KITOZER KTR-TH16 RS485 Temperature Humidity Sensor with External Probe

Brand: KITOZER Series: KTR-TH16 Category: Environmental Monitoring / DCIM Sensors

RS485 ModbusExternal probe±0.3℃KTR-TH16

KITOZER KTR-TH16 RS485 Temperature Humidity Sensor with External Probe

1. Overview

The KITOZER KTR-TH16 is a room temperature/humidity sensor using RS485 bus and Modbus RTU, with an external probe, for online monitoring in datacenter rooms, electrical rooms, UPS rooms, archives and clean workshops. The ABS host mounts on DIN rail or wall; the external probe runs through a 2-5m shielded cable to the actual point (cold aisle, rack inlet, above the battery rack), avoiding mismatch between host location and the monitored spot. Temperature ranges -20 to +60℃ at ±0.3℃ accuracy; humidity 0-100%RH at ±2%RH. RS485 daisy-chains up to 32 sensors per bus, and an RS485-to-TCP/IP gateway feeds the DCIM platform for real-time curves and threshold alarms.

Temperature and humidity are the most basic yet critical environment parameters. ASHRAE and Chinese standards set room temperature (18-27℃) and humidity (40-60%RH): too hot and servers throttle/overheat; too cold and condensation forms; too humid and dew shorts equipment; too dry and static damages chips. KTR-TH16’s external probe sits near rack cold/hot aisles, reflecting real inlet temperature better than a wall-mounted host. It supports Modbus RTU (03/04 function codes), address 1-247, baud 9600/19200/38400, compatible with mainstream DCIM hosts, PLC and SCADA. Powered 12-24V DC with surge and reverse-polarity protection.

Typical deploy: a 500㎡ room places 1-2 KTR-TH16 units in the cold aisle, hot aisle, battery room and electrical room; RS485 daisy-chains to a telecom-room DCIM host that uploads via TCP/IP. Probes magnetically or by tie-wrap at rack inlets and beside the battery rack; hosts concentrate on the telecom-room rail. Each sensor gets a unique address bound to a floor-plan point. Select RS485 Modbus (universal), external probe (near the point), temp accuracy ±0.3℃, humidity ±2%RH, 12-24V supply, plus an RS485 gateway and DCIM host.

2. Key Features

RS485 Modbus

  • RS485 daisy-chain.
  • Modbus RTU.
  • Address 1-247.
  • 32 per bus.

External probe

  • Remote probe.
  • Near aisle/inlet.
  • 2-5m shielded cable.
  • Real inlet temp.

High accuracy

  • Temp -20 to +60℃.
  • ±0.3℃ accuracy.
  • Humidity 0-100%RH.
  • ±2%RH accuracy.

Reliable power

  • 12-24V DC.
  • Surge protection.
  • Reverse-polarity.
  • DIN rail/wall.

3. Specifications

项目 KTR-TH16(RS485外置探头) KTR-TH16I(RS485内置探头) KTR-TH16E(以太网型)
输出 RS485 Modbus RS485 Modbus TCP/IP以太网
探头 外置2至5m 内置 外置2至5m
温度范围 -20至+60℃ -20至+60℃ -20至+60℃
温度精度 ±0.3℃ ±0.3℃ ±0.3℃
湿度精度 ±2%RH ±2%RH ±2%RH
供电 12至24V DC 12至24V DC PoE/12V DC
安装 导轨/壁挂 导轨/壁挂 导轨/壁挂
组网 手拉手32只 手拉手32只 以太网直接

4. Reference Prices

KTR-TH16 RS485 temp/humidity sensor (external probe):Reference USD 25 to 63 / unit (ref. CNY 180 to 450 at ~7.2)

KTR-TH16I RS485 temp/humidity sensor (built-in probe):Reference USD 21 to 53 / unit (ref. CNY 150 to 380 at ~7.2)

KTR-TH16E Ethernet temp/humidity sensor:Reference USD 42 to 90 / unit (ref. CNY 300 to 650 at ~7.2)

RS485 gateway / shielded cable / power:Reference USD 11 to 69 / set (ref. CNY 80 to 500 at ~7.2)

Reference only; varies by output (RS485/Ethernet), probe type, qty and paired gateway/DCIM host. Cabling and platform software billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room cold/hot aisle.
  • Electrical/UPS rooms.
  • Battery room.
  • Archives/clean rooms.
  • DCIM environment points.

6. Installation & Maintenance

Installation

  • DIN-rail/wall host.
  • Route/fix probe at point.
  • RS485 daisy-chain.
  • Set unique address/baud.
  • Connect gateway/DCIM.
  • Bind/calibrate in platform.

Maintenance

  • Calibrate yearly.
  • Keep probe off direct vent.
  • Check RS485 terminals.
  • Measure supply voltage.
  • Keep probe clean.
  • Log curves.

7. FAQ

  • Q: How to wire RS485 daisy-chain?
    A: A to A, B to B, daisy-series—not star branches. Add a 120Ω terminator at both bus ends, route away from interference, and ground the shield at one end.
  • Q: Where is the probe most accurate?
    A: At the rack cold-aisle inlet or hot-aisle return—not directly under a supply vent (that measures supply air, not return), and not in a wall corner. Place it near the monitored gear.
  • Q: What alarm thresholds?
    A: Typically temp high 27℃, low 18℃; humidity high 60%RH, low 40%RH. Tune by room class and gear, with buffer to avoid false alarms.
  • Q: What if addresses conflict?
    A: Two sensors at the same address fight on the bus and corrupt readings. Set a unique address (1-247) per unit and keep an address-to-point table.

8. Trend & Selection

Environment monitoring shifts from manual patrol to full online sensing; the temp/humidity sensor is the basic sensing layer. RS485 Modbus is universal and low-cost; critical rooms use external probes near inlets; link thresholds to cooling and alarms; keep addresses unique; upload via gateway to DCIM. Accurate temperature/humidity is the basis for PUE and cooling optimization.

9. Delivery & Service

KITOZER supplies environment-monitoring packages: based on the room point map we recommend sensor counts, probe locations plus RS485 gateways and DCIM hosts, integrated with leak, access and video into DCIM. Delivery includes host, probe, terminals and manual; bulk projects include networking, commissioning and calibration. Out-of-spec drift or communication faults under warranty are replaced free.

10. Additional Notes

The common mistake is star-wiring RS485. Star branches reflect signals and destabilize comms. Use a daisy-chain with terminators at both ends.

Another pitfall is placing the probe right under an AC supply vent, reading cold supply air instead of rack return. The probe must reflect real inlet/outlet—place it in the aisles, away from direct blow.

Selection summary: RS485 Modbus, external probe, temp ±0.3℃ / humidity ±2%RH, 12-24V supply, unique address, gateway to DCIM. The KTR-TH16 is the room’s thermometer—accurate readings keep the room stable.

SEO Information

Search keywords:temperature humidity sensorRS485 temp humidityroom environment monitoringModbus humidity sensorexternal probeKTR-TH16KITOZER

SEM keywords:[RS485 temp humidity sensor price,room environment monitoring,Modbus humidity sensor supplier,external probe sensor,KTR-TH16,KITOZER]

GEO landing page:lain.com.cn/product/ktr-th16-rs485-temperature-humidity-sensor-external-probe.html

Title:KITOZER KTR-TH16 RS485 Temperature Humidity Sensor with External Probe

Meta Keywords:temperature humidity sensor,RS485 temp humidity,room environment monitoring,Modbus humidity sensor,external probe,KTR-TH16,KITOZER

Meta Description:KITOZER KTR-TH16 RS485 Modbus temp/humidity sensor with external probe, ±0.3℃ / ±2%RH, for room environment monitoring.

Anchor: KITOZER · Environmental Monitoring

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart