KITOZER
KITOZER

KITOZER 3 phase 380V 80kA B SPD

KITOZER KTR-PS6 Power Surge Protector / 3-Phase 380V 80kA Class B

Brand: KITOZER Series: KTR-PS6 Category: Power Distribution / Surge Protection

3-Phase 380V80kA Class BDIN-railRemote alarm

1. Overview

The KITOZER KTR-PS6 is a three-phase power surge protective device (SPD) for room main distribution cabinet surge protection. Rated system voltage 380V AC (three-phase five-wire L1/L2/L3/N/PE), nominal discharge current In 80kA (8/20μs), maximum discharge Imax 150kA—Class B (Type I test). Lightning induction or switching surges on the power line are clamped by the SPD’s metal-oxide varistor (MOV) to a safe level in nanoseconds, diverting surge current to ground and protecting downstream UPS, CRAC and servers.

The KTR-PS6 uses a DIN-rail modular design: four modules (L1/L2/L3/N) plug into a base; PE connects directly to the cabinet ground bar. Each phase module has a status window (green normal / red failed) and a remote-signaling dry contact that alarms when the module degrades. Class B SPD installs after the main breaker in the mains intake cabinet; Class C (end distribution, 40kA) provides two-stage protection—Class B handles large direct-lightning-induced energy, Class C fine-clamps equipment-side voltage. Compared with a single Class C stage, two-stage protection gives lower residual voltage at the equipment and passes 8/20μs and 10/350μs tests; compared with standalone MOVs, modular SPDs allow live replacement of degraded modules without power interruption. Response time <25ns, voltage protection level Up≤2.5kV.

Typical deploy: an 800kVA room installs KTR-PS6-3+N (three-phase plus neutral, Class B, 80kA) on the mains intake cabinet DIN rail below the main breaker. End distribution boxes between the cabinet and row PDUs add Class C SPDs (20-40kA). The SPD ground wire is at least 16mm², connected directly to the room equipotential ground bar (ground resistance ≤1Ω). Remote contacts wire to the DCIM platform for module-failure popup alarms. Select by system voltage (220V single / 380V three-phase), lightning protection zone (LPZ0 Class B / LPZ1 Class C) and discharge current (80kA/40kA/20kA); choose standard or remote-signaling version as needed.

2. Key Features

3-phase 380V Class B

  • 3-phase 5-wire.
  • In 80kA (8/20μs).
  • Imax 150kA.
  • Up≤2.5kV.

Modular DIN rail

  • L1/L2/L3/N modules.
  • DIN-rail mount.
  • Live module swap.
  • Status window.

Remote alarm

  • Dry contact.
  • Degradation alarm.
  • To DCIM.
  • Green/red indicator.

Two-stage coordination

  • Class B intake.
  • Class C row PDU.
  • Decoupling coordination.
  • Response <25ns.

3. Specifications

Item KTR-PS6-3+N (3-ph 80kA) KTR-PS6-1+N (1-ph 40kA) KTR-PS6-3+N-C (3-ph 40kA Class C)
System voltage 380V AC 3-phase 220V AC 1-phase 380V AC 3-phase
Nominal In 80kA (8/20μs) 40kA (8/20μs) 40kA (8/20μs)
Max Imax 150kA 80kA 80kA
Protection Up ≤2.5kV ≤1.8kV ≤1.8kV
Response <25ns <25ns <25ns
Mounting DIN 4P DIN 2P DIN 4P
Remote contact Optional Optional Optional
Class Class B (Type I) Class C (Type II) Class C (Type II)

4. Reference Prices

KTR-PS6-3+N 3-phase 80kA Class B SPD: Reference USD 111 to 208 / set (ref. CNY 800 to 1500 at ~7.2)

KTR-PS6-1+N 1-phase 40kA SPD: Reference USD 35 to 69 / set (ref. CNY 250 to 500 at ~7.2)

KTR-PS6-3+N-C 3-phase 40kA Class C: Reference USD 69 to 125 / set (ref. CNY 500 to 900 at ~7.2)

Remote module / ground bar / wires: Reference USD 7 to 42 / set (ref. CNY 50 to 300 at ~7.2)

Reference only; varies by voltage, discharge current, class and qty. Remote contacts and ground bars billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room mains intake cabinet.
  • Row PDU end distribution.
  • UPS front-end surge suppression.
  • Outdoor equipment power.
  • Two-stage distribution protection.

6. Installation & Maintenance

Installation

  • Power off main breaker.
  • Mount SPD base on DIN rail.
  • Wire L1/L2/L3/N.
  • PE to ground bar.
  • Remote wire to DCIM.
  • Power on, confirm green.

Maintenance

  • Check window monthly.
  • Inspect after thunderstorms.
  • Replace on red.
  • Tight ground wire.
  • Test remote contact.
  • Full replacement 3-5 years.

7. FAQ

  • Q: Class B vs C?
    A: Class B (≥80kA) goes in the intake cabinet to discharge large direct-lightning-induced energy; Class C (20-40kA) goes in row PDUs or end boxes to fine-clamp equipment-side voltage. Rooms need both stages.
  • Q: Window turned red—still usable?
    A: Red means the MOV has degraded; protection is diminished. Replace the module soon, or the next surge may bypass the SPD and hit equipment directly.
  • Q: How thick is the SPD ground wire?
    A: Class B at least 16mm² stranded copper; Class C at least 10mm². Keep it short—under 0.5m—directly to the equipotential ground bar.
  • Q: Must I disconnect SPD during thunderstorms?
    A: No. The SPD is designed to work during storms. It sits parallel, high-impedance under normal voltage and low-impedance during surges. Just check the window afterward.

8. Trend & Selection

Room distribution surge protection moves from ‘single Class C’ to ‘B+C two-stage with remote online monitoring’. Use Class B 80kA three-phase at the intake; Class C 40kA at row PDUs; wire remote contacts to DCIM; keep ground wires under 0.5m directly to the equipotential bar; replace degraded modules. A single lightning surge can destroy an entire row of UPS and servers—SPD cost is under 2% of distribution budget but protection value is enormous.

9. Delivery & Service

KITOZER supplies power surge packages: based on the room distribution diagram and lightning protection zone layout, we recommend Class B/C SPD models and locations, plus ground bars, wires and remote-signaling modules, integrated with the DCIM platform. Bulk projects include two-stage coordination calculations. Self-failure (non-surge) under warranty is replaced free.

10. Additional Notes

The common mistake is wiring the SPD ground to the neutral bar instead of the ground bar. PE must go directly to the room equipotential ground bar; wiring to neutral introduces surge current into the neutral line and endangers equipment.

Another pitfall is no decoupling between B and C stages. When B and C SPDs are within 10m, add decoupling inductors or conductors, or the C stage trips first and the B stage becomes ineffective. Check the manufacturer’s decoupling-distance table.

Selection summary: 3-phase 380V; Class B 80kA In; modular DIN rail; remote alarm; Up≤2.5kV; response <25ns. The KTR-PS6 is the room power's lightning rod—keeping surges outside the equipment door.

SEO Information

Search keywords:room surge protector3-phase SPD380V surge protector80kA Class B SPDpower surge protective deviceKTR-PS6KITOZER

SEM keywords:[room surge protector,3-phase SPD,380V surge protector,80kA Class B SPD,power surge protective device,KTR-PS6,KITOZER]

GEO landing page:lain.com.cn/product/ktr-ps6-3phase-380v-80ka-class-b-spd.html

Title:KITOZER KTR-PS6 Power Surge Protector / 3-Phase 380V 80kA Class B

Meta Keywords:room surge protector,3-phase SPD,380V surge protector,80kA Class B SPD,power surge protective device,KTR-PS6,KITOZER

Meta Description:KITOZER KTR-PS6 three-phase power surge protective device, 380V system, nominal discharge current 80kA (Class B), DIN-rail mount, for room main distribution cabinet surge protection.

Anchor: KITOZER · Power Distribution