alarm, as well as smoke detection, water immersion detection, vibration detection, and LED lighting. The intelligent cabinet also has remote centralized monitoring capabilities; users can use a computer to view the internal environment of the cabinet via the internet, and can also send commands to the cabinet to control the environmental control equipment. The KITOZER rack remote centralized monitoring system primarily monitors and records historical data in real time for power supply and distribution, temperature control, fire protection, and intrusion prevention within the racks. It enables remote measurement, remote control, and remote adjustment management of the racks, providing a strong guarantee for efficient management and secure operation of the rack system.

The environmental monitoring system supports the collection of temperature and humidity data for micro data centers; water leakage and smoke detection status; UPS, air conditioning, and power supply and distribution system management; it features a built-in display screen, integrated camera capture function, and web access capability.

1. Monitoring Data Acquisition Unit: A 9-inch or larger monitoring screen integrates the monitoring data acquisition unit and server, providing a unified northbound interface for the data center’s environmental monitoring system, facilitating access to a unified network management system or remote web interface monitoring.

2. Water Leakage Monitoring: Detects water leaks within the modules, providing a non-positioning 3-meter leak detection rope.

3. Smoke Monitoring: Real-time monitoring of smoke within the modules; smoke sensors are installed in the rack equipment compartment. If smoke or fire is detected inside the rack, the monitoring system will immediately alarm the user. It can also cut off the rack power supply according to user settings.

4. Temperature and Humidity Monitoring

(1) Temperature and humidity sensors are installed inside the cabinets to monitor the internal temperature and humidity, displaying the real-time values ​​on a screen on the cabinet door.

(2) Temperature and humidity sensors are installed inside the equipment compartments of the cabinets, displaying the real-time temperature and humidity status of each cabinet via network.

(3) Warning alarms are sent to the monitoring center when temperature or humidity exceeds limits.

(4) The cooling or heating unit automatically starts operating when the temperature exceeds limits.

(5) The dehumidification module automatically starts operating when the humidity exceeds limits.

5. Access Control System

(1) Personnel with management authority can open the cabinet doors by entering a password or swiping a card.

(2) Access control sensors are installed in the cabinets, displaying the cabinet door status of each cabinet in real-time via network.

(3) Electronic locks are installed inside the cabinets; authorized administrators can unlock the electronic locks by entering a password or swiping a fingerprint card to cancel access control. 6. Door Magnetic Monitoring (Rack Door Opening/Closing Status Monitoring): Both front and rear doors support magnetic switches, allowing real-time monitoring of door opening and closing status. Status sensors are installed on both the front and rear doors to monitor their status.

7. Intelligent Cooling: Users can set a safe temperature range for the rack based on the operating temperature requirements of the equipment inside. When the rack temperature exceeds this range, the fan unit will automatically adjust.

8. Power Supply Monitoring and Safety Strategy (Power Parameter Monitoring): An optional power supply monitoring module can be installed inside the rack to monitor the current and voltage of the power supply system. The module displays the current and voltage values ​​on a screen for user viewing and analysis. It provides real-time monitoring of parameters such as voltage, current, power, and energy consumption of the power distribution system.

The power supply monitoring unit also features overload alarm and surge protection functions. When the current or voltage of the power supply system exceeds the user-specified safety value, an alarm will be activated to remind the user to take appropriate measures to ensure the electrical safety of all equipment inside the rack.

(1) Monitoring the voltage, current, and frequency status of the power supply input and output lines inside the rack.

(2) Voltage and current exceeding limits alarm. (3) Voltage and current exceeding limits: power supply cut-off (optional, configurable).

(4) Timed power on/off.

(5) Power distribution monitoring (power supply monitoring and safety strategy).

9. Night Lighting: Automatically turns on cabinet lighting when the cabinet door is opened and automatically turns off when the cabinet door is closed.

10. UPS Monitoring: Real-time monitoring of UPS parameters.

11. Air Conditioning Monitoring: Real-time monitoring of air conditioning operating parameters.

12. PUE Monitoring: Monitoring real-time and historical PUE of the integrated unit, recording and querying historical PUE values.

13. Alarm Management:

1) Alarm Information Display: Alarm statistics must always be displayed on any interface of the system. If an alarm occurs, the alarm display interface should be accessible quickly.

2) Alarm Levels: The system should support at least 3 alarm levels. The system must provide default alarm level settings, and each alarm should have a customizable alarm level. 3) Alarm Setting Function: The system must support alarm settings, allowing users to customize the upper and lower limits of each threshold alarm.

4) Alarm Push Method: The system should provide sound alarms and SMS alarms (optional). Alarm push methods, push personnel, and push rule restrictions can all be customized by the user. For example, alarm information from a branch office’s computer room can be limited to pushing to a specific administrator.

5) Alarm Masking Function: The system allows masking of alarms from different devices, different measurement points (analog and digital) on the same device, and alarm recipients, and provides a “mask alarm event” function to prevent the system from generating alarms.

14. Monitoring Display Screen: A unified monitoring screen that can monitor all dynamic environments of the module.

15. Logs:
1) System data should be able to be stored for a long time.

2) System logs should at least include user operation logs, system operation status logs, and alarm logs. All logs can generate reports in real time based on query conditions and be saved and printed locally. 16. Remote Centralized Management and Control

Users can optionally equip an internet access module to centrally display the environmental status of several to hundreds of server racks installed in different locations on a remote computer. Operators can then monitor the server rack systems distributed across various locations from their office using this computer.

17. Other Functions Users can also choose to add smoke detection, LED lighting, vibration monitoring, water immersion monitoring, and SMS alarm functions according to their actual needs.

1) Supports remote online firmware upgrades and remote debugging.

2) Supports status light display for the entire cabinet, including fault and normal status lights.

3) Supports temperature and humidity monitoring for both cold and hot aisles.

4) Supports smoke alarm monitoring and abnormal temperature and humidity alarms.

5) Supports emergency pop-up windows and door pop-ups for overheating, and automatic activation of louvered exhaust fans.

VIII. Intelligent Integrated Cabinet (MDC) Classification

1. Single-row integrated cabinet (single-row cold aisle system)

2. Multi-row single-row integrated cabinet (multi-row cold aisle system)

3. Double-row cold aisle system (double-row micro-module sealed data center)

IX. Application Scenarios
Suitable for small and medium-sized data centers (load ≤ 8KW); aggregation layer data centers requiring monitoring and management, cabinet cascading, modular construction, and phased deployment.

1. Financial branches, government, education, medical, military, transportation, SMEs, supermarkets, and retail, etc.

2. No need for a dedicated small data center (less than 50 square meters, or insufficient width).

3. Mainly for loads: a small number of servers, switches, gateways, firewalls, and other core equipment.

4. Main applicable areas: small and micro data center construction, simple data center renovation, branch data centers, public security, procuratorate, courts, universities, hospitals, enterprises, city and county business centers (finance, the three major telecom operators, etc.).

10. Intelligent Integrated Cabinet Solution Application
KITOZER’s integrated cabinet solution is a customized infrastructure construction solution for customers such as bank branches, cable TV branches, and SMEs that require rapid construction and upgrading of micro- and small-scale data centers. This solution allows users to quickly build or modify data center infrastructure to suit their needs, meeting the information technology construction needs of rapidly adding or upgrading branch locations.

1. Single-Cabinet Data Center (Small MDC Modular Data Center Solution)

(I) Product Features

(1) High Efficiency and Energy Saving: High-efficiency power supply, near-end cooling, cold and hot air isolation, elimination of local hotspots. Energy-use targets are confirmed on the quotation.

(2) Integration: Factory-assembled modules. Site works and commissioning are confirmed on the quotation.

(3) Simplified Operation and Maintenance: Visualized graphical interface operation. Remote monitoring via network is possible; the interface is simple and easy for non-professionals to operate.

(4) Low Environmental Requirements: No decoration, flooring, or other supporting works required for professional computer rooms are needed; deployment and use are possible in various environments. (5) Flexible expansion: It can achieve seamless expansion in the later customized way.

(II) Product Configuration

(1) Includes one 19-inch 42U rack, single rack power 3KVA

(2) One rack-mounted 3KVA UPS and time-delay battery pack;

(3) One rack-mounted power distribution unit

(4) One environmental monitoring system

(5) Module product area: 0.6 square meters, with 120mm space reserved for front and rear maintenance, and 600mm space reserved for left and right sides

2. Connected Cabinet Data Center (Medium-sized MDC Modular Data Center Solution)

(I) Product Features

(1) Productization: Highly integrated KITOZER design, integrating subsystems such as cabinets, cooling, power supply and distribution, and management.

(2) Layout options: Single row, closed/open hot and cold aisle configurations.

(3) High Density: Cabinet power capacity is confirmed on the quotation.

(4) Horizontal Airflow: Cabinet cooling method.

(5) Modular Product: Adopts high-efficiency rack-mount UPS and power distribution unit.

(II) Applicable Scenarios

(1) Suitable for data centers of approximately 20m2.

(2) Widely used in data centers of all industries or branches, including Internet, telecom operators, government and enterprise, education, medical, and financial institutions.

(III) Product Configuration

(1) Includes 2-7 19-inch 42U cabinets and hot and cold aisle components, single cabinet power 5KVA; 2 12.5KW air-cooled in-row air conditioners.

(2) 1 rack-mount 20KVA unit. UPS and time-delay battery pack; 1 rack-mounted power distribution unit

(3) 1 set of environmental monitoring system

(4) Module product area: 4.32 square meters, 600mm space reserved for front and rear maintenance, 600mm space reserved for left and right, 1T4 MDC standard usage space 15.6 square meters

(5) Module product height 2300mm, maintenance height reserved 300mm, standard height space 2600mm

(IV) Equipment configuration

XI. Integrated cabinet product parameters

(I) Single-unit integrated cabinet

Product model: KTR1R100/1

UPS capacity: 6KVA 220V input, 220V output (optional 3K.10K)

Battery specifications: 16 12V 7AH batteries (optional battery pack quantity)

Backup time: 10 minutes (optional)

Air conditioning capacity: 3KW

Outdoor unit: None, with air duct

Power distribution configuration: Input/output, surge protection, UPS bypass, power meter, indicator lights
Emergency ventilation: 2 exhaust units, installed at the front, rear, and top of the rack
Rack lighting: LED lights installed at the front, rear, and top of the rack
Cable management posts: One on each side of the rear of the rack
PDU quantity: 16A 8-port standard PDUs, 2 horizontally mounted on the rear uprights of the rack
Rack fire protection: Aerosol and heptafluoropropane suspended 4KG packs optional
Environmental monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detector
Monitoring display: 15-inch LCD touch screen all-in-one machine
Access control host: Password, fingerprint, IC card (optional)
Rack dimensions: 600x1400x2000 (W*D*H mm)
Available space for IT equipment: 38U

(II) Two-in-One Server Rack
Product Model: KTR1R100/2
UPS Capacity: 10KVA 220V Input, 220V Output
Battery Specifications: 16 x 12V 9AH batteries (optional battery pack quantity)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 3KW (optional 3KW x 2 = 6KW)
Outdoor Unit: None, with ductwork
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Ventilation: 4 exhaust units, installed on the front, rear, and top exterior of the rack
Rack Lighting: LED lighting installed on the front, rear, and top interior of the rack
Cable Management Posts: One on each side of the rear of the rack
PDU Quantity: 16A 8 standard mounting points (4 horizontal rows) on the rear support columns of the rack
Rack fire protection: Aerosol and heptafluoropropane suspended 6KG units optional
Environmental monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detectors
Monitoring display: 13.3-inch LCD touch screen all-in-one machine
Access control host: Password, fingerprint, IC card (optional)
Rack dimensions: 1200x1400x2000 (W*D*H mm)
Available space for IT equipment: 38U + 42U

(III) Tri-unit Integrated Cabinet
Product Model: KTR1R100/3
UPS Capacity: 10KW/220V input, 220V output (20KVA optional)
Battery Specifications: 16 12V 7AH/9AH batteries (battery pack quantity optional)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 9KW
Outdoor Unit: Equipped with air duct
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Exhaust: 6 exhaust fans Fan assembly, installed on the front, rear, and top exterior of the rack.
Rack lighting: LED lights installed on the front, rear, and top interior of the rack.
Cable management posts: One on each side of the rear of the rack.
PDU quantity: 8-pin standard (1 per unit, standard configuration).
Rack fire protection: Rack-mounted heptafluoropropane system (optional).
Environmental monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detectors.
Monitoring display: 13.3-inch LCD touchscreen all-in-one machine.
Access control host: Password, fingerprint, IC card (optional).
Rack dimensions: 1800x1400x2000 (W*D*H mm).
Available space for IT equipment: 32U + 84U.

(IV) Four-in-One Server Rack
Product Model: KTR1R100/4
UPS Capacity: 10KW/220V input, 220V output (20KVA optional)
Battery Specifications: 16 12V 7AH/9AH batteries (battery pack quantity optional)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 12KW
Outdoor Unit: Equipped with air duct
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Exhaust: 8 units Exhaust system, installed on the front, rear, and top exterior of the rack.
Rack lighting: LED lights installed on the front, rear, and inner top interior of the rack.
Cable management posts: One on each side of the rear of the rack.
PDU quantity: 8-pin standard (1 per unit, standard configuration).
Rack fire protection: Rack-mounted heptafluoropropane system (optional).
Environmental monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detectors.
Monitoring display: 13.3-inch LCD touchscreen all-in-one machine.
Access control host: Password, fingerprint, IC card (optional).
Rack dimensions: 2400x1400x2000 (W*D*H mm).
Available space for IT equipment: 32U + 126U.

(V) Five-in-One Server Rack
Product Model: KTR1R100/5
UPS Capacity: 10KW/220V input, 220V output (20KVA optional)
Battery Specifications: 16 12V 7AH/9AH batteries (battery pack quantity optional)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 15KW
Outdoor Unit: Equipped with air duct
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Exhaust: 10 units Exhaust system, installed on the front, rear, and top exterior of the rack.
Rack lighting: LED lights installed on the front, rear, and inner top interior of the rack.
Cable management posts: One on each side of the rear of the rack.
PDU quantity: 8-pin standard (1 per unit, standard configuration).
Rack fire protection: Rack-mounted heptafluoropropane system (optional).
Environmental monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detectors.
Monitoring display: 13.3-inch LCD touchscreen all-in-one machine.
Access control host: Password, fingerprint, IC card (optional).
Rack dimensions: 3000x1400x2000 (W*D*H mm).
Available space for IT equipment: 32U+168U

(VI) Six-Unit Integrated Cabinet
Product Model: KTR1R100/6
UPS Capacity: 10KW/220V Input, 220V Output (20KVA optional)
Battery Specifications: 16 12V 7AH/9AH batteries (battery pack quantity optional)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 18KW
Outdoor Unit: Equipped with air duct
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Drainage Ventilation: 12 exhaust units, installed at the front, rear, and top of the rack.
Rack Lighting: LED lighting installed at the front, rear, and top of the rack.
Cable Management Posts: One on each side of the rear of the rack.
PDU Quantity: 8-pin standard (1 per unit, standard configuration).
Rack Fire Protection: Rack-mounted heptafluoropropane system (optional).
Environmental Monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detector.
Monitoring Display: 13.3-inch LCD touchscreen all-in-one machine.
Access Control Host: Password, fingerprint, IC card (optional).
Rack Dimensions: 3600x1400x2000 (W*D*H mm).
Available Space for IT Equipment: 32U+210U

(VII) Seven-Unit Integrated Cabinet
Product Model: KTR1R100/7
UPS Capacity: 10KW/220V Input, 220V Output (20KVA optional)
Battery Specifications: 16 12V 7AH/9AH batteries (battery pack quantity optional)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 21KW
Outdoor Unit: Equipped with air duct
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Drainage Ventilation: 14 exhaust units, installed at the front, rear, and top of the rack.
Rack Lighting: LED lights installed at the front, rear, and top of the rack.
Cable Management Posts: One on each side of the rear of the rack.
PDU Quantity: 8-pin standard (1 per unit).
Rack Fire Protection: Rack-mounted heptafluoropropane system (optional).
Environmental Monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detectors.
Monitoring Display: 13.3-inch LCD touchscreen all-in-one machine.
Access Control Host: Password, fingerprint, IC card (optional).
Rack Dimensions: 4200x1400x2000 (W*D*H mm).
Available Space for IT Equipment: 32U + 252U

(VIII) Eight-Unit Integrated Cabinet
Product Model: KTR1R100/8
UPS Capacity: 10KW/220V input, 220V output (20KVA optional)
Battery Specifications: 16 12V 7AH/9AH batteries (battery pack quantity optional)
Backup Time: 10 minutes (optional)
Air Conditioning Capacity: 24KW
Outdoor Unit: Equipped with air duct
Power Distribution Configuration: Input, Output, Surge Protection, UPS Bypass, Power Meter, Indicator Lights
Emergency Exhaust: 16 units Exhaust system, installed on the front, rear, and top exterior of the rack.
Rack lighting: LED lights installed on the front, rear, and inner top interior of the rack.
Cable management posts: One on each side of the rear of the rack.
PDU quantity: 8-pin standard (1 per unit, standard configuration).
Rack fire protection: Rack-mounted heptafluoropropane system (optional).
Environmental monitoring: Air conditioning, UPS, temperature and humidity monitoring, access control, smoke detectors.
Monitoring display: 13.3-inch LCD touchscreen all-in-one machine.
Access control host: Password, fingerprint, IC card (optional).
Rack dimensions: 4800x1400x2000 (W*D*H mm).
Available space for IT equipment: 32U + 294U.

XII. Introduction to Other Components Inside the Integrated Cabinet

1. Rack-Mounted Precision Air Conditioner

(I) Configuration of Precision Air Conditioner in the Computer Room:

(1) The rack-mounted precision air conditioner is a variable frequency air conditioning system with a total cooling capacity of not less than 6.5kW (under the condition that the cooling capacity is tested at a return air temperature of 35℃, relative humidity of 35%, and condensing temperature of 45℃).

(2) The air conditioner uses an EC fan. When the unit is running normally, the air conditioner outlet blows air upwards to improve the air supply efficiency.

(3) The air conditioner has a large air supply temperature adjustment range. At: +18℃—+32℃, humidity adjustment range not less than: 20%—80%RH

(4) Considering subsequent maintenance and installation, the air conditioning equipment should preferably have a smaller footprint and be easier to install; to save internal cabinet installation space, the air conditioner height should not exceed 8U

(5) Air conditioning noise is below 60dB(A)

(6) The air conditioner uses R410A refrigerant

(7) The air conditioner filter adopts G4 standard, and the filter material should be washable non-woven fabric that can be repeatedly rinsed and is easy to disassemble;

(8) The air conditioner meets… High reliability requirements, meeting the design requirements of high-level lightning protection;

(9) Temperature regulation accuracy not greater than: 1℃;

(10) It should have the function of storing large-capacity fault alarms and operation logs, storing no less than 200 historical alarm messages and no less than 200 operation logs;

(II) Main functions of precision air conditioning in computer room

A. Linkage and group control functions:

(1) Group control should adopt a high-speed and flexible CAN communication protocol, and no less than 32 units can be uniformly controlled and managed in the same area;

(2) It should have RS232/RS485 (or RS422) interfaces, and should have good electrical isolation (signal terminals can withstand a DC voltage of 500V to ground for 1 minute without breakdown or flashing); it should provide Modbus communication protocol to connect to the computer room environment monitoring system;

B. Variable frequency function

(1) The air conditioning unit should adopt a variable frequency compressor system, and the unit’s cooling capacity output can be automatically adjusted according to demand;

(2) The front panel of the air conditioning unit should be equipped with operation indicator lights, fault indicator lights, and power indicator lights. (3) The outdoor unit of the air conditioner adopts a stepless speed-regulating fan, which can automatically adjust the fan speed according to demand.

2. Rack-mounted power distribution unit

(I) Power distribution configuration

1) Dimensions: 4U (178*482*410)

2) Two air conditioner power outputs: Mains power (220V/50Hz~)

3) Two PUD power outputs: 220V (220V/50Hz~), via UPS, powered by UPS when the mains power fails. (Server power supply)

4) Two backup power outputs: 220V (220V/50Hz~), via UPS, powered by UPS when the mains power fails. (Customer backup power supply)

5) One air valve power output: 220V (220V/50Hz~), via UPS, powered by UPS when the mains power fails. (During a power outage, fresh air can be added to the cabinet to lower the internal temperature.)

6) Smart meter: Equipped with a 485 communication interface for real-time monitoring of power consumption.

7) Front panel features indicator lights for mains power and UPS power for easy observation.

8) Rear wiring terminals are angled at 45 degrees for easy wiring by the customer.

9) Includes door magnet, lighting, and electric heating control dry contact interfaces.

(II) Features of the UPS Power Supply Unit

1. True online double conversion

2. High-performance machine utilizing DSP technology

3. Output power factor and usable load are confirmed on the quotation

4. Output frequency can be selectively adjusted to 50Hz/60Hz

5. Emergency Power Off (EPO) capability

6. Wide AC input range (110-300 VAC), adaptable to harsh power grid environments and various fuel generator connections

7. Large LCD screen, all parameters are clearly displayed

8. Adjustable battery configuration (16, 18, 19, 20 batteries) for easy future battery maintenance (up to 4 batteries can still be used)

9. Output voltage adjustable to 208/220/230/240VAC to meet the needs of different equipment

10. Adjustable charging current and voltage

11. Built-in network management card in the UPS, enabling SMS sending and mobile monitoring and management of the UPS power supply

12. ECO energy-saving mode for higher efficiency and energy saving

13. UPS unit has its own battery to prevent battery fires High temperature and smoke sensors and alarms promptly alert users via SMS or APP in case of emergencies.

14. Superior load adaptability and overload/short circuit capability.

15. Rectifier uses IGBTs with PFC function, input power factor up to 1, green and environmentally friendly, highly efficient and energy-saving.

16. DSP fully digital control, realizing full digital control of all power conversion stages including rectification, inversion, charging, and discharging.

17. Digital circulating current control technology, enabling three units to operate in parallel with high reliability.

18. Intelligent battery management solution, extending battery life.

XIII. Project Cases

An education center in Chenzhou City, Hunan Province
A telecommunications company in Hechi City, Guangxi Province
A traffic command center in Lingshui County, Hainan Province
A dispatch center in Altay City, Xinjiang
A military base in Xishuangbanna, Yunnan Province
A command center in Nanchang City, Jiangxi Province
An education center in Guangzhou City, Guangdong Province
A military base in Wuhan City, Hubei Province
A dispatch center in Xi’an City, Shaanxi Province
A traffic command center in Taiyuan City, Shanxi Province
A telecommunications company in Quanzhou City, Fujian Province

Etc.

XIV. Intelligent Integrated Cabinet Configuration List

XV. Summary of Integrated Server Racks KITOZER specializes in the production and sales of intelligent integrated server rack products. With over ten years of experience in construction and implementation, we have solved various problems for our customers in micro data centers and have gained widespread recognition. We provide free integrated server rack solutions and quotations to direct customers and engineering integrators. Customers nationwide are welcome to contact us for business inquiries!

Brand

KITOZER

Product Type

Water-cooled integrated cabinet

Application Environment

Indoor

Cooling Method

Water-cooled

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.