ToggleKITOZER SVG Static Var Generator: Reactive Power & Harmonic Compensation Guide
KITOZER SVG (Static Var Generator) is a next-generation power quality device based on IGBT voltage-source converters. It detects load reactive current in real-time and injects compensating current in anti-phase, correcting power factor to 0.99, suppressing harmonics, and balancing three-phase unbalance in under 5 milliseconds. KITOZER covers 30 kvar to 10 Mvar, low-voltage 400V and high-voltage 10kV/35kV, wall-mount and cabinet types.
1. SVG Working Principle
The main circuit is a three-phase voltage-source converter (VSC) with DC-side capacitor energy storage. IGBT switches operate at 10–20 kHz SPWM, generating a controllable AC voltage source through a coupling reactor. By adjusting the output voltage amplitude and phase relative to grid voltage, the SVG absorbs or injects reactive current continuously.
Control: d-q coordinate transformation extracts active/reactive components. The DSP controller closes the current loop at 10 kHz bandwidth. Response time: <5 ms from load step to full compensation. Range: -100% (inductive) to +100% (capacitive) rated capacity, stepless.
2. SVG vs Traditional Compensation
| Item | Capacitor Bank | SVC (TCR+FC) | SVG | APF |
|---|---|---|---|---|
| Response time | 20–40 ms | 10–20 ms | <5 ms | <5 ms |
| Adjustment | Stepped | Nearly continuous | Continuous | Continuous |
| Harmonic handling | None (resonance risk) | Limited | Optional (SVG-H) | Yes (primary) |
| Three-phase unbalance | No | Limited | Yes | Yes |
| Resonance | Prone | Low | None | None |
| Efficiency | >99% | ~97% | >97% | >95% |
| Footprint | Large | Large | Compact | Compact |
| Cost | Low | Medium | Medium-high | High |
3. KITOZER SVG Product Line
| Model | Capacity | Voltage | Installation | Reference Price |
|---|---|---|---|---|
| KZ-SVG-30K | 30 kvar | 400V | Wall/rack | $2,500 |
| KZ-SVG-50K | 50 kvar | 400V | Wall/rack | $4,000 |
| KZ-SVG-100K | 100 kvar | 400V | Cabinet | $7,500 |
| KZ-SVG-200K | 200 kvar | 400V | Cabinet | $14,000 |
| KZ-SVG-300K | 300 kvar | 400V | Cabinet | $20,000 |
| KZ-SVG-500K | 500 kvar | 400V | Parallel cabinets | $31,000 |
| KZ-SVG-1M | 1 Mvar | 10 kV | Cabinet group | $170,000 |
| KZ-SVG-10M | 10 Mvar | 35 kV | Container | $1,200,000 |
4. Sizing Calculation
Reactive power required: Q = P × (tan φ1 − tan φ2)
Where P = active power (kW), φ1 = original power factor angle, φ2 = target power factor angle.
Example: P = 1000 kW, original PF = 0.7, target PF = 0.99.
tan(arccos 0.7) = 1.020; tan(arccos 0.99) = 0.142.
Q = 1000 × (1.020 − 0.142) = 878 kvar → select 1 Mvar SVG.
Add 20% margin for future load growth: 878 × 1.2 = 1054 kvar → 1.2 Mvar.
5. Harmonic Mitigation (SVG-H)
Combined SVG+APF models (KZ-SVG-H) simultaneously compensate reactive power and filter 5th, 7th, 11th, 13th harmonics to THDi <5%. Critical for nonlinear loads: VFDs, rectifiers, UPS, LED drivers, EV chargers.
6. Three-Phase Unbalance Correction
SVG injects negative-sequence current to balance single-phase loads across three phases. Unbalance factor reduces from >10% to <2%. Essential for mixed single/three-phase loads in commercial buildings and charging stations.
7. Applications
- Metalworking: arc furnaces, rolling mills, welders
- Mining: hoists, conveyor VFDs
- Renewables: PV/wind grid-tie inverters
- EV charging: supercharger stations, bus depots
- Data centers: UPS input power factor correction
- Commercial: elevators, HVAC, LED lighting
- Industrial: injection molding, cranes, pumps
8. Installation
Low-voltage SVG: floor-mounted cabinet, busbar or cable connection to LV switchgear. Wall-mount <50kvar. High-voltage: dedicated MV switchgear cubicle, protection relay, step-down transformer. Cooling: forced air ventilation, ambient -10°C to +40°C.
9. Maintenance
Annual: check cooling fans, torque connections, firmware. Every 5 years: capacitor inspection. Every 10 years: fan and DC bus capacitor replacement. Remote monitoring via Ethernet/SNMP.
10. FAQ (60 Questions)
Q1: SVG vs capacitor? A: SVG is continuous, fast, no resonance; capacitor is stepped, slow, resonance-prone.
Q2: SVG vs SVC? A: SVG uses IGBT (faster, more efficient); SVC uses thyristor TCR (slower, generates harmonics).
Q3: SVG vs APF? A: SVG primarily reactive power; APF primarily harmonics. Combined SVG-H does both.
Q4: Response time? A: <5 ms.
Q5: Power factor after compensation? A: 0.99 leading/lagging adjustable.
Q6: Efficiency? A: >97% low-voltage; >98% high-voltage.
Q7: Can SVG handle harmonic? A: SVG-H model; standard SVG does not filter harmonics.
Q8: Does SVG cause resonance? A: No, it actively dampens resonance.
Q9: Three-phase unbalance? A: Yes, corrects to <2%.
Q10: What kvar size? A: Calculate Q = P(tanφ1−tanφ2), add 20% margin.
Q11: Wall or cabinet? A: <50 kvar wall-mount; ≥50 kvar cabinet.
Q12: Parallel operation? A: Yes, up to 10 units parallel for large capacity.
Q13: Communication? A: RS485 Modbus, Ethernet, SNMP.
Q14: Display? A: 7-inch touchscreen showing PF, kvar, harmonics.
Q15: Noise? A: <65 dB (cabinet with fans).
Q16: Operating temp? A: -10 to +40°C.
Q17: Warranty? A: 2 years standard.
Q18: Certification? A: CE, ISO 9001, type test report.
Q19: Lead time? A: 15–30 days.
Q20: Can it retrofit old capacitor bank? A: Yes, replace contactor-switched capacitors with SVG.
Q21: What is thyristor switched capacitor? A: TSC, faster than contactor but still stepped.
Q22: What is TCR? A: Thyristor Controlled Reactor, part of SVC.
Q23: Why PF correction? A: Avoid utility penalty, reduce line losses, release transformer capacity.
Q24: What is power factor? A: Ratio kW/kVA; ideal = 1.0.
Q25: What causes low PF? A: Inductive loads: motors, transformers, welders.
Q26: Utility PF penalty? A: Typically PF<0.9 triggers surcharge in China.
Q27: ROI? A: 2–3 years from penalty savings and loss reduction.
Q28: What is THDi? A: Total Harmonic Distortion of current; target <5%.
Q29: Main harmonics? A: 5th (250Hz), 7th (350Hz), 11th (550Hz), 13th (650Hz).
Q30: Can SVG replace APF? A: If harmonics are moderate, SVG-H suffices; for heavy harmonics use APF.
Q31: What is step response? A: Time to reach 90% compensation after load step: <5 ms.
Q32: Oversizing? A: Add 20% for future load; undersizing leaves PF penalty.
Q33: Low voltage ride-through? A: Optional for HV applications.
Q34: Isolation transformer? A: Required for 10kV/35kV direct SVG.
Q35: Cable size? A: Based on rated current; consult KITOZER.
Q36: Protection? A: Input MCB, fuse, overcurrent/overtemp/overvoltage protection.
Q37: Redundancy? A: N+1 parallel for critical loads.
Q38: What if SVG fails? A: Bypass contactor switches load to direct feed; no outage.
Q39: Remote monitoring? A: Web/SNMP/Modbus; alarm via email/SMS.
Q40: Firmware update? A: Via Ethernet or USB.
Q41: What is DC capacitor? A: Energy storage on DC bus; lifetime 100k hours.
Q42: IGBT brand? A: Infineon/Siemens quality.
Q43: Cooling? A: Forced air; derate above 40°C.
Q44: Floor load? A: 200–500 kg/m² depending on cabinet.
Q45: Dimensions? A: 100kvar ~600×600×2000mm; 500kvar ~800×800×2200mm.
Q46: Color? A: RAL 7035 grey standard.
Q47: IP rating? A: IP20 indoor; IP54 outdoor option.
Q48: What is derating? A: Reduce capacity above 40°C ambient or 1000m altitude.
Q49: Can it work with generator? A: Yes, helps stabilize generator voltage.
Q50: PV self-consumption? A: SVG supports PV inverter PF control.
Q51: EV charger impact? A: SVG stabilizes grid at charging stations.
Q52: What is flicker? A: Voltage fluctuation from welders/arc furnaces; SVG reduces flicker.
Q53: IEEE 519 compliance? A: SVG-H helps meet IEEE 519 harmonic limits.
Q54: GB/T 14549? A: China harmonic standard; SVG-H ensures compliance.
Q55: What is dynamic reactive? A: Fast-changing reactive load (welders, elevators) needing fast compensation.
Q56: Static vs dynamic? A: Capacitor for static; SVG for dynamic loads.
Q57: Can SVG be retrofitted? A: Yes, parallel to existing bus, no downtime.
Q58: What is TCO? A: Total cost: higher capex but lower losses and penalties.
Q59: Training? A: Commissioning and operator training included.
Q60: Contact? A: Tel/WeChat +86 13922289957, +86 18520668845; WhatsApp +86 19068534140.