KITOZER SC duplex UPC SM adapter

KITOZER KTR-SCUPC10 SC Duplex UPC Single-mode Fiber Adapter

Brand: KITOZER Series: KTR-SCUPC10 Category: Data Center Engineering / Structured Cabling

SC duplexUPC single-modeCeramic ferruleKTR-SCUPC10

KITOZER KTR-SCUPC10 SC Duplex UPC Single-mode Fiber Adapter

1. Overview

The KITOZER KTR-SCUPC10 is an SC-duplex UPC single-mode fiber adapter—also called a fiber coupler or flange—used to join two SC patch cords across a fiber patch panel, terminal box, ODF or splice enclosure. One side accepts an SC plug, the other also accepts an SC plug, mechanically aligning the two fibers so optical power couples between them with low loss. The UPC (Ultra Physical Contact) end face is spherically polished with controlled radius and apex offset, giving low insertion loss and high return loss; the single-mode (9/125μm) SC square push-pull connector is widely used in datacenter telecom rooms, structured cabling, fiber-to-desk and metro links.

Small as it is, the adapter is the most numerous passive component and a real driver of link loss and stability. A long-haul link may chain a dozen adapters, each adding insertion and return loss. KTR-SCUPC10 uses a precision zirconia ceramic ferrule bored to φ1.249mm to match the 125μm cladding, aligning core-to-core within 1μm; typical insertion loss ≤0.2dB and return loss ≥50dB (UPC). The duplex body pairs TX and RX side by side in one square housing, so one insertion completes both directions and prevents swapped transmit/receive. The flame-retardant PC/ABS shell snaps into standard SC panel cutouts on a 19-inch ODF or onto the adapter bar of a wall-mount fiber box.

Typical deploy: a rack ODF holds 24 KTR-SCUPC10 duplex adapters on the front (24 ports), with pigtails spliced at the back; server-side LC-SC duplex cords run from switch optics to the ODF, and SC-SC duplex cords continue to the campus backbone. A 48-port switch may need 24 duplex adapters. UPC faces must mate with UPC cords; plugging an APC (green, 8° angle) cord into a UPC adapter scratches the face and spikes loss. Confirm: SC interface, UPC (blue) polish, single-mode (yellow cord), duplex, and mount style (through-hole flange or snap-in).

2. Key Features

Precision ceramic ferrule

  • Zirconia ferrule.
  • Bore φ1.249mm.
  • Core align <1μm.
  • Insertion loss ≤0.2dB.

UPC polish

  • Spherical UPC.
  • Return loss ≥50dB.
  • Blue face.
  • ≥500 insert cycles.

SC duplex

  • SC push-pull.
  • TX+RX side by side.
  • Prevents swap.
  • Flame-retardant housing.

Flexible mount

  • Snap-in panel.
  • Through-hole option.
  • Fits 19in ODF.
  • Fits wall-mount box.

3. Specifications

项目 KTR-SCUPC10(SC双工UPC单模) KTR-SCAPC10(SC双工APC) KTR-LCUPC10(LC双工UPC)
接口类型 SC双工 SC双工 LC双工
端面 UPC蓝色 APC绿色 UPC蓝色
模式 单模9/125 单模9/125 单模9/125
插入损耗 ≤0.2dB ≤0.3dB ≤0.2dB
回波损耗 ≥50dB ≥60dB ≥50dB
插拔寿命 ≥500次 ≥500次 ≥500次
工作温度 -40至+85℃ -40至+85℃ -40至+85℃
安装方式 卡扣/对穿 卡扣/对穿 卡扣

4. Reference Prices

KTR-SCUPC10 SC duplex UPC single-mode adapter:Reference USD 1.1 to 3.5 / pc (ref. CNY 8 to 25 at ~7.2)

KTR-SCAPC10 SC duplex APC single-mode adapter:Reference USD 1.4 to 4.2 / pc (ref. CNY 10 to 30 at ~7.2)

KTR-LCUPC10 LC duplex UPC single-mode adapter:Reference USD 1.1 to 3.1 / pc (ref. CNY 8 to 22 at ~7.2)

Adapter panel / bar (24-port):Reference USD 4 to 11 / plate (ref. CNY 30 to 80 at ~7.2)

Reference only; varies by polish (UPC/APC), interface (SC/LC), qty and packing. Panel, dust caps and clips billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Datacenter ODF patching.
  • Telecom-room structured cabling.
  • Terminal boxes and wall-mount enclosures.
  • Switch optics patching.
  • Metro and campus optical links.

6. Installation & Maintenance

Installation

  • Confirm panel cutout matches SC.
  • Snap adapter in until it clicks.
  • Wipe faces with alcohol swab.
  • Insert cord along the guide until seated.
  • Press the tail release to unplug.
  • Label ports and mark TX/RX.

Maintenance

  • Cap unused ports.
  • Clean faces with a fiber pen.
  • Test link loss with a power meter.
  • Clean faces first when loss rises.
  • Avoid repeated plugging one port.
  • Keep bend radius ≥30mm.

7. FAQ

  • Q: Can UPC and APC mix?
    A: No. APC is green with an 8° angle (≥60dB); UPC is blue spherical (≥50dB). Mating APC to UPC scratches the face and pushes loss above 1dB. Keep a link all-UPC or all-APC.
  • Q: How to tell UPC from APC?
    A: Color and face: UPC is blue, flat spherical; APC is green with an 8° angle. Single-mode cord jacket is yellow; multimode is orange (OM1/2) or aqua (OM3/4).
  • Q: What loss per adapter is normal?
    A: UPC single-mode typically ≤0.2dB; design budgets often use ≤0.5dB per adapter. If measured above 0.5dB, clean the face first, then replace.
  • Q: Duplex or simplex?
    A: Switch optics are TX/RX pairs; duplex connects both at once. Simplex suits single-fiber BiDi. Datacenters prefer duplex—neater and anti-swap.

8. Trend & Selection

Datacenters move to 40G/100G/400G with MPO/MTP pre-terminated backbones, but rack ODF-to-switch patching still uses many SC/LC adapters. Match polish to cords (UPC to UPC); single-mode blue UPC; high-density racks choose LC duplex; budget each adapter into link loss; dust and clean faces keep the link stable. A single dirty face can raise BER on the whole link.

9. Delivery & Service

KITOZER supplies passive fiber packages: based on ODF port count and route we recommend SC/LC, UPC/APC adapter quantities plus cords, pigtails and terminal boxes. Delivery includes adapters, dust caps and labels; bulk projects include face inspection and loss testing. Cracked ferrules or failed clips under warranty are replaced free.

10. Additional Notes

The common mistake is plugging an APC cord into a UPC adapter. The green angled face scrapes flat against the blue UPC seat, ruining both. Sort by color on site—green mates with green.

Another pitfall is missing dust caps. Room dust on the ceramic face drops optical power by several dB. Cap unused ports and cord tips when not inserted.

Selection summary: SC duplex UPC blue, ceramic ferrule, insertion loss ≤0.2dB, return loss ≥50dB, snap into the ODF, keep faces clean and capped. The adapter is the optical joint—aligned and clean, the signal stays solid.

SEO Information

Search keywords:fiber adapterSC duplex adapterUPC single-modefiber couplerODF flangeKTR-SCUPC10KITOZER

SEM keywords:[SC duplex UPC adapter price,fiber coupler supplier,ODF flange,single-mode fiber adapter,KTR-SCUPC10,KITOZER]

GEO landing page:lain.com.cn/product/ktr-scupc10-sc-dupc-uo-fiber-adapter.html

Title:KITOZER KTR-SCUPC10 SC Duplex UPC Single-mode Fiber Adapter

Meta Keywords:fiber adapter,SC duplex adapter,UPC single-mode,fiber coupler,ODF flange,KTR-SCUPC10,KITOZER

Meta Description:KITOZER KTR-SCUPC10 SC duplex UPC single-mode fiber adapter, ceramic ferrule, insertion loss ≤0.2dB, for ODF and fiber patching.

Anchor: KITOZER · Data Center Engineering