KITOZER LC duplex UPC OM4 adapter

KITOZER KTR-LUPC11 Fiber Optic Adapter / LC Duplex UPC OM4

Brand: KITOZER Series: KTR-LUPC11 Category: Data Center Engineering / Fiber Adapter

LC DuplexUPCOM4≤0.2dB

KITOZER KTR-LUPC11 Fiber Optic Adapter / LC Duplex UPC OM4

1. Overview

The KITOZER KTR-LUPC11 is an LC duplex UPC fiber optic adapter (also called LC-LC coupler or flange), used to mate two LC fiber connectors on patch panels, ODF boxes and equipment panels. LC connectors use a 1.25mm ferrule—half the size of SC—and are widely used in high-density racks. UPC (Ultra Physical Contact) end-face polish gives a spherical profile with return loss better than 50 dB and insertion loss below 0.2 dB. OM4 multimode fiber supports 100 Gbps SR4 transmission at 850 nm, ideal for short-reach high-speed links between data-center switches, server NICs and storage networks.

The KTR-LUPC11 uses a plastic housing with a ceramic ferrule sleeve. The duplex design holds two LC ports side by side, mating send and receive of one patch cord simultaneously to avoid mis-pairing. Both front and rear ports are LC type: one side connects to the equipment cord, the other to the backbone cable. The ceramic sleeve bore is ±0.5 μm precision, aligning the two LC ferrules to minimize eccentricity loss. Compared with two separate simplex adapters, the duplex keeps send/receive paired for cleaner labeling and routing; compared with APC (green), UPC (blue) is for multimode data centers while APC is mainly for single-mode PON. The panel cutout fits standard 19-inch rack patch panels.

Typical deploy: a 42U cabinet uses a 1U fiber patch panel with 24 KTR-LUPC11 duplex adapters (48 fibers OM4). Equipment-side LC-LC OM4 cords connect to switch SFP28 ports; the panel-side backbone runs to the telecom-room ODF. Each adapter corresponds to one fiber pair (Tx/Rx); color-coded labels mark backbone routes. Select by connector type (LC), end-face (UPC/APC), mode (OM3/OM4/OS2) and mounting (panel/coupler). OM4 has higher bandwidth (4700 MHz·km vs OM3’s 2000) and is the default for short-reach 10G/100G.

2. Key Features

LC duplex UPC

  • 1.25mm ceramic ferrule.
  • Duplex send/receive.
  • UPC spherical polish.
  • Blue housing.

Low loss

  • Insertion ≤0.2dB.
  • Return ≥50dB.
  • Ceramic sleeve alignment.
  • >1000 mating cycles.

OM4 multimode

  • 850nm wavelength.
  • 100G SR4 ready.
  • 4700 MHz·km.
  • Short-reach high speed.

High density

  • Panel snap-in.
  • 19-inch rack fit.
  • Side-by-side duplex.
  • Clear labeling.

3. Specifications

Item KTR-LUPC11 (LC duplex UPC OM4) KTR-LAPC11 (LC duplex APC OM4) KTR-SUPC11 (SC duplex UPC OM4)
Connector LC duplex LC duplex SC duplex
Polish UPC (blue) APC (green) UPC (blue)
Fiber mode OM4 MMF OM4 MMF OM4 MMF
Insertion loss ≤0.2dB ≤0.3dB ≤0.2dB
Return loss ≥50dB ≥60dB ≥50dB
Ferrule Ceramic 1.25mm Ceramic 1.25mm Ceramic 2.5mm
Cycles >1000 >1000 >1000
Mounting Panel snap-in Panel snap-in Panel snap-in

4. Reference Prices

KTR-LUPC11 LC duplex UPC OM4 adapter: Reference USD 2 to 5 / pc (ref. CNY 15 to 35 at ~7.2)

KTR-LAPC11 LC duplex APC OM4 adapter: Reference USD 3 to 6 / pc (ref. CNY 20 to 45 at ~7.2)

KTR-SUPC11 SC duplex UPC OM4 adapter: Reference USD 2 to 4 / pc (ref. CNY 12 to 30 at ~7.2)

Panel / dust caps / labels: Reference USD 1 to 3 / set (ref. CNY 5 to 25 at ~7.2)

Reference only; varies by connector, polish, mode and qty. Volume pricing available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data-center switch ports.
  • Server NIC fiber links.
  • SAN cabling.
  • Telecom-room ODF termination.
  • High-density rack patching.

6. Installation & Maintenance

Installation

  • Panel cutout.
  • Snap adapter into panel.
  • Insert LC cords both sides.
  • Verify blue UPC.
  • Label routes.
  • Test with power meter.

Maintenance

  • Clean end faces regularly.
  • Dust caps on unused ports.
  • Check mating force.
  • Inspect ceramic sleeve.
  • Bend radius ≥30mm.
  • Replace damaged adapters.

7. FAQ

  • Q: UPC or APC?
    A: Multimode data centers use UPC (blue) for 850nm short-reach; single-mode PON/broadcast uses APC (green) with higher return loss (≥60dB). LC duplex OM4 defaults to UPC.
  • Q: OM4 vs OM3?
    A: OM4 bandwidth 4700 MHz·km vs OM3 2000. 100G SR4 requires OM4; 10G SR works on both, but OM4 gives more headroom. New cabling should use OM4.
  • Q: High insertion loss?
    A: Clean end face (alcohol swab) and ceramic sleeve; check ferrule cracks; confirm both sides are UPC; avoid tight bend radius.
  • Q: Duplex vs two simplex?
    A: Duplex is one housing with two LC ports—send/receive together, neat. Simplex are separate and easy to cross-pair. High-density panels use duplex.

8. Trend & Selection

Data centers evolve toward 400G/800G; OM4/OM5 multimode and LC/MTP connectors are mainstream. Use OM4 for new cabling; choose LC duplex UPC for high-density panels; use standard 19-inch panels; label every port; keep 10% spare ports; use dust caps. Adapter loss is small per port but accumulates to several dB across hundreds of ports—low-loss adapters are worth the investment.

9. Delivery & Service

KITOZER supplies fiber adapter packages: based on panel port count and connector type, we recommend LC/SC duplex UPC/APC adapter quantities, plus dust caps, labels and cleaning pens, delivered with patch panels and cords. Bulk projects include sample loss test reports. Ceramic cracks or abnormal mating force under warranty are replaced free.

10. Additional Notes

The common mistake is mixing UPC and APC. UPC (blue) and APC (green) have different end-face angles (APC is 8° angled); mixing scratches ferrules and spikes loss. Check color: blue = UPC, green = APC—never cross.

Another pitfall is leaving dust caps off. Exposed ceramic sleeves collect dust; every insertion grinds the ferrule face, increasing loss year by year. Unused ports must have caps, and connector plugs too.

Selection summary: LC duplex UPC OM4; insertion ≤0.2dB; return ≥50dB; ceramic 1.25mm ferrule; panel snap-in; >1000 cycles. The KTR-LUPC11 is the gateway of high-density fiber links—every mating, clean and precise.

SEO Information

Search keywords:fiber optic adapterLC duplex adapterUPC couplerOM4 fiber adapterLC-LC duplex flangeKTR-LUPC11KITOZER

SEM keywords:[fiber optic adapter,LC duplex adapter,UPC coupler,OM4 fiber adapter,LC-LC duplex flange,KTR-LUPC11,KITOZER]

GEO landing page:lain.com.cn/product/ktr-lupc11-lc-duplex-upc-om4-fiber-adapter.html

Title:KITOZER KTR-LUPC11 Fiber Optic Adapter / LC Duplex UPC OM4

Meta Keywords:fiber optic adapter,LC duplex adapter,UPC coupler,OM4 fiber adapter,LC-LC duplex flange,KTR-LUPC11,KITOZER

Meta Description:KITOZER KTR-LUPC11 LC duplex UPC fiber adapter, OM4 multimode compatible, insertion loss ≤0.2dB, for patch panel and equipment panel coupling.

Anchor: KITOZER · Data Center Engineering