1. Overview
KITOZER KTR-OS42 is a vertical dual-effect oil separator installed between the outlet of an oil-injected screw air compressor and downstream pneumatic gear. Pneumatic actuators, access-control cylinders, gas-extinguishing pilot cylinders and instrument air all demand clean, oil-free compressed air. Compressors carry over oil mist and liquid oil; left unseparated, this fouls solenoid valves, clogs nozzles and weakens the reliability of fire-suppression actuation. KTR-OS42 uses a vertical vessel: centrifugal baffle separation first, then a coalescing filter element, driving residual oil carry-over to a very low level.
Dual-effect means mechanical separation plus coalescing in one unit. Stage one turns the flow and slams it against baffles, hurling larger liquid droplets onto the wall into a bottom sump for auto or manual drain. Stage two passes the gas through multi-layer glass-fiber coalescing media, where micron oil droplets merge into large drops that settle and drain. Together they handle bulk liquid at high flow while capturing fine mist, giving longer life and lower pressure drop than a single-stage filter.
In data center engineering, the oil separator sits in the air-source train with the compressor, air receiver, dryer and precision filters. The vertical footprint is small and wall-mount friendly, with a bottom drain for centralized waste-oil recovery. Sized by flow rate, KTR-OS42 matches compressors from under a liter to tens of liters per second, and is the key upstream device that keeps pneumatic and fire-suppression air clean.
2. Key Features
Vertical dual-effect vessel
- Small vertical footprint, floor mount by the wall.
- Centrifugal baffle removes bulk liquid droplets.
- Coalescing element captures oil mist.
- Bottom sump with centralized drain.
High separation efficiency
- Very low residual oil carry-over.
- Multi-layer glass-fiber coalescing media.
- Low pressure drop, energy saving.
- High dirt-holding capacity, long life.
Reliable draining
- Auto float plus manual drain valve.
- Visible sump level.
- Centralized waste-oil recovery.
- Differential indicator signals element change.
Center-ready fit
- Flanged and threaded ports.
- Pairs with compressor, receiver, dryer.
- Blast-coated carbon-steel vessel.
- Parallel units for higher flow.
3. Specifications
| 项目 | KTR-OS42(标准) | KTR-OS42-A(高效) | KTR-OS42-B(大流量) |
|---|---|---|---|
| 处理气量(m3/min) | 1.5~3.0 | 3.0~6.0 | 6.0~12.0 |
| 工作压力(bar) | 0.8~1.3 | 0.8~1.3 | 0.8~1.3 |
| 出气含油率(mg/m3) | ≤3 | ≤1 | ≤3 |
| 分离级数 | 离心+凝聚 | 离心+精凝聚 | 离心+大流量凝聚 |
| 接口方式 | G1/2″~G1″ | G1″~G1-1/2″ | 法兰DN25~DN50 |
| 排油方式 | 自动浮球+手动 | 自动浮球+手动 | 自动浮球+手动 |
| 筒体材质 | 碳钢喷塑 | 碳钢喷塑 | 碳钢喷塑 |
| 安装方式 | 立式落地 | 立式落地 | 立式落地/并联 |
4. Reference Prices
KTR-OS42 standard oil separator (1.5~3 m3/min, dual-effect, auto drain). Reference USD 722~1,278 / unit (ref. CNY 5,200~9,200 at ~7.2)
KTR-OS42-A high-efficiency (oil <=1 mg/m3, fine coalescing). Reference USD 1,333~2,278 / unit (ref. CNY 9,600~16,400 at ~7.2)
KTR-OS42-B high-flow (6~12 m3/min, flanged, parallel-ready). Reference USD 2,389~3,889 / unit (ref. CNY 17,200~28,000 at ~7.2)
Reference only; by flow rate, oil class and port style; piping, installation and waste-oil recovery excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- [‘Oil removal at compressor outlet.’, ‘Clean pilot air for gas suppression systems.’, ‘Access control and instrument air.’, ‘Pre/post receiver precision filtration.’, ‘Oil-sensitive labs and cleanrooms.’]
6. Installation & Maintenance
Installation
- [‘Size by compressor flow with 10%~20% margin.’, ‘Floor-mount vertically between compressor and dryer.’, ‘Respect inlet/outlet arrows; drain port faces down.’, ‘Route drain to a waste-oil recovery line.’, ‘Add isolation valves for online element change.’, ‘Pressurize slowly on first start; check no leaks.’]
Maintenance
- [‘Watch the differential gauge; change element at set drop.’, ‘Cycle the auto drain; clear blockages.’, ‘Recover waste oil as hazardous waste.’, ‘Replace elements on time; never overrun.’, ‘Protect drains from freezing in winter.’]
7. FAQ
- Q: Oil separator or precision filter?
A: An oil separator handles liquid bulk and mist in two stages with a drain, high flow and low restriction; a precision filter is a terminal particle stage, higher precision but smaller capacity. They are used in series: separate first, then fine filter. - Q: How often to change the element?
A: By differential pressure, not a fixed schedule. When the gauge reaches about 0.07 MPa, change it; shorten checks where inlet oil is heavy. - Q: Is constant leakage from the auto drain normal?
A: The float drain opens only when oil is present; steady leak or blow-by means a stuck float or seal – service it. - Q: What oil carry-over is acceptable?
A: Instrument air is fine at 3 mg/m3; choose the 1 mg/m3 high-efficiency model for food, pharma or suppression pilot air.
8. Trend & Selection
[‘Air-source treatment is moving toward oil-free compressors, but the large installed base of oil-injected systems still relies on downstream separators to keep air clean. Size by flow rate with margin, choose oil class by the application, parallel units for high flow; high-efficiency coalescing elements are the trend – low drop, long life, less service.’]
9. Delivery & Service
[‘KITOZER supplies vertical oil separators in volume, configured by compressor displacement and by the air-use points. Delivery includes vessel, elements, auto drain, mounting base and manual. Under warranty we guide element replacement by differential pressure and advise on upstream/downstream filtration.’]
10. Additional Notes
The common pitfall is undersizing. A 1.5 m3/min compressor on a 1.0 m3/min separator runs the gas too fast; droplets cannot settle and are carried over, killing efficiency. Always leave margin – bigger is safer.
Another trap is an ignored drain. When the sump fills, oil is swept back into the line, undoing the separation. Cycle the float drain periodically and route waste oil away from the floor.
Selection summary: size by flow with margin; pick the <=1 mg/m3 efficient model for critical air; leave drain space; separate then fine-filter in series; watch differential pressure; cycle the drain. The separator is the oil gate of the air supply - hold the gate and downstream pneumatic and suppression air stays clean.
SEO Information
Search keywords:oil separatorvertical dual-effectcoalescingcompressed air oil removalair sourceKTR-OS42KTR-OS42KITOZER
SEM keywords:oil separator price,compressed air oil removal supplier,precision coalescing separator,KTR-OS42
GEO landing page:lain.com.cn/product/ktr-os42-vertical-dual-effect-oil-separator-coalescing-filter.html
Title:KITOZER KTR-OS42 Precision Oil Separator / Vertical Dual-Effect Coalescing Filter
Meta Keywords:[‘oil separator,vertical dual-effect,coalescing filter,compressed air oil removal,data center air source,KTR-OS42,KITOZER’]
Meta Description:KITOZER KTR-OS42 vertical dual-effect oil separator removes oil mist from compressed air by centrifugal plus coalescing stages with auto drain, for compressor and suppression air cleaning.
Anchor: KITOZER official · Data center & low-voltage equipment
Contact Us
KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com