ToggleKITOZER KTR-LCAPC12 LC Duplex APC OM3 Fiber Adapter
Brand: KITOZER Series: KTR-LCAPC12 Category: Data Center Engineering / Fiber Adapter
LC duplexAPC greenOM3 multimodeInsertion <0.3dB

1. Overview
[‘The KITOZER KTR-LCAPC12 is an LC duplex APC fiber adapter (LC-LC coupler / flange) with a green housing marking APC polish, used to mate two LC connectors on patch panels, ODF boxes and equipment panels. The LC connector uses a 1.25 mm ferrule, half the size of SC, and dominates high-density data-center racks. APC (Angled Physical Contact) is polished at an 8-degree angle for return loss above 60 dB, suiting reflection-sensitive high-speed links better than UPC. OM3 multimode supports 10 GbE to 300 m and 40G/100G SR4 short-reach links between switches, server NICs and storage.’, ‘The KTR-LCAPC12 uses flame-retardant engineering-plastic housing with a precision ceramic sleeve. The duplex design fixes two LC ports side by side in one body so transmit and receive of one jumper mate together, cutting mis-plugs. Both sides are LC: equipment-side jumper on one end, backbone fiber on the other. The ceramic sleeve bore is ±0.5 μm to align the two ferrules and reduce eccentricity loss. Compared with separate simplex adapters, the duplex keeps Tx/Rx paired for neat labeling; compared with blue UPC, the green APC angled polish gives lower back-reflection in PON, CATV and high-speed links. Panel cutouts meet 19-inch rack standards.’, ‘Typical deploy: in a 42U rack, switch-to-server jumpers terminate on a 1U patch panel holding 24 KTR-LCAPC12 duplex adapters (48-fiber OM3). Equipment-side LC-LC OM3 jumpers run to switch SFP+ ports; backbone fiber runs to the telecom-room ODF. Each adapter maps to one fiber pair, labeled by route. Select by connector (LC), polish (APC green / UPC blue), mode (OM3/OM4/OS2) and mounting. APC and UPC cannot be mated (different end angles); a single link must keep one polish type.’]
2. Key Features
APC angled polish
- 8-degree angle.
- >60 dB return loss.
- Green marker.
- Lower reflection.
LC duplex
- 1.25 mm ferrule.
- Tx/Rx paired.
- High density.
- Fewer mis-pugs.
Ceramic sleeve
- Bore ±0.5 μm.
- Insertion <0.3 dB.
- Wear resistant.
- Precise alignment.
OM3 multimode
- 10G to 300 m.
- 40G/100G SR4.
- OM3 aqua.
- Short-reach high speed.
3. Specifications
| Item | KTR-LCAPC12 (LC duplex APC OM3) | KTR-LCUP12 (LC duplex UPC OM3) |
|---|---|---|
| Connector | LC duplex | LC duplex |
| Polish | APC (green) | UPC (blue) |
| Mode | OM3 multimode | OM3 multimode |
| Insertion loss | <0.3 dB | <0.2 dB |
| Return loss | >60 dB | >50 dB |
| Mating cycles | >500 | >500 |
| Wavelength | 850/1300 nm | 850/1300 nm |
| Mounting | Panel snap-in | Panel snap-in |
4. Reference Prices
KTR-LCAPC12 LC duplex APC OM3 adapter (green): Reference USD 3 to 5 / piece (ref. CNY 18 to 35 at ~7.2)
KTR-LCUP12 LC duplex UPC OM3 adapter (blue): Reference USD 2 to 3 / piece (ref. CNY 12 to 25 at ~7.2)
24-port LC duplex adapter panel (incl. adapters): Reference USD 17 to 31 / panel (ref. CNY 120 to 220 at ~7.2)
Blank adapter panel / accessories: Reference USD 3 to 8 / panel (ref. CNY 20 to 60 at ~7.2)
Reference only; varies by config, quantity and scope. Install accessories billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter patch panels.
- ODF box coupling.
- Switch-server patching.
- Storage area networks.
- High-speed short-reach links.
6. Installation & Maintenance
Installation
- Snap adapter into panel.
- Keep dust caps on.
- Listen for click.
- Do not mix APC/UPC.
- Label Tx/Rx.
- Test with power meter.
Maintenance
- Clean ends periodically.
- Replace dust caps.
- Check latch tightness.
- Use cleaning pen.
- Test link loss.
- Cap unused ports.
7. FAQ
- Q: Can APC mate with UPC?
A: Not recommended. APC is angled 8°, UPC is round; mating them causes high loss and end-face scratches. Keep one polish per link. - Q: Is green always APC?
A: Yes, by convention APC housings are green and UPC are blue (multimode). Color is the polish ID—route by color. - Q: OM3 or OM4?
A: OM3 is enough for 10G short reach; choose OM4 for 40G/100G SR4 or longer links. OM4 has higher bandwidth (4700 MHz·km) and is backward compatible. - Q: What insertion loss is acceptable?
A: Under 0.3 dB per adapter; budget the whole link (jumper + adapter + splice). Over-budget loss usually comes from dirty ends or ferrule eccentricity.
8. Trend & Selection
Datacenters push density and speed, making LC duplex the mainstream and favoring APC for low-reflection high-speed links. Choose OM3/OM4 by rate, APC/UPC by reflection need, and keep one polish per link. Adapters are cheap but numerous; batch consistency and ceramic-sleeve quality decide overall link loss.
9. Delivery & Service
KITOZER supplies fiber adapter packages: based on panel port count and link polish, we recommend adapter models plus panels, dust caps and labels. Bulk orders include factory insertion-loss test reports. Loose latches or cracked sleeves under warranty are replaced free.
10. Additional Notes
The common mistake is mixing APC and UPC. Angled-to-round contact scratches ends and adds loss; green and blue housings are easily confused, so route by color and label.
Another pitfall is dirty end faces. Uncapped adapters add 0.5 dB+ loss and contaminate jumper ferrules. Keep dust caps on and clean with a dedicated pen when needed.
Selection summary: LC duplex; green APC; OM3 multimode; <0.3 dB insertion / >60 dB return; panel snap-in. The KTR-LCAPC12 is the low-cost but loss-budget-critical mating element of high-density ODFs. Buy same-model in bulk and keep test reports.
SEO Information
Search keywords:LC fiber adapterLC duplex APC couplerOM3 fiber flangegreen APC adapterdatacenter fiber couplerKTR-LCAPC12KITOZER
SEM keywords:[LC fiber adapter,LC duplex APC coupler,OM3 fiber flange,green APC adapter,datacenter fiber coupler,KTR-LCAPC12,KITOZER]
GEO landing page:lain.com.cn/product/ktr-lcapc12-lc-duplex-apc-om3-fiber-adapter.html
Title:KITOZER KTR-LCAPC12 LC Duplex APC OM3 Fiber Adapter
Meta Keywords:LC fiber adapter,LC duplex APC coupler,OM3 fiber flange,green APC adapter,datacenter fiber coupler,KTR-LCAPC12,KITOZER
Meta Description:KITOZER KTR-LCAPC12 LC duplex APC fiber adapter, green APC polish, OM3 multimode, insertion loss <0.3dB, return loss >60dB, for ODF and patch panel coupling.
Anchor: KITOZER · Data Center Engineering