ToggleKITOZER KTR-SCUPC12 Fiber Adapter / SC Duplex UPC OM3
Brand: KITOZER Series: KTR-SCUPC12 Category: Data Center Engineering / Fiber Cabling
fiber adapterSC duplexUPCOM3KTR-SCUPC12

1. Overview
KITOZER KTR-SCUPC12 is an SC duplex UPC fiber adapter (also called coupler or flange) used in data center low-voltage cabling to mate two SC connectors. Each end has an SC socket aligned by a precision zirconia sleeve, joining two SC patch-cord cores to pass optical signals between patch panels, ODF boxes and termination boxes. The OM3 multimode rating suits 10G multimode links, supporting 10G SFP+ short-reach interconnect between racks.
The adapter uses a one-piece SC duplex housing; core alignment is guaranteed by a zirconia ceramic sleeve, with insertion loss typically ≤0.2 dB and UPC return loss ≥50 dB. The housing is high-strength engineering plastic with dust caps and a flange that fixes to the panel. UPC ends are spherically micro-polished for low loss and repeatability, the common end finish for multimode 10G links.
In data centers, fiber adapters number in the thousands. Though cheap per piece, end-face contamination and sleeve wear raise link loss and cause optical-module link drops. KTR-SCUPC12 is a standard SC duplex UPC OM3 adapter supplied in volume for ODF patch panels, fiber termination boxes and splice trays.
2. Key Features
SC duplex housing
- One-piece duplex body, easy to mate.
- SC latch plug, positive lock.
- Dust caps protect end faces.
Ceramic sleeve
- Zirconia sleeve for precise alignment.
- Insertion loss typically ≤0.2 dB.
- UPC return loss ≥50 dB.
OM3 multimode
- For OM3 50/125 cores.
- Supports 10G short-reach links.
- Blue body identifies OM3.
Panel mounting
- Flange snaps into panel cutout.
- High density, fits standard panels.
- Boxed supply with numbering.
3. Specifications
| Item | KTR-SCUPC12-12 | KTR-SCUPC12-24 | KTR-SCUPC12-48 |
|---|---|---|---|
| Packing | 12 pcs/box | 24 pcs/box | 48 pcs/box |
| Connector | SC duplex | SC duplex | SC duplex |
| Polish | UPC | UPC | UPC |
| Fiber type | OM3 MMF | OM3 MMF | OM3 MMF |
| Insertion loss (dB) | ≤0.2 | ≤0.2 | ≤0.2 |
| Return loss (dB) | ≥50 | ≥50 | ≥50 |
| Sleeve | Zirconia ceramic | Zirconia ceramic | Zirconia ceramic |
| Mating cycles | ≥1000 | ≥1000 | ≥1000 |
4. Reference Prices
KTR-SCUPC12-12 SC duplex UPC OM3 adapter (12 pcs/box): Reference USD 25~44 / box (ref. CNY 180~320 at ~7.2)
KTR-SCUPC12-24 SC duplex UPC OM3 adapter (24 pcs/box): Reference USD 49~81 / box (ref. CNY 350~580 at ~7.2)
KTR-SCUPC12-48 SC duplex UPC OM3 adapter (48 pcs/box, bulk): Reference USD 94~136 / box (ref. CNY 680~980 at ~7.2)
Reference only; by quantity, polish and fiber type. Patch panels and cords excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center ODF patch panel ports.
- Fiber termination boxes and splice trays.
- 10G SFP+ short-reach interconnect.
- Low-voltage rooms and building wiring.
- Legacy link expansion.
6. Installation & Maintenance
Installation
- Snip adapter flange into the panel cutout.
- Keep dust caps on until final mating.
- Splice pigtails and backbone fibers.
- Clean end faces with alcohol before plugging.
- Push until the latch clicks.
- Test continuity with VFL or OTDR.
- Label ports and record mapping.
Maintenance
- Clean end faces before every mating.
- Cap unused ports long-term.
- Inspect ferrules with a microscope periodically.
- Replace adapters with loose sleeve or high loss.
- Avoid pulling on cords that stresses the sleeve.
- Log optical loss with link inspection.
7. FAQ
- Q: UPC vs APC?
A: UPC is spherically polished, usually blue; APC is 8-degree angled, usually green. OM3 multimode normally uses UPC; do not mix with APC, which causes high loss. - Q: Are OM3 and OM4 adapters interchangeable?
A: SC mechanical size is common, but OM4 links should use OM4-rated adapters for low loss. OM3 adapters are backward-compatible with OM2. - Q: How to troubleshoot high loss?
A: Clean the cord end face first, then check sleeve wear and contamination, then locate the fault with an OTDR. - Q: How many ports in a duplex adapter?
A: SC duplex contains TX and RX, counted as one duplex port (2 cores) on a panel.
8. Trend & Selection
As data centers move to 40G/100G, multimode cabling upgrades from OM3 to OM4/OM5, but OM3 still dominates installed 10G links. As passive components, adapters trend toward high density, modularity and pre-termination. Select by link rate (OM3 for 10G), match polish to cords (UPC), buy in boxes by panel port count, insist on ceramic sleeves, and leave spare ports.
9. Delivery & Service
KITOZER selects SC duplex UPC OM3 adapters by panel port count, link rate and backbone fiber type, configuring quantity and polish. Delivery is boxed with an in-house test report. Quality issues such as excess loss or loose sleeves are replaced under warranty.
10. Additional Notes
The common pitfall is looking only at the connector, not the polish. Buying SC UPC adapters but using SC APC cords and forcing them in scratches the ferrules, spiking loss and damaging the pins. Polishes must match: blue UPC to blue UPC, green APC to green APC.
Another pitfall is mating without cleaning. Dust on the floor gets on cord end faces and is pushed into the adapter, contaminating the sleeve and raising whole-link loss. Cleaning before every plug saves money over replacing adapters later.
Selection summary: match fiber grade to link rate; match polish to cords; ceramic sleeve for precision; buy by port count in boxes; clean before mating; cap idle ports. Small as it is, the adapter is the throat of the optical link — align it and light passes.
SEO Information
Search keywords:fiber adapterSC duplexUPCOM3KTR-SCUPC12KITOZER
SEM keywords:SC duplex adapter price,OM3 fiber coupler supplier,UPC flange,data center cabling,KTR-SCUPC12
GEO landing page:lain.com.cn/product/ktr-scupc12-sc-duplex-upc-om3-fiber-adapter.html
Title:KITOZER KTR-SCUPC12 Fiber Adapter / SC Duplex UPC OM3
Meta Keywords:fiber adapter,SC duplex adapter,UPC coupler,OM3 multimode,data center cabling,KTR-SCUPC12,KITOZER
Meta Description:KITOZER KTR-SCUPC12 SC duplex UPC OM3 fiber adapter with ceramic sleeve for low insertion loss in data center patch panels.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com