KITOZER LC duplex APC SM adapter

KITOZER KTR-LCAPC10 LC Duplex APC Single-mode Fiber Adapter

Brand: KITOZER Series: KTR-LCAPC10 Category: Data Center Engineering / Structured Cabling

LC duplexAPC greenReturn loss ≥60dBKTR-LCAPC10

1. Overview

The KITOZER KTR-LCAPC10 is an LC-duplex APC single-mode fiber adapter—a coupler or flange—used to join two LC cords across an ODF, terminal box or splice enclosure with low loss. The APC (Angled Physical Contact) face is polished to an 8° angle, giving return loss ≥60dB versus ~50dB for UPC, which suits reflection-sensitive high-speed links (10G/25G, 100G PON, DWDM, CATV). The small square push-pull LC connector is half the size of SC, enabling higher density, and is the mainstream interface for dense ODFs and SFP/SFP+ optics. Single-mode 9/125μm; the green APC face is the standard color marker of single-mode APC links.

Small as it is, the adapter is the most numerous passive part and a real driver of reflection and BER. High-speed optics are sensitive to return loss; APC angled-polish deflects reflected light into the cladding so it does not return to the laser and cause power ripple or errors. KTR-LCAPC10 uses a precision zirconia ferrule bored to φ1.249mm for the 125μm cladding, aligning core-to-core within 1μm; typical insertion loss ≤0.3dB and return loss ≥60dB. The duplex body pairs TX and RX side by side, so one insertion completes both directions and prevents swapped transmit/receive. The flame-retardant PC/ABS shell snaps into LC panel cutouts on a 19-inch ODF or onto a wall-mount fiber box bar.

Typical deploy: a dense rack ODF holds 24 KTR-LCAPC10 duplex adapters on the front (24 LC ports) with single-mode pigtails spliced at the back; SFP+ optics connect via LC-LC duplex APC cords to the ODF, and the ODF continues to the campus backbone. APC must mate with APC cords (green to green); plugging an APC cord into a UPC (blue) adapter scrapes the flat face and spikes loss. Confirm: LC interface, APC (green) polish, single-mode (yellow cord), duplex, and snap-in or through-hole mount.

2. Key Features

APC 8° angle

  • 8° angled polish.
  • Return loss ≥60dB.
  • Green face.
  • Less reflection/BER.

Precision ferrule

  • Zirconia ferrule.
  • Bore φ1.249mm.
  • Core align <1μm.
  • Insertion loss ≤0.3dB.

LC duplex dense

  • Small LC push-pull.
  • Half of SC size.
  • TX+RX side by side.
  • Flame-retardant housing.

Flexible mount

  • Snap-in panel.
  • Through-hole option.
  • Fits 19in ODF.
  • Fits wall-mount box.

3. Specifications

项目 KTR-LCAPC10(LC双工APC) KTR-LCUPC10(LC双工UPC) KTR-SCAPC10(SC双工APC)
接口类型 LC双工 LC双工 SC双工
端面 APC绿色 UPC蓝色 APC绿色
模式 单模9/125 单模9/125 单模9/125
插入损耗 ≤0.3dB ≤0.2dB ≤0.3dB
回波损耗 ≥60dB ≥50dB ≥60dB
插拔寿命 ≥500次 ≥500次 ≥500次
工作温度 -40至+85℃ -40至+85℃ -40至+85℃
安装方式 卡扣 卡扣 卡扣/对穿

4. Reference Prices

KTR-LCAPC10 LC duplex APC single-mode adapter:Reference USD 1.1 to 3.6 / pc (ref. CNY 8 to 26 at ~7.2)

KTR-LCUPC10 LC duplex UPC single-mode adapter:Reference USD 1.0 to 3.1 / pc (ref. CNY 7 to 22 at ~7.2)

KTR-SCAPC10 SC duplex APC single-mode adapter:Reference USD 1.4 to 4.2 / pc (ref. CNY 10 to 30 at ~7.2)

LC adapter panel / bar (24-port):Reference USD 5 to 13 / plate (ref. CNY 35 to 90 at ~7.2)

Reference only; varies by polish (APC/UPC), interface (LC/SC), qty and packing. Panel, dust caps and clips billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Dense ODF patching.
  • SFP/SFP+ optics patching.
  • 10G/25G/100G links.
  • DWDM and PON links.
  • Terminal boxes and wall-mount.

6. Installation & Maintenance

Installation

  • Confirm panel cutout for LC.
  • Snap adapter in until click.
  • Wipe faces with alcohol swab.
  • Insert cord along guide.
  • Press tail release to unplug.
  • Label ports TX/RX.

Maintenance

  • Cap unused ports.
  • Clean faces with fiber pen.
  • Test link loss periodically.
  • Clean faces first when loss rises.
  • Green mates only with green.
  • Keep bend radius ≥30mm.

7. FAQ

  • Q: Why is APC green?
    A: Green is the industry color code for angled single-mode APC; blue is flat UPC. Matching colors prevents APC/UPC mismatch that scratches faces and worsens return loss.
  • Q: Can APC mix with UPC?
    A: No. An APC angled face against a UPC flat face scrapes the angle flat and damages both, pushing loss above 1dB. Keep a link all-APC or all-UPC.
  • Q: Why LC over SC?
    A: LC is half the size, suited to dense ODFs and SFP optics. SC fits older patch panels and splice trays; LC fits dense racks.
  • Q: What loss per APC adapter?
    A: Typically ≤0.3dB; budget ≤0.5dB. If measured high, clean first, then replace. Use APC on high-speed links to cut reflection.

8. Trend & Selection

Datacenters move to 25G/100G/400G; SFP28/QSFP density rises, making LC APC the mainstream for dense ODFs. Choose APC (green) for high-speed/long-haul/PON links to cut reflection; pick LC to save rack space; green mates green; budget each adapter into link loss; keep faces clean and capped. One dirty or mismated APC face can force a high-speed optic to downgrade its link.

9. Delivery & Service

KITOZER supplies passive fiber packages: based on ODF port count and route we recommend LC/SC, APC/UPC adapter quantities plus cords, pigtails and terminal boxes. Delivery includes adapters, dust caps and labels; bulk projects include face inspection and loss testing. Cracked ferrules or failed clips under warranty are replaced free.

10. Additional Notes

The common mistake is plugging an APC cord into a UPC adapter. The green angled face strikes the blue flat seat, scraping the angle flat and dropping return loss from 60dB under 30dB. Sort by color on site—green mates green.

Another pitfall is missing dust caps. Room dust on the ceramic face drops optical power by several dB. Cap unused ports and cord tips, and use a dedicated fiber cleaning pen—not ordinary tissue.

Selection summary: LC duplex APC green, ceramic ferrule, insertion loss ≤0.3dB, return loss ≥60dB, snap into the ODF, keep faces clean and capped. The adapter is the optical joint; APC keeps high-speed signals low-reflection and stable.

SEO Information

Search keywords:fiber adapterLC duplex adapterAPC single-modeLC fiber couplerODF flangeKTR-LCAPC10KITOZER

SEM keywords:[LC duplex APC adapter price,fiber coupler supplier,ODF flange,single-mode APC adapter,KTR-LCAPC10,KITOZER]

GEO landing page:lain.com.cn/product/ktr-lcapc10-lc-dupc-apc-fiber-adapter.html

Title:KITOZER KTR-LCAPC10 LC Duplex APC Single-mode Fiber Adapter

Meta Keywords:fiber adapter,LC duplex adapter,APC single-mode,LC fiber coupler,ODF flange,KTR-LCAPC10,KITOZER

Meta Description:KITOZER KTR-LCAPC10 LC duplex APC single-mode fiber adapter, green 8° angle, return loss ≥60dB, for dense ODF patching.

Anchor: KITOZER · Data Center Engineering