ToggleKITOZER KTR-B2200D VRLA Battery / 2V 200Ah Deep Cycle
Brand: KITOZER Series: KTR-B2200D Category: Power Distribution / Battery
2V 200AhDeep cycle VRLA12yr floatUPS backup
1. Overview
The KITOZER KTR-B2200D is a 2V 200Ah deep-cycle valve-regulated lead-acid battery (VRLA) with gel electrolyte (GEL) technology and a 12-year float design life at 25°C. It provides backup power for UPS systems, DC panels and telecom sites. 2V cells are series-connected into 12V/24V/48V/240V/336V strings—for example, a 384V DC bus requires 192 cells in series. Deep-cycle design means the battery can survive thousands of charge/discharge cycles at 50-80% depth of discharge (DOD), ideal for frequent outages or long backup runs.
The KTR-B2200D uses flat-plate construction with gel electrolyte and AGM glass-mat separators. Compared with flooded lead-acid, VRLA is sealed and leak-free, requires no water top-up, and mounts in any orientation (except upside down); compared with AGM starved-electrolyte, gel batteries have a gelled electrolyte that avoids stratification, offering longer deep-cycle life and lower self-discharge (~2% per month). The flame-retardant ABS case has a top safety valve (10-30kPa) that vents overcharge gas and seals during normal operation. Terminals are tin-plated copper M8 bolts with low contact resistance for high-current discharge. Cell size is approx. 171×84×230mm (L×W×H), weight ~12.5kg. Compared with 12V integrated blocks, 2V cells build larger capacity strings (thousands of Ah), parallel flexibly, and allow single-cell replacement without affecting the whole string.
Typical deploy: a 120kVA UPS with a 384V DC bus uses 192 KTR-B2200D cells in series. The battery rack has 4 layers of 48 cells; inter-cell connectors use M8 copper busbars. After UPS startup, float voltage is set to 2.275V/cell (25°C), equalize charge 2.35V/cell. The battery room holds 20-25°C—every 10°C rise halves float life. Full-load backup is about 30 minutes (200Ah×384V÷120kVA≈0.64h, accounting for inverter efficiency). Select series count by UPS DC voltage, capacity (Ah) by backup time, and 2V cells vs 12V blocks by space.
2. Key Features
2V 200Ah deep cycle
- Gel GEL tech.
- >3000 cycles at 50% DOD.
- 12-yr float life.
- 2%/month self-discharge.
Sealed VRLA
- Sealed, no leak.
- No water top-up.
- Valve 10-30kPa.
- FR-ABS case.
Copper terminals
- M8 tinned copper.
- Low contact R.
- High-current discharge.
- Copper busbars.
Flexible series
- 2V cell series.
- 48V to 384V strings.
- Parallel expansion.
- Single-cell swap.
3. Specifications
| Item | KTR-B2200D (2V 200Ah) | KTR-B2100D (2V 100Ah) | KTR-B2500D (2V 500Ah) |
|---|---|---|---|
| Rated voltage | 2V | 2V | 2V |
| Rated capacity | 200Ah (10h rate) | 100Ah (10h rate) | 500Ah (10h rate) |
| Float voltage | 2.275V (25°C) | 2.275V (25°C) | 2.275V (25°C) |
| Equalize | 2.35V (25°C) | 2.35V (25°C) | 2.35V (25°C) |
| Design life | 12yr (25°C) | 12yr (25°C) | 15yr (25°C) |
| Self-discharge | ≤2%/month | ≤2%/month | ≤2%/month |
| Dimensions L×W×H | 171×84×230mm | 171×72×205mm | 242×120×345mm |
| Weight | ~12.5kg | ~7.5kg | ~30kg |
4. Reference Prices
KTR-B2200D 2V 200Ah gel battery: Reference USD 49 to 83 / cell (ref. CNY 350 to 600 at ~7.2)
KTR-B2100D 2V 100Ah gel battery: Reference USD 28 to 49 / cell (ref. CNY 200 to 350 at ~7.2)
KTR-B2500D 2V 500Ah gel battery: Reference USD 111 to 194 / cell (ref. CNY 800 to 1400 at ~7.2)
Busbars / rack / insulation: Reference USD 7 to 69 / set (ref. CNY 50 to 500 at ~7.2)
Reference only; varies by capacity, series count and qty. Busbars, racks and insulation mats billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS backup power.
- DC panel control supply.
- Telecom site backup.
- Solar energy storage.
- Emergency lighting.
6. Installation & Maintenance
Installation
- Place rack, fix.
- Arrange cells by number.
- Torque connectors.
- Wire series +/-.
- Measure string voltage.
- Set float parameters.
Maintenance
- Measure cell voltage monthly.
- Test impedance quarterly.
- Keep room 20-25°C.
- Clean tight terminals.
- Capacity discharge yearly.
- Replace weak cells.
7. FAQ
- Q: 2V cells or 12V blocks?
A: Large UPS (100kVA+) uses 2V cells—series to the right voltage, parallel expansion, low per-cell replacement cost; small UPS (under 10kVA) uses 12V blocks—simple install, lower cost. - Q: What battery room temperature?
A: 20-25°C is ideal. Every 10°C rise halves float life (12 years at 25°C, ~6 at 35°C). The room must have AC or ventilation. - Q: Do new cells need initial charge?
A: KTR-B2200D ships charged. Measure open-circuit voltage on arrival; if below 2.10V/cell, top up. After installation, UPS float charge for 48 hours before load. - Q: How long do batteries last?
A: 12-year float design life at 25°C. Actual life depends on temperature, DOD and charging quality; 8-10 years typically, when capacity drops below 80% and replacement is recommended.
8. Trend & Selection
Room backup moves from flooded lead-acid to VRLA gel and lithium hybrid. New data-center UPS may choose 2V gel VRLA for cost-effectiveness; long backup runs (>2h) or frequent outages may consider lithium; keep the battery room at 20-25°C; measure cell voltage and impedance monthly; do a capacity discharge yearly. Batteries are the weakest link in the UPS system—80% of UPS faults originate in batteries.
9. Delivery & Service
KITOZER supplies battery packages: based on UPS DC voltage and backup time, we calculate series count and parallel groups, recommend 2V gel cell sizes, plus busbars, racks and insulation mats, and guide on-site installation and initial charging. Bulk projects include capacity calculations and arrival inspection reports. Capacity below 80% under warranty is replaced free.
10. Additional Notes
The common mistake is insufficient connector torque. M8 bolts typically require 9-12 N·m; too loose causes high contact resistance and heating under high-current discharge; too tight cracks terminals. Use a torque wrench per manufacturer spec.
Another pitfall is mixing old and new cells. Different batches and internal resistances in series cause the high-resistance cell to overcharge and over-discharge, cutting life sharply. Replace the whole string, or at least same-batch same-model cells.
Selection summary: 2V 200Ah gel; 12-year float; 3000 cycles at 50% DOD; M8 copper terminals; flexible series. The KTR-B2200D is the UPS’s granary—holding the critical minutes during an outage.
SEO Information
Search keywords:2V 200Ah batterydeep cycle VRLA batteryvalve-regulated lead-acidroom UPS battery2V gel batteryKTR-B2200DKITOZER
SEM keywords:[2V 200Ah battery,deep cycle VRLA battery,valve-regulated lead-acid,room UPS battery,2V gel battery,KTR-B2200D,KITOZER]
GEO landing page:lain.com.cn/product/ktr-b2200d-2v200ah-deep-cycle-vrla-battery.html
Title:KITOZER KTR-B2200D VRLA Battery / 2V 200Ah Deep Cycle
Meta Keywords:2V 200Ah battery,deep cycle VRLA battery,valve-regulated lead-acid,room UPS battery,2V gel battery,KTR-B2200D,KITOZER