Table of Contents
ToggleKITOZER KTR-SH18 Rack Shelf / Vented Mesh with Dust Filter
Brand: KITOZER Series: KTR-SH18 Category: Data Center Engineering / Rack Shelf
rack shelfvented meshdust filterfixed traycold aisleKTR-SH18

1. Overview
KITOZER KTR-SH18 is a vented mesh rack shelf with dust filter: a fixed tray installed in a 19-inch cabinet to support equipment that lacks rack ears and cannot mount directly. Switches and servers usually have rack ears bolted to the cabinet square-hole strips, but splice trays, patch modules, small UPS units, monitoring hosts, cable managers and test instruments need a shelf to sit on. KTR-SH18 fixes angle brackets and tray between the left/right square-hole strips; equipment rests on the tray, rated by design load.
Vented mesh is the series feature: the tray is punched full of mesh holes so air passes up and down, avoiding a solid plate that blocks hot/cold airflow and impairs intake cooling. In cold-aisle containment, cold air enters the front and passes through equipment; a vented shelf keeps that path open. A dust filter means a removable dust mat can be added under/over the mesh to filter dust entering from below and protect the gear on the shelf. Depths suit 600/800 mm cabinets; width is standard 19-inch; load is chosen by equipment weight.
In cold-aisle cabinets, the shelf looks trivial but decides whether gear sits securely and whether airflow stays open. A solid shelf blocks air, starving upper equipment; an under-rated shelf sags. KTR-SH18 is supplied in volume as the vented, dust-filter shelf for cold-aisle racks.
2. Key Features
Vented mesh
- Punched mesh lets air pass.
- Does not block cabinet airflow.
- Suits sealed cold-aisle cabinets.
Dust filtration
- Removable dust mat over mesh.
- Filters dust from below.
- Mat washable/replaceable.
Fixed load
- Angle brackets to square-hole strips.
- Supports ear-less gear.
- Load by model (50/80 kg).
Fit
- Depths 600/800 mm.
- 19-inch width.
- Black coated, cabinet-matched.
3. Specifications
| 项目 | KTR-SH18-60 | KTR-SH18-80 | KTR-SH18-80H(重载) |
|---|---|---|---|
| 适配柜深(mm) | 600 | 800 | 800 |
| 承重(kg) | 50 | 50 | 80 |
| 通风形式 | 网孔 | 网孔 | 加密网孔 |
| 防尘网 | 可加装 | 可加装 | 可加装 |
| 安装 | 方孔条固定 | 方孔条固定 | 方孔条固定 |
| 材质 | 冷轧钢喷涂 | 冷轧钢喷涂 | 加厚冷轧钢 |
| 表面 | 黑色静电喷涂 | 黑色静电喷涂 | 黑色静电喷涂 |
| 深度可选 | 600/800 | 600/800 | 800 |
4. Reference Prices
KTR-SH18-60 通风网孔层板(600柜深、承重50kg、含防尘棉): Reference USD 12~25 / unit (ref. CNY 90~180 at ~7.2)
KTR-SH18-80 通风网孔层板(800柜深、承重50kg): Reference USD 15~31 / unit (ref. CNY 110~220 at ~7.2)
KTR-SH18-80H 重载通风层板(承重80kg、加密网孔): Reference USD 22~44 / unit (ref. CNY 160~320 at ~7.2)
Reference only; by cabinet depth, load and quantity; volume pricing for cold-aisle projects. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Ear-less gear (small UPS, monitoring host).
- Splice trays and patch modules.
- Cable managers, instruments, side-mounted switches.
- Tiered layout in cold-aisle cabinets.
- Vented, dust-protected equipment trays.
6. Installation & Maintenance
Installation
- Choose shelf depth by cabinet depth.
- Fix left/right angle brackets to square-hole strips with M6 cage nuts.
- Rest tray on brackets; screw at the rear.
- Center equipment; do not overhang.
- Slide dust mat into the mesh slot.
- Space tiers by equipment height for cooling.
Maintenance
- Remove and wash/replace dust mat.
- Check bracket tightness.
- Watch tray sag under load.
- Clean mesh to keep airflow.
- Re-fix after moving gear.
7. FAQ
- Q: How to choose load?
A: Pick by total tray load with 1.5x headroom. Ordinary modules use 50 kg; batteries or heavy gear use the 80 kg model. - Q: Mesh or solid?
A: Choose mesh for equipment that needs cooling; solid is fine for non-heating instruments and patching. Prefer mesh inside cabinets. - Q: How often for the dust mat?
A: By room cleanliness, usually wash every 3~6 months, replace when badly clogged; clogging blocks airflow. - Q: Does the shelf block air?
A: Mesh has large open area and barely blocks cold air; a solid plate blocks vertical airflow — avoid in cold-aisle cabinets.
8. Trend & Selection
Cold-aisle containment stresses air separation and equipment ventilation, so shelves move from solid plates to vented mesh with removable dust filters, while load ratings rise. Choose depth by cabinet depth; pick heavy-duty for heavy gear; prefer mesh for cooling; wash the dust mat by cleanliness; leave cooling gaps between tiers.
9. Delivery & Service
KITOZER supplies vented dust-filter shelves in volume, configured by cabinet depth, load and count. We provide a shelf layout drawing. Delivery includes tray, brackets, M6 cage nuts and dust mat. Warranty covers deformation.
10. Additional Notes
The common pitfall is guessing shelf load. A 60 kg small UPS on a 50 kg shelf sags within six months: tray dips, gear tilts and wiring strains. Size by total weight with headroom.
Another pitfall: solid plates blocking cold air. A solid shelf cuts vertical airflow inside the cabinet, so upper equipment starves for cold air and develops hot spots. Always use vented mesh shelves in cold-aisle racks.
Selection summary: depth by cabinet depth; load by total weight with headroom; mesh for cooling; wash dust mats periodically; space tiers. The shelf is the equipment footing inside the rack — steady footing and open airflow keep gear healthy.
SEO Information
Search keywords:rack shelfvented meshdust filterfixed traycold aisleKTR-SH18KTR-SH18KITOZER
SEM keywords:rack shelf price,vented mesh tray supplier,dust-filter shelf,KTR-SH18
GEO landing page:lain.com.cn/product/ktr-sh18-vented-mesh-dust-filter-rack-shelf.html
Title:KITOZER KTR-SH18 Rack Shelf / Vented Mesh with Dust Filter
Meta Keywords:rack shelf,rack tray,vented shelf,mesh shelf,dust-filter shelf,KTR-SH18,KITOZER
Meta Description:KITOZER KTR-SH18 vented mesh rack shelf with dust filter is a fixed 19-inch tray that supports equipment while keeping airflow open, used inside cold-aisle cabinets.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com