KITOZER
KITOZER

KITOZER reinforced rib shelf

KITOZER KTR-SH15 Ventilated Rack Shelf with Reinforcing Ribs

Brand: KITOZER Series: KTR-SH15 Category: Data Center Engineering / Rack Shelf

VentilatedReinforcing ribs80kg static load19-inch standard

1. Overview

[‘The KITOZER KTR-SH15 is a ventilated rack shelf (rack tray / shelf) with reinforcing ribs, used inside 19-inch standard racks to hold switches, routers, patch panels, KVMs and other non-rackmount equipment. The shelf is perforated to let cold air pass through to equipment intakes, supporting hot/cold-aisle airflow and avoiding local heat buildup. Compared with solid shelves, the ventilated version offers about 70% open area for better cooling; compared with sliding shelves, fixed shelves are simpler, cheaper and higher-load for permanently installed gear.’, ‘The KTR-SH15 is formed from 1.5 mm cold-rolled steel with black powder coating. Stamped reinforcing ribs across the front and sides raise bending stiffness while keeping weight low, reaching 80 kg static load. Depths of 330, 450 and 600 mm suit 600 or 800/1000 mm deep racks. Front and rear mounting ears fix to rack square-hole rails with M6 cage nuts, adjustable to any U position. A front retaining lip stops gear sliding forward and a rear cutout eases cable routing. Compared with plastic trays, steel shelves carry more without sagging; compared with sliding rails, fixed shelves need no rail maintenance and suit heavy gear like switches and UPS battery packs.’, ‘Typical deploy: a 42U 600×1000 mm rack holds one KTR-SH15-600 (600 mm deep) at the bottom for a 2U non-rack UPS, and two KTR-SH15-450 in the middle for a switch and fiber terminal box. Shelves fix to square-hole rails with cage nuts; equipment screws or ties down. Ventilation holes align with equipment intakes; the rear cutout passes power and network cables. Select depth 50-100 mm shallower than the rack, load rating by gear weight (80/120 kg), and fixed vs sliding by maintenance need.’]

2. Key Features

Ventilated holes

  • ~70% open area.
  • Air passes through.
  • Less local heat.
  • Supports aisles.

Reinforcing ribs

  • Stamped ribs.
  • High bending stiffness.
  • 80 kg static.
  • Light weight.

Steel & coating

  • 1.5 mm CR steel.
  • Black powder coat.
  • Front retaining lip.
  • Rear cable notch.

Standard mount

  • 19-inch rails.
  • M6 cage nuts.
  • U-adjustable.
  • Multiple depths.

3. Specifications

Item KTR-SH15-330 KTR-SH15-450 KTR-SH15-600
Shelf depth 330 mm 450 mm 600 mm
Rack depth 600 mm 800 mm 1000 mm
Static load 80 kg 80 kg 80 kg
Sheet thickness 1.5 mm 1.5 mm 1.5 mm
Open area ~70% ~70% ~70%
Finish Black powder Black powder Black powder
Mounting M6 cage nut M6 cage nut M6 cage nut

4. Reference Prices

KTR-SH15-330 ventilated shelf (330mm): Reference USD 9 to 15 / piece (ref. CNY 65 to 110 at ~7.2)

KTR-SH15-450 ventilated shelf (450mm): Reference USD 12 to 19 / piece (ref. CNY 85 to 140 at ~7.2)

KTR-SH15-600 ventilated shelf (600mm): Reference USD 15 to 25 / piece (ref. CNY 110 to 180 at ~7.2)

M6 cage-nut screw kit / lip accessories: Reference USD 1 to 4 / set (ref. CNY 10 to 30 at ~7.2)

Reference only; varies by config, quantity and scope. Install accessories billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Holding switches in racks.
  • Non-rack equipment tray.
  • Patch panel / terminal box.
  • KVM / monitor shelf.
  • UPS battery pack support.

6. Installation & Maintenance

Installation

  • Set U position.
  • Press ears to rails.
  • Fix M6 cage nuts.
  • Level then tighten.
  • Place gear on shelf.
  • Screw or tie gear down.

Maintenance

  • Check for sag.
  • Stay under rated load.
  • Keep holes clear.
  • Re-tighten screws.
  • Touch up chips.
  • Re-level after moves.

7. FAQ

  • Q: Ventilated or solid shelf?
    A: Use ventilated for heat-producing gear (switches, servers) so cold air passes; solid suits patch panels and cable managers that produce no heat. Ventilated is the datacenter default.
  • Q: How to pick shelf depth?
    A: 50-100 mm shallower than the rack to leave rear cable space. 600 mm rack → 450 mm shelf; 1000 mm rack → 600 mm shelf.
  • Q: Is 80 kg enough?
    A: Switches and patch panels weigh 5-20 kg, so 80 kg suffices; for heavy UPS battery packs or disk arrays choose 120 kg reinforced or a dedicated battery rack.
  • Q: Do I need sliding?
    A: Choose sliding rails for gear serviced often; fixed shelves for permanently installed gear—cheaper and stronger. The KTR-SH15 is a fixed ventilated shelf.

8. Trend & Selection

Modular cold-aisle and micro-module rooms emphasize airflow, making high-open-area ventilated shelves standard. Pick depth by rack depth, load rating by gear weight, and always use ventilated shelves for heat-producing gear. Shelves are small but their load and ventilation directly affect equipment safety and cooling; standardize across a project for interchangeability.

9. Delivery & Service

KITOZER supplies rack shelf packages: based on rack depth and equipment weight, we recommend shelf models and quantities plus M6 cage nuts, screws and retaining lips. Bulk projects include coating and load-test reports. Sagging or cracked welds under warranty are replaced free.

10. Additional Notes

The common mistake is matching shelf depth to rack depth. A shelf flush with the rear door blocks rear cabling and door closure; make it 50-100 mm shallower.

Another pitfall is overloading. The 80 kg rating is uniform static load; concentrated heavy loads (battery packs) cause local sag—spread them or use a dedicated battery rack.

Selection summary: ~70% ventilated open area; ribbed stiffness; 80 kg static; 1.5 mm steel powder coat; M6 rail mounting. The KTR-SH15 is the basic support for non-rack gear—always ventilated for heat-producing devices, one depth shallower than the rack, with load margin.

SEO Information

Search keywords:rack shelfventilated shelfrack trayribbed shelf19-inch rack shelfKTR-SH15KITOZER

SEM keywords:[rack shelf,ventilated shelf,rack tray,ribbed shelf,19-inch rack shelf,KTR-SH15,KITOZER]

GEO landing page:lain.com.cn/product/ktr-sh15-ventilated-rack-shelf-reinforcing-ribs.html

Title:KITOZER KTR-SH15 Ventilated Rack Shelf with Reinforcing Ribs

Meta Keywords:rack shelf,ventilated shelf,rack tray,ribbed shelf,19-inch rack shelf,KTR-SH15,KITOZER

Meta Description:KITOZER KTR-SH15 ventilated rack shelf with reinforcing ribs, 80kg static load, 19-inch standard, for mounting switches and servers in racks.

Anchor: KITOZER · Data Center Engineering

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart