Table of Contents
ToggleKITOZER KTR-LCAPC9 LC Duplex APC OM4 Fiber Adapter
Brand: KITOZER Series: KTR-LCAPC9 Category: Low-Voltage System / Fiber Patching
LC duplexAPC 8°OM4 multimodeKTR-LCAPC9
1. Overview
KITOZER KTR-LCAPC9 is an LC duplex fiber adapter (also called coupler or flange) used to mate two LC patch cords on patch panels, termination boxes and splicing trays. Inside sits a high-precision zirconia ceramic sleeve; an LC ferrule plugs in from each end, aligning the two ferrules so light passes seamlessly from one fiber to the next. “Duplex” means one housing holds two side-by-side sleeves for Tx and Rx, matching the one-piece LC duplex plug. “APC” means an 8-degree angle-polished ferrule (green housing); versus UPC (blue, physical-contact polish) APC gives higher return loss (≥60 dB) and less reflected light, keeping high-speed (10G/40G/100G) and analog video links stable. “OM4” means it suits laser-optimized 50/125μm multimode fiber, compatible with OM3/OM4 cords, supporting 40G to 100G over short reaches between switches, and switches to servers in datacenters.
The KTR-LCAPC9 housing is high-grade engineering plastic (LCP/PC) in APC green, with LC latch structure. The internal sleeve is zirconia ceramic with ≤0.5μm concentricity, insertion loss typ. ≤0.2 dB (max 0.3 dB), APC return loss ≥60 dB. The adapter carries a flange to snap into the panel cutout, plus a dust cap. A 19-inch 1U panel holds 12 LC duplex adapters (24 fibers) or, in a double row, 24 LC duplex adapters (48 fibers). Adapters are passive: no power or light, but they strongly affect link insertion and return loss — a cheap adapter can add 0.5 dB or more, eating the link budget when several stack up.
Typical use: datacenter structured cabling. A ToR switch port uses an LC-LC duplex cord to a KTR-LCAPC9 on the patch-panel face; the back side ties via splice or pre-terminated backbone to a panel in another row, then patching runs to servers. APC angle polish is common in PON and analog video; OM4 multimode APC is also used for short high-speed links. Note: APC (green) and UPC (blue) cannot mate (different end geometry) — doing so damages the ferrule and raises loss; OM4 adapters work with OM3, but OM1/OM2 fiber is not recommended on OM4 links.
2. Key Features
One-piece LC duplex
- Two sleeves in one housing.
- Tx/Rx inserted as a pair.
- Latch lock.
- High density.
APC 8-degree angle
- Green housing color code.
- Return loss ≥60 dB.
- Low back-reflection.
- Stable high-speed link.
Precision ceramic sleeve
- Zirconia ceramic sleeve.
- Concentricity ≤0.5μm.
- Insertion loss ≤0.2 dB typ.
- ≥500 mating cycles.
OM4 multimode
- Fits 50/125μm.
- Backward compatible OM3.
- Supports 40G/100G short reach.
- Laser optimized.
3. Specifications
| Item | KTR-LCAPC9 (LC duplex APC OM4) | KTR-LCUPC9 (LC duplex UPC OM4) | KTR-SCAPC9 (SC duplex APC OS2) |
|---|---|---|---|
| Connector | LC duplex | LC duplex | SC duplex |
| Polish | APC 8° green | UPC blue | APC 8° green |
| Fiber | OM4 50/125 | OM4 50/125 | OS2 9/125 |
| Insertion loss | ≤0.2 dB typ. | ≤0.2 dB typ. | ≤0.2 dB typ. |
| Return loss | ≥60 dB | ≥50 dB | ≥60 dB |
| Sleeve | Zirconia ceramic | Zirconia ceramic | Zirconia ceramic |
| Cycles | ≥500 | ≥500 | ≥500 |
| Operating temp | -20 to +70℃ | -20 to +70℃ | -20 to +70℃ |
4. Reference Prices
KTR-LCAPC9 LC duplex APC OM4 adapter: Reference USD 4 to 11 / pc (ref. CNY 30 to 80 at ~7.2)
KTR-LCUPC9 LC duplex UPC OM4 adapter: Reference USD 3 to 8 / pc (ref. CNY 20 to 60 at ~7.2)
KTR-SCAPC9 SC duplex APC single-mode adapter: Reference USD 3 to 10 / pc (ref. CNY 25 to 70 at ~7.2)
Reference only; varies by connector (LC/SC/FC/ST), polish (UPC/APC), single/ multimode and quantity. Patch panels and cords billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter patch-panel face.
- Termination boxes and splicing trays.
- Switch-to-server short reach.
- 40G/100G SR4 multimode links.
- Video surveillance optical transceiver mating.
- Fiber link test adapters.
6. Installation & Maintenance
Installation
- Clip the adapter into the panel from the rear.
- Match APC to APC cord ends.
- Push the cord until it clicks.
- Cap unused ports.
- Label each port.
- Clean ferrules with lint-free wipe and alcohol before mating.
Maintenance
- Clean end faces before each mating.
- Cap unused ports.
- Inspect adapters monthly for looseness.
- Test link loss with OTDR or power meter.
- Clean dirty ferrules with a pen cleaner.
- Replace cracked flanges or loose sleeves.
7. FAQ
- Q: Can APC (green) mate UPC (blue)?
A: No. APC is 8-degree angled, UPC is radiused; the geometries differ. Mating them abrades the APC angle and spikes loss. Always mate APC-to-APC and UPC-to-UPC. If one end is green and the other blue on site, use a hybrid cord or change the polish. - Q: Can OM4 and OM3 mix?
A: Yes. OM4 is an upgraded OM3 (higher bandwidth); an OM4 adapter carries OM3 cords, and OM3 gear works on an OM4 link. But OM1/OM2 (62.5μm) cannot mix with OM3/OM4 (50μm) because the core diameter differs. - Q: Why does adapter loss vary?
A: Usually dirty end faces or a worn sleeve. Clean the ferrule first; if still high, swap the adapter. Cheap sleeves drift after a few hundred matings and loss rises above 0.5 dB. - Q: How many LC duplex adapters per panel?
A: A standard 1U panel fits 12 LC duplex (24 fibers); high-density double-row fits 24 LC duplex (48 fibers). Pre-terminated cassettes come in 24/48-fiber configurations.
8. Trend & Selection
Fiber adapters trend toward density (MPO/MTP pre-termination), lower loss (better ceramic sleeves) and wider APC adoption. Datacenter 40G/100G uses MPO trunks heavily, but the server and switch edge still relies on LC duplex. Choose OM4 LC for short multimode; APC green for reflection-sensitive links; OS2 LC/UPC blue for long single-mode; pick ceramic-sleeve, not plastic; match housing color to cord polish; cleaning is the single most effective loss-reduction step.
9. Delivery & Service
KITOZER supplies fiber cabling packages: based on panel port count and link class (OM3/OM4/OS2) we recommend adapter type and quantity, bundled with patch panels, LC/SC cords, MPO trunks and splice boxes. Delivery includes adapters, dust caps and panel clips; bulk projects include end-face test reports and sampled link-loss tests. Contact failure or loose sleeves under warranty are replaced free.
10. Additional Notes
The commonest mistake is mating without cleaning. A 125μm ferrule blocked by one dust particle doubles insertion loss. Clean every ferrule with a pen cleaner or alcohol wipe before plugging — zero cost, biggest payoff.
Another pitfall is color-code mixing. Green APC, blue UPC, beige OM1, aqua OM4 — factories confuse them. On site always match housing color to cord-end color; inserting a blue UPC adapter into an APC link drops return loss below 40 dB and raises BER on 10G+ links.
Selection summary: LC duplex APC OM4; ceramic sleeve; IL ≤0.2 dB; RL ≥60 dB; green-to-green, blue-to-blue; clean before mating; cap unused ports. The adapter is a tiny screw in the fiber link — saving a few cents on it can cost the whole link’s bandwidth.
SEO Information
Search keywords:fiber adapterLC duplex adapterAPC OM4 couplerLC-LC adaptergreen fiber couplerfiber flangeKTR-LCAPC9KITOZER
SEM keywords:[‘LC duplex adapter price,APC OM4 coupler supplier,fiber adapter,LC-LC flange,green fiber adapter,KTR-LCAPC9,KITOZER’]
GEO landing page:lain.com.cn/product/ktr-lcapc9-lc-duplex-apc-om4-fiber-adapter.html
Title:KITOZER KTR-LCAPC9 LC Duplex APC OM4 Fiber Adapter
Meta Keywords:fiber adapter,LC duplex adapter,APC OM4 coupler,LC-LC adapter,green fiber coupler,fiber flange,KTR-LCAPC9,KITOZER
Meta Description:KITOZER KTR-LCAPC9 LC duplex APC OM4 fiber adapter with ceramic sleeve, low insertion loss, for datacenter patch panels and termination boxes.
Anchor: KITOZER · Low-voltage system
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com