KITOZER KTR-FB24LC Rack 24-port LC UPC Fiber Patch Box

Brand: KITOZER Series: KTR-FB24LC Category: Data Center Engineering / Structured Cabling

24-port LC UPC1U rackSplice trayKTR-FB24LC

KITOZER KTR-FB24LC Rack 24-port LC UPC Fiber Patch Box

1. Overview

The KITOZER KTR-FB24LC is a 19-inch rack 24-port LC UPC fiber patch box (also called ODF or fiber enclosure) used inside a rack to aggregate and terminate fiber cables, linking backbone cables to equipment jump cords. The 1U cold-rolled steel box is black-coated; the front panel holds 24 LC duplex adapters (48 fibers total), UPC blue face, single-mode or multimode options. Inside are splice trays and pigtail storage: backbone cable enters from the rear, splices to pigtails, and exits through the adapters. Rack-mount on 19-inch posts with front/rear cable entry, suited to rack fiber aggregation and server access in datacenters.

Vs wall-mount enclosures, the rack KTR-FB24LC concentrates termination at a rack U-space alongside switches and servers, shortening jump cords and tidying cabling. 24 LC duplex ports terminate 48 fibers (one 48-core backbone or two 24-core); internal trays hold 12-core splices with slack coiled at radius ≥30mm to avoid micro-bend loss. The blue UPC flat face gives return loss ≥50dB for standard-rate single-mode (1G/10G) and multimode use; choose green APC for reflection-sensitive high-speed links. Adapters survive ≥500 insertions; the panel has label fields for port numbering.

Typical deploy: a datacenter rack brings in one 48-core single-mode backbone to the rear of a KTR-FB24LC; the cable is stripped and its strength member anchored to the box ground post, fibers spliced in 12-core trays, pigtails terminated to 24 LC duplex adapters; the front uses LC-LC cords to switch SFP+ optics. Keep 1-2 spare adapters. Select by port count (12/24/48), interface (LC/SC), polish (UPC/APC), mode (SM/OM3) and U-height (1U/2U).

2. Key Features

24-port LC duplex

  • 24 LC duplex adapters.
  • 48 fibers.
  • 1U rack.
  • Front/rear entry.

UPC blue face

  • Blue flat polish.
  • Return loss ≥50dB.
  • 1G/10G use.
  • SM/MM option.

Built-in splice tray

  • 12-core tray.
  • Pigtail storage.
  • Slack coil ≥30mm.
  • Strength ground.

Steel coated

  • 1U steel plate.
  • Black coating.
  • Label field.
  • ≥500 insertions.

3. Specifications

项目 KTR-FB24LC(24口LC UPC 1U) KTR-FB48LC(48口LC 2U) KTR-FB24SC(24口SC UPC 1U)
端口数 24只LC双工 48只LC双工 24只SC双工
端接芯数 48芯 96芯 48芯
U位高度 1U 2U 1U
端面 UPC蓝色 UPC/APC可选 UPC蓝色
熔接盘 12芯/盘×2 12芯/盘×4 12芯/盘×2
进线方式 前后侧 前后侧 前后侧
插入损耗 ≤0.3dB ≤0.3dB ≤0.3dB
安装 19英寸机架 19英寸机架 19英寸机架

4. Reference Prices

KTR-FB24LC 1U 24-port LC UPC rack fiber patch box:Reference USD 25 to 63 / unit (ref. CNY 180 to 450 at ~7.2)

KTR-FB48LC 2U 48-port LC rack fiber patch box:Reference USD 44 to 104 / unit (ref. CNY 320 to 750 at ~7.2)

KTR-FB24SC 1U 24-port SC UPC rack fiber patch box:Reference USD 22 to 53 / unit (ref. CNY 160 to 380 at ~7.2)

Pigtails / splice sleeves / labels:Reference USD 3 to 21 / set (ref. CNY 20 to 150 at ~7.2)

Reference only; varies by port count, interface, polish (UPC/APC), mode (SM/OM3) and qty. Pigtails, splice sleeves and labels billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Backbone cable termination.
  • Server/switch patching.
  • Datacenter ODF aggregation.
  • SM/MM link distribution.
  • High-density fiber patching.

6. Installation & Maintenance

Installation

  • Mount 1U to rack posts.
  • Backbone enters rear.
  • Anchor strength to ground.
  • Splice fibers in trays.
  • Terminate pigtails to adapters.
  • Label front ports.

Maintenance

  • Cap unused ports.
  • Clean adapter faces.
  • Keep bend radius ≥30mm.
  • Match labels to ports.
  • Do not disturb slack coils.
  • Keep spare ports.

7. FAQ

  • Q: 24 or 48 ports?
    A: By cable cores and headroom. One 24-core backbone uses 24-port; two 24-core or one 48-core use 48-port. Keep 30% spare ports.
  • Q: UPC or APC?
    A: Standard 1G/10G single-mode use blue UPC for value; high-speed 25G/100G, PON and DWDM use green APC to cut reflection. Do not mix in one link.
  • Q: Splice or quick-connect?
    A: Backbone into the box uses splicing (low loss, reliable); jump cords use quick-connect. Trays hold slack for re-splicing.
  • Q: Can I expand after full?
    A: A 24-port box holds 24 LC duplex—full means no expansion. Upgrade to 48-port or add another box; plan U-space headroom.

8. Trend & Selection

Datacenters move to high-density fiber patching; LC and 1U boxes dominate. Choose port count by cable cores plus headroom; APC green for high-speed links; yellow cords for SM, aqua for OM3; coil slack at ≥30mm; keep labels aligned with docs; cap unused ports. A poorly planned patch box forces re-splicing later at high cost.

9. Delivery & Service

KITOZER supplies fiber termination packages: based on backbone cores and rack U-space we recommend 12/24/48-port LC/SC patch boxes plus pigtails, splice sleeves and labels. Delivery includes box, adapters, trays and manual; bulk projects include splice guidance and loss testing. Cracked housings or failed adapters under warranty are replaced free.

10. Additional Notes

The common mistake is over-tightening slack coils. Tight bends under 30mm radius add micro-bend loss and drop optical power. Coil slack loosely with radius ≥30mm and secure with loop ties.

Another pitfall is mixing UPC blue and APC green in one link. APC angled against UPC flat scrapes faces and spikes loss. Keep a link all-UPC or all-APC and sort adapters by color.

Selection summary: 1U rack, 24 LC duplex UPC, 48-fiber termination, built-in splice tray, front/rear entry, port labels. The KTR-FB24LC is the rack’s fiber patch point—plan it well and expansion stays cheap.

SEO Information

Search keywords:fiber patch box24-port LC boxrack ODFLC UPC enclosurefiber termination boxKTR-FB24LCKITOZER

SEM keywords:[24-port LC patch box price,rack ODF supplier,LC UPC enclosure,fiber termination box,KTR-FB24LC,KITOZER]

GEO landing page:lain.com.cn/product/ktr-fb24lc-rack-24port-lc-upc-fiber-patch-box.html

Title:KITOZER KTR-FB24LC Rack 24-port LC UPC Fiber Patch Box

Meta Keywords:fiber patch box,24-port LC box,rack ODF,LC UPC enclosure,fiber termination box,KTR-FB24LC,KITOZER

Meta Description:KITOZER KTR-FB24LC 1U rack 24-port LC UPC fiber patch box with splice tray, 48-fiber termination, for rack fiber aggregation.

Anchor: KITOZER · Data Center Engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart