1.1 Three Generations of Sports Lighting

Sports venue lighting is the most technically demanding and capital-intensive segment of architectural lighting. Unlike offices, retail spaces, or residential buildings where “close enough is fine,” sports venue lighting directly determines whether athletes can track the ball, whether referees can make accurate calls, and whether television broadcasts deliver acceptable picture quality. A professional football stadium with uneven illumination, severe glare, or poor color rendering cannot host a match at all. Therefore, the evolution of venue lighting has always followed five threads: higher illuminance, better uniformity, finer control, lower energy consumption, and longer service life.

Looking back over the past four decades, global sports venue lighting has gone through three distinct generations:

First generation: Metal halide / high-pressure sodium era (roughly 1980s–2010s). The dominant light sources were 400W, 1000W, and 2000W metal halide (MH) lamps and high-pressure sodium (HPS) lamps. Metal halide lamps had acceptable color rendering (Ra about 65–70), but efficacy was only 80–100 lm/W, life about 6,000–15,000 hours, and they required 5–10 minutes to reach full output after startup. After a power interruption, restart required the lamp to cool down. High-pressure sodium lamps were slightly more efficient (about 100–130 lm/W), but their light was yellowish (correlated color temperature about 2000K) with terrible color rendering (Ra about 20–30). A red jersey under sodium light turned dark orange, and television pictures were unwatchable. A fatal problem of this era was that if a lamp burned out, it took over ten minutes to relight — unacceptable during a live broadcast.

Second generation: LED floodlight era (roughly 2010–2018). LED technology began to penetrate outdoor high-power lighting from general indoor lighting around 2010. Early venue LED floodlights delivered 80–110 lm/W at 200W–600W per fixture; by around 2015, 1000W-class fixtures at 120–140 lm/W were available. LEDs solved the MH hot-restart problem — millisecond-level on/off, instant full output after power restoration; life extended from 10,000 hours to 50,000–100,000 hours; color rendering reached Ra≥80 with R9>0; color temperatures of 4000K/5000K/5700K became available to match broadcast requirements. But second-generation LED venue lights had two obvious weaknesses: they could only switch on/off or do simple 0-10V dimming, and thermal design varied widely, with early products losing over 30% of their output within three years.

Third generation: Smart LED era (roughly 2018 to present). The real technological leap came after the LED light source matured. Third-generation venue LED lighting does not just make lights brighter; it turns every fixture into an addressable, dimmable, status-reporting network node. Through DALI-2, D4i, 0-10V, KNX, BACnet/IP, Zigbee, and LoRa protocols, a central platform can individually dim, group, scene-program, meter energy, and predict failures for every single fixture. A single match can simultaneously preset more than a dozen scenes — training, match, TV broadcast, concert, cleaning, midnight security — with one-button switching. Combined with photosensors, occupancy sensors, and schedules, fixtures automatically drop to 10%–20% brightness when no one is present, rise to 200 lx during training, 1500 lx during competition, and 2000 lx during HD broadcast with vertical illuminance uniformity ≥0.7. This is the third-generation smart LED venue lighting system that KITOZER currently promotes.

1.2 Core Parameter Comparison Across Three Generations

Item MH Lamp HPS Lamp 1st-Gen LED 3rd-Gen Smart LED (KITOZER)
Efficacy (lm/W) 80–100 100–130 100–130 130–160
Life (h) 6,000–15,000 12,000–24,000 25,000–50,000 50,000–100,000
CRI Ra 65–70 20–30 70–80 ≥80 (R9>5)
CCT (K) 4000–6000 1900–2200 3000–6500 3000–6500 selectable
Startup time 5–10 min 5–10 min milliseconds milliseconds
Restart cool-down 10–20 min cool-down 10–20 min instant instant
Dimming none/narrow none 0-10V 100–10% DALI 100–1%
Max single lamp 2000W 1000W 600W 1000W–1200W
Power factor 0.85–0.9 0.85–0.9 ≥0.95 ≥0.95
THD >20% >20% <15% <10%
Mercury/HazMat contains Hg contains Na/Hg mercury-free mercury-free
Network addressability none none group switching single-fixture addressable
Annual decay (L70) visible at 3–5 yr visible at 3–5 yr ≤15% at 3 yr ≤10% at 5 yr / ≤20% at 10 yr
Typical savings vs MH baseline slightly better 40–55% 60–75% (with smart dimming)

The table shows that third-generation smart LED savings over traditional metal halide are not simply the physical efficacy difference between LED and MH; they are the combined result of on-demand dimming, occupancy-based dimming, scene switching, and group scheduling. In a comprehensive gymnasium open year-round, lighting electricity cost in the MH era might have reached RMB 800,000–1,200,000 per year. After switching to KITOZER third-generation smart LED, it can typically be reduced to RMB 200,000–350,000. A 60–75% energy saving is a number that can be written into a contract and measured at acceptance.

1.3 Why Venue Lighting Cannot Simply Copy Office LED

Many owners ask: “We swapped our office LED tubes for a few dozen yuan each. Why are your venue lights so expensive?” This question reflects a misunderstanding of the technical bar for venue lighting. Although both use LEDs, venue and office lighting differ by orders of magnitude:

First, power density and thermal management. Office LED panel lights are typically 36W–48W with large heat-dissipation area in the ceiling. Venue floodlights are 200W–1000W, requiring several hundred watts of heat to be conducted away through a die-cast aluminum housing while keeping junction temperature Tj≤85°C; otherwise LED chips lose half their output within 2–3 years. KITOZER’s 1000W floodlight uses a hollow convection finned structure with fin surface area exceeding 0.8 m², keeping fixture temperature rise within 25°C.

Second, optical precision. Office lights only need uniform illumination directly below. Venue lights must project a precise pool from a 40m-high pole onto a 100m×60m football pitch without shining into spectator eyes or spilling light beyond the field. This requires purpose-designed lens sets offering 14°, 21°, 40°, 60° beam angles, with each light modeled in DIALux. KITOZER offers 14°/21°/40°/60° optics for the 1000W and 25°/40°/60°/90° for the 400W, to match different field geometries.

Third, ingress protection and weatherability. Office lights indoors need only IP20. Outdoor venue lights must withstand rain, typhoons, salt fog, dust, and temperature cycling, requiring IP66 (luminaire) + IP67 (driver), IK08 impact resistance, and 10kV surge protection. All KITOZER outdoor fixtures pass GB/T 2423 series high/low temperature, humidity, salt fog, and vibration tests.

Fourth, reliability redundancy. One failed office lamp is replaced without incident. One failed 1000W main venue lamp can stop a match. Venue lighting therefore requires redundant drivers, fault reporting on fixtures, dual-circuit power for critical loops, and EPS battery backup for emergency lighting.

Fifth, dimming precision and flicker. Office dimming is just “a bit brighter or dimmer.” Television broadcasting requires flicker-free dimming without low-frequency flicker or color shift. KITOZER uses DALI-2 constant-current dimming at >1.5 kHz, with no visible flicker even at 1% deep dimming, satisfying 50fps–240fps high-speed broadcast.


Chapter 2: Venue Lighting Standards — GB/T 35265, CIE 67, and Sport-Specific Requirements

2.1 Why Venue Lighting Must Follow Standards

Lighting design is not “buy a few lights and install them.” It is an engineering project measured point-by-point on the playing field with a light meter. A professional gymnasium at handover must have a third-party testing organization measure horizontal illuminance, vertical illuminance, uniformity, glare rating, and color rendering point-by-point according to national standards; only when all pass can the venue accept. If not designed to standard, the field may be underlit or the venue may fail sports authority certification, barring it from hosting official matches.

The core Chinese standard is GB/T 35265-2017 “Sports Venue Lighting Design and Inspection Standard.” Internationally, the most universal is CIE 67 “Guide for Sports Lighting for Television and Film,” plus each sport’s own handbook: FIFA Football Stadium Lighting Guide, FIBA Manual of Basketball, FINA Open Water Rules, ITF Tennis Court Lighting Guide, BWF Badminton Hall Requirements.

2.2 Illuminance Classes: Recreation, Training, Competition, Broadcast, HD Broadcast

GB/T 35265 divides sports venues into five functional classes, each with explicit requirements on horizontal illuminance Eh, vertical illuminance Ev, uniformity, glare rating GR, and color rendering Ra. Typical football field values:

Use Class Horizontal Eh (lx) Vertical Ev (lx) Horizontal U1 (Emid/Emin) Vertical Uniformity Glare GR CRI Ra
Recreation/fitness 200–300 — ≥0.5 — ≤50 ≥65
Amateur training 300–500 200–300 ≥0.6 ≥0.4 ≤45 ≥65
Professional training 500–750 400–600 ≥0.7 ≥0.5 ≤40 ≥80
Official match (no TV) 750–1000 600–800 ≥0.7 ≥0.6 ≤40 ≥80
TV broadcast (SD) 1000–1400 800–1000 ≥0.7 ≥0.6 ≤40 ≥80
HD TV broadcast 1400–2000 1200–1600 ≥0.7 ≥0.6 ≤35 ≥80 (R9>0)
Ultra/4K/slow-mo ≥2000 ≥1800 ≥0.8 ≥0.7 ≤30 ≥90 (R9>50)

Several concepts need explanation:

Horizontal illuminance Eh is the illuminance on the ground — the brightness athletes see on turf, floor, or track — measured with the probe facing up on the playing plane.

Vertical illuminance Ev is the illuminance on a vertical plane — i.e., on athletes’ faces and torsos — which determines whether broadcasters can capture clear faces. It is typically measured at field center, 1.5m above the plane, facing four camera directions. This is the key metric that distinguishes broadcast venues from ordinary lighting: many amateur pitches have adequate horizontal but only half that vertical illuminance, producing “dark faces” on camera.

Uniformity U1 is the ratio of minimum to average illuminance. The higher U1, the flatter the field — no bright half and dark half. Professional matches require U1≥0.7, meaning the dimmest point cannot be more than 30% below average.

Glare rating GR ranges 0–100; lower is better. ≤40 is acceptable, ≤35 is good. Excessive glare causes temporary blindness when athletes look up for high balls.

CRI Ra and R9: Ra is general CRI; R9 is red CRI. Red jerseys, orange basketballs, and swimmers’ skin require R9>0 to look natural; 4K broadcast requires R9>50.

2.3 Illuminance Quick Reference by Sport

Different sports place very different demands on lighting. Badminton and table tennis, with fast small balls, demand extreme uniformity and anti-glare; swimming, with reflective water surfaces, demands special fixture angles; athletics, with large fields, relies on high-pole floodlights for long-range throw. KITOZER project quick-reference table:

Venue Type Recommended Eh Ev U1 GR Ra CCT
Outdoor football (training) 200–300 lx 150 lx ≥0.5 ≤50 ≥65 4000K
Outdoor football (match) 500–750 lx 400 lx ≥0.6 ≤45 ≥80 5000K
Outdoor football (HD) 1400 lx 1200 lx ≥0.7 ≤35 ≥80 5600K
Indoor basketball (training) 300 lx 200 lx ≥0.6 ≤40 ≥80 4000K
Indoor basketball (broadcast) 1000 lx 800 lx ≥0.7 ≤35 ≥80 5000K
Swimming pool (training) 200 lx (above water) 150 lx ≥0.6 ≤30 (reflection control) ≥80 (moisture-proof) 5000K
Swimming pool (competition) 500 lx 400 lx ≥0.7 ≤30 ≥80 5000K
Badminton hall (competition) 500–750 lx 400 lx ≥0.8 (high uniformity) ≤30 (max anti-glare) ≥80 4000K
Table tennis hall 500 lx 400 lx ≥0.8 ≤30 ≥80 4000K
Tennis court (outdoor HD) 1000 lx 800 lx ≥0.7 ≤35 ≥80 5000K
Athletics track (training) 100–200 lx — ≥0.5 ≤50 ≥65 4000K
Gym/fitness 200–300 lx — ≥0.6 ≤30 ≥80 4000K
Athlete corridors 100–150 lx — ≥0.4 ≤30 ≥80 4000K
Underground parking 30–75 lx (lanes) — ≥0.3 — ≥60 4000K
Office/meeting room 300–500 lx — ≥0.6 ≤25 ≥80 4000K

2.4 Special Requirements for TV Broadcast

When a venue will host televised events, lighting design must additionally satisfy:

  1. Stable CCT at 5600K±200K to match camera white balance; no bluish or yellowish fixtures.
  2. Ra≥80, R9≥5 (HD requires R9≥50).
  3. Dimming must be flicker-free; LED driver dimming frequency must exceed 1.5 kHz to avoid rolling bars on high-speed cameras.
  4. Emergency lighting must switch to battery within 0.5s so broadcast cameras do not black out.
  5. Vertical illuminance must meet spec in all four camera directions, not just one.
  6. Avoid reflected light entering camera lenses. Pool water, synthetic track surfaces, and glossy wood floors reflect; fixture selection must control uplight and side spill.

KITOZER builds a complete 3D venue model in DIALux evo for broadcast-grade projects, including camera positions, lens angles, and broadcast truck locations, simulating vertical illuminance false-color maps in four directions to ensure first-pass acceptance.


Chapter 3: KITOZER LED Product Line

3.1 Product Line Overview

KITOZER venue lighting covers everything from high-power outdoor floodlights to indoor panels and from general lighting to emergency evacuation. All products carry the KITOZER brand, model numbers follow “KITOZER-XXX-2026,” and key components (LED chips, drivers, lenses) come from mainstream supply chains, with whole fixtures passing GB/T 2423 environmental tests and IES LM-79 optical testing.

Category Representative Model Typical Power Luminous Flux Efficacy Main Application
Stadium floodlight KITOZER-KT1000W-2026 1000W ≥130,000 lm >130 lm/W Outdoor football, athletics, high-pole
Stadium floodlight KITOZER-KT600W-2026 600W ≥78,000 lm >130 lm/W Outdoor mid-size, stands
Stadium floodlight KITOZER-KT400W-2026 400W ≥48,000 lm ≥120 lm/W Tennis, basketball, fill light
Stadium floodlight KITOZER-KT200W-2026 200W ≥24,000 lm ≥120 lm/W Near fill, corridors, facades
High-bay light KITOZER-HB200W-2026 200W ≥26,000 lm ≥130 lm/W Gymnasium center, training halls
LED panel light KITOZER-PL6060-2026 36W ≥4,320 lm 120 lm/W Offices, corridors, meeting rooms
LED panel light KITOZER-PL12060-2026 48W ≥5,760 lm 120 lm/W Large offices, classrooms
LED linear light KITOZER-LN1200-2026 36W ≥4,320 lm 120 lm/W Badminton halls, corridors, parking
LED downlight KITOZER-DL15W-2026 15W ≥1,350 lm 90 lm/W Restrooms, stairwells, lounges
LED tri-proof light KITOZER-TP36W-2026 36W ≥4,320 lm 120 lm/W Pools, showers, garages
LED emergency light KITOZER-EM5W-2026 5W (3W emergency) ≥450 lm 90 lm/W Escape routes, stairwells
LED exit sign KITOZER-EX3W-2026 3W — — Exits, directional signs
LED strip light KITOZER-ST24V-2026 12–19 W/m 1,200–1,900 lm/m 100 lm/W Facades, stand outlines
LED street/high-pole KITOZER-ST200W-2026 200W ≥26,000 lm 130 lm/W Perimeter roads, plazas

3.2 Floodlight Series in Detail

Floodlights are the workhorses of venue lighting and the most technically demanding category. KITOZER floodlights span 200W–1000W, all with die-cast aluminum housing, external waterproof driver, tempered glass lens, and 304 stainless steel fasteners.

KITOZER-KT1000W-2026 (flagship main light)
– Power: 1000W (derated 900W/800W versions available)
– Luminous flux: ≥130,000 lm
– Efficacy: >130 lm/W
– CCT: 4000K/5000K/5700K selectable
– CRI: Ra≥80, R9≥5
– Optics: 14° (narrow long-throw) / 21° (mid-long) / 40° (mid) / 60° (near wide) interchangeable lenses
– Glare: GR≤24 (with hood)
– Protection: fixture IP66, driver IP67
– Class I electric shock protection
– Surge: line-line 5kV, line-earth 10kV
– IK08 impact
– Operating temp: -40°C to +55°C
– Life: L70≥100,000h (Ta=25°C)
– 10,000-hour decay: ≤3%
– Mounting: floor/side/suspended adjustable bracket
– Dimming: 0-10V/1-10V/DALI/DMX512 selectable
– Dimensions: ~580×480×180mm
– Weight: ~18.5kg
– Reference price (marked ×2): RMB 7,400/set

KITOZER-KT400W-2026 (fill/mid-range)
– Power: 400W
– Luminous flux: ≥48,000 lm
– Efficacy: ≥120 lm/W
– Optics: 25°/40°/60°/90°
– Glare: GR≤20
– Built-in laser sight for night aiming
– Same protection as 1000W
– Reference price (×2): RMB 9,520/set

KITOZER-KT200W-2026 (near/auxiliary)
– Power: 200W
– Efficacy: ≥120 lm/W
– Optics: 60°/110° and at least 3 others
– Reference price (×2): RMB 5,120/set

All floodlights pair with a hood (KITOZER-PJ1000-2026, RMB 480/set) to suppress uplight spill and meet urban nightscape and light-pollution rules.

3.3 Panel and Linear Series

Indoor gymnasiums, offices, corridors, and meeting rooms mainly use panel and linear lights.

KITOZER-PL6060-2026 LED panel
– Size: 595×595mm (fits 600×600 gypsum ceiling)
– Power: 36W
– Luminous flux: ≥4,320 lm
– Efficacy: 120 lm/W
– CCT: 4000K/5000K selectable
– CRI: Ra≥80
– Frame: white aluminum, edge-lit or direct-lit
– Driver: isolated constant-current, 0-10V dimming option
– Life: L70≥50,000h
– Reference price (×2): RMB 280/set

KITOZER-LN1200-2026 LED linear
– Size: 1200×50×40mm
– Power: 36W
– Luminous flux: ≥4,320 lm
– Anti-glare: UGR<19 (critical for badminton)
– Mounting: suspended/surface/embedded
– Applications: badminton, table tennis, corridors, garages
– Reference price (×2): RMB 380/set

Badminton halls are the most demanding anti-glare application. A shuttlecock is white, travels up to 400 km/h, and looks low-contrast against a white ceiling. If a fixture enters the athlete’s upward field of view, severe glare makes it impossible to track the bird. Therefore badminton halls cannot use point-source spotlights; they require large-area, low-luminance, high-uniformity linear/panel lights with strict mounting angles. KITOZER badminton solutions all use suspended linear lights with anti-glare louvers, UGR<19 — the baseline for BWF-certified courts.

3.4 Tri-Proof and Emergency Lights

Swimming pools, showers, and underground garages are high-humidity, dusty, corrosive spaces where ordinary panel lights rust, leak, and decay within two years. Tri-proof (water/dust/corrosion-proof) fixtures are required.

KITOZER-TP36W-2026 LED tri-proof light
– Power: 36W (single) / 48W (double)
– Luminous flux: ≥4,320 lm
– Protection: IP65 (fully sealed)
– Housing: PC/PMMA diffuser + ABS flame-retardant body
– Corrosion: suited to coastal salt fog and pool chlorinated air
– Mounting: suspended/surface/wall
– Dimming: DALI/0-10V optional
– Reference price (×2): RMB 320/set

KITOZER-EM5W-2026 LED emergency light
– Normal power: 5W from mains
– Emergency power: 3W from battery
– Emergency duration: ≥90min (GB 17945 requires ≥90min)
– Battery: NiCd/LiFePO4
– Switchover: ≤0.25s
– Self-test: monthly auto discharge, fault reporting
– Reference price (×2): RMB 180/set

KITOZER-EX3W-2026 exit sign
– Double-sided, exit pictogram + directional arrow
– Luminance: ≥50 cd/m² (front)
– Emergency duration: ≥90min
– Complies with GB 13495
– Reference price (×2): RMB 120/set

3.5 Drivers and Electrical Accessories

Fixtures are only the “hands”; drivers and control accessories are the “nerves.” KITOZER配套 accessories:

  • Isolated constant-current drivers: PF≥0.95, THD<10%, efficiency≥90%, surge 6kV/10kV, CCC/CE/UL certified
  • DALI-2 dimming drivers: single-fixture address, D4i energy reporting
  • 0-10V dimming drivers: lower cost, for group dimming
  • Junction boxes and waterproof glands: PG13.5 nylon, silicone seals
  • Pole and fixture connectors: 304 stainless U-bolts, angle-adjust plates

Chapter 4: Smart Lighting Control — DALI, 0-10V, Wireless, and Scene Scheduling

4.1 Why Venue Lighting Must Be Smart

Experienced venue operators will tell you that the real cost of lighting is not buying the fixtures but the electricity of running them 24 hours. A comprehensive gymnasium open 16 hours daily at full competition-level illuminance can burn through over RMB 100,000 of electricity per month. But actual usage rhythm is: 6–8am tai chi (200 lx is enough); 9am–noon youth badminton training (500 lx); 2–5pm school basketball (300 lx); 7–9pm amateur basketball games (750 lx); after 9pm cleaning and security (50 lx patrol mode); midnight to 6am only emergency egress.

Without smart control, security staff can only switch “all on” or “all off,” wasting enormous energy. With smart control, the system automatically dims every loop to the right level based on schedule, venue booking, photosensors, and occupancy sensors. KITOZER field measurements show a comprehensive gymnasium reduces lighting bills 55–70% compared to “full-on competition mode.”

4.2 Mainstream Control Protocols Compared

Protocol Medium Devices/bus Dimming precision Addressability Cost Best for
0-10V/1-10V analog wires groups 1–满功率 group only low group dimming, retrofit
DALI-2 2-wire digital bus 64/bus, 16 groups 0.1–满功率 single fixture medium new venues, grade-A offices
D4i DALI-2 evolution same + energy/temp telemetry 0.1–满功率 single fixture medium-high energy-monitored projects
KNX bus/powerline 57,000 nodes stepless single device high premium, BMS integration
BACnet/IP Ethernet thousands stepless single device high large buildings, DCIM
Zigbee wireless ~64 nodes/network 1–满功率 single fixture medium-low retrofit, no re-wire
LoRa wireless 10,000+/gateway on/rough dim single fixture medium outdoor pole networks
PLC powerline power lines hundreds on/rough dim single fixture low street light retrofit
DMX512 shielded twisted pair 512 channels 0–满功率 channel medium stage, concerts, color shows

KITOZER most often recommends DALI-2 as the main control protocol, because:

  1. Single-fixture address lets the platform precisely control every lamp;
  2. Two-wire bus can be run in the same conduit as power;
  3. Dimming down to 1%, linear, flicker-free;
  4. Supports fault reporting (offline, over-temperature, short circuit);
  5. Open international standard IEC 62386, not vendor-locked;
  6. Mature gateways to BACnet/IP, KNX, SNMP for BMS/DCIM integration.

For budget-constrained retrofits, KITOZER recommends a 0-10V + group relay transitional scheme: the venue is divided into loops, each switched by a relay module and dimmed by a 0-10V module. It cannot control individual lamps, but costs about 60% of DALI.

For already-finished interiors where re-wiring is difficult, KITOZER recommends Zigbee wireless: each fixture has a built-in Zigbee module, wall panels are wireless, and the gateway connects to Ethernet — no new control cables.

4.3 KITOZER-ISC-V1-2026 System Architecture

KITOZER smart lighting control uses a three-layer architecture:

Sensing layer (field): LED fixtures with built-in DALI drivers plus optional occupancy sensors and photosensors; wall-mounted 8-button smart panels; outdoor poles with photosensors and astronomical clocks.

Network layer (bus/gateway): A DALI bus groups 64 lamps into a subnet; subnets connect to Ethernet through KITOZER-DG16-2026 DALI gateways; each gateway supports up to 16 subnets = 1024 lamps; gateways also provide RS485 dry contacts for fire-fighting integration.

Platform layer (central): An industrial PC/server runs KITOZER-ISC-V1 software with web and mobile APP, offering six functions: scene management, scheduling, energy metering, fault alarms, lifetime prediction, and role-based access.

Core feature list:

  1. Scenes: one-button switch among training/match/broadcast/concert/cleaning/security/closed, each scene defining loop brightness;
  2. Schedules: automatic dispatch by weekday/weekend/holiday;
  3. Daylight harvesting: window zones dim artificial lights when natural light is sufficient;
  4. Occupancy sensing: corridors, restrooms, garages dim to 10% when empty, rise to 满功率 when occupied;
  5. Energy metering: D4i fixtures report real-time power; platform generates daily/weekly/monthly reports vs history;
  6. Fault alarms: offline, over-temperature, short circuit trigger pop-up + SMS + APP push;
  7. Lifetime prediction: estimates remaining life from burn hours and decay curves;
  8. Fire linkage: on fire alarm, all general lighting forces off, emergency lighting forces on, exit signs fully lit;
  9. Role-based access: venue manager, operations, cleaning, maintenance each have limited permissions;
  10. Third-party integration: BACnet/IP, Modbus TCP, SNMP API for BAS, DCIM, smart venue platforms.

4.4 Scene Design Example: A Comprehensive Gymnasium

For a 3,000-seat comprehensive gymnasium, KITOZER typically presets these scenes during commissioning:

Scene Basketball Court Badminton Pool Stands Corridors Parking
Closed security 5% 5% 0% 5% 10% 20%
Morning opening 30% 30% 20% 30% 50% 50%
Daily training 60% 70% 50% 30% 80% 满功率
Official match 满功率 满功率 80% 满功率 满功率 满功率
HD broadcast 满功率 (5600K locked) 满功率 满功率 满功率 满功率 满功率
Concert 80% (with stage lights) off off 满功率 满功率 满功率
Cleaning 40% 40% 30% 20% 50% 50%
Emergency egress off off off emergency on emergency on emergency on

This scene table needs no manual operation; KITOZER-ISC automatically switches based on the venue booking calendar. If the booking system shows a basketball match 7–9pm, the platform rises from training to match mode at 6:45pm, drops to cleaning at 9:15pm, and to security at 10pm.


Chapter 5: Venue-Specific Lighting Design

5.1 Outdoor Football Field Lighting

Outdoor football fields have the highest power, tallest poles, and most complex design. A standard 11-a-side pitch is about 105m×68m; lighting is usually mounted on corner poles or long-side lighting gantries.

Pole layouts:
– Four-corner layout: One pole at each corner with 12–24×1000W floodlights per pole. Fewer poles, lower civil cost; but vertical illuminance may be weak at far corners. Suited to sub-5,000-seat amateur/training pitches.
– Two-long-side layout: Continuous fixtures along the long-side stand roofs or dedicated gantries, 30–60 fixtures per side. Better vertical uniformity and broadcast; but gantry civil cost is high. Suited to professional broadcast venues.
– Hybrid corner + side: Current mainstream for professional stadiums.

Typical 11-a-side amateur training config:
– Target horizontal: 300 lx
– Pole height: 25–30m
– Per pole: 6×400W floodlights
– Poles: 4
– Total power: 4×6×400W = 9.6kW
– Fixtures: KITOZER-KT400W-2026, 40° lens
– Reference cost (×2): RMB 450,000–600,000 (fixtures+poles+cable+foundation+install)

Typical 11-a-side HD broadcast config:
– Target horizontal: 1500 lx
– Gantry height: 40–60m
– Per side: 24×1000W, 48 total
– Total power: 48kW
– Fixtures: KITOZER-KT1000W-2026, 21° lens
– Hoods to suppress spill
– Reference cost (×2): RMB 3.5M–5M

Design notes:
1. Pole positions must avoid camera positions and broadcast truck sightlines;
2. Fixture tilt must be 25°–65° from vertical, avoiding direct glare to players;
3. Uplight ratio (UR) must be <1% per urban nightscape rules;
4. All outdoor fixtures require lightning protection and grounding, pole resistance <10Ω;
5. High-power inrush current requires circuit derating by 1.5×.

5.2 Indoor Basketball Court Lighting

Indoor basketball courts live in gymnasiums, fitness centers, and school sports buildings, typically 7–12m ceiling height.

Layout:
– LED high-bay fixtures in two or four rows along court length;
– Long axis along the court length, beam 60°–90°;
– No visible fixture shadows on the floor.

Typical standard court (28m×15m):
– Target: 300 lx training, 750 lx competition
– Fixtures: KITOZER-HB200W high-bay
– Qty: 12–16
– Mount height: 8m
– Uniformity U1≥0.7
– Reference cost (×2): RMB 30,000–50,000

5.3 Swimming Pool Lighting

Swimming pools are the harshest lighting environment: high humidity (RH>80% year-round), chlorinated corrosion, mirror-like water reflection, fixtures close to water, and electrical safety around water.

Design notes:
1. Fixtures must be IP65+ tri-proof; ordinary panel lights fail within months. KITOZER uses TP series throughout.
2. Anti-glare is especially strict: water acts as a mirror; light reflecting into swimmers’ eyes impairs visibility. Use bat-wing optics or anti-glare louvers, and position fixtures to avoid reflection pools over lanes.
3. Electrical safety: within 2m of water, use SELV 12V/24V or isolation transformers; all metal bodies must be equipotentially bonded.
4. Color rendering: skin tone and lane lines need Ra≥80.
5. Emergency lighting: must cover pool surface, starting blocks, and lifeguard positions.

Typical 50m 8-lane pool:
– Target surface illuminance: 500 lx (competition)
– Fixtures: KITOZER-TP36W tri-proof, 1200mm
– Qty: 40–50 along both long sides
– Mount height: 6–8m above water
– Reference cost (×2): RMB 80,000–120,000

5.4 Badminton Hall Lighting

Badminton is the most demanding indoor sport for lighting, for three reasons: fast shuttlecock speed (up to 400 km/h kill shots), small size (65mm diameter), and low contrast against white ceilings. Any glare makes athletes lose the bird.

BWF-certified requirements:
– Horizontal illuminance: ≥500 lx (competition), ≥750 lx (international)
– Uniformity U1≥0.8
– Glare GR≤30 (UGR<19)
– Fixtures must not be directly above the court (avoid upward glare)
– Fixture rows parallel to the net, so players looking up do not face fixtures

KITOZER standard badminton solution:
– Fixtures: KITOZER-LN1200 linear, UGR<19
– Layout: 6–8 linear lights per standard court (13.4m×6.1m), spaced 1.5–2m along length
– Long axis parallel to net
– Dark ceiling paint to reduce ambient reflection
– Reference cost (×2): RMB 8,000–12,000 per court

5.5 Tennis Court Lighting

Tennis is outdoor or indoor. Outdoor courts use floodlights on side poles; indoor courts resemble badminton but larger (23.77m×10.97m) with higher illuminance (750–1000 lx competition).

Typical outdoor court:
– Six 200W floodlights on side poles, three per side
– Pole height 8–12m
– Target 300–500 lx
– Poles positioned to avoid shadows behind baselines

5.6 Underground Parking

Parking is the energy-saving focus of venue ancillary lighting. Traditional tubes run 24/7; a 100-space garage can burn RMB 50,000–80,000/year. KITOZER solution:

  • Fixtures: KITOZER-TP18W LED tri-proof tubes (or integrated fixtures)
  • Control: built-in microwave radar occupancy sensor per fixture
  • Strategy: vehicle/person triggers 满功率 (36W); after leaving, delay 30s then drop to 10% (~4W)
  • Savings: 60–70% vs always-on
  • Lane illuminance: ≥30 lx, parking spaces ≥20 lx
  • Reference cost (×2): RMB 150–250 per space

5.7 Offices, Corridors, Athlete Housing

Ancillary offices, athlete housing, lounges, corridors follow GB 50034 general building lighting:

  • Offices: 300–500 lx, PL6060 panels
  • Meeting rooms: 300 lx, motorized blinds and scene panels
  • Corridors: 100 lx, occupancy control
  • Stairwells: 100 lx, emergency lights always on
  • Athlete dorms: 200 lx, bedside dimmable
  • Canteens: 200 lx, 4000K

Chapter 6: Data Center and Compute Facility LED Lighting

6.1 Why Data Center Lighting Is a Separate Category

Although not a sports venue, data centers, compute containers, and edge rooms often share industrial parks with gymnasiums and exhibition halls. They also have unique lighting requirements that ordinary building lighting standards do not cover:

  1. 24×7 uninterrupted operation: fixture life must be ≥50,000h;
  2. Inspection mode + occupancy linkage: operators are absent 95% of the time, so lights should not be fully on, but 5–10% patrol must remain;
  3. Hot/cold aisle zoning: separate control for cold and hot aisles;
  4. DCIM integration: lighting faults must report to DCIM; fire alarm must link;
  5. Status indication: rack PDU, distribution cabinet, UPS panels need status lights without glare interfering with meter reading;
  6. Emergency egress: data center evacuation must complete within 90 seconds; emergency lighting must cover every rack row and exit.

6.2 KITOZER Standard Data Center Lighting

Zone Fixture Type Typical Power Illuminance Control Strategy
Cold aisle room LED strip/panel 36W 200 lx (ops face) occupancy + 10% patrol
Hot aisle room LED strip 36W 100 lx occupancy
Row PDU area LED downlight 15W 300 lx (meter face) on/dim
Ops corridor LED linear 18W 100 lx occupancy
Corridor/lobby LED panel 36W 200 lx schedule + daylight
UPS/battery room LED tri-proof 36W 200 lx on + emergency
Control center panel + strip 36W/m 500 lx (desk) scene panel
Egress emergency + exit 3–5W floor ≥1 lx emergency always

6.3 Occupancy-Linked Energy Logic

The core of data center lighting savings is not swapping LEDs (LED is just the prerequisite) but “dim when nobody is here.” KITOZER strategy in the server room:

  • Fixtures built with 24GHz microwave radar (not PIR, which triggers falsely from server heat);
  • Operator enters cold aisle, radar detects and that row rises to 满功率;
  • On exit, after 5-minute delay, drops to 10% patrol;
  • Patrol keeps fixtures on (not off) at 10%, so entry triggers instant full brightness;
  • DALI-2 dimming >1.5 kHz, no electromagnetic interference to servers.

Field measurements in a 5,000㎡ data center: traditional fluorescent 24×7 used ~280,000 kWh/year; KITOZER smart LED + occupancy uses ~60,000 kWh/year, a 78% saving.

6.4 Emergency Lighting and Fire Linkage

Data centers have stringent fire safety. Once gas suppression (FK-5-1-12 / IG541) discharges, all personnel must evacuate within 30 seconds. Therefore:

  • Escape corridor floor minimum ≥1 lx, stairwell ≥5 lx;
  • Emergency duration ≥90min;
  • Fire alarm dry contact links to the lighting controller: all general lighting off, emergency lighting fully on;
  • Emergency lights have self-contained batteries, independent of the main EPS, so they work even if the lighting distribution box burns.

KITOZER-EPS20K-2026 in data center projects: 20kVA/30–60min, 27×12V100Ah batteries, float-charged on mains, 0.25s switchover to inverter on outage.


Chapter 7: Electrical Design — Circuits, Drivers, Redundancy, and Emergency Power

7.1 Lighting Distribution Architecture

A complete venue lighting system from utility incoming to fixture terminals usually has four levels:

Level 1: Outdoor/venue main distribution cabinet
– Tapped from the 0.4kV secondary side of the 10kV/0.4kV transformer
– Main MCCB with leakage and shunt trip
– Feeds sub-panels by area

Level 2: Lighting distribution box (floor/zone)
– KITOZER-PDX outdoor floor-standing or KITOZER-KZX indoor wall-mounted
– Each box: main switch, branch MCBs, DALI power module, relay module, 0-10V dimming module
– Each branch protected by 16A/20A RCBO (30mA)

Level 3: Fixture drivers
– Each high-power floodlight has an external waterproof driver (IP67)
– Indoor drivers internal or centralized in the distribution box
– Constant-current output matched to LED string configuration

Level 4: Fixture itself
– LED board + lens + heat sink

7.2 Circuit Design Principles

  1. Loop loading ≤80% of rating. A 16A/220V loop theoretically carries 3,520W; practical loading ≤2,800W.
  2. Separate loops by function: playing area, stands, corridors, parking each on their own loop, so maintenance does not affect other zones.
  3. Emergency lighting on independent loops from dedicated EPS bus, never shared with general lighting.
  4. Fixtures per loop: a 16A loop can feed at most two 1000W floodlights or 40×36W panels.
  5. Neutral conductor sizing: LED switching power supplies generate third harmonics; neutral current can reach 1.5× phase current, so upsize neutral (e.g., phase 4mm² → neutral 6mm²).
  6. Three-phase balance: distribute fixtures evenly across L1/L2/L3.

7.3 Cable Selection

KITOZER venue project cable specs:

Use Spec Notes
Outdoor main YJV22-4×300+1×150 armored, direct burial or tray
Floor main WDZB1-YJY-4×25+1×16 low-smoke halogen-free B1
Emergency branch WDZN-YJY-3×6 fire-resistant
General branch WDZ-YJY-3×4 LSZH flame-retardant
DALI bus ZC-RVVP-2×1.5 shielded twisted pair
Outdoor pole conduit HDPE75 cable protection
Indoor conduit JDG20 galvanized steel fire-rated

7.4 EPS Emergency Power Design

Occupancy-dense venues (gymnasiums, pools, exhibition halls, large malls) must have EPS. KITOZER typical configuration:

KITOZER-EPS20K-2026 (20kVA single/three-phase)
– Rated capacity: 20kVA
– Input: AC 220V/380V ±20%, 50Hz
– Output: AC 220V/380V, regulation ±3%
– Switchover: ≤0.25s
– Backup: ≥60min (full load)
– Batteries: 27×12V100Ah
– Charging: smart three-stage
– Comms: RS485/Modbus, to environmental monitoring
– Dimensions: floor cabinet ~600×800×2000mm
– Reference price (×2): RMB 168,000/set

In normal operation EPS is hot standby: mains directly feeds emergency lighting loops while float-charging batteries; on outage, static transfer switches within 0.25s to inverter output, batteries inverted to 220V AC. The transition is nearly invisible.

7.5 Lightning Protection and Grounding

Outdoor poles, floodlights, and high-mast lights require lightning protection:

  • Per pole base: ground rods (∠50×5 hot-dip galvanized angle, 2.5m, 2–3 rods)
  • Resistance ≤10Ω (≤1Ω on shared ground)
  • Fixture body bonded to pole with BV-6mm² green-yellow wire
  • SPD on each incoming circuit: Class B 10/350μs Iimp≥12.5kA, Class C 8/20μs In≥20kA
  • KITOZER floodlights have built-in 10kV line-earth surge protection

Chapter 8: Installation and Commissioning

8.1 Construction Workflow

A venue lighting project from mobilization to acceptance typically follows:

  1. Detailed design: DIALux point-by-point modeling from architectural drawings; produce fixture layout, power system diagram, control diagram;
  2. Material delivery: fixtures, distribution boxes, cables, poles arrive; batch inspection of model, power, CCT, optics;
  3. Conduit embedding: embed conduits, junction boxes, pole foundation bolts with civil works;
  4. Pole/gantry erection: outdoor poles segmented lifting; concrete foundation cured ≥14 days; indoor catwalks and cable trays;
  5. Cable pulling: trays installed, cables pulled; DALI control cables in separate conduit from power to avoid interference;
  6. Fixture installation: outdoor floodlights on poles, indoor fixtures on ceiling; do not wire until conduit tests pass;
  7. Distribution box wiring: outdoor floor boxes and indoor wall boxes in place; breakers, relays, DALI modules installed;
  8. Power-on test: energize loop by loop; check insulation resistance (≥0.5MΩ), phase sequence, RCD trip;
  9. Comm test: DALI bus addressing; confirm every lamp is recognized by gateway;
  10. Dimming/scene test: software dimming loop by loop, scene switching, verify brightness response;
  11. Fire linkage test: simulate fire alarm, confirm emergency lights on, general lights off;
  12. Illuminance measurement: third-party lab measures horizontal/vertical illuminance point-by-point, issues report;
  13. 72-hour trial run: system runs 72 hours fault-free;
  14. Training and handover: train venue operations staff; deliver as-built drawings, O&M manual, warranty card.

8.2 Installation Best Practices

Outdoor floodlight on pole:
– Top mounting frame must be level; bracket angle adjustable ±30°;
– Number each fixture on the pole to match circuit and DALI address; label;
– Power cable runs inside the pole, never exposed;
– Threadlocker on all bolts; re-torque before typhoon season;
– Factory burn-in 4 hours before shipment; no bulk on-site re-burn.

Indoor panel installation:
– 600×600 panels embed in gypsum ceiling; verify grid load rating;
– Heavy fixtures (>3kg) must be anchor-bolted to the slab, not hung on ceiling grid;
– Keep ≥200mm clearance from AC vents and sprinklers.

Swimming pool tri-proof:
– Cable entry faces down to prevent condensate from running into the fixture;
– Each fixture independently suspended, no shared trunking;
– Fixture-to-water distance ≥2.5m.

8.3 DIALux Illuminance Calculation

KITOZER always runs DIALux evo in bid stage:

  1. Import CAD plan, build 3D model;
  2. Enter field dimensions, ceiling height, wall reflectance (wall 0.5, floor 0.3, ceiling 0.7);
  3. Select fixtures from KITOZER photometric database (IES files provided by KITOZER);
  4. Place fixtures per layout;
  5. Set target illuminance and measurement planes (playing plane, 1.5m vertical);
  6. Run calculation, generate false-color maps and numeric reports;
  7. Tune positions, power, optics until uniformity meets spec;
  8. Output PDF report as bid technical attachment.

8.4 Common Commissioning Issues

Symptom Cause Fix
One lamp dark loose wiring / DALI address conflict check terminals, re-address
Dimming flicker low driver frequency / poor ripple high-frequency driver, add filter cap
DALI intermittent reversed bus polarity / no terminator check polarity, add 10kΩ end-of-line resistor
Poor uniformity fixture placement error / wrong optic on-site aim, add fill lights
Fixture over-temp poor thermal interface / high ambient clean fins, check installation
Dark corners narrow optic add fill or wider optic
Water reflection glare fixtures facing lanes re-aim, avoid reflection zone

Chapter 9: Energy Savings and ROI Calculation

9.1 Why Venue Lighting Retrofit Must Calculate ROI

Many owners ask only “how much to swap to LED,” not “how many years to pay back.” In practice, venue lighting is among the fastest-payback energy retrofits — typically 2.5–4 years, after which pure savings. This chapter works through a complete case.

9.2 Case: A 5,000㎡ Comprehensive Gymnasium Retrofit

Background:
– Building area: 5,000㎡
– Contains: 1 basketball court, 4 badminton courts, 1 pool, 1 gym, 200㎡ offices, 300㎡ corridors, 800㎡ underground parking (~50 spaces)
– Original: mixed MH + fluorescent, total installed ~85kW
– Operating: 14h/day (6:00–22:00), 365 days
– Tariff: commercial 0.85 RMB/kWh
– Original annual lighting bill: 85kW × 14h × 365 × 0.85 ≈ RMB 370,000/yr

KITOZER third-gen smart LED retrofit:

Zone Original Source Orig. Power KITOZER New Fixture New Power Savings
Basketball 1000W MH ×8 8kW HB200W high-bay ×12 2.4kW 70%
Badminton 400W MH ×16 6.4kW LN1200 linear ×32 1.15kW 82%
Pool 400W tri-proof MH ×20 8kW TP36W tri-proof ×40 1.44kW 82%
Gym 250W MH ×12 3kW HB100W ×10 1kW 67%
Office 36W troffer ×40 1.6kW PL6060 ×40 1.44kW 10%
Corridor 36W tube ×60 2.2kW LN1200 sensor ×60 1.08kW 50%
Garage 36W tube ×100 3.6kW TP18W radar sensor ×100 1.8kW 50%
Outdoor plaza 400W HPS ×12 4.8kW KT200W floodlight ×12 2.4kW 50%
Emergency/signs — 0.5kW EM series 0.3kW 40%
Total ~38kW actual avg ~12.9kW actual avg (with smart dimming) ~66%

Note: “New power” is the actual average running power, not installed nameplate. Smart dimming, occupancy sensing, and scheduling mean fixtures do not run at full power 24 hours. For example, garage radar sensors drop to 10% when empty, so actual average power is only ~30% of nameplate.

Annual electricity comparison:
– Before: 38kW × 14h × 365 × 0.85 = RMB 165,000 (actual bill, not theoretical installed)
– After: 12.9kW × 14h × 365 × 0.85 = RMB 56,000
– Annual saved: ~109,000 kWh, ~RMB 109,000

One-time investment (×2 reference):

Item Amount (RMB)
All LED fixtures ~280,000
KITOZER-ISC-V1 smart control 152,000
20kVA EPS 168,000
Distribution/trays/cable 80,000
Installation/commissioning 60,000
Removal of old lights 10,000
Total ~750,000

Payback:
– One-time: RMB 750,000
– Annual electricity saved: RMB 109,000
– Annual relamping saved (old MH relamped every 3 yr, ~30k each time): RMB 10,000
– Annual total benefit: ~RMB 119,000
– Static payback: 750,000 / 119,000 ≈ 6.3 years

That looks long, but it includes EPS (168k) and smart control (152k), which are “non-pure-savings” investments. If counting only pure lighting+control (excluding EPS, which is a mandatory fire/safety item anyway):

  • Fixtures + control + distribution + install: ~RMB 500,000
  • Annual benefit: RMB 119,000
  • Payback: ~4.2 years

For a 30-year gymnasium, 4-year payback with 26 years of pure savings is an excellent investment. LED life of 100,000 hours at 14h/day means 20 years without relamping, saving enormous maintenance labor.

9.3 General ROI Formula

KITOZER provides free customized ROI reports with DIALux simulations and side-by-side comparisons.


Chapter 10: Project Case Studies

10.1 Case 1: University Gymnasium LED Retrofit (completed 2025)

Overview:
– Location: Guangdong Province, China
– Venue: 5,000-seat comprehensive gymnasium
– Before: built 2010, MH lighting, frequent failures, uneven illumination
– Retrofit: full KITOZER smart LED system

Bill of materials:
– KITOZER-HB200W high-bay: 48 (competition area)
– KITOZER-LN1200 linear: 80 (training hall)
– KITOZER-TP36W tri-proof: 60 (swimming pool)
– KITOZER-PL6060 panel: 120 (office/corridor)
– KITOZER-KT200W floodlight: 24 (outdoor training)
– KITOZER-ISC-V1 smart control: 1 set
– KITOZER-EPS10kVA: 1 set
– Smart wall panels: 16

Results:
– Horizontal illuminance from average 320 lx to competition mode 1,200 lx
– Uniformity from 0.5 to 0.75
– Annual electricity from RMB 420k to RMB 150k
– Payback ~3.8 years

10.2 Case 2: District Fitness Center (new build 2026)

  • Location: Guangdong
  • New venue: basketball, badminton, swimming, gym, parking
  • Full KITOZER third-gen smart LED

Highlights:
– Badminton UGR<19, passing BWF preliminary certification
– DALI-2 single-fixture control, one-tap scenes via mobile APP
– Garage microwave radar occupancy: lights on on approach, dim after exit
– Integrated with venue booking system, automatic lighting scheduling by class timetable

10.3 Case 3: Industrial Park Outdoor Football Pitches (2026)

  • Two 5-a-side pitches
  • Each pitch: four 15m poles, 4×KITOZER-KT200W per pole
  • Target 200 lx (amateur training)
  • Night schedule: full on 18:00–23:00, drop to 30% security after 23:00
  • Reference cost (×2): ~RMB 280k

10.4 Case 4: Data Center Server Room Smart Lighting (2026)

  • Server room 3,000㎡, zoned cold/hot aisle
  • 240×KITOZER-TP36W tri-proof strips with built-in 24GHz radar
  • DALI-2 integrated into DCIM, SNMP reporting
  • Occupancy: 10% patrol when empty, 满功率 on entry
  • Annual lighting bill from RMB 180k to RMB 45k

Chapter 11: Selection Guide — How to Choose KITOZER Fixtures

11.1 Selection Decision Tree

Owners can follow this decision tree:

Step 1: Determine venue type and use class
– Outdoor football/athletics → floodlight series (KT1000W/600W/400W)
– Indoor basketball/volleyball/handball → high-bay series (HB200W/150W/100W)
– Badminton/table tennis → linear series (LN1200)
– Pool/shower/garage → tri-proof series (TP36W/18W)
– Office/meeting/corridor → panel series (PL6060/12060)
– Egress/stairs → emergency series (EM5W/EX3W)

Step 2: Determine illuminance class
– Recreation 200–300 lx
– Amateur training 300–500 lx
– Official competition 750–1000 lx
– HD broadcast 1400–2000 lx

Step 3: Match power to mounting height
– Height <6m: 36W–100W panel/high-bay
– Height 6–12m: 100W–200W high-bay
– Height 12–25m: 200W–400W floodlight
– Height 25–60m: 400W–1000W floodlight

Step 4: Choose control method
– Tight budget / retrofit: 0-10V group dimming
– New build / smart requirement: DALI-2 single-fixture
– Finished interior / no re-wire: Zigbee wireless
– Outdoor wide-area poles: LoRa

Step 5: Choose emergency approach
– Small venues: self-contained emergency battery per fixture (3–5W)
– Medium/large: centralized EPS cabinet

11.2 Budget Tier Configurations

Economy tier (~RMB 150–250/㎡):
– LED fixtures (domestic chips, 110 lm/W)
– 0-10V group dimming
– Self-contained emergency per fixture
– For: community gyms, company courts
– Life: L70≥30,000h

Standard tier (~RMB 300–500/㎡):
– KITOZER main fixtures (130 lm/W, Ra≥80)
– DALI-2 group control
– Centralized EPS
– For: district fitness centers, school gyms
– Life: L70≥50,000h
– Warranty: 5 years

Professional tier (~RMB 600–1000/㎡):
– KITOZER premium floodlights (150 lm/W, R9>50)
– DALI-2 single-fixture + D4i energy telemetry
– Dual supply + EPS
– DIALux simulation + third-party acceptance
– For: municipal sports centers, broadcast-capable venues
– Life: L70≥100,000h
– Warranty: 8 years

11.3 Common Selection Mistakes

  1. Looking only at power, not efficacy: same 100W, 100 lm/W = 10,000 lm; 150 lm/W = 15,000 lm — 50% brightness difference.
  2. Ignoring uniformity: measuring only center illuminance, missing dark corners.
  3. Cheap drivers: 90% of LED failures are drivers; do not skimp.
  4. No dimming headroom: running fixtures at 满功率 accelerates decay. KITOZER recommends 400W fixtures run at 300W for 25% headroom.
  5. Ignoring glare: caring only about brightness, not glare; athletes complain they cannot see the ball.
  6. No DIALux simulation: installing by experience, then reworking when illuminance is wrong.

Chapter 12: Frequently Asked Questions (40)

Q1: How much do KITOZER LEDs save vs traditional MH?
A: In a typical comprehensive gymnasium, third-gen smart LED saves 60–75% vs MH. About 40–50% comes from LED efficacy, another 20–30% from smart dimming, occupancy, and scenes. Exact savings depend on operating hours and tariff.

Q2: Is 100,000-hour LED life real?
A: KITOZER outdoor floodlights are rated L70≥100,000h at Ta=25°C per IES TM-21. Actual life depends on ambient temperature, thermal interface, and driver quality. KITOZER offers 8-year warranty with ≤20% decay.

Q3: DALI vs 0-10V — which is better?
A: 0-10V is analog, one voltage = one brightness, group-only, no per-fixture addressing. DALI is a digital bus with per-fixture addresses, individual dimming, and fault reporting. DALI costs 30–50% more but is far more capable. New builds: DALI. Budget retrofits: 0-10V.

Q4: Is EPS mandatory for venues?
A: Per GB 51309, occupancy-dense public buildings (gymnasiums, pools, large fitness centers) must have fire emergency lighting. Small venues can use self-contained battery fixtures; medium/large should use centralized EPS. KITOZER configures to local fire acceptance.

Q5: Can LED floodlights survive typhoons?
A: KITOZER outdoor fixtures pass IK08; poles are designed to local basic wind pressure (Guangdong coast typically 0.7 kN/㎡). Flange bolts and brackets are checked to Category 12 winds. We recommend re-inspecting bolts before typhoon season.

Q6: Why can’t pools use ordinary LED panels?
A: Pool air RH>80% with chlorinated vapor; ordinary IP40 panels leak, rust, and short within months. IP65 tri-proof (KITOZER TP series) with PC/ABS anti-chloride housing is required.

Q7: Does low dimming cause flicker?
A: KITOZER uses DALI-2 high-frequency constant-current drivers at >1.5 kHz; no visible flicker even at 1%. Cheap LEDs flicker below 10%, visible on high-speed cameras. KITOZER fixtures meet 50fps–240fps broadcast.

Q8: Why no spotlights in badminton halls?
A: Spotlights are point sources that enter athletes’ upward field of view, causing severe glare and temporary blindness tracking high shots. Badminton requires large-area, low-luminance, UGR<19 linear/panel fixtures.

Q9: How many lights on a football pitch?
A: Depends on class. Amateur training (200–300 lx): 48–64×200–400W; professional match (750 lx): 24–32×1000W; HD broadcast (1500 lx): 48–64×1000W. Exact count requires DIALux.

Q10: Is CRI Ra80 enough?
A: For training/recreation, yes. HD broadcast requires Ra≥80 and R9>5; 4K/slow-mo requires Ra≥90, R9>50. KITOZER floodlights default Ra≥80/R9≥5; high-CRI R9>50 versions available.

Q11: KITOZER warranty?
A: Standard 5 years; outdoor floodlights 8 years (≤20% decay). Non-manufacturing defects replaced free. Warranty starts on site delivery.

Q12: What fraction of total cost is installation?
A: Fixtures 40–50%, distribution/cable/trays 20%, installation/commissioning 15–20%, smart control + EPS 20–30%.

Q13: Can I just swap the lamp, not the fixture?
A: Not recommended. MH housings were thermally designed for MH and optics differ. Whole-fixture replacement is recommended. Some retrofits keep existing poles and wiring, swapping only heads and drivers.

Q14: Do LEDs start in cold weather?
A: KITOZER fixtures operate -40°C to +55°C. But batteries derate below -20°C; EPS battery cabinets should be in insulated rooms.

Q15: Can the smart system integrate with our existing BMS?
A: Yes. KITOZER-ISC-V1 offers BACnet/IP, Modbus TCP, SNMP, OPC UA to integrate with Honeywell, Johnson, Siemens, Schneider BMS and DCIM platforms.

Q16: How many lamps per DALI bus?
A: One DALI subnet = 64 short addresses. More than 64 requires gateways. KITOZER-DG16 supports 16 subnets = 1,024 lamps.

Q17: Do garage sensors false-trigger?
A: KITOZER uses 24GHz microwave radar, not PIR. It penetrates plastic covers, has adjustable range/angle, and does not false-trigger from hot car engines. Full on on approach, 10% after 30s–5min delay.

Q18: Does LED EMI interfere with broadcast?
A: Qualified drivers pass EMC (GB 17743, EN 55015), well below limits. KITOZER drivers have built-in EMI filters with no perceptible interference to cameras or trucks.

Q19: Cost per badminton court?
A: BWF preliminary standard: 6–8×KITOZER-LN1200 per court (13.4m×6.1m), RMB 8,000–12,000 (×2) including install.

Q20: What CCT for broadcast?
A: International broadcast standard is 5600K±200K. KITOZER offers 4000K/5000K/5700K; broadcast projects default 5700K.

Q21: Is LED repair hard?
A: KITOZER floodlights are modular: LED board, driver, lens each replaceable on site. No need to ship whole fixtures back. Indoor fixtures usually replaced whole.

Q22: Can we keep existing poles in retrofit?
A: Yes. KITOZER surveys pole height, wall thickness, flange size, and supplies adapter brackets. If structural strength is adequate, keeping poles saves major pole/foundation cost.

Q23: Does lighting work require permits?
A: Small retrofits (no added capacity) usually only need internal property management filing. Large new builds or capacity additions require construction and fire filings. KITOZER supports permit drawings and documents.

Q24: Where are KITOZER fixtures made?
A: KITOZER is the own brand of Guangzhou Laian Intelligent System Development Co., Ltd., manufacturing at No. 5 Huashan Road, Shilou, Panyu, Guangzhou, in the Zhongrun Industrial Park Chaotian campus. SMT board assembly, whole-fixture assembly, burn-in, and packaging are all in-house.

Q25: Can you provide third-party test reports?
A: Yes. All main models have CNAS-accredited IES LM-79 optical reports, GB/T 2423 environmental reports, IP ratings, and CCC certificates. Copies with company seal for bids.

Q26: Price of a 1000W floodlight?
A: KITOZER-KT1000W-2026 reference price (×2) ~RMB 7,400/set; hood +RMB 480/set. Volume and long-term partners negotiable.

Q27: Lead time?
A: Standard models (200W/400W floodlights, panels, tri-proof) in stock, 7–15 days. Custom models (1000W special optics, special CCT, custom housing) 25–35 days. Smart control including software 30–45 days.

Q28: Do you install yourselves or subcontract?
A: KITOZER has its own electrical installation crew with electrician and working-at-heights certificates. Within Guangdong province we self-perform; out-of-province we guide local crews or send resident engineers.

Q29: On-site response during warranty?
A: Within Guangdong 48h on-site; out-of-province 72h response. Common spares stocked; replacement parts shipped within 48h.

Q30: Why are you more expensive than Taobao LEDs?
A: Taobao LEDs are indoor general lighting at 80–100 lm/W, IP20, 1-year warranty, no smart control. KITOZER venue lights are engineering-grade: IP66/IP67, IK08, 10kV surge, 130–160 lm/W, 8-year warranty, DALI smart control, DIALux simulation, on-site commissioning. Different product class; cannot compare directly.

Q31: Daily power of one 1000W floodlight?
A: 1000W = 1kW; 10h/day = 10 kWh; at 0.85 RMB/kWh = RMB 8.5/day. A 48-lamp pitch uses ~RMB 408/day, ~RMB 12k/month. Smart dimming greatly reduces actual run time and power.

Q32: UV or light pollution from LEDs?
A: LEDs are cold sources with almost no UV/IR. Glare is controlled by optical design + hoods; KITOZER outdoor floodlights GR≤24, uplight <1%, meeting urban nightscape rules.

Q33: Difference between pool and garage tri-proof?
A: Pool tri-proof requires chlorine corrosion resistance with UV-stabilized PC and silicone gaskets. Garage tri-proof only needs water/dust resistance. KITOZER pool-specific TP36W passes salt fog + chlorine tests.

Q34: Does the smart system work on power outage?
A: On outage, general lights follow mains off; emergency lights run on self-contained batteries; EPS-fed emergency loops invert from battery. The control platform has UPS backup for 15–30 minutes. On mains restoration, the system auto-restarts and returns to preset scenes.

Q35: Can I control venue lights remotely by phone?
A: Yes. KITOZER-ISC-V1 provides iOS/Android APP; off-site managers can check status, dim, and receive alarms. Remote operations require dual-confirmation permissions for safety.

Q36: How many lights per standard basketball court?
A: 28m×15m, 8m ceiling: training (300 lx) ~12×100–150W high-bay; competition (750 lx) ~16–20×200W. Exact count by DIALux.

Q37: Can CCT be changed on site?
A: No. CCT is fixed at LED packaging. KITOZER offers dual-CCT (3000K/5000K) tunable fixtures, but this must be specified at order time.

Q38: Can the venue stay open during retrofit?
A: Yes, by zone. KITOZER typically works nights (after 22:00 closing, before 6:00 opening), not affecting daytime operations. Total retrofit 2–4 weeks.

Q39: Do you provide design drawings?
A: Yes. KITOZER engineering provides free DIALux reports, fixture layouts, power system diagrams, and control schematics for bid-stage clients. Detailed construction drawings after scheme approval.

Q40: How to get a KITOZER quote?
A: Call +86 18520668845 / +86 13922289957 (WeChat same numbers), or WhatsApp +86 19068534140. Visit www.lain.com.cn (Chinese) or www.gdlain.com (English). Provide venue area, ceiling/pole height, illuminance class, and use case; we return a preliminary scheme and reference quote within 24 hours.


Chapter 13: Packaging, Delivery, Warranty, and Company Information

13.1 Packaging and Shipping

All KITOZER LED fixtures burn-tested for 4 hours before shipment, with each lamp checked for color, brightness, and appearance. Packaging:

  • Fixtures: pearl cotton + corrugated carton, fragile labels
  • Floodlights (1000W/400W): wooden crates with foam fixation
  • Distribution boxes / EPS cabinets: bare + stretch wrap on wooden pallets, forklift-ready
  • Smart control gear: anti-static bag + foam + carton
  • Each carton labeled: model, qty, gross weight, destination, handling notes

Shipping:
– Within Guangdong: dedicated van, 1–2 days
– Domestic: dedicated freight line, 3–7 days
– Export: FOB Guangzhou/Shenzhen, sea/air per customer

13.2 Delivery Documentation

Each shipment includes:
1. Packing list (3 copies)
2. Product certificate
3. Third-party test report copies
4. Installation and operation manual (Chinese/English)
5. Warranty card
6. Electrical and system diagrams (electronic)

13.3 After-Sales and Warranty

Category Warranty Coverage
Outdoor floodlights 8 years non-manufacturing defects, ≤20% decay
High-bay/panel 5 years non-manufacturing defects
Tri-proof lights 5 years non-manufacturing defects
Emergency/exit 3 years (battery 1 year)
Smart control system 3 years hardware + software
EPS 3 years (battery 1 year)
Distribution cabinets 2 years

During warranty:
– Free replacement of defective products (including freight)
– 48h phone response
– On-site within Guangdong in 48h
– Free software upgrades (same version)

After warranty:
– Cost-price spares
– Lifetime maintenance

13.4 Why Choose KITOZER

  • Own factory: Panyu Guangzhou base, from SMT to whole-fixture assembly in-house, no ODM relabeling
  • Engineering experience: hundreds of data center, sports venue, smart park lighting projects
  • One-stop delivery: fixtures + control + distribution + emergency + install + commissioning + training under one contract
  • Dual-site service: lain.com.cn for domestic, gdlain.com for export
  • Rapid response: 7×12h technical support, instant WhatsApp

13.5 Contact Information

Company: Guangzhou Laian Intelligent System Development Co., Ltd.
Brand: KITOZER
Address: Zhongrun Industrial Park Chaotian Campus, No. 5 Huashan Road, Shilou, Panyu, Guangzhou, China
Phone: +86 20-XXXXXXX
Mobile: +86 18520668845 / +86 13922289957 (WeChat same)
WhatsApp: +86 19068534140
Chinese website: https://www.lain.com.cn
English website: https://www.gdlain.com
Hours: Mon–Sat 9:00–18:00

13.6 Get Your Venue Lighting Plan

If you are planning a new venue, retrofitting an existing one, or want a reference quote, contact the KITOZER engineering team. Prepare the following, and we will return a preliminary scheme with DIALux simulation within 24 hours:

  1. Venue type (football/basketball/swimming/badminton/comprehensive)
  2. Field dimensions, ceiling height or pole height
  3. Desired illuminance class (training/competition/broadcast)
  4. Whether TV broadcast is required
  5. Existing lighting condition (for retrofit)
  6. Project location (for freight and local codes)

Call: +86 18520668845 / +86 13922289957 (WeChat same)
WhatsApp: +86 19068534140
Visit: www.lain.com.cn | www.gdlain.com


This article is a KITOZER brand technical encyclopedia for reference only. Specific project parameters and prices are subject to detailed drawings and formal contracts. KITOZER reserves the right to update product specifications without prior notice.


附录A:LED照明光学与热学深度技术

A.1 LED光源的发光原理与封装结构

要真正理解KITOZER场馆LED灯具为什么能做到130—160lm/W的高光效,必须从LED芯片的发光原理说起。LED(Light Emitting Diode,发光二极管)是一种固态半导体器件,核心是PN结。当电流通过PN结时,电子与空穴在有源层复合,以光子的形式释放能量。光子的波长(也就是颜色)由半导体材料的禁带宽度决定:氮化镓(GaN)基材料发出蓝光,蓝光经过黄色荧光粉(YAG:Ce)转换,一部分蓝光被吸收并重新发射为宽谱黄光,蓝光与黄光混合就得到了人眼感知的白光。

一颗白光LED灯珠的典型封装结构从下到上依次是:蓝宝石衬底(约100μm厚)、GaN外延层(含N型层、多量子阱有源层、P型层)、电极、硅胶透镜、黄色荧光粉层。KITOZER选用的灯珠来自行业主流供应链,单颗灯珠功率约0.5W—3W,光效在实验室条件下可达200lm/W以上;但整灯光效要扣除透镜损耗(约5%—8%)、驱动电源损耗(约8%—10%)、散热导致的光效衰减(约5%—10%),最终整灯光效130—160lm/W已经是工程上的高水平。

A.2 配光曲线与IES文件

每一款LED灯具出厂前都要在分布光度计(goniophotometer)里测量,生成一份IES(Illuminating Engineering Society)格式的配光数据文件。这份文件记录了灯具在各个空间角度上的发光强度分布,是DIALux照明设计软件的输入。KITOZER为每一款灯具提供标准IES文件,设计师在DIALux里导入后,软件就能精确预测灯具安装后地面上的照度分布。

配光曲线通常用极坐标图表示:圆心是灯具,径向距离是发光强度(cd),角度是空间方位。不同光束角的灯具配光曲线形状完全不同:14°窄光束像一根手电筒光柱,集中在很小的角度范围内;60°宽光束像一把打开的折扇,覆盖大面积。KITOZER 1000W投光灯提供四种可换透镜,就是为了让设计师在同一个灯杆上混合使用不同配光:远角用窄光束把光送到场地远端,近角用宽光束补亮看台下方。

A.3 散热设计为什么决定LED寿命

LED灯珠本身的电光转换效率约40%—50%,也就是说输入功率中有一半以上变成了热量,而不是光。这些热量如果不能及时从芯片导出去,芯片结温Tj会迅速升高。研究表明,Tj每升高10℃,LED的光衰速度大约加快一倍;当Tj超过105℃时,荧光粉会快速黑化,硅胶透镜会发黄,整灯寿命可能从10万小时骤降到2万小时。

KITOZER投光灯的散热路径是:LED灯板(铝基板)→导热硅脂→压铸铝散热壳体→鳍片对流→空气。为了降低热阻,KITOZER采取了几项措施:第一,灯板用2.0mm厚铝基板,铜箔厚度2oz,减少板上热阻;第二,灯板与壳体之间涂导热系数≥3W/m·K的导热硅脂,厚度控制在0.1mm以内;第三,壳体采用压铸铝合金ADC12,鳍片镂空设计,利用自然对流带走热量;第四,关键灯板位置预埋热电偶,配合驱动电源的过温降额功能——当壳体温度超过85℃时,驱动自动降低输出电流,保护灯珠。

A.4 驱动电源的关键指标

驱动电源是LED灯具的”心脏”,也是故障率最高的部件。KITOZER在选型时重点考察以下指标:

  • 效率:驱动本身也耗电,效率90%意味着10%的输入功率变成热量。高效率驱动发热小、寿命长。
  • 功率因数PF:PF≥0.95意味着对电网谐波污染小,不需要额外加装无功补偿装置。
  • 总谐波失真THD:THD<10%,避免干扰场馆音响、转播设备。
  • 输出纹波:纹波电流<5%,否则会产生可见频闪。
  • 保护功能:输出过压、过流、短路、开路保护,防雷浪涌。
  • 工作温度:驱动自身能在-40℃—+70℃稳定工作。
  • 寿命:电解电容寿命决定驱动寿命,KITOZER选用105℃长寿命电解电容,设计寿命≥50,000h。

A.5 眩光控制的工程方法

眩光是场馆照明投诉最多的问题。控制眩光有四种工程手段:

  1. 限制灯具亮度:用小功率灯珠阵列+扩散透镜,而不是单颗大功率灯珠直出。
  2. 控制遮光角:灯具出光口与水平线的夹角(遮光角)≥30°,让人在正常视角下看不到灯珠。
  3. 加装遮光罩:KITOZER-PJ1000遮光罩把上射光和侧射光切掉,只保留向下的有效光。
  4. 合理选择安装位置:灯具不要装在运动员仰视的正上方,要偏侧布置。

A.6 照度均匀度的数学定义

GB/T 35265定义了两个均匀度指标:

  • U1 = Emin / Eavg:最低照度与平均照度之比,反映最暗区域的照明水平。
  • U2 = Emin / Emax:最低照度与最高照度之比,反映最暗与最亮之间的反差。

专业比赛要求U1≥0.7、U2≥0.5。DIALux计算时会在测量面上生成一个等照度网格(通常1m×1m一个测点),逐点计算后输出Emin、Emax、Eavg,再算出U1和U2。


附录B:典型场馆照明计算实例

B.1 实例:一片标准室外网球场

已知条件:
– 场地尺寸:23.77m×10.97m(双打)
– 目标水平照度:300lx(业余训练)
– 灯杆高度:12m
– 灯杆位置:场地长边两侧,每侧两根灯杆
– 灯具:KITOZER-KT200W-2026,光通量24,000lm,光效120lm/W

估算过程:
1. 场地面积 = 23.77 × 10.97 ≈ 261㎡
2. 所需总光通量 = 目标照度 × 面积 × 利用系数 × 维护系数
– 利用系数(CU)取0.6(室外投光,无墙面反射)
– 维护系数(MF)取0.7(户外积灰,3年清洗一次)
– 所需光通量 = 300 × 261 / (0.6 × 0.7) ≈ 186,000lm
3. 所需灯具数 = 186,000 / 24,000 ≈ 7.75盏,取8盏
4. 布置:每侧两根灯杆,每杆2盏,共8盏
5. 实际安装后DIALux复测,根据实际云图微调角度

B.2 实例:一片室内标准篮球场

已知:
– 场地:28m×15m=420㎡
– 目标:300lx训练级
– 顶棚高度:8m
– 灯具:KITOZER-HB200W工矿灯,26,000lm

估算:
– 所需光通量 = 300 × 420 / (0.7 × 0.8) ≈ 225,000lm(室内有墙面反射,CU取0.7,MF取0.8)
– 灯具数 = 225,000 / 26,000 ≈ 8.6盏,取12盏(留余量保证均匀度)
– 布置:沿长边两排,每排6盏,间距4m

B.3 实例:50m标准游泳馆

已知:
– 水面:50m×25m=1,250㎡
– 目标水面照度:300lx(训练)
– 灯具:KITOZER-TP36W三防灯,4,320lm

估算:
– 泳池环境CU较低(水面反射吸光),取0.5;MF取0.75
– 所需光通量 = 300 × 1,250 / (0.5 × 0.75) = 1,000,000lm
– 灯具数 = 1,000,000 / 4,320 ≈ 231盏
– 实际工程中沿两侧纵向布置约50—60盏大功率三防灯,配合蝙蝠翼配光,避免水面反射眩光


附录C:场馆照明验收检测方法

C.1 检测依据与工具

竣工验收时,业主通常委托第三方检测机构(如当地建筑科学研究院、体育设施检测中心)按照GB/T 35265进行现场检测。主要工具包括:

  • 照度计:精度Class A,每年校准,探头带cos校正
  • 亮度计:测量灯具表面亮度,用于眩光计算
  • 色温计/光谱仪:测量现场色温与显色指数
  • 卷尺/激光测距仪:测量测点位置
  • 三脚架:固定照度计探头高度

C.2 测点布置

  • 水平照度测点:在比赛平面上按2m×2m网格布点,覆盖整个比赛区域及缓冲区
  • 垂直照度测点:在场地中心、四个摄像机方向各设测点,探头高度1.5m
  • 看台照度:在观众席前排、中排、后排各测一点
  • 应急照度:在疏散通道地面、楼梯间、出口处测

C.3 检测流程

  1. 灯具全部点亮,稳定燃烧30分钟后开始测量
  2. 先测水平照度,逐点记录
  3. 再测垂直照度,旋转探头对准四个摄像机方向
  4. 测量灯具表面亮度,计算GR眩光指数
  5. 抽测3—5盏灯的色温与显色指数
  6. 断电测试应急照明切换时间和持续时间
  7. 出具检测报告,附测点布置图和数值表

C.4 常见不合格项与整改

不合格项 原因 整改措施
水平照度不足 灯具功率不够/数量少 补灯或换大功率
均匀度差 灯位不对称/角度偏 现场微调灯具角度
垂直照度不达标 灯具安装方向不对 调整俯仰角
眩光超标 遮光角不够 加装遮光罩
色温不一致 不同批次灯珠混装 统一批次更换
应急时间不足 电池老化/EPS容量小 更换电池/扩容

附录D:场馆照明运维管理手册

D.1 日常巡检

场馆物业应建立照明巡检制度,建议:

  • 每日:开馆前目视检查主要灯具是否点亮,有无闪烁、异响
  • 每周:检查配电箱有无异味、温升,记录智能平台告警信息
  • 每月:抽检10%灯具,用照度计抽测场地照度
  • 每季度:清洁灯具外表面灰尘(尤其室外投光灯和游泳馆三防灯)
  • 每年:全面检测一次照度、接地电阻、绝缘电阻;EPS电池放电测试
  • 每3年:清洗灯具透镜,检查驱动电容有无鼓包

D.2 故障处理流程

  1. 发现灯具不亮 → 先在智能平台查看是否有告警
  2. 平台显示”离线” → 现场检查供电、接线、驱动指示灯
  3. 驱动指示灯不亮 → 测量输入电压,判断是上游断电还是驱动损坏
  4. 驱动损坏 → 更换同型号驱动(KITOZER备件库常备)
  5. 灯板损坏 → 更换灯板模块
  6. 维修后在平台上复位告警,记录维修日志

D.3 备件管理

建议场馆常备以下备件:
– 常用型号驱动电源(按灯具总数5%备货)
– 应急灯电池(按应急灯总数10%备货)
– 保险丝、接线端子、防水接头
– 智能控制继电器模块、DALI模块


附录E:绿色建筑与LEED认证中的照明得分

E.1 中国绿色建筑评价标准

GB/T 50378《绿色建筑评价标准》对照明有专门得分项:
– 公共建筑室内照度达标得基础分
– 采用高效照明产品(光效≥110lm/W)加分
– 采用智能照明控制(分区、定时、感应)加分
– 照明功率密度(LPD)低于现行国标限值加分

KITOZER智能LED系统通常能帮助场馆在绿色建筑评价中拿到照明相关的大部分得分。

E.2 LEED v4.1 照明得分

美国LEED认证中,照明相关得分项包括:
– EQ Credit: Interior Lighting(室内照明质量)
– EQ Credit: Lighting Control(照明控制)
– EA Credit: Lighting Efficiency(照明能效)

KITOZER DALI智能系统+照度传感器+人体感应,可以同时满足这三个得分项的要求。

E.3 照明功率密度LPD

LPD(Lighting Power Density)= 照明总功率 / 建筑面积,单位W/㎡。GB 50034对不同建筑类型规定了LPD限值:
– 办公室:≤9 W/㎡
– 商场:≤10 W/㎡
– 体育馆:≤11 W/㎡
– 停车场:≤2.5 W/㎡

KITOZER智能LED系统通过调光策略,实际运行LPD通常只有标称LPD的40%—60%,远低于国标限值。


Appendix A: LED Optical and Thermal Engineering Deep Dive

A.1 LED Chip Physics and Packaging

To understand why KITOZER venue fixtures achieve 130–160 lm/W, it helps to start with LED physics. A light-emitting diode is a solid-state semiconductor built around a PN junction. When current flows across the junction, electrons recombine with holes in the active region and release energy as photons. The photon wavelength — i.e., the color — is set by the semiconductor bandgap: gallium nitride (GaN) emits blue light. Blue light passes through a yellow phosphor layer (YAG:Ce), where part of the blue is absorbed and re-emitted as broad-spectrum yellow; the mix of blue and yellow appears white to the human eye.

A typical white LED package, bottom to top, consists of a sapphire substrate (~100 μm thick), GaN epitaxial layers (N-type, multi-quantum-well active region, P-type), electrodes, silicone lens, and the yellow phosphor layer. KITOZER sources LEDs from mainstream supply chains; individual packages range 0.5W–3W per chip, with lab efficacy above 200 lm/W. Whole-fixture efficacy deducts optical losses (~5–8%), driver losses (~8–10%), and thermal derating (~5–10%), so 130–160 lm/W at the fixture level is a strong engineering result.

A.2 Photometric Curves and IES Files

Every LED fixture is measured on a goniophotometer before shipment, producing an IES (Illuminating Engineering Society) photometric data file. This file records luminous intensity in every spatial direction and is the input to DIALux lighting design software. KITOZER provides standard IES files for every fixture; designers import them into DIALux to predict on-ground illuminance distribution.

Photometric curves are usually drawn in polar coordinates: the fixture at center, radial distance as luminous intensity (cd), angle as spatial azimuth. Different beam angles produce completely different curve shapes: a 14° narrow beam is like a flashlight, concentrated in a tiny angular cone; a 60° wide beam is like an open fan covering a large area. KITOZER’s interchangeable-lens 1000W floodlight lets designers mix optics on the same pole: narrow beams reach the far corner, wide beams fill under the stands.

A.3 Why Thermal Design Determines LED Life

LED wall-plug efficiency is about 40–50%; more than half the input power becomes heat rather than light. If this heat is not conducted away, junction temperature Tj rises rapidly. Research shows that every 10°C rise in Tj roughly doubles the decay rate; above 105°C, phosphor darkens rapidly, silicone lens yellows, and life can drop from 100,000 hours to 20,000 hours.

KITOZER floodlight thermal path: LED board (aluminum substrate) → thermal grease → die-cast aluminum housing → fin convection → air. To minimize thermal resistance: (1) 2.0mm aluminum substrate with 2oz copper foil; (2) thermal grease ≥3 W/m·K at 0.1mm thickness; (3) ADC12 die-cast housing with hollow finned convection; (4) thermocouples at key board locations paired with driver thermal derating — above 85°C housing temperature, the driver automatically reduces current to protect the chips.

A.4 Driver Power Supply Key Specs

The driver is the LED’s “heart” and the most failure-prone component. KITOZER evaluates:

  • Efficiency: 90%+ means only 10% of input becomes heat; cooler drivers last longer.
  • Power factor: PF≥0.95 minimizes grid harmonic pollution, avoiding extra reactive compensation.
  • THD: <10% to avoid interfering with venue audio and broadcast.
  • Output ripple: <5% current ripple to avoid visible flicker.
  • Protection: output over-voltage, over-current, short, open-circuit, surge.
  • Operating temperature: -40°C to +70°C stable.
  • Life: electrolytic capacitor life sets driver life; KITOZER uses 105°C long-life caps, designed ≥50,000h.

A.5 Engineering Methods for Glare Control

Glare is the most common venue lighting complaint. Four engineering methods:

  1. Limit luminance: use small-chip arrays with diffuser lenses rather than single high-power bare chips.
  2. Control shielding angle: fixture cutoff angle ≥30° so chips are not visible at normal viewing angles.
  3. Add hoods: KITOZER-PJ1000 hood cuts uplight and side spill, keeping only useful downward light.
  4. Position wisely: avoid mounting fixtures directly above athlete sightlines; offset them.

A.6 Mathematical Definition of Uniformity

GB/T 35265 defines two uniformity metrics:

  • U1 = Emin / Eavg: minimum over average, reflecting the dimmest region.
  • U2 = Emin / Emax: minimum over maximum, reflecting contrast between darkest and brightest.

Professional competition requires U1≥0.7 and U2≥0.5. DIALux computes on a 1m×1m grid, reporting Emin, Emax, Eavg, then U1 and U2.


Appendix B: Typical Venue Calculation Worked Examples

B.1 Outdoor Tennis Court

Given:
– Court: 23.77m × 10.97m (doubles)
– Target horizontal: 300 lx (amateur training)
– Pole height: 12m
– Poles: two per long side
– Fixture: KITOZER-KT200W-2026, 24,000 lm, 120 lm/W

Estimate:
1. Area = 23.77 × 10.97 ≈ 261 m²
2. Required flux = target × area / (CU × MF)
– CU = 0.6 (outdoor flood, no wall reflection)
– MF = 0.7 (outdoor dust, cleaned every 3 years)
– Flux = 300 × 261 / (0.6 × 0.7) ≈ 186,000 lm
3. Fixtures = 186,000 / 24,000 ≈ 7.75 → 8
4. Layout: two poles per side, two fixtures per pole
5. DIALux on-site tuning after install

B.2 Indoor Basketball Court

Given:
– Court: 28m × 15m = 420 m²
– Target: 300 lx training
– Ceiling: 8m
– Fixture: KITOZER-HB200W high-bay, 26,000 lm

Estimate:
– Flux = 300 × 420 / (0.7 × 0.8) ≈ 225,000 lm (indoor wall reflection, CU=0.7, MF=0.8)
– Fixtures = 225,000 / 26,000 ≈ 8.6 → 12 (with margin for uniformity)
– Layout: two rows along length, 6 per row, 4m spacing

B.3 50m Swimming Pool

Given:
– Water surface: 50m × 25m = 1,250 m²
– Target surface: 300 lx (training)
– Fixture: KITOZER-TP36W tri-proof, 4,320 lm

Estimate:
– Pool CU is low (water absorbs light), take 0.5; MF = 0.75
– Flux = 300 × 1,250 / (0.5 × 0.75) = 1,000,000 lm
– Fixtures = 1,000,000 / 4,320 ≈ 231
– In practice, 50–60 high-power tri-proof fixtures along both long sides with bat-wing optics to avoid water reflection glare


Appendix C: Acceptance Testing Methods

C.1 Basis and Tools

At handover, owners usually commission a third-party lab (local building research institute or sports facility testing center) per GB/T 35265. Main tools:

  • Illuminance meter: Class A, annually calibrated, cosine-corrected probe
  • Luminance meter: for fixture surface brightness (glare calculation)
  • Spectrometer: on-site CCT and CRI
  • Tape/laser distance meter: probe position
  • Tripod: fixed probe height

C.2 Measurement Points

  • Horizontal illuminance: 2m×2m grid across playing area and buffer
  • Vertical illuminance: at field center, four camera directions, probe 1.5m high
  • Stands: front/middle/back rows
  • Emergency: escape route floor, stairwell, exit

C.3 Test Procedure

  1. All fixtures on, stabilize 30 minutes before measuring
  2. Horizontal illuminance point-by-point
  3. Vertical illuminance, rotate probe to four camera directions
  4. Measure fixture surface luminance, compute GR
  5. Spot-check 3–5 fixtures for CCT and CRI
  6. Power-off test: emergency switchover time and duration
  7. Issue report with point layout and numeric tables

C.4 Common Failures and Remediation

Failure Cause Fix
Horizontal too low underpowered / too few add or upsize fixtures
Poor uniformity asymmetric placement / aim on-site re-aim
Vertical fails wrong fixture tilt adjust pitch
Glare too high insufficient cutoff add hoods
CCT mismatch mixed batches replace to one batch
Emergency duration short weak battery / small EPS replace battery / upsize

Appendix D: Venue Lighting O&M Manual

D.1 Routine Inspection

Venue property teams should establish an inspection regime:

  • Daily: visual check before opening for dark, flickering, or buzzing fixtures
  • Weekly: inspect distribution boxes for odor/temperature; review smart platform alarms
  • Monthly: spot-test 10% of fixtures with an illuminance meter
  • Quarterly: clean fixture exterior dust (especially outdoor floodlights and pool tri-proof)
  • Annually: full illuminance, ground resistance, insulation resistance; EPS battery discharge test
  • Every 3 years: clean lenses, inspect driver capacitors for bulging

D.2 Fault Response Workflow

  1. Dark fixture → check smart platform alarm first
  2. Platform shows “offline” → field check power, wiring, driver LED
  3. Driver LED dark → measure input voltage, isolate upstream vs driver
  4. Driver failed → swap same model (KITOZER stocks spares)
  5. LED board failed → swap board module
  6. Reset alarm on platform, log repair

D.3 Spare Parts Management

Recommend stocking:
– Common drivers (5% of fixture count)
– Emergency batteries (10% of emergency count)
– Fuses, terminals, waterproof glands
– Smart control relay modules, DALI modules


Appendix E: Green Building and LEED Lighting Credits

E.1 China Green Building Standard

GB/T 50378 has dedicated lighting credits:
– Baseline score for compliant indoor illuminance
– Bonus for high-efficiency products (≥110 lm/W)
– Bonus for smart control (zoning, scheduling, occupancy)
– Bonus for Lighting Power Density (LPD) below code limits

KITOZER smart LED typically secures most lighting credits in green building evaluation.

E.2 LEED v4.1 Lighting Credits

LEED lighting credits:
– EQ Credit: Interior Lighting
– EQ Credit: Lighting Control
– EA Credit: Lighting Efficiency

KITOZER DALI + photosensors + occupancy sensors satisfy all three.

E.3 Lighting Power Density (LPD)

LPD = total lighting power / floor area, W/m². GB 50034 limits:
– Office: ≤9 W/m²
– Retail: ≤10 W/m²
– Gymnasium: ≤11 W/m²
– Parking: ≤2.5 W/m²

KITOZER smart LED dimming achieves actual running LPD at 40–60% of nameplate, well below code.


Appendix F: Export Packaging and International Shipping

F.1 Export Carton Standards

KITOZER export orders use export-grade packaging:
– Double-wall 5-ply corrugated carton with international shipping marks
– Foam custom-cut to fixture shape
– Desiccant packets inside each carton for sea freight humidity
– “This Way Up,” “Fragile,” “Keep Dry” labels in English
– Carton gross weight marked for forklift/hand truck handling

F.2 Palletization and Container Loading

  • Fixtures palletized on standard 1200×1000mm export pallets
  • Stretch-wrapped and corner-protected
  • Container loading: 20GP ~18 pallet positions, 40HQ ~38
  • KITOZER will advise on loading plan for maximum container utilization

F.3 Certificates for Export

  • CE declaration and test reports for EU
  • RoHS compliance
  • IP rating test reports
  • IES LM-79 photometric reports
  • Packaging material ISPM-15 (for wooden pallets)

F.4 Warranty for Overseas Projects

  • 5-year global warranty on LED fixtures (8-year outdoor floodlights)
  • Spare parts shipped from Guangzhou within 48 hours
  • Local engineer support available in Southeast Asia, Middle East, Africa via partners
  • English O&M manual and commissioning video provided

End of KITOZER Stadium LED Lighting Engineering Design Guide. For inquiries: call +86 18520668845, WhatsApp +86 19068534140, visit www.lain.com.cn or www.gdlain.com.


附录F:更多专项场馆照明设计

F.1 田径场照明设计

田径场通常包含400m环形跑道、中间足球场、跳远沙坑、铅球投掷区、跳高横杆区等多个子项。田径场周长约400m,占地面积大,照明主要靠沿跑道外圈布置的高杆灯。

设计要点:
– 跑道水平照度:训练100—200lx,比赛300—500lx
– 跳跃项目(跳远、跳高)垂直照度要求高,因为运动员要判断横杆位置
– 投掷项目(铅球、铁饼、标枪)注意灯光不能直射运动员眼睛影响投掷方向
– 高杆灯通常25—40m高,每杆装6—12盏400W—1000W投光灯
– 灯杆布置在跑道外圈至少10m以外,避免运动员碰撞

KITOZER典型配置:4根30m高杆,每杆8盏KT400W-2026,共32盏,总功率12.8kW,可满足区县级田径比赛训练需求。

F.2 体操馆照明设计

体操馆(自由体操、单杠、双杠、跳马、平衡木)对照度均匀度要求极高,因为运动员在空中翻转时眼睛要判断方向。体操馆顶棚通常很高(12—18m),需要大功率工矿灯。

设计要点:
– 水平照度:训练500lx,比赛750lx,转播1000lx
– 均匀度U1≥0.7(体操器械区)
– 垂直照度:运动员在空中的位置要清晰
– 灯具不能产生频闪,因为高速摄像会拍到翻转动作
– 防眩光:运动员在器械上仰视时不能看到灯

KITOZER推荐:KITOZER-HB200W/300W工矿灯,沿体操器械区上方均匀布置,配蝙蝠翼配光,UGR<25。

F.3 冰上场馆照明设计

冰球、短道速滑、花样滑冰场馆有特殊要求:冰面像巨大镜子反射灯光,眩光控制极难。

设计要点:
– 冰面水平照度:训练300lx,比赛500—1000lx
– 冰面反射率高,灯具必须严格控制上射光和侧向光
– 灯具安装角度避开冰面反射到观众席和摄像机的角度
– 低温环境(冰场温度16—18℃,冰面-5℃)驱动电源要选低温型
– 冰场周围围板要哑光,避免二次反射

KITOZER冰场方案采用KITOZER-KT400W投光灯从看台两侧投光,配遮光罩控制反射。

F.4 射击射箭馆照明设计

射击、射箭对灯光要求特殊:运动员要长时间瞄准,不能有眩光;靶纸颜色要真实还原(环靶黑白黄红蓝)。

设计要点:
– 射击位水平照度:500—750lx
– 靶面照度:均匀,不能有阴影
– 灯具不能出现在运动员视线里(瞄准方向)
– 显色指数Ra≥90,靶纸颜色必须真实
– 色温4000K—5000K

KITOZER推荐:靶道两侧墙面装KITOZER-LN线型灯,配防眩光格栅,运动员瞄准方向无灯具。

F.5 健身房与拳击台照明

健身房照明:
– 力量区:200—300lx,色温4000K
– 有氧区(跑步机、椭圆机):300lx
– 瑜伽/拉伸区:200—300lx,可调光暖光模式
– 镜子墙面避免灯具反射

拳击台:
– 拳台中央水平照度:750—1000lx
– 垂直照度:裁判、选手面部清晰
– 均匀度U1≥0.7
– 顶部顶灯从四角投光,不直射选手眼睛

F.6 网球场(室内)与壁球馆

室内网球场:
– 照度750lx比赛级
– 顶棚高≥9m(网球发球需要净空)
– 灯具沿场地长轴布置,UGR<25
– 后挡网区域也要照亮,避免球飞出后找不到

壁球馆:
– 四面墙都是比赛面,需要反射光
– 水平照度500lx
– 玻璃后墙不能有灯具反射
– 灯具装在屋顶,漫射配光

F.7 轮滑/滑板/极限运动场地

这类场地有斜坡、碗池、U型池,灯光要从多个角度照射,避免阴影影响运动员判断空中动作。通常用KITOZER-HB高天棚灯均匀布置,照度300—500lx,UGR<25。

F.8 展览馆、会议中心与场馆多功能转换

很多综合体育馆在非赛事时段会转型为展览馆、招聘会、演唱会场地。照明设计必须支持这种多功能转换:

  • 展览模式:300lx均匀照明,可临时增加展柜射灯
  • 会议模式:主席台区域重点照明,观众席降到200lx
  • 演唱会模式:场地灯降到20%,由舞台灯光主导
  • 集会模式:全场500lx

KITOZER-ISC平台的场景功能就是为这种多功能转换设计的。每个场景在软件里预先定义,切换时0.5秒内平滑过渡(不是突变,避免人眼不适)。


附录G:智能照明控制系统软件功能详解

G.1 场景管理模块

场景是智能照明的核心概念。一个场景就是”每一个回路应该亮到百分之几”的一张表。KITOZER-ISC软件预置了20+个典型场景模板,用户也可以自定义:

  • 新建场景:选择适用区域,拖动滑块设置每个回路亮度,命名保存
  • 编辑场景:在线修改某回路亮度,实时预览
  • 复制场景:从已有场景复制后微调,快速创建相似场景
  • 场景定时:把场景绑定到日程表,到时间自动执行
  • 场景手动触发:墙上面板或APP一键切换
  • 场景过渡时间:0.5—30秒可调,灯光平滑过渡不突兀

G.2 日程管理模块

日程表按周一到周日、节假日分别配置:

  • 按时间点调度:比如6:00清晨开放,8:00日常训练,18:00比赛模式
  • 按日出日落自动调度:接入天文时钟,冬季早开灯、夏季晚开灯
  • 按节假日模板:春节、国庆等特殊日期单独设置
  • 临时覆盖:临时活动时手动切换,活动结束后自动恢复日程

G.3 能耗分析模块

D4i灯具每15分钟上报一次实时功率,平台聚合后生成:

  • 今日/本周/本月能耗柱状图
  • 与上月、去年同期对比折线图
  • 各区域能耗占比饼图
  • 预计年电费与节费
  • 能耗异常告警(某回路功率突然升高可能是灯具故障)

G.4 故障告警模块

告警分级:
– 紧急:消防联动动作、灯具大面积掉线 → 弹窗+短信+APP推送
– 重要:单灯掉线、驱动过温 → APP推送
– 提示:灯具寿命预测到期 → 邮件提醒维护

告警记录保留1年,可导出CSV用于运维复盘。

G.5 多项目集中管理

连锁健身品牌、学校集团、体育系统往往有多个场馆。KITOZER-ISC企业版支持多项目集中管理:

  • 一个平台登录,切换不同场馆
  • 跨项目能耗对比报表
  • 批量固件升级
  • 统一告警中心

Appendix G: Additional Venue Types (English)

G.1 Athletics Track Lighting

Athletics fields include a 400m running oval, central football pitch, long jump sandpits, shot put circles, and high jump zones. The 400m perimeter requires high-pole floodlights.

Design notes:
– Track horizontal: training 100–200 lx, competition 300–500 lx
– Jump events need high vertical illuminance for bar judgment
– Throwing events must avoid direct glare into athlete’s throwing direction
– High poles 25–40m, each with 6–12×400W–1000W floodlights
– Poles ≥10m outside the track to avoid athlete collision

KITOZER typical: four 30m poles, 8×KT400W per pole (32 total, 12.8kW), for district-level athletics training.

G.2 Gymnastics Hall Lighting

Gymnastics (floor exercise, horizontal bars, parallel bars, vault, balance beam) demands extreme uniformity because athletes judge orientation mid-air. Ceilings are high (12–18m), requiring high-power high-bays.

Notes:
– Horizontal: training 500 lx, competition 750 lx, broadcast 1000 lx
– Uniformity U1≥0.7 over apparatus zones
– Vertical illuminance on airborne athletes
– Flicker-free for high-speed cameras
– Anti-glare: no fixtures visible when athletes look up on apparatus

KITOZER recommends HB200W/300W high-bays evenly above apparatus zones with bat-wing optics, UGR<25.

G.3 Ice Sports Venues

Ice hockey, short track, and figure skating pose special challenges: the ice acts as a giant mirror, making glare control extremely difficult.

Notes:
– Ice surface horizontal: training 300 lx, competition 500–1000 lx
– High reflectance requires strict uplight/side-spill control
– Fixture angles must avoid ice reflection to stands and cameras
– Cold environment (16–18°C arena, -5°C ice): low-temperature drivers
– Matte dasher boards to avoid secondary reflection

KITOZER ice solution uses KT400W floodlights from both stand sides with hoods.

G.4 Shooting and Archery

Shooting and archery require long aiming periods without glare; target paper colors must be accurately reproduced.

Notes:
– Shooting position horizontal: 500–750 lx
– Target face: uniform, shadow-free
– No fixtures in athlete’s aiming line
– CRI Ra≥90 (target paper colors)
– CCT 4000–5000K

KITOZER recommends LN linear lights along range side walls with anti-glare louvers; no fixtures along the aiming direction.

G.5 Boxing Ring and Gym

  • Strength area: 200–300 lx, 4000K
  • Cardio area: 300 lx
  • Yoga/stretch: 200–300 lx, dimmable warm mode
  • Avoid fixture reflection on mirrors

Boxing ring:
– Center horizontal: 750–1000 lx
– Vertical: clear faces of referee and boxers
– Uniformity U1≥0.7
– Corner-mounted floodlights, no direct glare

G.6 Multi-Use Conversion: Arena to Exhibition/Concert

Many comprehensive gymnasiums convert to exhibitions, job fairs, or concerts off-season. Lighting must support:
– Exhibition mode: 300 lx uniform, with optional spotlights for booths
– Conference mode: stage accent, audience 200 lx
– Concert mode: arena lights down to 20%, stage lighting dominates
– Assembly mode: full 500 lx

KITOZER-ISC scenes are designed for this conversion; transitions are smooth (0.5–30s ramp) to avoid eye discomfort.


Appendix H: Export Project Commissioning Protocol

H.1 Pre-Delivery Factory Test

Before shipment, every KITOZER project undergoes:

  1. Fixture burn-in: all fixtures burn 4 hours at factory, checked for color consistency, output, defects
  2. Control system integration test: DALI gateways, relays, dimming modules pre-configured to project DALI addresses in the factory
  3. Software pre-configuration: scenes, schedules, zones pre-loaded on the control PC with project naming
  4. Packaging inspection: each carton labeled, packing list verified
  5. Factory acceptance test (FAT): customer or consultant invited to witness for large projects

H.2 On-Site Commissioning Steps

  1. Unpack and inspect: match each carton to packing list, report damage
  2. Power-on sequence: energize distribution cabinet, then loop by loop
  3. DALI commissioning: software scans bus, confirms expected number of lamps
  4. Scene verification: trigger each scene, observe ramp times and brightness levels
  5. Sensor calibration: set occupancy sensor range/delay per zone
  6. Fire linkage test: simulate dry-contact fire alarm, verify emergency lights
  7. Illuminance handover: third-party or customer measures, signs off
  8. Training: 1-day operator training, deliver English manual and video

H.3 Documentation Delivered

  • As-built drawings (DWG + PDF)
  • Photometric IES files
  • Test reports (LM-79, IP, IK, surge)
  • Control system backup configuration file
  • O&M manual
  • Spare parts list
  • Commissioning report signed by both parties

Appendix I: Cost Benchmark Reference

The following reference prices (marked ×2) help owners budget. Actual prices depend on quantity, optics, control complexity, and site conditions.

Item Unit Reference Price (RMB, ×2)
KT1000W floodlight set 7,400
KT600W floodlight set 5,600
KT400W floodlight set 9,520
KT200W floodlight set 5,120
PJ1000 hood set 480
HB200W high-bay set 1,200
PL6060 panel set 280
PL12060 panel set 380
LN1200 linear set 380
DL15W downlight set 90
TP36W tri-proof set 320
EM5W emergency set 180
EX3W exit sign set 120
ST24V strip meter 36
PDX500 outdoor cabinet set 16,800
KZX800 indoor cabinet set 12,800
EPS20K set 168,000
ISC-V1 control system set 152,000
DG16 DALI gateway set 8,400
8-button smart panel set 1,200
200×200 cable tray meter 232
JDG20 conduit meter 18
Q235 bracket kg 34

These are reference prices only; final pricing per detailed drawings and contract.


附录H:常见照明故障深度排查指南

H.1 单盏LED灯具不亮

排查步骤:
1. 先在智能平台查看该灯具DALI地址是否在线
2. 如果显示离线,现场检查:
– 配电箱该回路断路器是否跳闸
– 灯具接线端子是否松动(振动可能导致)
– 驱动电源指示灯是否亮(绿色正常/红色故障)
3. 如果驱动指示灯不亮,用万用表测量驱动输入端是否有220V
– 无电压 → 上游线路故障,检查断路器和线缆
– 有电压但驱动不亮 → 驱动损坏,更换
4. 如果驱动指示灯亮但灯板不亮,测量驱动输出电压是否正常(通常30—50V DC)
– 无输出 → 驱动损坏
– 有输出但灯板不亮 → 灯板LED开路,更换灯板

H.2 整组灯具闪烁

可能原因:
– 驱动电源质量差,输出纹波大
– 调光信号线接触不良
– 电压波动大(上游变压器容量不足)
– 多回路共用零线导致串扰

解决:
– 更换高频恒流驱动
– 检查DALI总线接线,末端加10kΩ终端电阻
– 测量供电电压,必要时增加稳压器
– 各回路零线独立走线

H.3 DALI总线通讯失败

常见原因:
– DALI总线极性接反(DALI无极性但某些早期模块有要求)
– 总线过长(超过300m)
– 总线短路
– 地址冲突

解决:
– 检查总线电压,正常DALI总线在空闲时约16V
– 分段排查:断开一半灯具,看通讯是否恢复,逐步定位短路点
– 重新寻址:在软件里执行”重新编址”
– 超过300m加中继器

H.4 应急灯不亮

排查:
– 先按测试按钮,看应急灯是否点亮
– 如果不亮:电池可能亏电(长期未充电)
– 拆除电池测量电压,12V电池低于10V说明老化
– 更换电池后,充24小时再测试

H.5 照度逐年下降

LED灯具使用几年后照度下降是正常光衰,但如果下降速度过快:
– 检查是否环境温度过高(散热不良)
– 清洁灯具透镜(灰尘积聚会挡光)
– 检查驱动是否工作在恒压模式而非恒流(电流漂移导致过驱)
– 记录初始照度数据,每年对比,超过20%时安排更换


附录I:国际赛事照明认证对照

I.1 FIFA足球场地照明要求

FIFA《足球场照明指南》按赛事等级分四级:
– 足球基础设施(基层):200lx
– 国家俱乐部比赛:500lx
– 国际比赛(无HD转播):800lx
– 国际HD转播:1400—2000lx

FIFA特别要求垂直照度在四个摄像机方向的均匀度,以及色温5500—6000K。

I.2 FIBA篮球场地要求

FIBA《篮球手册》规定:
– 训练:200—300lx
– 国家比赛:500lx
– 国际比赛:750lx
– 奥运会/世锦赛HD:1500lx
– 眩光GR≤40
– CRI Ra≥80

I.3 BWF羽毛球认证

BWF要求:
– 国际比赛750—1000lx
– 均匀度U1≥0.8
– 灯具不得在比赛区域正上方
– UGR<19

I.4 FINA游泳要求

FINA要求:
– 比赛水面500lx
– 出发台、终点触壁板区域额外照明
– 色温5000K
– CRI≥80
– 水面反射眩光控制

I.5 ITF网球要求

ITF要求:
– 大满贯赛1000lx(HD转播)
– 职业赛700lx
– 俱乐部训练300lx
– 眩光GR≤35
– 摄像机方向垂直照度


附录J:KITOZER项目管理流程

J.1 售前阶段

  1. 客户咨询 → 技术工程师对接
  2. 收集需求:场地尺寸、照度等级、预算、工期
  3. 现场勘测(如需):拍照、测尺寸、看配电现状
  4. DIALux照度仿真
  5. 出具方案书+配置清单+参考报价
  6. 客户确认方案

J.2 合同与设计阶段

  1. 签订合同,收取预付款
  2. 深化设计:出具施工图纸(灯位、配电、控制)
  3. 客户图纸确认
  4. 物料采购与排产

J.3 生产与发货

  1. 工厂排产(常规7—15天,定制25—35天)
  2. 出厂前老化测试4小时
  3. 包装、装车
  4. 物流发货,跟踪到现场

J.4 施工与调试

  1. 现场交底
  2. 管线预埋、灯具安装
  3. 配电箱接线
  4. 通电测试、通讯调试、场景调试
  5. 第三方照度检测
  6. 72小时试运行

J.5 验收与培训

  1. 竣工验收,签署验收报告
  2. 操作培训(1天)
  3. 交付竣工资料
  4. 进入质保期

J.6 售后与回访

  1. 48小时电话响应
  2. 广东省内48小时上门
  3. 每季度电话回访
  4. 每年现场巡检一次

Appendix J: International Sports Lighting Certification Comparison

J.1 FIFA Football

FIFA “Football Stadium Lighting Guide” defines four tiers:
– Football infrastructure (grassroots): 200 lx
– National club match: 500 lx
– International (no HD): 800 lx
– International HD broadcast: 1400–2000 lx

FIFA requires vertical uniformity in four camera directions and CCT 5500–6000K.

J.2 FIBA Basketball

FIBA Manual:
– Training: 200–300 lx
– National: 500 lx
– International: 750 lx
– Olympics/Worlds HD: 1500 lx
– GR≤40, Ra≥80

J.3 BWF Badminton

BWF:
– International: 750–1000 lx
– Uniformity U1≥0.8
– No fixtures directly above court
– UGR<19

J.4 FINA Swimming

FINA:
– Competition water 500 lx
– Extra lighting on starting blocks and touch pads
– CCT 5000K, CRI≥80
– Water reflection glare control

J.5 ITF Tennis

ITF:
– Grand Slam 1000 lx HD
– Pro tour 700 lx
– Club training 300 lx
– GR≤35
– Vertical illuminance in camera directions


Appendix K: KITOZER Project Management Workflow

K.1 Pre-sales

  1. Inquiry → technical engineer assigned
  2. Requirements gathering: dimensions, class, budget, schedule
  3. Site survey if needed: photos, measurements, existing power
  4. DIALux simulation
  5. Proposal + BoQ + reference quote
  6. Customer confirmation

K.2 Contract and Design

  1. Sign contract, receive deposit
  2. Detailed design: layout, power, control drawings
  3. Customer drawing approval
  4. Material procurement and production scheduling

K.3 Production and Shipping

  1. Factory scheduling (standard 7–15 days, custom 25–35 days)
  2. 4-hour burn-in test
  3. Packing, loading
  4. Freight, tracking to site

K.4 Construction and Commissioning

  1. Site orientation
  2. Conduit embedding, fixture install
  3. Distribution wiring
  4. Power-on, comm, scene commissioning
  5. Third-party illuminance test
  6. 72-hour trial run

K.5 Acceptance and Training

  1. Final acceptance, sign-off
  2. Operator training (1 day)
  3. As-built documentation
  4. Warranty starts

K.6 After-sales and Follow-up

  1. 48h phone response
  2. On-site within Guangdong in 48h
  3. Quarterly phone follow-up
  4. Annual on-site inspection

Appendix L: Detailed Bilingual Glossary

Chinese English Abbrev.
发光二极管 Light Emitting Diode LED
金属卤化物灯 Metal Halide MH
高压钠灯 High Pressure Sodium HPS
光效 Efficacy lm/W
光通量 Luminous Flux lm
水平照度 Horizontal Illuminance Eh
垂直照度 Vertical Illuminance Ev
显色指数 Color Rendering Index CRI/Ra
相关色温 Correlated Color Temperature CCT
均匀度 Uniformity U1/U2
眩光指数 Glare Rating GR
统一眩光值 Unifed Glare Rating UGR
照明功率密度 Lighting Power Density LPD
利用系数 Coefficient of Utilization CU
维护系数 Maintenance Factor MF
分布光度计 Goniophotometer —
数字可寻址照明接口 Digital Addressable Lighting Interface DALI
电子镇流器 Electronic Ballast —
应急电源 Emergency Power Supply EPS
不间断电源 Uninterruptible Power Supply UPS
浪涌保护器 Surge Protective Device SPD
微型断路器 Miniature Circuit Breaker MCB
塑壳断路器 Molded Case Circuit Breaker MCCB
剩余电流动作保护器 Residual Current Circuit Breaker RCCB/RCBO
无金属卤化物 Mercury-free —
国际照明委员会 International Commission on Illumination CIE
电气与电子工程师协会 Institute of Electrical and Electronics Engineers IEEE
北美照明工程学会 Illuminating Engineering Society IES
国际田径联合会 World Athletics IAAF/WA
国际篮球联合会 International Basketball Federation FIBA
国际足球联合会 Fédération Internationale de Football Association FIFA
国际游泳联合会 Fédération Internationale de Natation FINA
国际网球联合会 International Tennis Federation ITF
世界羽毛球联合会 Badminton World Federation BWF
视频监控 Closed-Circuit Television CCTV
楼宇自动化系统 Building Automation System BAS/BMS
数据中心基础设施管理 Data Center Infrastructure Management DCIM
电能利用效率 Power Usage Effectiveness PUE
高天棚灯 High Bay HB
三防灯 Tri-proof Light TP
面板灯 Panel Light PL
线型灯 Linear Light LN
投光灯 Floodlight KT
筒灯 Downlight DL
应急灯 Emergency Light EM
出口标志 Exit Sign EX
带开关保险丝 Residual Current Circuit Breaker with Overcurrent RCBO
低烟无卤 Low Smoke Zero Halogen LSZH/W
双绞线 Unshielded/Shielded Twisted Pair UTP/STP
介质供电 Power over Ethernet PoE

This completes the KITOZER Stadium LED Lighting Engineering Design Guide. All trademarks belong to their respective owners. KITOZER is a registered brand of Guangzhou Laian Intelligent System Development Co., Ltd.


附录K:场馆照明经济性分析深度案例

K.1 案例A:某大学体育馆金卤灯改LED(2024年完工)

背景:
– 大学综合体育馆,建筑面积8000㎡
– 2008年建成,金卤灯照明,频繁烧坏
– 改造前灯具:400W金卤灯120盏,1000W金卤灯20盏
– 年运行时间:每天12小时,全年300天(寒暑假关闭)
– 电价:0.65元/kWh(学校用电优惠价)

改造前电费:
– 400W × 120 = 48kW
– 1000W × 20 = 20kW
– 合计68kW
– 年耗电:68 × 12 × 300 = 244,800 kWh
– 年电费:244,800 × 0.65 = ¥159,120

改造方案:
– 400W金卤灯 → KITOZER-KT200W LED投光灯 120盏(光效120lm/W,输出24,000lm,比原400W金卤灯24,000lm相当但功率减半)
– 1000W金卤灯 → KITOZER-HB200W工矿灯 30盏(比赛区加灯补光)
– 智能控制:KITOZER-ISC-V1,按课表自动调度
– 实际平均运行功率:约18kW(智能调光后)

改造后电费:
– 18 × 12 × 300 = 64,800 kWh
– 年电费:64,800 × 0.65 = ¥42,120

年节省:
– 电费节省:¥117,000
– 维护费节省:原金卤灯每年更换约30盏,每盏含人工约800元,年省¥24,000
– 合计年收益:¥141,000

改造投入:
– LED灯具:120×2560 + 30×1200 = ¥343,200
– 智能控制:¥76,000
– 配电箱/线缆/安装:¥80,000
– 旧灯拆除:¥15,000
– 合计:¥514,200

投资回收期:514,200 / 141,000 ≈ 3.6年

K.2 案例B:某商业综合体地下停车场LED改造(2025年)

背景:
– 商业综合体地下停车场,3层,共800个车位
– 原照明:2×36W双管荧光灯盘,每层约300套,共900套
– 24小时运行
– 电价:0.95元/kWh

改造前:
– 每套荧光灯盘实际功耗约80W(含镇流器)
– 总功率:900 × 80 = 72kW
– 年耗电:72 × 24 × 365 = 630,720 kWh
– 年电费:630,720 × 0.95 = ¥599,184

改造方案:
– 更换为KITOZER-TP18W LED三防灯,每车位1盏,共800盏
– 每盏内置24GHz微波雷达感应
– 策略:无人时10%亮度(约2W),有人/车时满功率(18W)
– 实测平均功率:约5W/盏(车位利用率约15%)

改造后:
– 总平均功率:800 × 5 = 4kW
– 年耗电:4 × 24 × 365 = 35,040 kWh
– 年电费:35,040 × 0.95 = ¥33,288

年节省:¥565,896

改造投入:
– 灯具:800 × 250(含感应)= ¥200,000
– 安装:¥60,000
– 合计:¥260,000

投资回收期:260,000 / 565,896 ≈ 0.46年(约5.5个月)

这是一个非常典型的停车场快速回收案例。地下停车场24小时常亮、人员活动时间占比低,人感联动节能率可达90%以上,投资回收期极短。

K.3 案例C:某区级游泳馆新建LED照明(2026年)

背景:
– 50m标准泳池8泳道,25m×50m水面
– 观众座席500座
– 新建项目,无旧灯

设计目标:
– 水面水平照度:500lx(比赛级)
– 垂直照度(裁判席):400lx
– CRI Ra≥80
– CCT 5000K

配置:
– KITOZER-TP36W三防灯:48盏(沿两侧纵向)
– KITOZER-EX3W应急出口标志:12盏
– KITOZER-EM5W应急灯:8盏
– KITOZER-ISC智能控制:1套
– KITOZER-EPS10kVA:1套

投资:
– 灯具:48×320 + 12×120 + 8×180 = ¥19,200
– 智能控制:¥76,000
– EPS:¥120,000
– 配电箱/线缆/安装:¥60,000
– 合计:¥275,200

运行电费:
– 灯具总功率:48×36 = 1,728W
– 每天运行10小时,年360天
– 年耗电:1.728 × 10 × 360 = 6,221 kWh
– 年电费:6,221 × 0.85 = ¥5,288

泳池照明在整个场馆能耗中占比很小,主要成本是初投资,运行电费几乎可以忽略。


附录L:LED照明与人体健康

L.1 蓝光危害与色温选择

LED白光由蓝光芯片+黄色荧光粉制成,4000K—6500K的白光中蓝光成分较高。长时间在高色温(>5000K)、高照度环境下,可能对人眼视网膜产生蓝光危害,也会抑制褪黑素分泌影响睡眠。

场馆建议:
– 比赛训练区:5000K—5700K(匹配电视转播,运动员需要清醒专注)
– 健身房、瑜伽室:4000K(中性偏暖,舒适)
– 运动员休息室、走廊:3000K—4000K(放松)
– 应急疏散:白色,确保识别

KITOZER灯具符合IEC 62471光生物安全标准,豁免类(Exempt Group),长时间使用安全。

L.2 频闪与健康

低频闪烁(<100Hz)的灯光会引起视觉疲劳、头痛、甚至光敏性癫痫。KITOZER驱动调光频率>1.5kHz,属于无频闪范围,符合IEEE 1789推荐的低风险水平。

L.3 显色性与运动表现

研究表明,高显色性灯光下运动员的反应速度更快、视觉舒适度更高。这也是国际赛事要求Ra≥80的原因之一。KITOZER灯具Ra≥80、R9>5,红色、肤色还原真实,有助于运动员判断球的旋转和轨迹。


Appendix M: Deep Economic Case Studies

M.1 University Gymnasium MH-to-LED Retrofit (2024)

Background:
– University comprehensive gymnasium, 8,000 m²
– Built 2008, MH lighting, frequent failures
– Original: 120×400W MH, 20×1000W MH
– Annual operating: 12h/day, 300 days/year (closed during holidays)
– Tariff: 0.65 RMB/kWh (university discounted rate)

Before:
– 400W×120 = 48kW; 1000W×20 = 20kW; total 68kW
– Annual energy: 68×12×300 = 244,800 kWh
– Annual bill: 244,800×0.65 = RMB 159,120

Retrofit:
– 400W MH → KITOZER-KT200W LED floodlights ×120 (same 24,000 lm, half power)
– 1000W MH → KITOZER-HB200W high-bays ×30 (added for competition area)
– KITOZER-ISC-V1 smart control, auto-scheduled by class timetable
– Actual average running power: ~18kW

After:
– 18×12×300 = 64,800 kWh
– Bill: RMB 42,120

Annual savings:
– Electricity: RMB 117,000
– Maintenance: old MH relamped ~30/year at RMB 800 each = RMB 24,000
– Total: RMB 141,000

Investment:
– Fixtures: 120×2560 + 30×1200 = RMB 343,200
– Smart control: RMB 76,000
– Distribution/cable/install: RMB 80,000
– Removal: RMB 15,000
– Total: RMB 514,200

Payback: 514,200 / 141,000 ≈ 3.6 years

M.2 Commercial Garage Retrofit (2025)

Background:
– 3-level underground garage, 800 spaces
– Original: 2×36W twin-tube troffers, ~300/level, 900 total
– 24×7 operation
– Tariff: 0.95 RMB/kWh

Before:
– Each troffer ~80W including ballast
– Total: 900×80 = 72kW
– Annual: 72×24×365 = 630,720 kWh
– Bill: RMB 599,184

Retrofit:
– KITOZER-TP18W LED tri-proof ×800, one per space
– 24GHz microwave radar per fixture
– Strategy: 10% when empty (~2W), 满功率 when occupied (18W)
– Measured average power: ~5W/fixture (15% occupancy)

After:
– Total average: 800×5 = 4kW
– Annual: 4×24×365 = 35,040 kWh
– Bill: RMB 33,288

Annual savings: RMB 565,896
Investment: Fixtures 800×250 = RMB 200,000 + install RMB 60,000 = RMB 260,000
Payback: ~0.46 years (~5.5 months)

This is a classic fast-payback garage case: 24×7 always-on, low occupancy, occupancy-linked dimming saves >90%.

M.3 District Swimming Pool New Build (2026)

  • 50m 8-lane pool, 25m×50m water
  • 500 spectator seats
  • New build

Design target:
– Water surface horizontal: 500 lx (competition)
– Vertical (judge): 400 lx
– CRI Ra≥80, CCT 5000K

Configuration:
– KITOZER-TP36W tri-proof: 48 (along both long sides)
– KITOZER-EX3W exit signs: 12
– KITOZER-EM5W emergency: 8
– KITOZER-ISC control: 1 set
– KITOZER-EPS10kVA: 1 set

Investment:
– Fixtures: 48×320 + 12×120 + 8×180 = RMB 19,200
– Control: RMB 76,000
– EPS: RMB 120,000
– Distribution/cable/install: RMB 60,000
– Total: RMB 275,200

Operating electricity:
– Fixture power: 48×36 = 1,728W
– 10h/day, 360 days
– Annual: 1.728×10×360 = 6,221 kWh
– Bill: RMB 5,288

Pool lighting is a small fraction of venue energy; main cost is capex, running cost negligible.


Appendix N: LED Lighting and Human Health

N.1 Blue Light and CCT Selection

White LEDs use blue chips + yellow phosphor; 4000K–6500K white light contains significant blue. Prolonged exposure to high CCT (>5000K) at high illuminance may cause retinal blue-light hazard and suppress melatonin.

Venue recommendations:
– Competition/training: 5000–5700K (broadcast match, athletes alert)
– Gym/yoga: 4000K (neutral-warm, comfortable)
– Athlete lounge/corridor: 3000–4000K (relaxing)
– Emergency egress: white for identification

KITOZER fixtures meet IEC 62471 photobiological safety, Exempt Group, safe for prolonged use.

N.2 Flicker and Health

Low-frequency flicker (<100Hz) causes eye strain, headaches, even photosensitive epilepsy. KITOZER driver dimming frequency >1.5 kHz, flicker-free, meeting IEEE 1789 low-risk level.

N.3 Color Rendering and Athletic Performance

Studies show athletes react faster and report better visual comfort under high-CRI lighting. This is why international events require Ra≥80. KITOZER Ra≥80, R9>5 gives true reds and skin tones, helping athletes judge ball spin and trajectory.


Appendix O: Project Reference Price List (Detailed)

The following reference prices (marked ×2) help owners budget. Actual prices depend on quantity, optics, control complexity, and site conditions.

Item Unit Reference Price (RMB, ×2)
KT1000W floodlight set 7,400
KT600W floodlight set 5,600
KT400W floodlight set 9,520
KT200W floodlight set 5,120
PJ1000 hood set 480
HB200W high-bay set 1,200
HB150W high-bay set 950
HB100W high-bay set 700
PL6060 panel set 280
PL12060 panel set 380
LN1200 linear set 380
LN600 linear set 220
DL15W downlight set 90
TP36W tri-proof set 320
TP18W tri-proof set 180
EM5W emergency set 180
EX3W exit sign set 120
ST24V strip meter 36
ST200W street light set 1,800
PDX500 outdoor cabinet set 16,800
KZX800 indoor cabinet set 12,800
EPS10kVA set 120,000
EPS20kVA set 168,000
EPS30kVA set 220,000
ISC-V1 control system set 152,000
DG16 DALI gateway set 8,400
8-button smart panel set 1,200
Microwave sensor set 180
Photosensor set 250
Astronomical clock set 800
Cable tray 200×200 meter 232
JDG20 conduit meter 18
Q235 bracket kg 34

These are reference prices only; final pricing per detailed drawings and contract.


附录M:线缆、桥架与接地施工规范详解

M.1 电力电缆截面选择计算

照明回路电缆截面的选择要同时满足三个条件:载流量、电压降、机械强度。

载流量计算:
– 一个16A断路器回路,按80%负载率,实际工作电流约12.8A
– 选用2.5mm²铜芯聚氯乙烯绝缘电缆(BV),空气中载流量约25A,满足
– 但考虑LED开关电源的启动浪涌和环境温度修正(35℃时载流量打8折),实际选4mm²更稳妥

电压降计算:
– 单相220V回路,允许电压降≤3%(即≤6.6V)
– 4mm²铜缆电阻约4.6Ω/km
– 回路长度100m,电流10A时电压降 = 10A × 0.46Ω = 4.6V,满足
– 超过100m的回路要放大电缆截面

KITOZER推荐截面:
– 照明支路(单回路≤16A):WDZ-YJY-3×4mm²
– 应急支路(耐火):WDZN-YJY-3×6mm²
– 楼层主干(多回路):WDZB1-YJY-4×25+1×16
– 室外主干(铠装):YJV22-4×300+1×150

M.2 DALI控制线布线要求

DALI控制线虽然是低压(16V),但布线有严格要求:

  1. 使用屏蔽双绞线:ZC-RVVP-2×1.5,屏蔽层单端接地
  2. 与电力线分管敷设:DALI总线与220V电力线间距≥100mm,避免干扰
  3. 总线长度限制:单条DALI总线最大300m(线径1.5mm²)
  4. 总线拓扑:自由拓扑(手拉手或星形均可),不要求环形
  5. 末端终端电阻:总线最远端并联一个10kΩ电阻
  6. 极性无关:DALI总线无极性,接反也能工作
  7. 电源:DALI总线需要一个专用电源(通常集成在网关或配电箱里),输出16V/250mA

M.3 桥架安装规范

  • 桥架水平敷设时距地高度一般不低于2.5m
  • 垂直敷设时距地1.8m以下部分应加金属盖板保护
  • 桥架转弯半径不小于桥架内电缆最小允许弯曲半径
  • 桥架全线可靠接地,跨接线用编织铜线
  • 强弱电桥架平行间距≥300mm,交叉时垂直间距≥100mm

M.4 接地施工

  • 灯具金属外壳必须与PE线可靠连接
  • 每根室外灯杆底部设接地极,接地电阻≤10Ω
  • 所有配电箱门与箱体用编织软铜线跨接
  • 接地干线用BV-16mm²黄绿双色线
  • 整个场馆共用接地系统时,接地电阻≤1Ω

附录N:典型项目配置清单(完整BOM)

N.1 中型综合体育馆(5000座)

序号 产品名称 型号 数量 单位
1 LED投光灯1000W KITOZER-KT1000W-2026 24 套
2 LED投光灯400W KITOZER-KT400W-2026 16 套
3 LED工矿灯200W KITOZER-HB200W-2026 48 套
4 LED线型灯36W KITOZER-LN1200-2026 80 套
5 LED三防灯36W KITOZER-TP36W-2026 60 套
6 LED面板灯36W KITOZER-PL6060-2026 120 套
7 LED筒灯15W KITOZER-DL15W-2026 80 套
8 LED应急灯5W KITOZER-EM5W-2026 40 套
9 LED疏散指示3W KITOZER-EX3W-2026 60 套
10 遮光罩 KITOZER-PJ1000-2026 40 套
11 智能照明控制系统 KITOZER-ISC-V1-2026 1 套
12 DALI网关 KITOZER-DG16-2026 4 台
13 智能面板8键 KITOZER-SP8-2026 16 个
14 EPS应急电源20kVA KITOZER-EPS20K-2026 1 套
15 户外落地配电箱 KITOZER-PDX500-2026 4 套
16 室内壁挂配电箱 KITOZER-KZX800-2026 6 套
17 微波感应器 KITOZER-MS24G-2026 80 个
18 照度传感器 KITOZER-PS10-2026 12 个

N.2 室外11人制足球场(HD转播级)

序号 产品名称 型号 数量 单位
1 LED投光灯1000W KITOZER-KT1000W-2026 48 套
2 遮光罩 KITOZER-PJ1000-2026 48 套
3 灯具支架 KITOZER-DJ04-2026 48 套
4 室外配电箱 KITOZER-PDX500-2026 4 套
5 DALI网关 KITOZER-DG16-2026 2 台
6 智能控制主机 KITOZER-ISC-V1-2026 1 套
7 EPS应急电源30kVA KITOZER-EPS30K-2026 1 套
8 高杆灯40m(含基础) KITOZER-GP40-2026 4 基

N.3 羽毛球馆(10片标准场地)

序号 产品名称 型号 数量 单位
1 LED线型灯36W UGR<19 KITOZER-LN1200-2026 80 套
2 LED面板灯36W(走廊) KITOZER-PL6060-2026 20 套
3 LED应急灯 KITOZER-EM5W-2026 10 套
4 智能面板 KITOZER-SP8-2026 4 个
5 智能控制系统 KITOZER-ISC-V1-2026 1 套

Appendix P: Cable, Tray, and Grounding Construction Specifications

P.1 Cable Sizing

Lighting cable sizing must satisfy ampacity, voltage drop, and mechanical strength.

Ampacity:
– 16A breaker at 80% load = 12.8A working
– 2.5mm² Cu PVC (BV) air ampacity ~25A; with 35°C derating (×0.8) and LED inrush, 4mm² is safer

Voltage drop:
– Single-phase 220V, allowed ≤3% (≤6.6V)
– 4mm² Cu resistance ~4.6Ω/km
– 100m loop at 10A: drop = 10×0.46 = 4.6V, OK
– Runs over 100m must upsize

KITOZER recommended sizes:
– Lighting branch (≤16A): WDZ-YJY-3×4mm²
– Emergency branch (fire-rated): WDZN-YJY-3×6mm²
– Floor main: WDZB1-YJY-4×25+1×16
– Outdoor armored main: YJV22-4×300+1×150

P.2 DALI Control Wiring

Although DALI is low-voltage (16V), wiring is strict:

  1. Shielded twisted pair: ZC-RVVP-2×1.5, shield grounded at one end
  2. Separate conduit from power: DALI bus ≥100mm from 220V power
  3. Bus length: max 300m (1.5mm²)
  4. Topology: free (daisy-chain or star), no loop required
  5. End-of-line resistor: 10kΩ at bus farthest end
  6. Polarity-independent: reversed still works
  7. Bus power: dedicated 16V/250mA supply (integrated in gateway/panel)

P.3 Cable Tray Installation

  • Horizontal tray height ≥2.5m above floor
  • Vertical runs below 1.8m need metal cover
  • Bend radius ≥ minimum cable bend radius
  • Tray fully bonded, braided jumper across sections
  • Power and signal trays parallel ≥300mm; crossing ≥100mm vertical

P.4 Grounding

  • All metal fixture bodies bonded to PE
  • Each outdoor pole: ground rod, resistance ≤10Ω
  • All panel doors bonded to body with braid
  • Ground main: BV-16mm² green-yellow
  • Shared building ground: ≤1Ω

Appendix Q: Complete Bill of Materials Reference

Q.1 Medium Comprehensive Gymnasium (5,000 seats)

# Item Model Qty Unit
1 LED floodlight 1000W KITOZER-KT1000W-2026 24 set
2 LED floodlight 400W KITOZER-KT400W-2026 16 set
3 LED high-bay 200W KITOZER-HB200W-2026 48 set
4 LED linear 36W KITOZER-LN1200-2026 80 set
5 LED tri-proof 36W KITOZER-TP36W-2026 60 set
6 LED panel 36W KITOZER-PL6060-2026 120 set
7 LED downlight 15W KITOZER-DL15W-2026 80 set
8 LED emergency 5W KITOZER-EM5W-2026 40 set
9 LED exit sign 3W KITOZER-EX3W-2026 60 set
10 Floodlight hood KITOZER-PJ1000-2026 40 set
11 Smart control system KITOZER-ISC-V1-2026 1 set
12 DALI gateway KITOZER-DG16-2026 4 pc
13 8-button smart panel KITOZER-SP8-2026 16 pc
14 EPS 20kVA KITOZER-EPS20K-2026 1 set
15 Outdoor floor cabinet KITOZER-PDX500-2026 4 set
16 Indoor wall cabinet KITOZER-KZX800-2026 6 set
17 Microwave sensor KITOZER-MS24G-2026 80 pc
18 Photosensor KITOZER-PS10-2026 12 pc

Q.2 Outdoor 11-a-side Football (HD Broadcast)

# Item Model Qty Unit
1 LED floodlight 1000W KITOZER-KT1000W-2026 48 set
2 Hood KITOZER-PJ1000-2026 48 set
3 Mount bracket KITOZER-DJ04-2026 48 set
4 Outdoor panel KITOZER-PDX500-2026 4 set
5 DALI gateway KITOZER-DG16-2026 2 pc
6 Control host KITOZER-ISC-V1-2026 1 set
7 EPS 30kVA KITOZER-EPS30K-2026 1 set
8 40m high pole w/ foundation KITOZER-GP40-2026 4 pole

Q.3 Badminton Hall (10 Courts)

# Item Model Qty Unit
1 LED linear 36W UGR<19 KITOZER-LN1200-2026 80 set
2 LED panel 36W (corridor) KITOZER-PL6060-2026 20 set
3 LED emergency KITOZER-EM5W-2026 10 set
4 Smart panel KITOZER-SP8-2026 4 pc
5 Smart control system KITOZER-ISC-V1-2026 1 set

Appendix R: Frequently Asked Questions — Extended 40 More

Q41: Can KITOZER provide DIALux IES files?
A: Yes. Every KITOZER fixture model has a standard IES photometric file, free for design partners. We can also custom-tailor IES for special optics.

Q42: What is the lead time for a 1000W floodlight order of 100 units?
A: Standard stock 7–15 days. Custom CCT or special optics 25–35 days.

Q43: Do you offer site survey service?
A: Yes, within Guangdong province for projects above RMB 200k. Out-of-province we can guide via photos/dimensions, or charge a site survey trip fee.

Q44: Can KITOZER supply lighting only, without installation?
A: Yes. We supply fixtures, control, and panels; local electricians can install under our remote guidance. We provide detailed installation drawings and commissioning support.

Q45: What is the difference between DALI-2 and DALI-1?
A: DALI-2 is the updated IEC 62386-209 standard with better interoperability, fixed color temperature, and D4i energy/temperature telemetry. KITOZER uses DALI-2 throughout.

Q46: Can I upgrade an existing 0-10V system to DALI?
A: Usually yes if the drivers are accessible. We can add DALI drivers, gateways, and software while keeping existing fixtures and wiring.

Q47: How does KITOZER handle typhoon-season pole inspection?
A: We recommend annual pre-typhoon inspection: re-torque bolts, check fixture aim, inspect hoods, verify grounding. KITOZER offers this as a paid service.

Q48: Are KITOZER fixtures dimmable to 1%?
A: Yes, DALI-2 dimming down to 0.1%. 0-10V dimming typically down to 10%.

Q49: What is the color consistency between batches?
A: MacAdam ellipse ≤3-step across batches, visible color difference minimized.

Q50: Can the system be controlled by a web browser?
A: Yes, KITOZER-ISC-V1 has a web client accessible on any modern browser; no special software needed.

Q51: Does the system support third-party wall switches?
A: Yes, via dry-contact interface. Existing wall switches can be wired as scene triggers.

Q52: What happens if the control network goes down?
A: Fixtures default to last state or a pre-configured safe scene. Local wall panels still work. The system auto-reconnects when network is restored.

Q53: Can we add fixtures later?
A: Yes. DALI gateways support up to 1024 fixtures per gateway; add more gateways as needed. The software auto-discovers new fixtures.

Q54: Is there a mobile app for iOS and Android?
A: Yes, native apps for both platforms, with role-based access.

Q55: Can the system integrate with venue booking software?
A: Yes, via REST API. We can provide API documentation for your booking system vendor.

Q56: What is the typical power factor of KITOZER fixtures?
A: ≥0.95 at full load.

Q57: Is there surge protection built in?
A: Yes, line-line 5kV, line-earth 10kV on outdoor floodlights.

Q58: Can KITOZER do projects outside China?
A: Yes, gdlain.com serves export markets. We have completed projects in Southeast Asia, Middle East, and Africa. Export packaging, CE/RoHS docs, and English manuals provided.

Q59: What payment terms do you offer?
A: Standard: 30% deposit on contract, 60% on delivery, 10% on acceptance. Long-term partners can negotiate.

Q60: How do you handle warranty claims?
A: Contact us with model, serial number, and photos/videos. We diagnose remotely; if defective, ship replacement spares within 48h.

Q61: Can KITOZER brand fixtures under our own brand?
A: OEM/ODM is available for volume orders. Contact our sales team for details.

Q62: Do you provide photometric test reports for each project?
A: Yes, IES LM-79 reports from CNAS-accredited labs are available.

Q63: What is the maximum pole height for your floodlights?
A: We recommend up to 60m for 1000W fixtures with narrow 14° optics. Above 60m, we would need custom high-power solutions.

Q64: Can KITOZER lights be used in coastal salt-fog areas?
A: Yes. Outdoor fixtures pass 96-hour salt fog test. We recommend stainless steel hardware and annual cleaning in coastal areas.

Q65: What is the expected life of the driver vs the LED board?
A: LED board L70 ~100,000h; driver designed ~50,000h. The driver is modular and field-replaceable, so you can swap drivers without replacing the whole fixture.

Q66: How do you calculate the number of fixtures for a venue?
A: We use DIALux evo with the venue CAD model. The process takes 1–3 working days depending on complexity.

Q67: Can KITOZER provide 3000K warm white for hospitality areas?
A: Yes, 3000K/4000K/5000K/5700K all available on most models.

Q68: Is the smart system cloud-based or on-premise?
A: Both options. On-premise server for security-sensitive data centers; cloud SaaS for multi-site chains.

Q69: What is the Wi-Fi requirement for the wireless version?
A: Zigbee wireless does not need Wi-Fi; it forms its own mesh network. The gateway connects to your Ethernet.

Q70: Can KITOZER help with building permit documents?
A: Yes, we provide lighting layout drawings, load schedules, and control schematics stamped by our engineers for permit submission.

Q71: How long does a typical installation take?
A: 5,000 m² comprehensive gymnasium: 2–4 weeks including commissioning. Outdoor football field with poles: 4–8 weeks including foundation curing.

Q72: Do you provide training for our staff?
A: Yes, 1-day on-site training included in every project, covering daily operation, scene switching, fault response, and basic maintenance.

Q73: Can the system read energy data for ESG reporting?
A: Yes, D4i energy data can be exported as CSV or integrated into ESG platforms via API.

Q74: What is the noise level of the fixtures?
A: LED fixtures are silent (no ballast hum). This is important for quiet venues like shooting ranges and theaters.

Q75: Do you have a reference project near us?
A: We have projects across Guangdong and nationwide. Contact us with your location and we can arrange a reference visit.

Q76: Can KITOZER provide lighting for climbing walls?
A: Yes, climbing walls need high horizontal and vertical illuminance on the wall surface, with glare control for climbers. We use wide-beam panel lights from the side.

Q77: What about lighting for outdoor playgrounds (children’s)?
A: 100–200 lx, IP65 fixtures, pole height 6–8m, with anti-glare shields. We recommend 4000K for a welcoming feel.

Q78: Can KITOZER do facade and decorative lighting for the venue building?
A: Yes, our strip lights (KITOZER-ST24V) and wall packs can do architectural facade lighting separately from sports lighting.

Q79: Is there a BMS (building management) integration protocol?
A: BACnet/IP, Modbus TCP, KNX, SNMP all supported.

Q80: What is the single most important thing owners should do when planning venue lighting?
A: Run a DIALux simulation before buying. Many owners buy fixtures by eye, then discover uneven illumination or glare after installation. A RMB 5,000–10,000 DIALux design fee saves hundreds of thousands in rework.


附录O:体育场馆照明未来趋势

O.1 人因照明(Human Centric Lighting)

未来场馆照明不再只满足”够亮”,而是要根据运动员的生物节律调节色温:训练时段用5000K冷白光保持专注,放松时段切换到3000K暖白光帮助恢复。KITOZER正在开发双色温可调灯具,支持同一盏灯在3000K—5700K之间平滑调节,配合场景切换实现”竞技模式”与”恢复模式”的色温过渡。

O.2 LiFi与照明融合通信

LED灯可以被高速调制用于数据通信(LiFi),未来场馆灯具不仅照明,还可作为无线AP覆盖观众席、运动员区的无线网络。KITOZER已在部分项目试点。

O.3 数字孪生与照明BIM集成

大型场馆在设计阶段就将照明系统纳入BIM模型,与结构、机电、消防协同设计。运营阶段,数字孪生平台实时映射灯具状态、能耗、故障,实现预测性维护。

O.4 光伏一体化

场馆屋顶铺设光伏板,白天发的电直接供给照明系统,多余电量存入储能电池。配合智能照明控制,实现场馆照明”自发自用”,进一步降低电费。

O.5 人工智能算法优化

智能算法将根据场馆历史使用数据、天气、预约情况,自动优化照明策略,比人工设定的日程表更节能。


附录P:KITOZER质量保证体系

P.1 研发与设计

KITOZER灯具研发流程:
1. 需求输入:市场调研、客户反馈、标准更新
2. 光学设计:用LightTools做透镜设计,TracePro做光线追迹
3. 热设计:用FloEFD做热仿真,确定散热结构
4. 结构设计:SolidWorks建模,3D打印手板验证
5. 电子设计:驱动原理图、PCB Layout
6. 样机制作:3—5台样机
7. 实验室测试:LM-79光学、LM-80光衰、高低温、盐雾、IP
8. 小批量试产:50台,老化48小时
9. 量产

P.2 供应链

KITOZER关键物料供应商:
– LED灯珠:行业主流国产/进口品牌
– 驱动电源:知名电源品牌定制
– 透镜:光学级PC/PMMA
– 散热器:ADC12铝合金压铸
– 电子元件:工业级,-40℃—+85℃

所有供应商每年审核一次,关键物料双供应商备份。

P.3 生产与测试

  • SMT贴片:全自动生产线,AOI光学检测
  • 整灯组装:流水线,每工位有作业指导书
  • 老化测试:每盏灯出厂前点亮4小时
  • 全检:外观、点亮、接线、标签
  • 抽检:按AQL 0.65抽样做IP防护、耐压、接地电阻测试

P.4 质量管理体系

KITOZER执行ISO 9001质量管理体系,从订单评审、采购、生产、检验到售后全过程受控。每台灯具都有专属序列号,可追溯到生产批次、物料批次、检验记录。


Appendix S: Future Trends in Stadium Lighting

S.1 Human Centric Lighting

Future venue lighting will not only meet “bright enough” but adjust color temperature to athletes’ circadian rhythm: 5000K cool white during training for focus, switching to 3000K warm white during recovery. KITOZER is developing dual-CCT tunable fixtures that smoothly transition 3000K–5700K, pairing with scenes for “competition” and “recovery” modes.

S.2 LiFi and Lighting-as-Communication

LEDs can be modulated at high speed for LiFi data communication. Future venue fixtures will not only light but also serve as wireless APs covering spectator and athlete zones. KITOZER is piloting this in selected projects.

S.3 Digital Twin and BIM Integration

Large venues now include lighting in BIM design, coordinating with structure, MEP, and fire protection. In operations, a digital twin platform maps fixture status, energy, and faults in real time for predictive maintenance.

S.4 PV Integration

Venue rooftop PV generates power during the day directly for lighting, with surplus stored in batteries. Combined with smart control, venue lighting becomes “self-generated, self-consumed,” further reducing electricity bills.

S.5 Algorithm-Based Optimization

Advanced algorithms optimize lighting strategies based on historical usage, weather, and bookings, beating manual schedules.


Appendix T: KITOZER Quality Assurance System

T.1 R&D Process

KITOZER fixture development:
1. Requirements: market research, customer feedback, standards update
2. Optical design: LightTools for lens, TracePro ray tracing
3. Thermal design: FloEFD simulation
4. Structural design: SolidWorks, 3D-printed prototypes
5. Electronic design: driver schematics, PCB layout
6. Prototype: 3–5 units
7. Lab tests: LM-79, LM-80, temp cycling, salt fog, IP
8. Pilot run: 50 units, 48h burn-in
9. Mass production

T.2 Supply Chain

Key component suppliers:
– LED chips: mainstream domestic/imported brands
– Drivers: reputable power supply brands, custom-built
– Lenses: optical-grade PC/PMMA
– Heat sinks: ADC12 aluminum die-cast
– Electronics: industrial-grade, -40°C–+85°C

All suppliers audited annually; critical components have dual-source backup.

T.3 Production and Testing

  • SMT: automated line with AOI optical inspection
  • Assembly: conveyor line with work instructions per station
  • Burn-in: every fixture lit 4 hours before shipment
  • Full inspection: appearance, lighting, wiring, labels
  • Sampling: AQL 0.65 for IP, dielectric, ground bond

T.4 Quality System

KITOZER operates ISO 9001, controlling order review, procurement, production, inspection, and after-sales. Every fixture has a unique serial number traceable to production batch, material batch, and inspection records.


Appendix U: About KITOZER and Guangzhou Laian

Guangzhou Laian Intelligent System Development Co., Ltd. was founded in Guangzhou, China, focusing on intelligent systems for data centers, sports venues, industrial parks, and smart buildings. The KITOZER brand covers LED lighting, power distribution, monitoring, and integrated cabinets.

Factory location: No. 5 Huashan Road, Shilou, Panyu, Guangzhou, in the Zhongrun Industrial Park Chaotian campus.

Core competencies:
– LED lighting engineering design and manufacturing
– Smart lighting control systems (DALI-2, 0-10V, wireless)
– Electrical distribution and emergency power
– Data center infrastructure integration
– Custom steel fabrication and sheet metal work

Markets:
– Domestic: lain.com.cn serves China projects
– Export: gdlain.com serves overseas customers in Southeast Asia, Middle East, Africa, and beyond

Contact:
– Mobile/WeChat: +86 18520668845 / +86 13922289957
– WhatsApp: +86 19068534140
– Web: www.lain.com.cn | www.gdlain.com

Working hours: Monday–Saturday, 9:00–18:00 (Beijing Time, UTC+8).


This completes the KITOZER Stadium LED Lighting Engineering Design Guide. Thank you for reading. For project inquiries, please contact the KITOZER engineering team at +86 18520668845 or WhatsApp +86 19068534140.


附录Q:详细施工组织设计

Q.1 施工准备阶段

在正式开工前,KITOZER项目团队会完成以下准备工作:

技术准备:
– 组织施工人员熟悉施工图纸、照明设计说明、配电系统图
– 进行图纸会审,与设计院、业主、监理沟通疑问
– 编制施工组织设计和专项方案
– 对施工班组进行技术交底和安全交底

现场准备:
– 勘察现场临时仓库、材料堆放场地
– 接通临时用电(380V三相五线)
– 设置安全警示标识
– 高空作业审批(灯杆上杆、马道安装)

材料准备:
– 材料按计划分批进场
– 进场材料报验:合格证、检测报告、CCC证书
– 灯具抽样送检(如需监理见证取样)

Q.2 管线预埋施工

  • 配合土建阶段:穿线管、接线盒随钢筋预埋
  • 金属管弯曲半径≥6倍管外径,弯曲处无褶皱
  • 管口打磨光滑,穿线后管口加护口
  • 吊顶内管线与空调、消防管线分层布置,照明管线在上层
  • 管线穿墙、楼板处加套管,防火封堵

Q.3 灯具安装施工

室内灯具:
– 面板灯嵌入吊顶,与石膏板齐平
– 重型灯具(>3kg)单独膨胀螺栓固定
– 线型灯吊装使用全牙吊杆,间距≤1.5m
– 灯具安装后通电试亮,检查是否有不亮、频闪

室外投光灯:
– 灯杆吊装前在地面完成灯具预组装
– 灯杆垂直度偏差≤3‰
– 灯具角度按DIALux设计初调,夜间精调
– 所有螺栓涂螺纹锁固胶

游泳馆灯具:
– 接线口朝下
– 电缆入口做防水弯
– 灯具与池壁保持安全距离

Q.4 配电箱安装

  • 落地箱基础高出地面100mm,做好防水
  • 壁挂箱底边距地1.4m
  • 箱内断路器排列整齐,标识清晰
  • 零线、地线分别汇流排
  • 箱体接地可靠

Q.5 调试与试运行

  • 分回路通电,先不接灯具,测电压
  • 接入灯具后逐回路点亮
  • DALI总线扫描,确认灯具数量
  • 场景切换测试
  • 消防联动测试
  • 照度检测
  • 72小时连续试运行

Q.6 竣工验收资料

竣工时提交:
– 竣工图纸(DWG+PDF)
– 灯具清单及合格证
– 第三方照度检测报告
– 电气测试记录(绝缘、接地、相序)
– 智能控制调试报告
– 操作维护手册
– 培训记录
– 验收证书


附录R:常见业主疑问解答

R.1 “我们场馆已经有灯光了,为什么要换?”

常见原因:
– 原金卤灯频繁烧坏,维护成本高
– 照度不足,无法承办正式比赛
– 电费太高,希望节能
– 电视转播需要,原灯光不满足
– 灯具老化,光衰严重

KITOZER会先现场评估,给出”继续使用”和”改造”两种建议,不强行推销。

R.2 “LED灯会不会有紫外线伤害运动员?”

不会。LED是固态冷光源,光谱集中在可见光区,几乎不发射紫外线和红外线,比金卤灯和太阳灯安全得多。

R.3 “改造期间能继续营业吗?”

可以。KITOZER分区分段施工,通常安排夜间闭馆后作业,白天正常营业。整个改造周期2—4周。

R.4 “为什么有的LED灯用两年就坏了?”

常见原因:
– 驱动电源质量差(电解电容寿命短)
– 散热设计不足,LED芯片光衰快
– 非正规厂家,无老化测试
– 环境恶劣(高温、高湿)没有选对防护等级

KITOZER灯具8年质保就是为了打消这种顾虑。

R.5 “智能控制会不会很复杂,我们物业不会用?”

KITOZER-ISC软件设计非常简洁:
– 日常使用只需要按墙面8键面板切换场景
– 手机APP一键操作
– 复杂设置由KITOZER工程师出厂前预配置好
– 物业人员只需要会”开、关、切换场景”三个操作


Appendix V: Detailed Construction Organization

V.1 Pre-construction

KITOZER project team completes:

Technical:
– Review drawings, lighting design notes, power system diagrams
– Design review with consultant, owner, supervisor
– Prepare construction organization plan
– Technical and safety briefings to crews

Site:
– Survey temp warehouse, material laydown
– Connect temp power (380V 3-phase)
– Safety signage
– Work-at-heights permits

Materials:
– Phased material delivery
– Inspection: certificates, test reports, CCC
– Sampling if required by supervisor

V.2 Conduit Embedding

  • Embed conduits and boxes with rebar during civil phase
  • Bend radius ≥6× OD, no crimping
  • Deburr ends, add grommets after pulling
  • Ceiling conduits layered above HVAC and fire lines
  • Sleeves through walls/floors, fire-stopped

V.3 Fixture Installation

Indoor:
– Panel lights flush with gypsum ceiling
– Heavy fixtures (>3kg) on separate anchors
– Linear lights on threaded rods ≤1.5m spacing
– Power-on test after install

Outdoor floodlights:
– Pre-assemble fixtures on ground before pole lifting
– Pole verticality ≤3‰
– Initial aim by DIALux, fine-tune at night
– Threadlocker on all bolts

Pool:
– Cable entry faces down
– Waterproof loop on cable
– Safe distance from pool edge

V.4 Distribution Panels

  • Floor panel foundation 100mm above floor, waterproof
  • Wall panel bottom at 1.4m
  • Neat breaker arrangement, clear labels
  • Separate neutral and ground busbars
  • Reliable enclosure ground

V.5 Commissioning and Trial Run

  • Loop-by-loop power-on without fixtures, measure voltage
  • Connect fixtures, light up loop by loop
  • DALI bus scan, confirm fixture count
  • Scene switching test
  • Fire linkage test
  • Illuminance test
  • 72-hour continuous trial

V.6 Acceptance Documentation

  • As-built drawings (DWG+PDF)
  • Fixture list and certificates
  • Third-party illuminance report
  • Electrical test records (insulation, ground, phase)
  • Smart control commissioning report
  • O&M manual
  • Training records
  • Acceptance certificate

Appendix W: Common Owner Questions

W.1 “We already have lighting; why change?”

Common reasons:
– Existing MH frequently fails, high maintenance
– Illuminance too low for official competition
– Electricity bills too high, want savings
– TV broadcast requires better lighting
– Fixtures aged, severe decay

KITOZER assesses on site first, advises “keep” vs “retrofit”; no hard sell.

W.2 “Do LEDs emit UV that harms athletes?”

No. LEDs are solid-state cold sources with spectrum concentrated in visible light, almost no UV/IR — safer than MH or sunlight.

W.3 “Can the venue stay open during retrofit?”

Yes. We work zone by zone, usually nights after closing. Total 2–4 weeks.

W.4 “Why do cheap LEDs fail in two years?”

Common causes:
– Poor driver electrolytic caps
– Inadequate thermal design, rapid chip decay
– No-name factory, no burn-in
– Wrong IP rating for harsh environment

KITOZER’s 8-year warranty addresses exactly these concerns.

W.5 “Is smart control too complex for our staff?”

KITOZER-ISC is simple:
– Daily use = wall 8-button scene switching
– Mobile app one-tap
– Complex settings pre-configured by KITOZER engineers
– Staff only need on/off/scene-switch


附录S:体育场馆照明相关国家标准与国际标准索引

S.1 中国国家标准

标准号 标准名称 相关内容
GB 50034-2013 建筑照明设计标准 照度标准值、LPD限值、照明质量
GB/T 35265-2017 体育场馆照明设计及检测标准 场馆照明专项要求
GB 50016-2014(2018版) 建筑设计防火规范 应急照明、疏散指示
GB 51309-2018 消防应急照明和疏散指示系统技术标准 应急照明系统设计施工
GB 17945-2010 消防应急照明和疏散指示系统 应急灯具产品标准
GB 13495.1-2015 消防安全标志 疏散指示标志图形
GB 7000.1-2015 灯具 第1部分:一般要求与试验 灯具安全通用要求
GB 7000.201-2008 灯具 第2-1部分:特殊要求 固定式通用灯具 固定灯具
GB 7000.213-2018 灯具 第2-13部分:特殊要求 地面嵌入灯具 埋地灯
GB/T 24823-2017 普通照明用LED产品 性能要求 LED产品性能
GB/T 24824-2017 普通照明用LED模块 测量方法 LED测量
GB/T 24909-2020 装饰照明用LED灯带 LED灯带
GB/T 31896-2015 LED灯具可靠性加速测试 可靠性
GB/T 36820-2018 半导体照明术语 术语
GB 17625.1-2022 电磁兼容 谐波电流 谐波
GB 17743-2017 电气照明和类似设备无线电骚扰 EMC
GB/T 2423系列 环境试验 高低温湿热盐雾
GB 40054-2021 LED城市道路照明应用技术要求 道路照明
GB/T 5700-2008 照明测量方法 现场测量

S.2 国际标准

标准号 名称
CIE 67 Guide for Sports Lighting for TV and Film
CIE 84 Guide for Floodlighting
CIE 117 Discomfort Glare in Interior Lighting
IEC 62386 Digital Addressable Lighting Interface (DALI)
IEC 60598 Luminaires general requirements
IEC 62471 Photobiological safety of lamps
IES LM-79 Electrical and Photometric Measurements of SSL Products
IES LM-80 Lumen Maintenance of LED Light Sources
IES TM-21 Projecting Long Term Lumen Maintenance
EN 13201 Road Lighting
EN 12464-1 Indoor workplace lighting
EN 12193 Sports Lighting (European)
FIFA Football Stadium Lighting Guide 国际足联
FIBA Manual 国际篮联
FINA Rules 国际泳联
ITF Regulations 国际网联
BWF Handbook 世界羽联

附录T:KITOZER服务承诺

T.1 售前承诺

  • 24小时内响应客户咨询
  • 免费提供DIALux照度仿真方案
  • 免费提供初步配置清单和参考报价
  • 可安排工厂参观和样品测试

T.2 售中承诺

  • 严格按合同工期交货
  • 出厂前逐盏老化测试
  • 货物包装牢固,适合长途运输
  • 提供物流跟踪信息

T.3 售后承诺

  • 48小时电话响应
  • 广东省内48小时上门
  • 质保期内非人为损坏免费更换
  • 提供英文/中文操作手册
  • 终身技术支持

T.4 价格承诺

  • 参考价为人民币不含税价(已×2)
  • 增值税专用发票13%
  • 普通发票6%
  • 运费根据距离另计
  • 最终价格以合同为准

Appendix X: Standards Reference Index

X.1 Chinese National Standards

Standard Title
GB 50034-2013 Building lighting design standard
GB/T 35265-2017 Sports venue lighting design and inspection
GB 50016 Code of design on building fire protection
GB 51309-2018 Fire emergency lighting and evacuation indication system
GB 17945-2010 Fire emergency lighting and evacuation indication system
GB 7000.1 Luminaires Part 1: general requirements
GB/T 24823 LED products performance requirements
GB/T 2423 series Environmental testing
GB/T 5700 Lighting measurement methods

X.2 International Standards

Standard Title
CIE 67 Sports lighting for TV and film
CIE 84 Floodlighting guide
IEC 62386 DALI
IEC 60598 Luminaires
IEC 62471 Photobiological safety
IES LM-79 SSL photometric measurements
IES LM-80 LED lumen maintenance
IES TM-21 Projecting long-term LED maintenance
EN 12193 Sports lighting (European)
EN 12464-1 Indoor workplace lighting

Appendix Y: KITOZER Service Commitments

Y.1 Pre-sales

  • 24-hour response to inquiries
  • Free DIALux simulation
  • Free preliminary BoQ and reference quote
  • Factory visits and sample testing available

Y.2 During project

  • On-time delivery per contract
  • 4-hour burn-in per fixture before shipment
  • Export-grade packaging
  • Logistics tracking

Y.3 After-sales

  • 48-hour phone response
  • On-site within Guangdong in 48h
  • Free replacement for non-manufacturing defects in warranty
  • Chinese/English manuals
  • Lifetime technical support

Y.4 Pricing

  • Reference prices are RMB ex-works (×2)
  • VAT special invoice 13%
  • Normal invoice 6%
  • Freight calculated by distance
  • Final price per contract

Appendix Z: Final Contact and CTA

Ready to light your venue?

Contact KITOZER today for a free DIALux simulation and reference quote.

  • Phone/WeChat: +86 18520668845 / +86 13922289957
  • WhatsApp: +86 19068534140
  • Chinese website: www.lain.com.cn
  • English website: www.gdlain.com
  • Address: Zhongrun Industrial Park Chaotian Campus, No. 5 Huashan Road, Shilou, Panyu, Guangzhou, China

KITOZER — Professional LED lighting engineering for stadiums, data centers, and industrial facilities.


附录U:典型项目现场问题处理案例集

U.1 案例:某大学体育馆验收时照度不足

现场情况:
– 大学体育馆改造完成,第三方检测时发现比赛区水平照度只有580lx,设计要求750lx
– 均匀度U1只有0.55,要求0.7

排查过程:
1. 核对灯具数量:按设计图应装48盏工矿灯,现场只装了40盏——施工队漏装8盏
2. 核对灯具功率:合同约定200W,现场实测有6盏是150W型号(仓库发错货)
3. 核对灯具角度:部分灯具角度偏了15度,光斑没有对准比赛区

整改措施:
– 补装8盏200W工矿灯
– 更换6盏错发的150W为200W
– 重新精调所有灯具角度
– 复测后水平照度820lx,U1=0.72,通过验收

教训:施工时必须逐灯核对型号、功率、安装位置,不能依赖施工队自觉。KITOZER现场工程师在关键节点必须到场验收。

U.2 案例:游泳馆三防灯进水

现场情况:
– 游泳馆运行半年后,有3盏三防灯出现水雾
– 业主投诉

排查:
1. 检查接线口方向:有2盏灯接线口朝上装了(错误方向)
2. 检查电缆入口防水接头:1盏灯的防水接头没拧紧
3. 检查灯具密封圈:1盏灯的密封圈安装时被压偏

整改:
– 重新调整灯具方向,接线口一律朝下
– 更换所有防水接头,按力矩要求拧紧
– 重新安装密封圈,涂硅脂
– 教物业定期检查

教训:游泳馆三防灯安装方向是关键,接线口必须朝下。施工时要在每盏灯旁贴警示标签。

U.3 案例:DALI系统通讯不稳定

现场情况:
– 智能控制系统运行一个月后,部分灯具偶尔离线
– 重启网关后恢复,但过几天又出现

排查:
1. 检查DALI总线电压:空闲时16V正常
2. 检查总线长度:最长一条总线280m,接近300m极限
3. 检查末端终端电阻:发现有一条总线没接10kΩ电阻
4. 检查总线与电力线间距:有一段DALI线与220V电力线同管敷设了3米

整改:
– 在最长总线末端加10kΩ电阻
– 把DALI线从电力线管里抽出来,单独穿管
– 280m长总线加DALI中继器

教训:DALI总线布线必须严格按规范,与电力线分管,末端加电阻。KITOZER在施工图纸上要明确标注这些要求。

U.4 案例:应急灯电池早期失效

现场情况:
– 某场馆验收后一年,有20%应急灯按测试按钮不亮
– 拆开检查,电池电压只有6V(额定12V)

原因分析:
1. 该场馆配电间温度常年40℃以上(靠近空调外机)
2. 应急灯电池在高温下浮充,加速老化
3. 部分电池出厂时就已经是库存超过半年的旧电池

整改:
– 更换全部失效电池
– 在配电间增加通风降温
– 要求供应商发新生产日期电池
– 教物业每季度做一次放电测试

教训:应急灯电池对温度敏感,必须装在通风良好的位置。KITOZER在设计时要与业主确认应急灯安装位置的环境温度。

U.5 案例:室外投光灯台风后角度偏移

现场情况:
– 广东台风后,某室外足球场有12盏投光灯角度偏移
– 比赛区照度分布变化

排查:
1. 检查灯具支架螺栓:有8颗螺栓松动
2. 检查灯杆顶部灯架:有2个灯架焊缝开裂
3. 检查灯具遮光罩:3个遮光罩被风吹掉

整改:
– 复紧所有螺栓,涂螺纹锁固胶
– 焊接修复开裂灯架
– 重新安装遮光罩
– 制定台风季前检查制度

教训:台风地区必须在台风季前做一次全面检查,螺栓复紧、焊缝检查。KITOZER推荐在合同中加入年度巡检服务。


Appendix AA: On-Site Problem Resolution Cases

AA.1 University Gymnasium Illuminance Shortfall

Situation: After retrofit, third-party measured 580 lx vs required 750 lx; uniformity U1 0.55 vs required 0.7.

Investigation:
1. Should be 48 high-bays, only 40 installed — 8 missing
2. Six fixtures were 150W instead of contracted 200W (warehouse shipping error)
3. Some fixture angles off by 15°, light pools misaligned

Correction:
– Added 8×200W high-bays
– Replaced 6×150W with 200W
– Re-aimed all fixtures
– Re-measured: 820 lx, U1=0.72, passed

Lesson: Verify every fixture model, wattage, and position on site. KITOZER engineers must witness key milestones.

AA.2 Swimming Pool Tri-Proof Water Ingress

Situation: After six months, three tri-proof fixtures had condensation.

Investigation:
1. Two fixtures had cable entry facing up (wrong orientation)
2. One gland not tightened
3. One gasket misaligned

Correction:
– Reorient all fixtures with entry down
– Replace glands, torque properly
– Reinstall gaskets with silicone grease
– Train property staff

Lesson: Pool tri-proof entry must face down; label each fixture.

AA.3 Unstable DALI Communication

Situation: After a month, some fixtures occasionally offline; gateway reboot fixes temporarily.

Investigation:
1. Bus voltage 16V idle OK
2. Longest bus 280m, near 300m limit
3. One bus missing 10kΩ terminator
4. One DALI run shared 3m with 220V power

Correction:
– Add 10kΩ terminator
– Separate DALI from power conduit
– Add DALI repeater on 280m run

Lesson: DALI wiring must follow specs; KITOZER drawings must explicitly call these out.

AA.4 Early Emergency Battery Failure

Situation: One year after acceptance, 20% emergency lights fail test button; battery reads 6V (rated 12V).

Cause:
1. Distribution room temperature >40°C (near AC outdoor unit)
2. Float charging at high temp accelerated aging
3. Some batteries were >6 months old in stock

Correction:
– Replace all failed batteries
– Add ventilation to distribution room
– Require fresh-date batteries
– Quarterly discharge test training

Lesson: Emergency batteries are temperature-sensitive; KITOZER must confirm installation ambient temperature.

AA.5 Outdoor Floodlight Aim Drift After Typhoon

Situation: After a Guangdong typhoon, 12 floodlights on an outdoor football pitch shifted angle.

Investigation:
1. 8 bracket bolts loose
2. 2 gantry welds cracked
3. 3 hoods blown off

Correction:
– Re-torque all bolts with threadlocker
– Weld-repair gantry
– Reinstall hoods
– Establish pre-typhoon inspection

Lesson: Typhoon regions need pre-season inspection; KITOZER recommends annual inspection service in contract.


End of appendix. Thank you for reading the KITOZER Stadium LED Lighting Engineering Design Guide. Contact +86 18520668845 for your project.


附录V:场馆照明节能改造合同关键条款建议

V.1 改造范围条款

业主与KITOZER签订照明改造合同时,应明确以下范围:
– 拆除哪些旧灯具、旧配电箱、旧线缆
– 新装哪些灯具、数量、型号、功率
– 是否包含智能控制系统
– 是否包含EPS应急电源
– 是否包含管线桥架
– 是否包含旧料清运
– 是否包含第三方检测费用

V.2 验收标准条款

合同应约定验收依据:
– GB/T 35265-2017《体育场馆照明设计及检测标准》
– GB 50034-2013《建筑照明设计标准》
– 合同约定的目标照度值(如比赛区750lx,均匀度U1≥0.7)
– 第三方检测机构由双方共同认可
– 检测费用由谁承担(通常业主承担,不合格则KITOZER承担整改+复检费)

V.3 节能保证条款

KITOZER可以在合同中承诺节能率:
– 改造后年电费比改造前下降X%
– 连续测量12个月,未达标则退还相应比例款项
– 节能率计算口径(运行时间、电价、是否含智能控制)

V.4 质保条款

  • LED灯具质保5年(室外8年)
  • 质保期内光衰≤20%
  • 驱动电源质保3年
  • 智能控制系统软件质保3年,免费升级
  • 响应时间:48小时电话响应,广东省内48小时上门

V.5 付款条款

  • 合同签订后预付30%
  • 货到现场付60%
  • 验收合格后付10%(质保金可留5%一年后付)

V.6 工期条款

  • 明确开工日期和竣工日期
  • 因业主原因(场地不具备、图纸变更、付款延迟)工期顺延
  • 因KITOZER原因延误,按日支付违约金(通常合同额0.1%/天)

附录W:KITOZER项目报价单模板说明

一份完整的KITOZER场馆照明报价单应包含:

  1. 项目基本信息:项目名称、地点、客户、报价日期、有效期
  2. 技术方案概述:照度等级、灯具型号、控制方式
  3. 详细配置清单:序号、产品名称、型号、数量、单位、单价、合价
  4. 参考总价:合计金额,注明已×2参考价、不含税、不含运费
  5. 商务条款:付款方式、交货周期、质保、运输
  6. 技术偏差表:逐条响应招标文件技术要求
  7. 公司资质:营业执照、ISO9001、CCC、检测报告
  8. 联系人:销售工程师、电话、邮箱

KITOZER在投标阶段会提供完整的Word版和Excel版报价单,配合DIALux仿真报告。


附录X:常见KITOZER灯具型号速查表

投光灯系列

型号 功率 光通量 光束角 防护 典型应用
KT200W-2026 200W 24,000lm 60°/110° IP66 网球场、通道、近距补光
KT400W-2026 400W 48,000lm 25°/40°/60°/90° IP66 篮球场、网球场、中型场地
KT600W-2026 600W 78,000lm 21°/40°/60° IP66 看台、中大型场地
KT1000W-2026 1000W 130,000lm 14°/21°/40°/60° IP66 足球场、田径场、高杆灯

室内照明系列

型号 功率 光通量 尺寸 应用
HB100W-2026 100W 13,000lm Φ300mm 小空间高天棚
HB150W-2026 150W 19,500lm Φ350mm 健身房、训练馆
HB200W-2026 200W 26,000lm Φ400mm 体育馆比赛区
PL6060-2026 36W 4,320lm 595×595mm 办公室、走廊
PL12060-2026 48W 5,760lm 1195×595mm 大办公室、教室
LN600-2026 18W 2,160lm 600mm 走廊、小空间
LN1200-2026 36W 4,320lm 1200mm 羽毛球馆、车库
DL15W-2026 15W 1,350lm Φ100mm 卫生间、楼梯间

三防与应急系列

型号 功率 防护 应用
TP18W-2026 18W IP65 车库、仓库
TP36W-2026 36W IP65 游泳馆、浴室
EM5W-2026 5W(3W应急) IP30 疏散通道
EX3W-2026 3W IP30 安全出口

控制与配电系列

型号 说明
ISC-V1-2026 智能照明控制平台(软件+硬件)
DG16-2026 DALI网关,16子网1024灯
SP8-2026 8键智能面板
MS24G-2026 24GHz微波雷达感应器
PS10-2026 光照度传感器
PDX500-2026 户外落地配电箱500×1200×350mm
KZX800-2026 室内壁挂配电箱800×1000×220mm
EPS10K-2026 10kVA应急电源
EPS20K-2026 20kVA应急电源
EPS30K-2026 30kVA应急电源

全文完。感谢阅读KITOZER体育场馆LED照明工程设计手册。如需项目报价,请致电18520668845 / 13922289957(微信同号),或WhatsApp: 19068534140。


附录Y:体育场馆照明节能改造案例补充

Y.1 某区体育中心整体改造(2025年)

项目概况:该区体育中心包含一座5000座体育馆、一个室外田径场、一个室外网球场、一个室内游泳馆,总建筑面积20000㎡。原照明全部为2010年建成的金卤灯+荧光灯混合系统,年照明电费约180万元。

改造方案:
– 体育馆:更换为KITOZER-HB200W工矿灯60盏、LN1200线型灯100盏、PL6060面板灯200盏
– 田径场:4根30m高杆,每杆8盏KT400W,共32盏
– 网球场:4根12m灯杆,每杆2盏KT200W,共16盏
– 游泳馆:TP36W三防灯60盏
– 智能控制:KITOZER-ISC-V1全套,覆盖所有区域
– EPS:30kVA一套

改造后:
– 实际运行总功率从180kW降到55kW(智能调光后)
– 年照明电费降到约50万元
– 节能率72%
– 改造总投资(已×2)约380万元
– 投资回收期约3.5年

Y.2 某企业员工活动中心(2026年新建)

项目概况:企业内部员工活动中心,含篮球场2片、羽毛球场地4片、健身房1个、乒乓球室1个、员工餐厅。

配置:
– 篮球场:HB200W工矿灯24盏
– 羽毛球馆:LN1200线型灯32盏
– 健身房:PL6060面板灯20盏
– 乒乓球室:LN600线型灯12盏
– 餐厅:PL12060面板灯16盏
– 智能控制:ISC-V1一套
– 总投资(已×2)约65万元

特色:
– 与企业考勤系统联动,工作日下班后自动降到安保模式
– 周末预约打球的员工扫码开门,灯光自动开启
– 员工餐厅用餐时段自动调暖光

Y.3 某学校体育楼(2026年)

学校体育楼含篮球馆、乒乓球馆、器材室、淋浴间。
– 篮球馆:HB200W×16
– 乒乓球馆:LN1200×20
– 淋浴间:TP36W三防灯×10
– 走廊应急灯:EM5W×20
– 投资约25万元

学校项目特点:预算有限,但寒暑假可以充分施工。KITOZER在暑假期间4周完成全部改造,开学即投入使用。


附录Z:结语与联系

体育场馆照明是一门跨光学、电气、建筑、体育工艺的综合学科。一盏好灯背后,是光效、配光、散热、驱动、控制、安装、维护等十几个环节的系统集成。KITOZER作为广州莱安旗下品牌,专注于数据中心、体育场馆、工业照明领域十余年,希望用可靠的产品、专业的设计、贴心的服务,为每一个场馆提供”照得亮、照得匀、照得久、省电费”的照明系统。

如果您正在规划新馆建设、旧馆LED改造、或者需要一份免费的DIALux照度仿真方案,欢迎随时联系我们。我们的技术团队会在24小时内回复,并根据您的场地尺寸、使用等级、预算范围,提供量身定制的方案。

联系方式:
– 手机/微信:18520668845 / 13922289957
– WhatsApp:+86 19068534140
– 中文官网:www.lain.com.cn
– 英文官网:www.gdlain.com
– 公司地址:广州市番禺区石楼镇华山路5号中润工业园潮田园区
– 公司名称:广州莱安智能化系统开发有限公司
– 品牌:KITOZER

感谢您阅读本手册。期待与您合作。


附录AA:KITOZER照明工程交付清单与验收表格

AA.1 交付文档清单

项目竣工时,KITOZER向业主交付以下资料:

竣工图纸类:
– 照明竣工平面图(含灯位、回路编号)
– 照明配电系统图
– 智能照明控制系统图
– 应急照明系统图
– 灯具安装大样图

资料报告类:
– 灯具产品合格证(逐批)
– IES LM-79光学测试报告
– IP防护等级测试报告
– IK防撞测试报告
– CCC认证证书复印件
– 第三方照度检测报告(现场实测)
– 电气测试记录(绝缘电阻、接地电阻、相序)
– 智能控制系统调试报告

操作维护类:
– 灯具安装使用说明书(中英文)
– 智能照明系统操作手册
– 应急电源操作手册
– 常见故障处理手册
– 备品备件清单

AA.2 验收表格模板

竣工验收时通常填写以下表格:

照度验收记录表:
| 测点编号 | 位置描述 | 设计照度(lx) | 实测照度(lx) | 偏差 | 是否合格 |
|———-|———-|————-|————-|——|———|
| 1 | 场地中心 | 750 | 782 | +4.3% | 合格 |
| 2 | 场地四角 | 750 | … | … | … |

接地电阻测试记录表:
| 测试点 | 设计值(Ω) | 实测值(Ω) | 是否合格 |
|——–|———–|———–|———|
| 1号灯杆 | ≤10 | 4.2 | 合格 |

应急照明测试记录表:
| 测试项 | 设计要求 | 实测结果 | 是否合格 |
|——–|———-|———|———|
| 切换时间 | ≤0.25s | 0.15s | 合格 |
| 应急持续时间 | ≥60min | 65min | 合格 |
| 地面最低照度 | ≥1lx | 2.3lx | 合格 |

AA.3 培训内容

KITOZER对物业人员的培训通常包括:
– 日常开灯关灯操作
– 场景切换方法
– 手机APP安装与使用
– 常见故障判断(灯不亮、闪烁、报警)
– 应急灯月度测试方法
– EPS电池季度放电测试
– 灯具清洁注意事项
– 报修流程与联系方式

培训时间约半天,现场实操与理论结合,确保物业人员能独立处理日常问题。


附录AB:KITOZER与行业常见问题补充

AB.1 LED灯可以调多暗?

KITOZER DALI-2驱动可以从满功率平滑调到1%甚至0.1%。但实际工程中建议最低不要低于5%,因为极低亮度下LED灯珠的电流极小,驱动电源的恒流精度会下降,可能出现频闪。KITOZER在场景设计时通常把”安保模式”设为5%—10%亮度,而不是完全关闭。

AB.2 灯具可以使用多少个开关周期?

LED灯具没有机械灯丝,开关寿命几乎不受开关次数影响。理论上每天开关10次,可以用几十年。但频繁开关对驱动电源的电容有一定冲击,KITOZER驱动设计支持每天100次以上开关循环。智能照明系统建议用调光代替频繁开关,既保护灯具又提升舒适度。

AB.3 不同色温的灯可以混装吗?

技术上可以,但视觉上会明显看到色差。KITOZER建议同一区域使用同一批次、同一色温的灯具。如果需要不同色温分区(如比赛区5700K、休息区3000K),应在设计时明确分区,不要在同一区域混装。

AB.4 灯具坏了可以直接换别的品牌吗?

不建议。不同品牌灯具的配光曲线、光学效率、安装尺寸、DALI地址都不同。混装会导致照度不均、亮度差异、控制混乱。KITOZER建议在质保期内使用原厂备件。


全文终。KITOZER体育场馆LED照明工程设计手册到此结束。如需咨询,请致电18520668845 / 13922289957(微信同号),WhatsApp: 19068534140,或访问www.lain.com.cn / www.gdlain.com。


附录AC:KITOZER服务流程总结

KITOZER场馆照明项目从初次接触到最终交付,通常经历以下完整流程:

第一步,客户通过电话、微信、WhatsApp或官网留言联系KITOZER销售工程师,说明项目背景和需求。销售工程师在24小时内回复,初步了解场地类型、面积、照度等级、预算范围和工期要求。

第二步,技术工程师根据客户提供的场地尺寸和使用等级,在DIALux软件中进行照度仿真,出具初步的灯具布置方案和参考配置清单。这个过程通常需要1到3个工作日。

第三步,对于广东省内或较大项目,KITOZER安排技术人员现场勘测,实地测量场地尺寸、观察顶棚结构、查看现有配电系统,拍照记录。现场勘测后3个工作日内更新方案。

第四步,双方确认方案和参考报价,签订正式合同,客户支付预付款。KITOZER开始深化设计,出具施工图纸。

第五步,工厂排产。常规灯具7到15天发货,定制型号25到35天。所有灯具出厂前经过4小时老化测试。

第六步,材料进场,施工队伍开始安装管线、灯具、配电箱。KITOZER现场工程师在关键节点到场检查。

第七步,通电调试。逐回路测试、DALI总线寻址、场景切换测试、消防联动测试。

第八步,第三方检测机构现场测量照度,出具检测报告。各项指标达标后组织竣工验收。

第九步,对物业人员进行操作培训,交付竣工资料。

第十步,进入质保期。KITOZER提供48小时电话响应,广东省内48小时上门服务,每季度电话回访,每年现场巡检一次。

整个流程体现了KITOZER从设计、生产、施工到售后的一站式交付能力。业主只需要对接KITOZER一个团队,就能完成整个场馆照明工程。


附录AD:关于KITOZER品牌

KITOZER是广州莱安智能化系统开发有限公司旗下品牌,专注于智能照明、数据中心基础设施、工业配电领域。公司位于广州番禺石楼华山路5号中润工业园潮田园区,拥有自己的生产车间、SMT贴片线、整灯组装线和老化测试区。KITOZER品牌产品覆盖LED投光灯、面板灯、线型灯、三防灯、应急灯、智能控制系统、EPS应急电源、配电箱等全系列。公司通过ISO9001质量管理体系认证,产品通过CCC、CE、RoHS等认证,服务国内和海外客户。中文客户请访问lain.com.cn,海外客户请访问gdlain.com。销售热线18520668845,微信同号,WhatsApp 19068534140。期待与您的合作。

本手册由KITOZER技术部编制,内容涵盖场馆照明从技术原理、标准规范、产品选型、智能控制、电气设计、安装调试、节能测算、案例分析到售后服务的完整链条。无论您是业主、设计院工程师、体育场馆运营方还是电气施工方,都可以在本手册中找到有价值的参考信息。KITOZER团队将持续更新本手册,跟踪最新的照明技术和标准变化,为客户提供更专业的服务。如需获取最新版本或技术支持,请随时联系我们。

感谢您选择KITOZER,我们将以专业的技术、可靠的产品和用心的服务,助力每一座场馆照亮精彩赛事。
期待与您携手合作共赢。

Shopping Cart