Table of Contents
ToggleKITOZER KTR-NSP2 RJ45 Gigabit Network Surge Protector
Brand: KITOZER Series: KTR-NSP2 Category: Power Distribution / Surge Protection
RJ45 gigabitThree-stageIn 5kAKTR-NSP2
1. Overview
The KITOZER KTR-NSP2 is an RJ45 gigabit network signal surge protector (SPD) inserted between the room’s switch/server/firewall Ethernet ports and outdoor or long-run cables, diverting induced lightning and switching surges to protect port chips from breakdown. A three-stage circuit (GDT + MOV + TVS) with RJ45 In/Out series wiring supports gigabit (1000Base-T) over all eight pairs with low insertion loss and no rate impact. The metal housing has DIN-rail mounting for the rack’s earth bar, grounded by a 6mm² yellow-green wire to the room’s equipotential busbar.
Most room lightning damage is indirect—induced surges. A nearby strike induces kilovolt transients on overhead lines, long network runs and power cables, which travel into the room and burn ports and power supplies. The network SPD clamps the surge to a safe residual voltage (~10-15V) at the line entrance and dumps energy to ground. KTR-NSP2: nominal discharge In 5kA (8/20μs), max Imax 10kA, response <1ns, 1Gbps, insertion loss <0.5dB, optional PoE passthrough. Outdoor camera cables, AP feeds and inter-building electrical links should each get a network SPD at the room entrance.
Typical deploy: in the telecom closet, outdoor POE camera and inter-building network lines pass through KTR-NSP2 before the core switch; the SPD snaps on a DIN rail near the rack earth bar with a 6mm² wire to the equipotential busbar. Add one NSP2 per incoming line to key servers and aggregation switches. Note: a network SPD handles differential/common-mode surges only—it does not replace power SPD or direct-strike protection. Power feeds still need a power SPD (KTR-PSP series) and the roof needs air terminals. Three-level coordination—power SPD (main distribution) + signal SPD (network entrance) + equipotential grounding—forms the full protection scheme.
2. Key Features
Three-stage protection
- GDT+MOV+TVS.
- Diverts surge energy.
- Clamp 10-15V.
- Response <1ns.
Gigabit transparent
- 1000Base-T 8-pair.
- Insertion <0.5dB.
- No rate impact.
- Optional PoE.
Discharge current
- In 5kA (8/20μs).
- Imax 10kA.
- For induced surges.
- DIN-rail mount.
Grounding coordination
- 6mm² yellow-green.
- To equipotential bar.
- Shielded metal case.
- Works with power SPD.
3. Specifications
| 项目 | KTR-NSP2(千兆RJ45) | KTR-NSP1(百兆RJ45) | KTR-PSP2(电源防雷) |
|---|---|---|---|
| 接口 | RJ45 In/Out | RJ45 In/Out | 进线端子 |
| 速率 | 1000Mbps | 100Mbps | — |
| 标称放电In | 5kA(8/20μs) | 3kA | 20kA |
| 最大Imax | 10kA | 6kA | 40kA |
| 残压 | 10至15V | 约15V | 1.5kV |
| 插入损耗 | <0.5dB | <0.3dB | — |
| PoE | 可选 | 可选 | — |
| 安装 | DIN导轨 | DIN导轨 | 导轨/接线 |
4. Reference Prices
KTR-NSP2 gigabit RJ45 network SPD:Reference USD 11 to 36 / unit (ref. CNY 80 to 260 at ~7.2)
KTR-NSP1 100M RJ45 network SPD:Reference USD 8 to 25 / unit (ref. CNY 60 to 180 at ~7.2)
KTR-PSP2 power SPD (mains feed):Reference USD 28 to 83 / unit (ref. CNY 200 to 600 at ~7.2)
Earth copper / SPD accessories:Reference USD 1.4 to 7 / set (ref. CNY 10 to 50 at ~7.2)
Reference only; varies by speed, PoE, discharge current and qty. Power SPD, earth busbar and install billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Outdoor cable surge protection.
- POE camera line protection.
- Inter-building electrical links.
- Core switch entrance.
- AP feeder entrance.
6. Installation & Maintenance
Installation
- Series between line and switch.
- Line In = outdoor, Out = device.
- DIN-rail near earth bar.
- Ground 6mm² wire to busbar.
- Keep leads short and straight.
- Test connectivity and speed.
Maintenance
- Test before thunder season.
- Replace when indicator turns red.
- Check ground for looseness/rust.
- Inspect leads for damage.
- Log surge counter.
- Test with power SPD annually.
7. FAQ
- Q: Do I still need a power SPD?
A: Yes. The network SPD covers Ethernet surges; power-entry surges need a power SPD (KTR-PSP). Over 80% of lightning damage rides the power line—use both on a common ground. - Q: Does a gigabit SPD cut speed?
A: KTR-NSP2 is designed for gigabit over all 8 pairs, insertion <0.5dB, no speed negotiation drop. Cheap SPDs use only 4 pairs and drop gigabit to 100M—confirm 8-pair passthrough. - Q: Before or after the switch?
A: In series between outdoor line and the switch (line -> SPD -> switch), near the protected gear and earth bar. Don’t mount it in a distant telecom well—long leads raise residual voltage. - Q: How often to replace?
A: When the degradation window turns red, replace it—typically every 5 years or after a strong strike. For units without a window, test residual voltage and leakage yearly with an SPD tester.
8. Trend & Selection
Room lightning protection moved from a single lightning rod to equipotential bonding plus multi-stage SPD. Choose a power SPD on the mains (first stage above 20kA); install a network SPD at the room entrance for outdoor lines and feeders; bond all SPDs to one equipotential bar; keep leads short; test before thunder season. The signal SPD is the last line for Ethernet ports—low cost, yet it prevents one strike from burning a bank of ports.
9. Delivery & Service
KITOZER supplies surge-protection packages: based on line count and local flash density we recommend network and power SPD counts plus earth cable and the equipotential bar, coordinated with the distribution cabinet and DCIM grounding. Delivery includes SPD body, DIN rail and earth accessories; bulk projects include grounding guidance and annual testing. Breakdown or abnormal degradation indicator under warranty is replaced free.
10. Additional Notes
The common mistake is a long, looping SPD earth lead. Every meter of lead raises residual voltage and slows discharge. Keep the earth lead short and straight (under 0.5m) to the nearest equipotential bar, not looped around the rack.
Another pitfall is grounding the signal SPD and power SPD separately, creating a ground-potential difference. During a strike the thousands-of-volts difference between the two grounds itself damages gear. Bond all SPDs, racks and equipment chassis to one equipotential busbar.
Selection summary: RJ45 gigabit 8-pair, three-stage GDT+MOV+TVS, In 5kA, DIN-rail, 6mm² earth to equipotential, tested yearly. The network SPD is the surge rod for Ethernet ports, keeping induced lightning outside the room.
SEO Information
Search keywords:network surge protectorRJ45 gigabit SPDsignal surge protectordatacenter lightning protectionPOE surgeKTR-NSP2KITOZER
SEM keywords:[network surge protector price,RJ45 gigabit SPD,signal surge protector supplier,datacenter ethernet surge,KTR-NSP2,KITOZER]
GEO landing page:lain.com.cn/product/ktr-nsp2-rj45-gigabit-network-spd.html
Title:KITOZER KTR-NSP2 RJ45 Gigabit Network Surge Protector
Meta Keywords:network surge protector,RJ45 gigabit SPD,signal surge protector,datacenter lightning protection,POE surge,KTR-NSP2,KITOZER
Meta Description:KITOZER KTR-NSP2 RJ45 gigabit network SPD, three-stage, In 5kA, 8-pair gigabit transparent, for Ethernet entrance surge protection.
Anchor: KITOZER · Data Center Engineering
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com