ToggleKITOZER KTR-WC12 Water Leak Controller / Locating 8-zone
Brand: KITOZER Series: KTR-WC12 Category: Environmental Monitoring / Leak Detection
leak detectionlocating8-zonecontrollerroom environmentKTR-WC12

1. Overview
KITOZER KTR-WC12 is an 8-zone locating water leak controller used in data center DCIM to detect leaks from water pipes, CRAH units and under-floor puddles. Chilled water pipes, condensate lines and CRAH drain pans can leak; water under the floor or at rack bases, if undetected, soaks equipment and causes short circuits. KTR-WC12 runs sensing cable across monitored areas (around CRAH, under pipes, under the raised floor); on a leak, the controller detects a resistance change, alarms, locates the leak distance from the controller (meters), and uploads to DCIM with sound/light linkage.
Locating (vs non-locating) is the series feature: non-locating knows which zone alarms but not where; locating measures resistance along the cable to compute the exact distance to the leak, so staff go straight to the spot instead of searching. 8-zone means 8 sensing cables covering multiple CRAH units and pipe runs. The controller has an LCD, relay outputs (to trigger fans/valves) and RS485/network upload to DCIM.
In room environmental monitoring, leak detection is essential: water-pipe and CRAH leaks are the most common flooding incidents. KTR-WC12, paired with sensing cable and locator probes, is standard DCIM equipment.
2. Key Features
Locating leak
- Cable measures resistance to locate distance.
- Meter-level precision, go straight to it.
- Vs alarm-only non-locating.
8-zone detection
- Up to 8 sensing zones.
- Covers multiple CRAH and pipe runs.
- Separate-zone alarms, no confusion.
Alarm linkage
- LCD shows leak location.
- Relay outputs to trigger fans/valves.
- RS485/network to DCIM.
Sensing cable
- Pairs with locating sensing cable.
- Routed along CRAH and pipes.
- Probes for key points.
3. Specifications
| 项目 | KTR-WC12 | KTR-WC4(4路) | KTR-WC8(8路不定位) |
|---|---|---|---|
| 探测路数 | 8路 | 4路 | 8路 |
| 定位功能 | 定位式(距离) | 定位式(距离) | 不定位(只报警) |
| 定位精度 | 约±1m | 约±1m | — |
| 显示 | LCD | LCD | LED |
| 上传 | RS485/网口 | RS485 | RS485 |
| 继电器输出 | 2路 | 2路 | 1路 |
| 供电 | DC24V | DC24V | DC24V |
| 感应绳 | 配套定位绳 | 配套定位绳 | 不定位绳 |
4. Reference Prices
KTR-WC12 定位式8路漏水控制器(LCD、RS485/网口、继电器): Reference USD 167~361 / unit (ref. CNY 1,200~2,600 at ~7.2)
KTR-WC4 定位式4路漏水控制器(小机房配套): Reference USD 111~222 / unit (ref. CNY 800~1,600 at ~7.2)
定位感应绳(米,按敷设长度计): Reference USD 2~5 / unit (ref. CNY 15~35 at ~7.2)
Reference only; by zones, locating vs non-locating and cable length; cable installation and DCIM host excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Around data center CRAH units.
- Under-floor chilled/condensate pipes.
- UPS and battery room water detection.
- Power-room and room flooding alarms.
- Basement and low-lying areas.
6. Installation & Maintenance
Installation
- Mount controller on wall or in a rack.
- Route sensing cable around CRAH and under pipes.
- Connect cable to the matching zone.
- Use locator probes at key points (drip pans).
- Power up; simulate a leak on the cable to test.
- Set thresholds; connect to DCIM.
Maintenance
- Periodically simulate a leak to test controller and cable.
- Inspect cable for damage or crushing.
- Wipe dirty cable; do not step on it.
- Test relay linkage.
- Verify DCIM alarm linkage.
7. FAQ
- Q: Locating or non-locating?
A: Locating tells you the exact meters to the leak so staff go straight there, suited to large rooms; non-locating only says which zone, for small areas. Rooms prefer locating. - Q: How to route sensing cable?
A: Along likely leak paths: around CRAH drip pans, under pipes, under-floor lines. Fix with clips; do not step on it. - Q: Do leak alarms false-trigger?
A: The cable alarms on water only, not in dry conditions; but dust and condensation can cause false alarms, so keep it clean and away from condensation. - Q: Can it close a valve?
A: Yes: relay outputs connect to an electric water valve or fan, triggering close/vent on a leak, with external actuators.
8. Trend & Selection
Leak detection moves from non-locating to locating, emphasizing pinpoint location and valve linkage; controllers add network/RS485 upload to DCIM, linked to CRAH and water valves. Choose locating for large rooms; size zones by CRAH/pipe count; cable by path length; add electric valves for linkage; test periodically.
9. Delivery & Service
KITOZER supplies locating controllers and sensing cable as a set, configured by room CRAH and pipe layout (zones and cable length). We advise wiring and routing. Delivery includes controller, sensing cable, locator probes and mounting parts. Warranty includes commissioning support.
10. Additional Notes
The common pitfall is installing cable without testing. After install nobody simulates a leak, and on a real leak the cable turns out crushed or a connector loose, so the alarm never reaches the platform. You must simulate and test.
Another pitfall: routing cable where water wont reach. The cable runs behind the CRAH on dry floor while the leaky drip-pan edge is uncovered, so a real leak goes unreported. Route the cable along the flow path, covering the drip pan and directly under pipes.
Selection summary: locating for large rooms; zones by CRAH/pipe count; route cable along the leak path; simulate-test after install; add electric valves for linkage. The leak controller is the rooms water sentry: pinpointed and fast alarms keep equipment dry.
SEO Information
Search keywords:leak detectionlocating8-zonecontrollerroom environmentKTR-WC12KTR-WC12KITOZER
SEM keywords:water leak controller price,locating leak detection supplier,data center leak controller,KTR-WC12
GEO landing page:lain.com.cn/product/ktr-wc12-8zone-locating-water-leak-controller.html
Title:KITOZER KTR-WC12 Water Leak Controller / Locating 8-zone
Meta Keywords:[‘water leak controller,locating leak detection,8-zone leak detector,data center leak detection,leak controller,KTR-WC12,KITOZER’]
Meta Description:KITOZER KTR-WC12 8-zone locating water leak controller pairs with sensing cable to locate leak positions, for data center and CRAH water-leak monitoring and alarms.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com