KITOZER PDU Power Distribution Unit: Rack Mount Smart Metered Switched Guide

KITOZER PDU Power Distribution Unit: Complete Guide

KITOZER PDU (Power Distribution Unit) distributes AC power to servers and IT equipment in data centers, telecom rooms, and server racks. KITOZER offers basic, metered, monitored, switched, and intelligent PDU models from 1U to 3U, single-phase and three-phase, C13/C19 outlets, with surge protection, remote monitoring, and per-outlet metering.

PDU Types

  • Basic PDU: Pass-through power distribution, no monitoring. Cost-effective.
  • Metered PDU: Input voltage/current display, rack-level monitoring.
  • Monitored PDU: Remote monitoring via SNMP/Web, no outlet switching.
  • Switched PDU: Remote outlet on/off control, reboot capability.
  • Intelligent PDU: Per-outlet current metering + outlet switching + environmental sensors.

KITOZER PDU Product Line

Model Power Type Outlets Reference Price
KZ-PDU-16A-B 16A Basic 8x C13 $85
KZ-PDU-16A-M 16A Metered 8x C13 $180
KZ-PDU-32A-M 32A Metered 12x C13+4x C19 $320
KZ-PDU-32A-S 32A Switched 12x C13+4x C19 $580
KZ-PUD-63A-I 63A Intelligent 24x C13+6x C19 $1,200
KZ-PUD-3PH-125A 3-phase 125A Intelligent 36x C19 $2,200

PDU vs Power Strip

A PDU is rack-mounted, rated for continuous data center duty, with surge protection, current monitoring, and remote management. A power strip is consumer-grade, wall-mounted, without monitoring.

Key Specifications

  • Input: 100–240V single-phase or 380V three-phase
  • Current: 10A–125A
  • Outlets: C13/C19/NEMA/CEE/IEC
  • Monitoring: Voltage, current, power, energy, temperature, humidity
  • Communication: RJ45 Ethernet, SNMP v2c/v3, Modbus TCP, REST API
  • Mounting: 19-inch rack, vertical or horizontal
  • Certification: CE, UL, RoHS

Selection Guide

Calculate total rack load, select current rating with 20% margin, choose outlet type matching server power cords, decide monitoring level based on remote management needs.

FAQ

Q1: What is a smart PDU? A: A PDU with remote monitoring and outlet control via network.

Q2: How many outlets do I need? A: Count server power supplies plus redundancy, add 20% spare.

Q3: PDU vs UPS? A: PDU distributes power; UPS provides battery backup.

Q4: Three-phase PDU benefits? A: Higher power density, balanced load, lower current per phase.

Q5: Does PDU save energy? A: Smart PDU with outlet control reduces idle load and enables power capping.